Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹80 L
EMD Value
₹1.6 L
Closing Date
19 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, LucknowCantt, Lucknow-226002
Day to Day Comprehensive Repair / Maint of SCV , NSL and RA Bazar MD Accn Incl B/R and E/M Fitting / Fixtures alongwith Cleaning of Manholes septic Tanks and Sewage line Under under GE (East) Lucknow.
2025_MES_737149_1
CWE/LKO/E/T-92 OF 2025-26
Open Tender
Civil Works
Item Rate
270 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE EAST LUCKNOW
₹1.6 L
Yes
28 Oct 2025
28 Oct 2025
26 Dec 2025
28 Oct 2025
19 Dec 2025
27 Nov 2025
28 Oct 2025 - 18 Nov 2025
Cleaning and removing all scale and dirt etc from tank and from mouth of circulating pipe etc of capacity exc 250 n exc 500 ltrs complete all as specified and directed.
S&F 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position incl 20 mm dia float valves all as specified in SSR Part I and including dismantling of existing tank, complete all as specified and directed as in day to day complaints.
S&F, in repair 20mm dia float valve high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball screwed for iron pipe with fly nuts complete all as specified and directed.
S&F in repair gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipe of 20 mm bore complete all as specified and directed.
S&F in repair gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipe of 15 mm bore complete all as specified and directed.
S&F steel water GI tubing 15mm dia medium grade, with all fittings complete to walls and ceilings or laid in floors including taking down of existing GI/PVC pipe complete all as specified and directed.
S&F steel water GI tubing 20mm dia medium grade, with all fittings complete to walls and ceilings or laid in floors including taking down of existing GI/PVC pipe complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed
M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking and binding with Mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Returning filling in trenches including spreading leveling, watering and well ramming in layer not exc 25 cm thick complete all as specified and directed.
Removing of excavated materials to a distance 1.5km and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall incl MS holding clamps complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall incl MS holding clamps complete all as specified and directed.
S&F of 110mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed.
S&F of 75mm bore PVC (SWR) bends,any radius with access door complete all as specified and directed.
M&L for factory made RCC man hole cover /drain cover with cover frame comprising of 75mm thick cover, including provision of hot dip galvanized lifting hook for lifting overall cover with suitable size angle iron frame, RCC cover of M-30 grade concrete by vibro compression process, medium duty confirming to IS-12592 including fixing on manhole, demolition of existing coverwith cover frame and removal of debris from site complete all as specified and directed. Note : The factory made RCC cover shall be ISI marked and as approved.
Dewatering of soak well , septic tanks by using mechanical pump diesel driven with fuel operator and crew of water etc at site all as specified and directed by Engineer in charge.
Cleaning of soak well, septic tanks by way of desludging foreign material manually/mechanically and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off outside of MOD premises (at the location notified by the local Municipal Corporation/ Cantt board as per rules of public health), including digging required nos of pits for depositing sludge and future capping the pit with the 25 cm thick layer of soil and sprinkling bleaching powder (including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
Cleaning of blockage of 150mm bore sewer lines (i.e. branch sewer line, main sewer line) by way of cleaning desludging foreign material as well as roding of sewer line between successive manholes manually/mechanically or pumping out sewage from blocked line including desludging where required and ordered by Engineer-in-Charge and keeping sewer line functional from Ist manhole upto final drop as septic tank, soakage well all as specified and directed .
Cleaning of all manholes upto 3.00 meter depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soil and sprinkling powder ( including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
Cleaning of all manholes upto 1.5 meter depth of any size and removal of sludge/silt/liquid mud sand (in foul conditions) etc, and disposed off out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board) (as per rules of public health), including digging required nos of pits for depositing sludge and furture capping the pit with the 25 cm thick layer of soil and sprinkling powder (including supply of bleaching powder) over the area of ditches with one metre around complete all as specified and directed.
Cleaning of all blockages of Nahni traps/floor traps/bottle traps, blockages of WC's, upto 1st manhole/Gully Trap in shafts, vertical CI soil/waste pipe stacks, CI Tee/door bends etc & cleaning of drain pipes of any dia by rodding and removal of sludge/silt/liquid mud sand (in foul conditions) etc, out of MOD premises (at the location notified by the local Municipal Corporation/Cantt board). To Maintain of internal & external sewage system in functional state at all the time by engaging/deploying minimum One Safaiwala alongwith one Helper from 0900 hours to 1700 hours at Complaint cell of AGE B/R-II area mentioned in the contract on daily basis, with manual/ pressure cleaning pump and flexible rods and other necessary equipments (as per rules of public health), complete all as specified and directed.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
TenderET92.pdf
Tender Documents • 1.36 MB
BOQ_825372.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .