Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC F 25 SECTOR 6 NOIDA UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹39.3 L | L1 | Accepted-AOC Lowest bid |
| 2 | L2₹42.0 LRejected-Finance | ₹42.0 L | L2 | Rejected-Finance Higher bid |
| 3 | L3₹42.1 LRejected-Finance CINNAMARA JORHAT | JORHAT | JORHAT | ₹42.1 L | L3 | Rejected-Finance Highest Bid |
| Sl No | Description | Qty | Unit | DLS ENVIROTECH CORORATION PVT LTD L1 | Radiant Engineering Company L3 | Swapnil Kukurachowa L2 |
|---|---|---|---|---|---|---|
| 1.00Setting up of compost pit (30 Pits) Enter amount for 10 Pits | ||||||
| 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. | 9.55 | Cum | 194 ₹5,558.10 | 73.96 ₹2,118.95 | 73.96 ₹2,118.95 |
| 1.02 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) | 3.62 | Cum | 3,500 ₹38,010 | 2,460.02 ₹26,715.82 | 2,460.02 ₹26,715.82 |
| 1.03 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand). | 4.19 | Cum | 2,500 ₹31,425 | 1,997.9 ₹25,113.60 | 1,997 ₹25,102.29 |
| 1.04 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) | 8.53 | Cum | 2,500 ₹63,975 | 3,064.31 ₹78,415.69 | 3,064.36 ₹78,416.97 |
| 1.05 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural
sources : 3 graded stone aggregate 20 mm nominal size de
rived from natural sources) | 1.54 | Cum | 5,560 ₹25,687.20 | 3,011.11 ₹13,911.33 | 3,011.11 ₹13,911.33 |
| 1.06 | Soling (or sub base) of well burnt soling bricks including filling of interstices and rolling.(Old size bricks, one layer laid on flat.) | 58.39 | Sqm | 250 ₹43,792.50 | 132.73 ₹23,250.31 | 132.74 ₹23,252.07 |
| 1.07 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) | 99.3 | Sqm | 130 ₹38,727 | 116.75 ₹34,779.83 | 116.75 ₹34,779.83 |
| 1.08 | White washing with lime to give an even shade New work (three or more coats | 99.3 | Sqm | 50 ₹14,895 | 11.68 ₹3,479.47 | 11.68 ₹3,479.47 |
| 1.09 | Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works | 55.77 | Sqm | 110 ₹18,404.10 | 19.8 ₹3,312.74 | 19.98 ₹3,342.85 |
Tender Value
₹42.9 L
EMD Value
₹85,740
Closing Date
1 Dec 2025, 12:00 pmClosed
Executive Officer
Moran Municipal Board, Santipur, ward 4
Construction of material recovery facility and waste to compost pit
2025_UDD_48419_1
MMB.7(3)/A/2015/SBM/P-1/217
Open Tender
Civil Works
Khumtai Bagicha gaon under Mahmora Mouza
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹85,740
Office of the Moran Municipal Board
3 Jan 2026
4 Nov 2025
1 Dec 2025
4 Nov 2025
1 Dec 2025
4 Nov 2025
18 Nov 2025
Amount
Setting up of compost pit (30 Pits) Enter amount for 10 Pits
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in:Cement Mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Soling (or sub base) of well burnt soling bricks including filling of interstices and rolling.(Old size bricks, one layer laid on flat.)
15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
White washing with lime to give an even shade New work (three or more coats
Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes
Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I. plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.
Providing and fixing bolts including nuts and washers complete
Waste receiving Platform
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth up to 50 m and lift up to 1.5 m, as directed by Engineer-in- Charge:
Sand filling under floors or in foundations including watering and consolidation
Soling (or subbase) of well burnt soling bricks including filling of interstices and rolling. (Old size brick , one layer laid flat.)
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size
Estimate Of Electrification For MSW Disposal Site (as per DSR 2021)
Material & Labour Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long)
Eaves gutter and pipes any description,exc 60 cm girth including holderbats, distance pieces, etc. (length measured over bends, branches etc.) Aluminium paint (each coat)
Fixing only street light fitting, for 70/80 watt vapour or sodium vapour lamp, complete with ballast and capacitor comprising of cast aluminium housing, a pair of aluminium reflectors, a highly transparent clear acrylic cover hinged to the canopy at one end and fixed by means of single spring action at the other, suitable for mounting on 40mm or 50mm dia. G.I. mast or bracket arms with pole fixing attachments and fixing of lamp
Supply and fixing of junction box of size280 X 170 X 130 mm with hinges and locking arrangement & MS clamp made of 50 X 6 mm flat complete in all respect.
Supply and laying of following sizes Al. conductor PVC insulated armoured sheathed cable of 1100 V grade at a depth of 750 mm B. G. L. Ditto, but sec area 35 sq. mm. (3 core)
Supply and laying of following sizes Al. conductor PVC insulated armoured sheathed cable of 1100 V grade at a depth of 750 mm B. G. L. Ditto, but sec area 16 sq. mm. (2 core 16 sqm)
supply and fixing of G.I. pipe of 80 mm dia along the pole for protection of underground cable as required
Ditto, but using galvanised iron strip 25×4mm as earthing lead.
Supply and fixing of feeder pillar of M.S cubicle box of size 100 x 75 x 40 cm made from 2 mm M.S sheet using angle of size 40 x 40 x 6 mm duly hinged and locking arrangement, painting two coats of enamelled paint over red oxide primer providing aluminium Bus-bar or suitable size with 100 A/415 V TPN rewirable type main switch with cement concrete foundation providing 1 Mtr GI pipe on 100 mm dia complete in all respects as per direction of E/I.Supply and making of earth main hole of size 1' x 1' and 2' deep with 1' x 1' CI chamber brick work etc
Supply and making of earth main hole of size 1' x 1' and 2' deep with 1' x 1' CI chamber brick work etc
LT panel / Feeder Pillar having one no incoming panel, 5 no.s, outgoing panel and one number change over switch for DG set.
Estimate Of Sepration Chamber (10mx3m)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
GI sheet 0.8 mm thick confirming to IS 277:1992 at bottom
Mild steel plates 2mm thick for front open lid
Welding by gas or electric plant including transportation of plant at site etc. complete.
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete
Electronics Equipments Required At Site
Supply and installation of 1000kg and 100g Accuracy Heavy Duty Steel Platform Digital Weighing Scale including all equipment , materials , complete with all taxes.
Computer with in-built modem & fax software
Printer
Telephone (land line)
Wireless/ Mobile phone
Complaint logbook
Table
Chairs
Estimate of Bailing Machine
Supply and installation of Balling machine of required capacity including all accessories complete as per direction of Engineer-in-Charge
Estimate of Conveyor Belt
Supply and installation of Conveyor Belt of required capacity including all accessories complete as per direction of Engineer-in-Charge
Estimate of MRF Shed (25.00m X 10.00m)
Upto plinth level: Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge.e
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Above plinth Level: Centering and shuttering including strutting, propping etc. and removal of form for Columns
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m²
Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (60.3mm OD hollow pipe)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes (SHS-40 X 40 X 2.6 mm)
Estimate Of Internal Electrification In All Buildings
PVC single core sheathed cable Wiring with copper conductor cables In stove enamelled Stee l Conduit . One light point or one fan point controlled by one switch with cables 1.5 sq. mm size. Group A
PVC single core sheathed cable Wiring with copper conductor cables In stove enamelled Stee l Conduit . One light point or one fan point controlled by one switch with cables 1.5 sq. mm size. Group C
Wiring for light point with 1.5 Sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 2 No 2.5 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit along with 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.75x75x50mm
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.147x93x47mm
supply and fixing following modular base & cover plate on existing modular metal boxes etc as required. 4/5 module
Supply and fixing following modular switch and socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 3 pin 5/6 amp socket outlet
Supply and fixing following modular switch and socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.Telephone socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc as required
supply and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required
Supply and fixing call bell/ buzzer suitable for D.C/ A.C single phase 230 volts complete as required.
Supply and fixing 3 pin, 5 amp. Ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supply and fixing brass batten/ angle holder including connection etc as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length(up to 30 cm) with 1.5sq mm FR PVC insulated, copper conductor single core cable, including providing and fixing phenolic laminated sheet cover on fan box etc as required
Installation , testing and commissioning of prewired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc directly on ceiling/wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc as required.
Installation , testing and commissioning of prewired, fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc. including supplying and fixing ball and socket arrangement 2no down rods of 20mm dia X 1.6mm thick steel conduit up to 30cm length painting and wiring the down rods and connection with 1.5 sq mm FR PVC insulated, copper conductor, single core cable and earthing etc as required.
Installation of exhaust fan up to 510 mm sweep in the existing opening including making the hole to suit the size of the above fan making good the damage connection testing commissioning etc as required.
Extra for cutting and threading of G.I pipe heavy guage down rod for ceiling fan etc. as required
Supply and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc as required. 2way single door
Supply and fixing 6 amps to 32 amps rating 240 volts 'B' series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connection testing and commissioning etc. as required 6/32 amps, single pole B series
Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required
Swapnil Kukurachowa (BID ID -287190)
Radiant Engineering Company (BID ID -288017)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
RFP.pdf
Tender Documents • 1.77 MB
BOQ_76972.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid