| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹18.9 L+₹59,515 (3.24%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹20.7 L+₹2.4 L (13.0%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹21.8 L+₹3.4 L (18.7%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
1 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI
GE (AF) E/M CHAKERI -208008
REPAIR MAINT OF UG CABLES INCLUDING ALLIED WORKS IN TECH AREA AT AFS CHAKERI, KANPUR
2021_MES_464850_1
8521/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) E/M CHAKERI
₹50,000
Yes
27 Oct 2021
3 Aug 2021
6 Sept 2021
3 Aug 2021
1 Sept 2021
18 Aug 2021
60 days
Amount
Excavation in trenches in soft/loose soil n. exc. 1.5 meter wide and n. exc. 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/stay assembly and laying/taking out cables complete all as specified and directed.
Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc. 50 Mtr and dispositing where directed at a level n. exc. 1.50 Mtr above the starting point complete all as specified and directed.
M & L Sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable) complete all as specified and directed. Note :- Punned thickness only will be considered for payment.
Supplying and laying un-reinforced precast concrete cable covers class HV, Type I, flat, size 300mm x 180mm x 40mm ISI marked complete all as specified and directed.
M&L XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade including taking down of following cross section area complete all as specified and directed. Size of Cable: 300 Sqmm, 3 core cable Make : Havells/Universal/ Gloster/ Polycab.
All as per item No. 6 above but of size 185 Sqmm 3 core cable.
All as per item No. 6 above but of size 120 Sqmm, 3 core cable.
All as per item No. 6 above but of size 95 Sqmm, 3 core cable.
M&L XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 33000 volts grade including taking down of cross section area 300 Sqmm, 3 core cable complete all as specified and directed. Make : Havells/Universal/ Gloster/ Polycab.
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/ walls (suitable size iron clamps with nuts, bolts & washers) under road crossing etc of following sizes including dismantling and taking down existing pipe complete all as specified and directed. Size:- 80 mm bore Make : Jindal/Tata/Prakash Surya/Swastic.
All as per item No. 11 above but of size 100 mm bore.
M & L for boring in any type of soil by mechanical method 1.0 Mtr below the top surface of road complete for passing through 80mm to 100mm dia GI pipe a complete all as specified and directed. NOTE :- Pipe will be measured and paid for separatily. Any damage to existing cables of any type will made good by the tenderer without any extra payment.
M&L for removing of cable duct cover for passing of HT cable after taking/passing of HT cable refixing cable duct cover in same position complete all as specified and directed.
Taking down/ getting out carefully old serviceable/ unserviceable HT under ground cable from trench/duct or fixed on walls or laid in duct/ pipe/re-routing, any size and core after repairing, taking out PCC cable cover from trenches, kept in safe custody for reuse of serviceable cable cover and UG cable, complete all as specified and directed. Note:- (i) Earth work and re-laying of cable include in this quoted rate. (iI) This item shall be applicable for repairing work including in this quoted rate.
Supply & fixing HT PCC cable route indicator of size 175mm x 150mm thick, 75 cm long and upper front side each indicator shall be embracing 4mm deep with words "HT CABLE" and two coats of synthetic enamel yellow and red paint along HT cable trench after every 50Mtr and corner & on any turnning, road crossing etc including planting in ground with PCC (1:3:6) type C-1 using 20mm graded stone aggregate complete all as specified and directed.
M&L in repair pin type, porcelain, vitreous, white or green insulator (HT), 150mm height and 150mm dia, 11000 volts grade including one galvanised MS spindle, two GI washer and one GI nut complete all as specified and directed.
Suuply & Fixing in repair Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for HT 25X20cm size including taking down complete all as specified and directed.
Supply & Fix in repair HT/LT feeder/equipment name plate of 1.6mm thick mild steel sheet, vitreous enameld white, with letters in signal red colour and fixed with MS clamps, bolts and nuts of approved size 30cm x 25 cm complete all as specified and directed.
M&L aluminium conductor steel reinforcesed (ACSR) straining properly on insulator and binding with aluminium tap/ binding with connectors, jumpers etc of any type and sizes complete all as specified and directed.
M&L for detection of fault through fault locating high voltage mobile machine to locate the fault in 11 KV / 33 KV HT cable by giving high voltage surge and to find out exact location of fault complete all as specified and directed. Note : The item includes transportation, fuel charges, charging of machine etc. for full functioning of machine upto detecting fault at a time. Bidder must quote rate considering the fact that he has solely responsible to arrange fault locating machine & he shall not accept any facility from the dept for the same.
M&L for general servicing, repair and maintenance of HT Panel board / RMU by taking shut down, removing of carbon particles, rubbing of heated portion of bus bar, removing moisture (if any) and cleaning complete by means of CRC-226 / Petrol tightening of all joints in bus bar, checking of earth, replacement of unserviceable nuts, bolts, washers etc including replacement of corroded glands, lugs/ thimbles and tightening them properly including control wring for metering and relay complete all as specified and directed.
Supply and fixing in repair cable jointing kit termination for HT 11KV grade cable for straight through joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of following size and testing after jointing complete all as specified and directed. Size:- 50 to 95 Sqmm, 3 core cable. Make :- Reychem/ Denson/ 3M
All as per item No. 23 above but of size 120 to 185 Sqmm, 3 core cable.
All as per item No. 23 above but of size 240 to 400 Sqmm, 3 core cable.
Supply and fixing in repair cable jointing kit termination outdoor type for HT 11KV grade cable for end termination joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of following size and testing after jointing Size:- 50 to 95 Sqmm, 3 core cable. Make :- Reychem/ Denson/ 3M
All as per item No. 26 above but of size 120 to 185 Sqmm, 3 core cable.
All as per item No. 26 above but of size 240 to 400 Sqmm, 3 core cable.
Supply and fixing in repair cable jointing kit termination indoor type for HT 11KV grade cable for end termination joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of following size and testing after jointing complete all as specified and directed. Size:- 50 to 95 Sqmm, 3 core cable. Make :- Reychem/ Denson/ 3M
All as per item No. 29 above but of size 120 to 185 Sqmm, 3 core cable.
All as per item No. 29 above but of size 240 to 400 Sqmm, 3 core cable.
Supply and fixing in repair cable jointing kit termination for HT 33KV grade cable for straight through joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of size185 to 300 Sqmm, 3 core including testing after jointing complete all as specified and directed. Make :- Reychem/ Denson/ 3M
Supply and fixing in repair cable jointing kit termination outdoor type for HT 33KV grade cable for end termination joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of size 185 to 300 Sqmm, 3 core and testing after jointing complete all as specified and directed. Make :- Reychem/ Denson/ 3M
Dismantling, shifting and reinstallation of dismantled HT 11 KV switch gears / VCB / Transformers etc. from sub station to a location as directed but not more than 5 Kms complete all as specified and directed.
Cleaning of power house / sub station along with nearby areas with surface dressing 15 cm deep and cleaning away all grass vegetation saplings, brush wood under grouting, roots & tree and not exceeding 30 cm girth and removing rubbish to a distance of 50 mtr outside the periphery of area complete all as specified and directed.
Earthing complete with galvanized steel plate electrode 60cm X 60cm X 6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanized strip 32 X 6mm size by means of bolts, nuts, check nuts and washer of galvanized iron or of steel, earth lead protected by 40mm dia GI pipe light grade watering pipe 20mm dia GI light grade GI wire messed funnel, alternative layer of charcoal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation and earth work, earth strips connected to HT/LT equipment testing the earthing after completion all as specified and shown in electrical plate No 3 of MES SSR Pt- I 2009 print, complete all as specified & directed.
Earthing complete with galvanized steel plate electrode 60cm X 60cm X 6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.5 Mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel, earth lead protected by 15mm dia GI pipe light grade watering pipe 20mm dia GI light grade GI wire messed funnel, alternative layer of charcoal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation and earth work, earth wire connected to HT/LT equipment testing the earthing after completion all as specified and shown in electrical plate No 3 of MES SSR Pt- I 2009 print, complete all as specified & directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
Supply and Fix in repair First Aid Box with medicine complete all as specified and directed.
Supply & Fix shock treatment chart board with plastic coated and aluminium frame complete all as specified and directed.
Supply & Fix in replacement LED & tin alloy fuse wire suitable for HT supply complete all as specified and directed.
Supply & Fix in replacement of cable lugs of following sizes complete all as specified and directed:- 16 Sqmm to 25 Sqmm.
All as per item No 42 above but of size 35 Sqmm to 70 Sqmm.
All as per item No 42 above but of size 95 Sqmm to 150 Sqmm.
All as per item No 42 above but of size 185 Sqmm to 300 Sqmm.
Supply & Fix in replacement of HT tape standared size on the cable terminals complete all as specified and directed.
Attending breakdown attributable to cable faults, flashover in HT panel / VCB or any of the connected transmission line system & rectifying it in 33 KV / 11KV cable / transmission line network upto end connections with panels / transformers or any of electrical item connected therein at Air Force station, Chakeri Technical & Domestic area during any hours of a day during the currency of contract by engaging sufficient manpower after receiving communication through Complaint Section / Concerned JE / Engr-in-charge either through teleponic call, text message, email or through messanger 24x7 hrs complete all as specified and directed. Note: The occurance of fault if any, will be communicated to the contractor and the contractor shall rectify the same within 12 hrs of reporting, failing to which a recovery @ Rs 500/- per complaint per day and maximum of Rs 10,000/- shall be recovered from contractor's payment. Contractor shall be bound to arrange his resources accordingly and the quoted rates shall be deemed to include the same. Further, all necessary equipment like HT megger, hand gloves, line testers, earth rod etc shall be readily available with the contractor's manpower under his own arrangement. Delay on account of non availability of such items shall not be considered for relaxation.
M/S DARSHAN ENGINEERING WORKS
Bharat Sales Corporation
ashokcontractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .