Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-Finance | L1 | Accepted-Finance Lowest
bidder | |
| 2 | L2₹39.6 L+₹7.7 L (24.1%)Rejected-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L2 | Rejected-Finance Other than
lowest
bidder |
Tender Value
₹49.6 L
EMD Value
₹99,200
Closing Date
31 Dec 2024, 6:00 pmClosed
GE BABINA
GE BABINA CANTT BABINA 284401
REPAIR/REPLACEMENT OF SOLAR WATER HEATER, ELECTRIC GEYSER AND COMPREHENSIVE REPAIR/MAINTENANCE WORK TO DG SETS, EARTHINGS AND OTHER ITEMS AT BABINA CANTT UNDER GE BABINA.
2024_MES_686332_1
8311/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹99,200
Yes
18 Jan 2025
29 Nov 2024
2 Jan 2025
29 Nov 2024
31 Dec 2024
12 Dec 2024
Amount
M&L for servicing, cleaning and testing of DG sets of make Kirloskar/Cumins /Greaves /Mahindra /Sudhir of capacity 300 KVA by company technician /mechanic visiting the installations of DG sets of following capacities at various locations of Babina Cantt . Checking and testing complete DG sets on load (Including engine, alternator, AMF panel, Body & chases complete) for its proper functioning and making a list of repairs/ replacements required to be carried out in different parts of the DG sets. Carrying out general servicing and minor repairs and/or replacements, all as directed, including following jobs and the works as directed :- (i) Checking and cleaning of diesel filters & oil filters and replacing of defective filters (ii) Checking of engine oil level and topping up , if any. (iii) Checking, cleaning and servicing including oiling & greasing of moving parts of engine and making list of repairs / replacements required, if any. (iv) Checking, cleaning, watering & general servicing of battery, battery charging system including tightening of nuts, bolts, lugs . (v) Checking the earthing connections of neutral and body of DG set, tightening of connections and making a list of repairs / replacements required, if any.
Item No 1 (Contd...) (vi) Checking of self starter and intimating Engr in charge if required to be repaired / specially serviced in workshop. (vii) Checking, cleaning and general servicing of AMF panel including replacement / tightening of nuts, bolts, lugs and other such minor parts, oiling & greasing and making list of repairs / replacements required, if any (viii) Checking, cleaning & general servicing of instrument panel and making a list of repairs/replacements required, if any (ix) Checking, cleaning and general servicing of various parts of DG set such as timer, contactors, meters, etc. and making list of repairs / replacements required, if any. (x) Tightening / replacement of nut/water /oil leakage from any point and rectify if can be rectified by minor repairs / replacements. (xii) Checking, cleaning and adjusting fan belt tension and making a list of replacements requirted, if any. (xiii) Checking, cleaning & general servicing of exhaust / silenecer including checking for leakage of smoke & rectify, if can be rectified by minor repairs / replacements. else make a list of repairs / replacements required, if any.
Item No 1 (Contd...) (xiv) Checking, cleaning and tightenening of electrical connections including replacement of minor parts. Checking AMF panels , connections, contactors , relays cable connections etc for proper function (xv) Checking & cleaning of AVM pads, tightening / replacement of nuts, bolts, & washers and making a list of replacements required, if any. (xvi) Checking, cleaning & tightening of exhaust pipe, flange and lagging, tightening / replacement of nuts, bolts, washers and the like and making a list of repairs / replacements required, if any. (xvii) Checking output of alternator and adjusting the same to specified values, in case of brush type(b) cleaning & servicing of the alternator, minor repairs & replacements (xviii) Checking, cleaning & tightening of all hose pipes, tightening / replacement of nuts, bolts, washers . (xix) Checking, cleaning & servicing of air filter elements :- Note - Rates quoted by the tenderer are deemed to include the cost of S&F in replacement of minors parts like nuts, bolts, washers, gaskets, wirings ,lugs, etc., supply and applying oil & greasing and minor repairs to DG set. Other spares like Engine oil, filters etc shall be paid under seprate items. (i) Spares like Fuel filter ,Engine Oil and Coolent shall be measurd & paid separately under relevent items of Sch 'A'.
Item No 1 (Contd...) (ii) All servicing /repairs works will be carried out by respective company rep/technician of different DG set company makes and provide necessary documentary evidence of the same . Contractor has to arrange all visit and other expenses of company technician and cost is deemed to be included in the unit rate and nothing will be paid extra on this account .
All as per item No:01 but DG Set of 160KVA to 200 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:01 but DG Set of 50KVA to 100 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:01 but DG set of 30 KVA to 40 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:01 but DG set of 10 KVA to 15 KVA Make:--Mahindra,Cummins,Kirloskar,Ashokleyland
Taking out existing defective Fuel filter element primary and secondary with ring and washer for DG set of 300KVA Make:- Cummins and material and labour for new Fuel filter in existing position and satisfactory testing complete all as specified and directed by Eng-in-Charge.
All as per item No:09 but DG Set of 160KVA to 200 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:09 but DG Set of 50KVA to 100 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:09 but DG set of 30 KVA to 40 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:09 but DG set of 10 KVA to 15 KVA Make:--Mahindra,Cummins,Kirloskar,Ashokleyland
Taking out existing defective oil filter element with ring and washer of DG set of 300KVA Make:- Cummins and material and labour for new Oil filter in existing position and satisfactory testing complete all as specified and directed by Eng-in-Charge.
All as per item No:14 but DG Set of 160KVA to 200 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:14 but DG Set of 50KVA to 100 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:14 but DG set of 30 KVA to 40 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:14 but DG set of 10 KVA to 15 KVA Make:--Mahindra,Cummins,Kirloskar,Ashokleyland
Taking out existing defective Air cleaner element with ring and washer ofDG set 0f 300KVA Make:- Cumminsand material and labour for new Air cleaner element in existing position and satisfactory testing complete all as specified and directed by Eng-in-Charge.
All as per item No:19 but DG Set of 160KVA to 200 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:19 but DG Set of 50KVA to 100 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:19 but DG set of 30 KVA to 40 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:19 but DG set of 10 KVA to 15 KVA Make:--Mahindra,Cummins,Kirloskar,Ashokleyland
S & F in replacement "V" belt for Radiator fan of any size suitable to DG set 10KVA to 300 KVA capacities,
S & F in replacement rubber hose pipe set with clamps suitable for DG set of 300KVA capacities Make:- Cumminss
All as per item No:25 but DG Set of 160KVA to 200 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:25 but DG Set of 50KVA to 100 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:25 but DG set of 30 KVA to 40 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:25 but DG set of 10 KVA to 15 KVA Make:--Mahindra,Cummins,Kirloskar,Ashokleyland
Taking out of FIP along with its accessories from DG Set 300 KVA Make :-CUMMINS/MAHINDRA/KRILOSKAR including transpotation to authorised service center for Overhauling repair/recalibration and refixing of DG Set including replacement of necessary parts such as nozzel/injection delivery valve holder benjo bolt copper washer roater bearing etc including testing complete all as specified and directed
All as per item 30 but DG set capacity 160 KVA to 200 KVA.
All as per item 30 but DG set capacity 50 KVA to 100 KVA.
All as per item 30 but DG set capacity 10 KVA to 40 KVA.
M&L for servicing, repairing, maintenance of alternator assembly of DG set of 300/200/160KVA Make:- Cummins,Mahindra by decoupling alternator from DG set and strip opening of the alternator replacement of carbon bush holder, with carbon bush, mospeds, capacitor rectifiers,Terminal plate Silicon Rectifier assembly with metallic plate as existing covered with thin layer of selnium and insulted nut bolt control wiring soldering,Flexible rubber coupling,Carbon brushes set of four, Slip rings and refixing the same in original position with satisfactory testing complete all as specified and directed by engineer-in-charge.
All as per item No 34 above but DG set of 62.5/50/100 KVA Make:-CUMMINS/MAHINDRA/KRILOSKAR
All as per item No 34 above but DG set of 10/15/30/35/40/KVA Make:-CUMMINS/MAHINDRA/KRILOSKAR
Taking out burnt armature winding wire and rewinding of armature with super enamelead copper winding wire of existing gauge of 160 KVA to 300 KVA DG Set insulation of armature of class 'B' insulation and varnishing of armature and drying upto desired temperature and Re-assembling of rotor and stator after rewinding and refixing of alternator with engine by assembling flexible coupling with alternator mouting with nut bolts including making cable connection complete including testing and commissioning at desired load of DG Sets complete all as specified and directed by engineer-in-charge
All as per item 37 but DG set capacity 50 KVA to 100 KVA.
All as per item 37 but DG set capacity 10 KVA to 40 KVA.
Taking out burnt field coil and rewinding of field coil with super enameled copper winding of existing gauge of 160 KVA to 300 KVA DG Set insulation of armature of class 'B' insulation and varnishing of field coil and drying upto desired temperature and Re-assembling of rotor and stator after rewinding and refixing of alternator with engine by assembling flexible coupling with alternator mouting with nut bolts including making cable connection complete including testing and commissioning at desired load of DG Sets complete all as specified and directed by engineer-in-charge.
All as per item 40 but DG set capacity 50 KVA to 100 KVA.
All as per item 40 but DG set capacity 10 KVA to 40 KVA.
M & L for taking out radiator and connecting parts of DG set 160KVA to 300 KVA for repair,welding,brazing,leak testing, descaling & refixing to DG set to its original position and testing on load for DG Sets of Make Kirloskar/Cumins/Greaves / Mahindra /Sudhir complete all as directed.
All as per item 43 but DG set capacity 50 KVA to 100 KVA.
All as per item 43 but DG set capacity 10 KVA to 40 KVA.
S & F in replacement solonid Switch for 160 to 300 KVA DG set and testing complete for proper functioning for DG sets of Make Kirloskar/Cumins/Greaves/ Mahindra/ Sudhir complete and testing all as directed..
S & F in replacement solonid Switch for 50 to 100 KVA DG set and testing complete for proper functioning for DG sets of Make Kirloskar/Cumins/Greaves/ Mahindra/ Sudhir complete and testing all as directed..
S & F in replacement solonid Switch for 10 to 40 KVA DG set and testing complete for proper functioning for DG sets of Make Kirloskar/Cumins/Greaves/ Mahindra/ Sudhir complete and testing all as directed..
M & L for servicing, repairing, maintenance of self starter assembly of DG set 0f 160 KVA to 300KVA capacity complete with switch magnet, carbon set, field coil, solenoid switches and refixing the same in original position complete all as specified and directed.
All as per item No:49 but DG Set of 50KVA to 100 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:49 but DG set of 30 KVA to 40 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:49 but DG set of 10 KVA to 15 KVA Make:--Mahindra,Cummins,Kirloskar,Ashokleyland
Descaling of water jacket of engine by using chemical descaling solution with pressure circulation pump,leak testing, soldering, brazing, checking for leaks and recirculating with clear water complete all as directed for DG set of capacity 160 KVA to 300 KVA Make\;-Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed.:-
All as per item No:53 but DG Set of 50KVA to 100 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:53 but DG set of 30 KVA to 40 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:53 but DG set of 10 KVA to 15 KVA Make:--Mahindra,Cummins,Kirloskar,Ashokleyland
S & F in repairs Anti vibration pad suitable for 10KVA to300 KVA DG set Make Dunlop or as approved by GE all as directed .
S&F in replacement of Ignition Switch of DG Sets for DG sets of Make:-Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed.
S&F in replacement of AVR suitable forDG set of capacity 160 KVA to 300 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed.
All as per item No:59 but DG Set of 50KVA to 100 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:59 but DG set of 30 KVA to 40 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:59 but DG set of 10 KVA to 15 KVA Make:--Mahindra,Cummins,Kirloskar,Ashokleyland
S&F PVC insulated copper conductor cable 25 Sqmm single core, of 2 mtr length, solidered with 2 nos gunmetal battery terminals suitable for 60-180 Ah 12v/24 volt DC battery complete all as specified and directed.
Supply and fix in replacement Self starter, 12 Volts, suitable for fixing at100/ 62.5/40/35/30/15 KVA DG Set fixed in repairs complete all as specified.
Supply and fix in replacement Self starter, 24 Volts, suitable for fixing at 300/200/160 KVA DG Set fixed in repairs complete all as specified.
Overhauling of water pump assembly complete including material and labour for impeller, shaft seal bearing, gaskets washers and rubber hose complete for DG set of 300/200/160KVA Make:- Cummins,Mahindra
All as per item No:66 but DG Set of 50KVA to 100 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:66 but DG set of 30 KVA to 40 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:66 but DG set of 10 KVA to 15 KVA Make:--Mahindra,Cummins,Kirloskar,Ashokleyland
S&F in replacement control wiring existing specifications and size of DG Set 160 to 300 KVA for DG sets of Make:-Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed.
All as per item 70 above but for DG Set 50 to 100 KVA of Make:-Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed.
All as per item 70 above but for DG Set 10 to 40 KVA of Make:-Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed.
Disconnection and taking out the unservisable turbo charger assembly for DG set of 300/200/160KVA Make:- Cummins,Mahindraand taking to workshop, strip opening of turbo charger and replacement of repair kit reassembling and fixing back to engine and testing complete all as specified and directed.
All as per item No:73 but DG Set of 50KVA to 100 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:73 but DG set of 30 KVA to 40 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:73 but DG set of 10 KVA to 15 KVA Make:--Mahindra,Cummins,Kirloskar,Ashokleyland
Supply and fixing in replacement battery of capacity 12V 180 AH Make:- Exide/Amaron
Supply and fixing in replacement battery of capacity 12V 150 AH Make:- Exide/Amaron
Supply and fixing in replacement battery of capacity 12V 100 AH Make:- Exide/Amaron
M&L for repairing decarburizing, Engine ,cleaning ,washing manifolds exhaust system for DG set 0f 300/200/160KVA Make:- Cummins,Mahindra and connected items including replacement of necessary nuts bolts washers bolts washer etc with necessary masonry work reqd for above complete all as specified and directed
All as per item No:80 but DG Set of 50KVA to 100 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:80 but DG set of 30 KVA to 40 KVA Make:-Mahindra,Cummins,Kirloskar,Ashokleyland
All as per item No:80 but DG set of 10 KVA to 15 KVA Make:--Mahindra,Cummins,Kirloskar,Ashokleyland
S & F in replacement DG Set power controller for generator set monitoring, metering and control system to control voltage ,speed governing ,start and stop control for capacity up to 300/200/160KVA DG Set for DG sets of Make Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed.
All as per item 84 above but power controller for 50KVA to 100 KVA DG Set .
All as per item 84 above but power controller for 30 KVA to 40 KVA DG Set .
Supply and fix in replacement Relay for AMF panel for capacity 30 KVA to 160 KVA DG sets of Make Mahindra,Cummins,Kirloskar,Ashokleyland complete and testing all as directed.
Supply and fix in replacement Relay for AMF panel for capacity 200 KVA to 300 KVA DG sets of Make Mahindra, Cummins, Kirloskar, Ashokleyland complete and testing all as directed.
Supply , fix , commissioning and testing factory made LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x5mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified:-
Item No 89 Contd... (a) Copper bus bar four strips 400 Amps ,415 volts,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. Incoming:- (b) MCCB, 04 Pole, 200 Amps with ultimate breaking capacity Icu- 35 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%)(Make :- Havells/L&T/Indoasian) Outgoing:- (c)MCCB, 04 Pole, 100 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 No (Ics=Icu=100%)(Make :- Havells/L&T/Indoasian) (d)MCCB, 04 Pole, 63 Amps with ultimate breaking capacity Icu- 16 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 No (Ics=Icu=100%)(Make :- Havells/L&T/Indoasian) (d) change over switch 100 Amp, 4 pole ,415 volt onload type front operated.
Supply & Fix 3 pole power Contractor ML-6,110/125 A,415 V of Make L&T or equvalent in ABB/Siemens/Crompton
Supply & Fix 3 pole power Contractor ML-10/ML12 ,200/250 A,415 V of Make L&T or equvalent in ABB/Siemens/Crompton
S & F in replacement off Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 63 Amp in SS enclosure with side handle MakeHavells /INDO ASIAN/L&T
S & F in replacement off Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 100 Amp in SS enclosure with side handle MakeHavells /INDO ASIAN/L&T
S & F in replacement on Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 315 Amp in SS enclosure with side handle MakeHavells /INDO ASIAN/L&T
S & F in replacement off Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 200 Amp in SS enclosure with side handle MakeHavells /INDO ASIAN/L&T
S & F in replacement off Load Change over switch 4 pole 415 Volt 50 HZ ,side operated 400 Amp in SS enclosure with side handle MakeHavells /INDO ASIAN/L&T
S & F in replacement MCCB's,415 Volts , 4 pole , fixed thermal & fixed magnetic settings, having 630 Amps 50 KA 4 Pole capacities complete all as specified and as directed.
S & F in replacement MCCB's,415 Volts , 4 pole , fixed thermal & fixed magnetic settings, having 400 Amps 36 KA 4 Pole capacities complete all as specified and as directed.
S & F in replacement MCCB's,415 Volts , 4 pole , fixed thermal & fixed magnetic settings, having 315 Amps 36 KA 4 Pole capacities complete all as specified and as directed.
S & F in replacement MCCB's,415 Volts , 4 pole , fixed thermal & fixed magnetic settings, having 160 Amps 25 KA 4 Pole capacities complete all as specified and as directed.
S & F in replacement MCCB's,415 Volts , 4 pole , fixed thermal & fixed magnetic settings, having 125 Amps 25 KA 3 Pole capacities complete all as specified and as directed.
S & F in replacement MCCB's,415 Volts , 4 pole , fixed thermal & fixed magnetic settings, having 63 Amps 16 KA 3 Pole capacities complete all as specified and as directed.
Supply and fill/top up the distilled water of 01 ltr packing in the battery complete all as specified and directed .
Supply only for toping up of pre mix Coolant for DG Set complete all as specified and directed .
Supply and filling in for toping up Engine oil 15 W 40 in 200 ltr steel drum (Barrel) facory sealed non returnable drum complete all as specified and directed .
Taking out of PT Pump along with its accessories form DG set 300/200/100 KVA Make:-Cummins/Mahindra/ Kirloskar including transportation of authorised service center for repair/recalibration and refixing of DG set including testing complete all as specified and directed.
Taking out of PT Pump along with its accessories form DG set 62.5/40/30 KVA Make:-Cummins/Mahindra/ Kirloskar including transportation of authorised service center for repair/recalibration and refixing of DG set including testing complete all as specified and directed.
Dismantling the fly wheel coupling between engine and alternator and Supply and replace complete set of bullet rubber bushes, coupling nuts & bolts including proper alignment of engine & alternator for smooth running for DG set of capacity 300 to 100 KVA complete all as specified and directed by Engineer-in-Charge.
All as per item No. 111 above but DG set of 62.5/50 KVA Make:-Kirloskar,Ashokleyland
All as per item No. 111 above but DG set of 15/30/35/40 KVA Make:-Kirloskar,Mahindra
S&F in repair, PCB assy complete with display and update software including wiring work suitable for DG Set of capacity 50 to 63 KVA
S&F in repair, PCB assy complete with display and update software including wiring work suitable for DG Set of capacity 100 to 300 KVA
M&L for earthing complete with galvanised steel earth plate electrode of size 600X600X6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.50 mtr below the ground level connected to galvanised iron strip of 32x6 mm as earth lead by means of bolts nuts check nuts & washers of galvanised iron or steel ,surrounded by charcoal of coke and salt, protected by GI pipe 40 mm bore (light grade), water pipe 20mm bore GI medium grade with funnel and wire mesh,and making chamber of PCC (1:4:8) type D-2 using 40 mm graded stone aggregate and coping shall be in PCC(1:3:6) type C-1 using 20 mm graded stone aggregate, 50 mm thick cover of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate, reinforced with 8 mm dia TMT bars @ 80 mm c/c boath ways including excavation and earth work and removal of surplus soil to distance n exc 50 m complete all shown in electrical plate No 3 of SSR part- 2010 and also including making test point for testing of earthing made out of gun metal or phosphorous bronge size 75x75x25 mm complete all as specified and directed. Note :-(i) The cost of GI earth lead & G I pipe of 7.50 mtr length for protection of GI wire and excavation work for pit shall deemed to be included in this item. (ii) Earthing test will be carried out and if desired result not achieved and the earthing will be redone to achieve desired result without any extra payment.(iii) Charcoal dust and common salt upto 1.5 meter depth shall be filled in layers of 15 centimeters all around the earth plate.
S&F 1100 Volts grade heavy duty cable PVC insulated stranded Copper conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connections , of size one 3 core cable flat or circular of size 16 sqmm etc complete all as specified and directed.
Supply, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with multi stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 95 sqmm 3.5 core complete all as specified and directed.
Description all as per item No 118 above but of size 70 Sqmm 3.5 core and ditto
Description all as per item No 118 above but of size 50 Sqmm 3.5 core and ditto
Supply in replacement Battery Charger 12 Volt DC,for dg set
Repair & Maintenance of existing canopy of eco friendly DG Set of any capacity, cleaning of internal & external parts, tightening of loose parts, painting of rusted area, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations complete all as specified and directed.
Material and labour in replacement broken MS Hinges suitable for Canopy door for any type/capacity of DG Sets (as per sample) complete all as specified and directed.
M&L for preparing old painted surface of DG sets of capacity 10 KVA to 40 KVA (complete including engine, alternator, body & chases) by thoroughly cleaning the surfaces to remove dirt, dust, rust flakes and paint flakes, using wire brush or sand papers, damp cloth or as directed. Priming the surface with anti corrosive primers using suitable sprayers. Applying automotive paint using sprayers till glossy finish is obtained, complete all as per manufacturers instructions and as directed.
All as per item no 124 but DG set of capacity 50 KVA to 62.5 KVA
M&L for structural MS frame work half round or other stock section including securing posts and stuts in fencing, frame work for gates of substations, base frame for equipments including securing bolts, posts and sturts in fencing including cutting and makeing shapes as desired, drilling holes, notching for wire cut to size and made to the exisitng shape suitable for fixing MS chequred duct covers / door panels, including nuts, bolts and washers, welding / bracing works, bending cold or hot drilling holes for bolts in any shapeetc flat iron fillets (for securing wire mesh etc) all necessary drilling, bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 including one coat of primer and two coats of synthetic enamel paint to the entire steel surfaces all as specified and directed.
S& F pre-painted galvalume roofing sheet with deep depth trapezoidal prpfile of thickness 0.50mm (26 gauge) ,fixed with specially designed one touch fasteners and allied components of colour and and pattern as directed by the GE complete all as specified and directed.
M&L for chain link MS galvanised fencing including lines wires, dia of chain link n less than 3.5 mm any mesh any size any type to any type strands rails, straining bolts etc complete all as specified and directed.
S&F mild steel screw bolt (mechine made) with hexagonal or square, head, n.exc 5 cm but n.ecx 10 cm dia complete all as specified and directed.
M&L TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and includingmild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as directed.
Servicing and repairs in Automatic Main Failure ( AMF) control panel of 180 KVA at old power house by complete checking entire circuit and replacing the defective parts like contactor, logic control relays of AMF function, HRC fuses, start and stop relays, detoriated control wires and completing the panel in all respect. starting and testing and commissioning the AMF panel with DG set in both manual and auto mode function complete all as specified and directed by Engineer-in-charge Note: The replacement parts and items shall be measured and paid seperately
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in foundations/foot path etc complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness below or above ground level including removal of debris complete all as specified and directed
M&L for overhauling of DG sets of make Kirloskar/Cumins /Greaves /Mahindra /Sudhir of capacity 30/40 KVA by company technician /mechanic visiting the installations of DG sets of following capacities at various locations of Babina Cantt . Checking complete DG sets on load (Including engine, radiator, alternator, AMF panel, Body & chases complete) for its proper functioning and making a list of repairs/ replacements required to be carried out in different parts of the DG sets. Carrying out overhauling and replacements, all as directed, including following jobs and the works as directed with the replacement of following supply only items:- (i) Checking including oiling & greasing of moving parts of engine and making list of repairs / replacements required
SUPPLY ONLY BEARING (CRANK SHAFT REAR TOP-STD-BIM)
SUPPLY ONLY BEARING CR'SFT RER BTM-STD-BIM
SUPPLY ONLY WASHER SEAL CU G14.50X17.91X1.85
SUPPLY ONLY O RING 96.60X3.53 NBR
SUPPLY ONLY PIN PISTON - ESCORT
SUPPLY ONLY PACKING RING (DI)
SUPPLY ONLY BELT FAN
SUPPLY ONLY CIRCLIP INT - LUG 160 X 4
SUPPLY ONLY BELT GEN./ALT. COGGED (HILTON)
SUPPLY ONLY WASHER INJECTOR - PS TYPE
SUPPLY ONLY PISTON FOR 88.9 BORE LONG STROKE
SUPPLY ONLY GASKET OIL PAN 4 CYL
SUPPLY ONLY PIPE FEED PUMP TO FILTER
SUPPLY ONLY PIPE FUEL FILTER TO FIP
SUPPLY ONLY WATER_PUMP_ASSY_HD_MDI_SFL
SUPPLY ONLY RING SET FOR SINGLE PISTON DI
SUPPLY ONLY HOSE RADIATOR OUTLET
SUPPLY ONLY POWEROL MDI 4CYL MLS GASKET
SUPPLY ONLY SLEEVE CYLINDER (DIAMETER 88.9 X110)
SUPPLY ONLY PIPE CPTE. OVERFLOW 4DI EXPORT GENSET
M&L for overhauling of DG sets of make Kirloskar/Cumins /Greaves /Mahindra /Sudhir of capacity 62.5 KVA by company technician /mechanic visiting the installations of DG sets of following capacities at various locations of Babina Cantt . Checking complete DG sets on load (Including engine, radiator, alternator, AMF panel, Body & chases complete) for its proper functioning and making a list of repairs/ replacements required to be carried out in different parts of the DG sets. Carrying out overhauling and replacements, all as directed, including following jobs and the works as directed with the replacement of following supply only items:- (i) Checking including oiling & greasing of moving parts of engine and making list of repairs / replacements required
SUPPLY ONLY PISTON ASSEMBLY
SUPPLY ONLY CYLINDER LINER
SUPPLY ONLY INTERMIDATE RING 1.3 MM
SUPPLY ONLY SET OF JOINTS
SUPPLY ONLY FUEL FILTER KIT
SUPPLY ONLYSET OF O RINGS: HA694
SUPPLY ONLY VALVE PAIR
SUPPLY ONLY VALVE STEM SEAL
SUPPLY ONLY VALVE GUIDE
SUPPLY ONLY VALVE SEAT INSERT - INLET
SUPPLY ONLY VALVE SEAT INSERT - EXHAUST
SUPPLY ONLY Main bearing
M & L for dismantling and taking up/down DG sets of any capacity of any size from foundations after disconnecting electric connection and transportation from one location to an other location at babina cantt incl re-assembling, re-fixing in position, including connecting in original position & testing complete as directed and specified .
Supply only aluminium lugs of size 300 to 400 sqmm complete all as specified and directed.
Supply only aluminium lugs of size 200 to 250 sqmm complete all as specified and directed.
Supply only aluminium lugs of size 120 to 150 sqmm complete all as specified and directed.
Supply only aluminium lugs of size 75 to 95 sqmm complete all as specified and directed.
Supply only aluminium lugs of size 35 to 50 sqmm complete all as specified and directed.
Supply only aluminium lugs of size 16 to 25 sqmm complete all as specified and directed.
Supply only aluminium lugs of size 6 to 10 sqmm complete all as specified and directed.
S&F in replacement of contactor AC rating 325 Amp 2 pole, MCX 41 type (2 ‘no’ + 2 ‘nc’) suitable for 200 KVA DG set complete all as specified and directed.
S&F in replacement of contactor AC rating 250 Amp 2 pole, MNX 185 type (2 ‘no’ + 2 ‘nc’) suitable for 100 KVA DG set complete all as specified and directed.
Note - For S No 1 to 174 :- (i) Intimation for any unserviceable DG set of any capacity mentioned here under relevent items will be given to contractor or his accredited representative/superviser via telephone followed by in writing . The unserviceable DG set will have to be repaired , re-installed in and made functional without any defect within a period of 24 hrs after intimation to contractor failing which a panel recovery @ Rs. 200/- per hour for delay period will be initiated and deducted from contractor's payments /RAR/Final bill etc .
Taking down, dismantling / unscrewing electric water heater (Geyser) for repair / servicing and refixing after repair reconnecting of electrical and water supply and testing with water pressure complete as specified and as directed. Note : If required to deposit unserviceable water heater to AGE (E/M) yard and collection serviceable against replacement from AGE (E/M) yard is responsibility of the contractor)
S & F heating element 2 KW , Triangle type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S & F heating element 1.5 KW, Triangle type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elecon Agency Or other ISI Marked
S & F heating element 2 KW, cup type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S & F heating element 1.5 KW, cup type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S & F heating element 2 KW ,Square type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S & F heating element 1.5 KW, square type of any type copper sheathed and nickel plated of suitable size for water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S & F heating element 2 KW watt,Porcelain type for DITZ/VENUS type water heater complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S & F heating element for Solar water heater 2 KW, (size as per site requirement)ISI marked of any type copper sheathed and nickel plated of suitable size complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S & F heating element for Solar water heater 3 KW, (size as per site requirement)ISI marked of any type copper sheathed and nickel plated of suitable size complete all as specified and as directed Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S & F fusible plug having melting point 90 degreeC to 100 degree (as per sample) complete all as specified and as directed.
S & F safety valve dead weight type for 25 Ltr gyeser (As per sample) complete all as specified and as directed.
S & F safety valve dead weight type for 50 Ltr Gyser(As per sample) complete all as specified and as directed.
S & F glass wool for geyser complete all as specified and as directed.
S & F base plate complete with rubber packing suitable for water heater (geyser) for 25 litre capacity any make complete all as specified and as directed.
S & F base plate complete with rubber packing suitable for water heater (geyser) for 50 Ltr any make capacity complete all as specified and as directed
S&F outer cover of geyser suitable for 25 Ltr capacity of geyser, complete all as directed
S&F outer cover of geyser suitable for 50 Ltr capacity of geyser, complete all as directed
S & F thermostate switch suitable for 25 Ltr water heater(Geyser) of size 11"/11"/280 mm any make ranging from 5 degree centigrade to 75 degree centigrade including making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S & F thermostate switch suitable for 25 Ltr water heater(Geyser) of size 7"/7"/175 mm any make ranging from 5 degree centigrade to 75 degree centigrade including making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S & F thermostate switch suitable for 25 Ltr water heater(Geyser) 4 terminals 16 KA 250 Volts AC Capillary thermal Switch thermosate any make ranging from including making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S & F thermostate suitable for 50 Ltr water heater(Geyser) of any make ranging from 5 degree centigrade to 75 degree centigrade including making electric connection complete all as specified and as directed.Make :- Bajaj / Airex/ / Elcon Or other ISI Marked
S&F storage type water heater (Geyser), 230 Volt AC, 25 Ltrs capacity 2000 W with minimum 5-star rating comprising inner tank, suitable heatng element, thermostate with adjustable temperature stting 0-90 C, indication lamps provision ofr inlet outlet and air vent connections & NRV, PVC connection 15 mm size, heavy duty with brass nuts, 450 mm long mounteted on wall surfaces including all fixing arrangement such s faster bolts, nuts washers etc complete including making good disturbed wall surfaces matching with the existing surfaces and finishing all as specified and as directed by Engr-in-charge Make - Havells (Puroplus) or equivalent in Bajaj (Shakti ) / Pearl
S&F storage type water heater (Geyser), 230 Volt AC, 50 Ltrs capacity with minimum 5-star rating comprising inner tank, suitable heatng element, thermostate with adjustable temperature stting 0-90 C, indication lamps provision ofr inlet outlet and air vent connections & NRV, PVC connection 15 mm size, heavy duty with brass nuts, 450 mm long mounteted on wall surfaces including all fixing arrangement such s faster bolts, nuts washers etc complete including making good disturbed wall surfaces matching with the existing surfaces and finishing all as specified and as directed by Engr-in-charge Make - Havells (Puroplus) or equivalent in Bajaj (Shakti )
S & F Geyser Assembly for 25 Ltr capacity geyser Triangle type / Square type ( As per sample ) with rubber packing ( As per Sample ) complete all as specified and as directed. Airex/ / Elcon Or other ISI Marked
S & F Geyser Assembly for 50 Ltr capacity geyser Triangle type / Square type ( As per sample ) with rubber washer complete all as specified and as directed. Airex/ / Elcon Or other ISI Marked
S & F geyser inner tank stainless steel of 25 litre capacity complete all as specified and as directed
S & F geyser inner tank stainless steel of 50 litre capacity complete all as specified and as directed
S & F PVC connection pipe 15mm dia of 450mm long with check nuts on both end with rubber washer complete all as specified and as directed.
S & F PVC insulated flexible cable 3 core with standed copper conductor of size 2.5 Sqmm against unserviceable flexible cable complete all as specified and as directed.
S & F PVC insulated flexible cable 3 core with standed copper conductor of size 4.00 Sqmm against unserviceable flexible cable complete all as specified and as directed.
S & F plug top 3 pin 15 Amps ISI Marked as specified and as directed.
S& F non return valve 15 mm dia bore cast copper alloy screwed for iron pipe or brass ferrule complete all as specified and as directed.
S& F 15mm bore GI tubing, medium grade fixed on walls/floor/ceiling with and including necessary GI fittings such as sockets, bends, elbows, tees, short pieces etc including taking down existing GI tubing including making good disturbed surface complete all as specified and directed.
S& F 20 mm bore GI tubing, medium grade fixed on walls/floor/ceiling with and including necessary GI fittings such as sockets, bends, elbows, tees, short pieces etc including taking down existing GI tubing including making good disturbed surface complete all as specified and directed.
S & F in stop valves chromium plated cast copper alloy, screwed down high pressure with crutch or butter fly handle external threaded screwed bothends for iron pipes of 15 mm dia complete all as specified as directed.
S & F bib taps chromium plated screwed down high pressure with crutch or butterfly handle external threaded screwed for iron pipes 15 mm dia complete all as specified.
S & F neon lamp indicator red / green rectangular / round type, complete all as specified and as directed.
Supply & fixing GI nut bolts any type any size as per site requerment all as directed
M & L insulation for hot water worn out insulation 15mm dia GI pipe, medium grade for solar water heater system complete all as specified and as directed.
M & L for brazing rod of copper / steel inner tanks of 25 ltr capacity of geyser and testing complete all as specified and as directed.
M & L for brazing rod of copper/ steel inner tanks of 50 ltr capacity of geyser and testing complete all as specified and as directed.
S & F sheet metal enclosure with two pin socket , chain plug cover with one MCB SP of 20 Amp capacity with alignment 10 KA ‘C’ series complete all as specified and as directed.
Suppling and fixing Gun metal gate valve 15 mm bore with all GI fitting as per existing all as specified and directed
Suppling and fixing in replacement of Gun metal gate valve 20 mm bore with all GI fitting as per existing all as specified and directed
Supply and fixing in replacement of solar plate collector as per existing complete with rubber packing with solar panel glass ( As per sample ) complete all as directed. Note :- The rates shall be deemed to be included for all materials or manpower required which are otherwise not specifed in the discription but are requred to ensure proper installation commissioning and operation of soler water heater system as directed at site
Supply and fixing 500 ltr capacity of rotational moulded polyethylene water storage tank 2 layered construction ISI marked BLACK cylindrical vertical with closed top, hoisting and fixing in position including 20mm bore GI pipe medium grade wash out pipe 450 mm long with and 20mm dia GI pipe medium grade over flow pipe 600mm long with fitting including dismantling of existing water tanks of any type and capacity exceeding 500 ltr complete all as directed. Make -Sintex / Rotex
Supply and fixing 1000 ltr capacity of rotational moulded polyethylene water storage tank 2 layered construction ISI marked WHITE cylindrical vertical with closed top, hoisting and fixing in position including 20mm bore GI pipe medium grade wash out pipe 450 mm long with and 20mm dia GI pipe medium grade over flow pipe 600mm long with fitting including dismantling of existing water tanks of any type and capacity exceeding 1000 ltr complete all as directed. Make -Sintex / Rotex
S&F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm GI suspension wire one twin core cable flat or circular of size 10 Sq mm to be connected to existing MCB box / Main switches complete all as specified as dircted.
S&F 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape & overall PVC sheathed in service connection suspended by insulating hanger not more than 1 meter apart including 4 mm GI suspension wire one twin core cable flat or circular of size 6 Sq mm to be connected to existing MCB box / Main switches complete all as specified as dircted.
S&F for sub main wiring with PVC insulated, unsheathed 2 single core cable 1100 volts grade with copper conductor of size 6 sq mm (Nominal area) multi stranded drawn into conduit (Existing / new) with and including 6 sqmm green stranded copper conductor as contineous earthwire with lugs complete all as specified and as directed. Note: New conduit and conduit accossories shall be measured separately.
S & F Regid non-metallic PVC conduit not less than 20 mm dia (external) ISI marked (on surface) incl of all accessories and all fittings such as Tees,bends, elbows, reducers, bell mouth, tube ends and fixing accossories such as couplers,lock nuts, saddles, pipe hook etc complete all as specified and as directed
M&L for repair/maint of Shadowless OT light installed at MH babina including disconnecting and taking down from the existing position and fixing it original position after functional in all respest complete including repalcement of the following spares as require complete all as specified and directed. 1. Lenses: High - precision optical lenses designed to focus and distribute light evenly across the surgical field.( 48 Lenses)2. LEDs : Advanced light - emitting diodes(LEDs) ensuring brigh, long-lasting, and energy- efficient illumination.( 48 LEDs)3. Circuit : LED 50 circuitry panel to control and maintain the OT light's opreations,delivering consistent and reliable performance.(01 circuitry panel set)4. Power supply : Durable and efficient power supply unit, designed to support the OT light's stable function during procedures.( 01 power supply) Notes(i) Repair/Repalcement work will be carried out through Authorisied rep of OEM of Shadowless OT light(ii) Spare part used will only be approved make of OEM
SHRI HARI CONSTRUCTION (BID ID -3193292)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .