AGE I AF JAIPUR
AGE I AF JAIPUR OPP- JAL MAHAL AMER ROAD
REPAIR/REPLACEMENT OF SUMMER AND WINTER APPLIANCES AT AF STATION JAIPUR
2023_MES_600178_1
8432/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
AGE I AF JAIPUR
Class E and above and category c (I)
8 documents required · 8 mandatory
₹500
AGE I AF JAIPUR
₹14,000
15 Jul 2023
1 Jun 2023
29 Jun 2023
1 Jun 2023
27 Jun 2023
15 Jun 2023
1 Jun 2023 - 10 Jun 2023
Amount
Comprehensive Maintenance of 7 Ton Precision Airconditioner (PAC) Unit installed at NFS building (Domestic Area) adn EE hall (Tech Area) Airforce station Jaipur including complete servicing by pressure machine, cleaning, Gas Charging,PCB Repairing, replacement of capacitor, replacement of unservicable part like compressor, controller, switchgear component, filter driver, all valves complete all as spd and directed. Note: (i) Rate of Gas, PCB Repairing and capacitor deemed to be included in quoted rate. (ii) item includes Two full service. (iii) Contractor have to attend any breakdown call within 6 Hrs otherwise a penalty of Rs. 500 per hours would be imposed. (iv) Rate of major spare part will be measured and paid separately
Supply only Air fillters for 7.5 TR PAC. Make: Stulz
Supply only Condenser Pressure switch for 7.5 TR PAC. Make: Stulz
Supply only Condenser Fan for 7.5 TR PAC. Make: Stulz
Comprehensive Maintenance of Inverter Split type Airconditioner installed at NFS building Airforce station Jaipur including complete servicing, cleaning, Gas Charging and replacement of PCB, capacitor,compressor, condenser or any unservicable parts complete all as spd and directed. Note: (i) Rate of Gas, PCB Repairing and capacitor deemed to be included in quoted rate.(ii) item includes Two full service. (iii) Contractor have to attend any breakdown call within 6 Hrs otherwise a penalty of Rs. 100 per hours would be imposed.
Taking down Desert Cooler from domestic and technical area of any make of capacity 3000/4500 CFM and refixing in position after servicing, cleaning, greasing, replacing old/defective parts etc complete all as specified and directed. Note : Replaced Items will be measured and paid separately.
Supply and fix only grass pad/khas pad (set of 03 pads) in desert cooler of any make and size installed at site complete all as specified and directed.
Supply and fixing of water pump of 1/7 HP submersible type of desert cooler single phase 230 volt complete all as specified and directed.
Supply and fix water distribution pipe with tee and elbows complete all as specified and directed(Each desert cooler set).
Rewinding of unserviceable/burned fan motor of desert cooler with replacement of new copper winding with proper insulation material coating over winding and cleaning of rusted iron portion and greasing moving part complete all as specified and directed.
M&L for desert cooler body of size 26X26X36 inch made of 24 Gauge MS sheet , mounting arm for fixing fan motor and provisioning of switch cabinate including painting of cooler body complete all as specified and directed.
Material and labour for servicing/cleaning of complete indoor and out door unit of Split Type Air conditioner of 1.0/1.5 TR capacity by means of adding cleaning solution with water. The cleaning of the condensor and chiller tubes shall be done with use of nylon brushes till the scaling is removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition complete all as specified and directed by Engineer-in-Charge. Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch 'A'.
M&L for gas charging freon gas (R-22) for 1.5/2 Ton capacity split type AC complete all as specified and directed.
M&L for gas Top up on AC 1.5/2 Ton capacity any type complete all as specified and directed.
M&L for repair of PCB/IC/Relay/ Transformer of 1.5/2.0 TR capacity split type AC single phase complete all as specified and directed.
All as per Item Srl No. 15.00 above but for 165/180/310 Ltrs capacity Refrigerator complete all as specified and directed.
All as per Item Srl No.15.00 above but for 40/80 Ltrs capacity Water cooler complete all as specified and directed.
All as per Item Srl No. 15.00 above but for 410 Ltr Capacity deep freezer complete all as specified and directed.
M&L gas charging freon gas R-22 after flushing of system complete and testing the system with N2 gas for Refrigerator 165/180/310/410 Ltrs capacity all as specified and directed.
All as per Item Srl No. 19.00 above but Water cooler any type and capacity complete all as specified and directed.
S & F in repair condensor coil for refrigerator of 165/180/310 Ltrs capacity complete all as specified and directed.
S&F in replacement sealed unit compressor ISI Marked suitable for Water cooler 40/80 Ltrs capacity complete all as specified and directed. Make:- Usha/Voltas/LG
All as per Item Srl No. 22.00 above for compressor for refrigerator of 165/180 Ltrs capacity complete all as specified and directed.
All as per Item Srl No. 22.00 above but compressor for refrigerator of 310 Ltrs capacity complete all as specified and directed.
All as per Item Srl No. 22.00 above but compressor for deep freezer of 410 Ltrs capacity complete all as specified and directed.
All as per Item Srl No. 22.00 above but hermitically sealed compressor for window/split type AC of 1.5 ton capacity complete all as specified and directed.
All as per Item Srl No. 22.00 above but hermitically sealed compressor for window /spit type AC of 2 ton Capacity complete all as specified and directed. .
S & F in repair thermostate of refrigerator 165/180/310/410 ltrs capacity complete all as specified and directed.
All as per Item Srl No. 28.00 above but water cooler complete all as specified and directed.
Supply and fix in repair starting capacitor 100/120 MFD complete all as specified and directed.
M&L in repair for fan blade complete set for having split AC 1.5 Ton capacity complete all as specified and directed.
Supply and fix in replacement blower motor complete for window/split type AC 1.5/2 ton capacity complete all as specified and directed.
All as per Srl Item No. 32.00 above but refrigerator 165/180 Ltrs complete all as specified and directed.
Supply and fix thermostate complete for split/Window type AC 1.5 ton capacity complete all as specified and directed.
M&L in repair for replacement of over load relay protector/assembly for refrigerator (any make) 165/180 ltrs capacity complete all as specified and directed.
All as per item Srl No. 35.00 above but 310 ltrs capacity complete all as specified and directed.
All as per item Srl No. 35.00 above but for AC 1.5 ton window/split type complete all as specified and directed.
All as per item Srl No. 35.00 above but for water cooler capacity 40/80 Ltrs complete all as specified and directed.
Supply and fix in replacement running capacitor 50 MFD for 1.5/2 ton AC complete all as specified and directed.
S&F in repair insulation for split AC 1.5/2 Ton copper pipe complete all as specified and directed.
S&F in repair submersible type water pump for air ducting cooler (capacity 18000 CFM) , 40 watt, 50Hz single phase complete all as specified and directed.
Servicing of air ducting cooler capacity 18000 CFM by cleaning, greasing, replacing old/defective parts etc and refixing in same position complete all as specified and directed. Note : Minor replaced Items will be included in sch item .
S&F honeycomb pad (set of 03) of Air ducting cooler of capacity 18000 CFM with matching existing size complete all as specified and directed.
Attending complaints as per online complaint issued by the user for repair / troubleshooting the Heating appliances/cooling appliances / Voltage stabilisers i.e. Split type AC , Window type AC, Water cooler, refrigerator, solar water heater etc complete including replacement of unserviceable fasteners etc, identification of defective components including replacing and to make unit functional. Note :- Supply of U/S Parts for replacement will be measured and paid separately under relevant item of Sch 'A'.
Pressure testing / leak arresting, vaccumising with dry nitrogen gas / oil charging, including replacing the unserviceable strainers and capillary tubes for Split/Window AC 1.5/2 Ton, Refrigrators and water cooler of any capacity complete all as specified and directed .
Dismantling & servicing in repair of voltage stabilizer Single Pole 230 Volts & reassembly the same after carrying out the following repairs of capacity 1 to 3 KVA complete all as specified and directed. (a) Replacement of electronic circuit. (b) Rewinding of burnt transformer with existing gauge of copper conductor complete all as specified and directed.
M&L for rewinding of wall mounted fan 230 V Single Phase 300 mm sweep motor complete all as specified and directed.
Dismantling and taking down solar water heater 250 ltrs capacity from angle iron stand, opening inlet and outlet connection, hose pipe from storage tank and collector plate, drain out tank, and cleaning, servicing, testing and reinstallation complete all as specified and directed.
All as per Srl Item No. 48.00 above but 100 ltrs capacity complete all as specified and directed.
Dismantling and taking down water heater of 25/50 ltrs capacity, opening inlet and outlet connection, hose pipe from storage tank, drain out tank and Cleaning, servicing, testing and reinstallation complete all as specified and directed.
S&F in repairs heating element 2 Kw suitable for water heater of capacity 25 Ltrs of any make and model complete all as specified and directed.
S&F in repairs heating element 2 Kw suitable for water heater of capacity 50 Ltrs of any make and model complete all as specified and directed.
S&F in repairs thermostat set suitable for water heater (storage type) of capacity 25/50 Ltrs of any make and model complete all as specified and directed.
S&F in repairs PVC Connection of water heater storage type of capacity 25 Ltrs complete all as specified and directed.
S&F in repair apparatus plate of geyser for 25/50 ltrs capacity complete all as specified and directed.
S&F in repair 3 pin plug top for geyser of 15 Amps capacity complete all as specified and directed.
S&F in repair indication lamp of geyser 25/50 Ltrs complete all as specified and directed.
S&F AC changeover Guard timer 230V AC, 50Hz, Operating temprature 0-100 degree C, LED display, Programme for 1 hr to 12 hr, metalic enclouser suitable for window/split and pacakage type AC complete all as spd and directed. Make- Carrier or as approved by Engineer in Charge.
shree shyam enterpises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .