| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC Based on prices offered by M/s. V Cube Electricals, Pune is found to be lowest. Mentioned price is inclusive of applicable GST. | |
| 2 | L2₹13.9 L+₹2.1 L (17.8%)Rejected-AOC PUNE | PUNE | MAHARASHTRA | 410301 | L2 | Rejected-AOC NOT AWARDED L2 BIDDER | |
| 3 | Rejected-Technical | - | Rejected-Technical Only responsive, compliant bid accepted for further processing | |
| 4 | Rejected-Technical | - | Rejected-Technical Only responsive, compliant bid accepted for further processing | |
| 5 | Rejected-Technical | - | Rejected-Technical Only responsive, compliant bid accepted for further processing |
Tender Value
Refer Docs
Closing Date
9 Apr 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VIVEK SARATKAR
CDAC PANCHWATI PASHAN PUNE
Supply, Installation and commissioning of LT Electrical and Allied Works at first floor e-Sign room at C-DAC, Pune, as per terms and conditions specified in this document
2021_DIT_624323_1
CDACP/eSign-Elect/2021
Open Tender
Electrical Works
Turn-key
45 days
Pune
As per tender document
2 documents required · 2 mandatory
₹500
CDAC
Exempted
ONLINE
23 Jul 2021
25 Mar 2021
9 Apr 2021
25 Mar 2021
9 Apr 2021
25 Mar 2021
25 Mar 2021 - 30 Mar 2021
31 Mar 2021
120 days
Amount
ELECTRICAL WORK
SITC of 4C X 35 Sqmm copper flexible FRLS cable for RAW power connection from floor electrical room to RAW power DB including gland and other necessary required accessories with ferolling/Nomenclature plate
SITC 4C X 10 Sqmm copper flexible FRLS cable for UPS power connection from floor electrical room to UPS power DB including gland and other necessary required accessories with ferolling/Nomenclature plate
Supply, Installation, Testing & Commissioning of following type Distribution board surface / flush mounted with Double Door MCB DBs. The DB shall have appropriate no. of top & bottom knock outs for outgoing circuits & shall be complete with necessary bus bars, interconnection terminals & earth studs. All terminations in DB shall be complete with ferruling, dressing & all circuits shall be properly labeled with PVC strip (sticker type) having identification
SITC of UPS 6 Way TPN DB (Double door) including 1 no's of 4P 63 Amp MCB's ,8 nos of SP 10/16 Amp MCB, 4P 63 Amp 2 nos MCB
SITC of RAW power 6 Way VTPN DB (Double door)including 1 nos of 4P 125Amp MCCB incomer ,4nos of 4P 63Amp MCB for outgoing ,3 nos of SP 32 Amp MCB for outgoing, 2 nos 25Amp SP MCB for Cassette AC
SITC of 125 Amp MCCB including encloser box and necessary required accessaries with connection from nearest panel(Electrical room)
UPS Point Wiring for Access control point for 6/10A,2/3 Pin 1 Sockets 01 Switch 6A wiring point consider to wall, CCTV electrical point, rodent repellent and water leak detector system electrical point, for dehumidifier , fire alarm panel, points for PCs with all required accessories The rate should include circuit wirings. The earth puls 2 wire to be of yellow, Black,-green color only.(Circiut wiring to be minimum 2.5Sqmm from DB to 1st point )Maximum 2 Secondary to be looped from 1 primary
SITC UPS point wiring for Primary 5A switch socket using 2 x 1.5 Sq.mm copper Flexible conductor PVC insulated wires in PVC conduits pipe of 25/20mm dia. , concealed in wall (including Chiesling in wall) and or through partitions with necessary boxes, Ceiling rose, 6A modular type switch, and socket mounting plate and concealed Metal Box and proper clamping complete, making good in all respect.
SITC UPS Secondary point wiring for 5A switch socket using 1.5 sq.mm copper conductor PVC insulated wires with 6A modular type switch and socket, mounting plate and concealed Metal Box and proper clamping complete ,concealed in wall (including Chiesling in wall)& later making good in all respect.
SITC UPS point wiring for Primary light points using 2 x 1.5 Sq.mm copper Flexible conductor PVC insulated wires in PVC conduits of 25/20mm dia, surface mounted on ceiling, concealed in wall (including Chiesling in wall)and or through partitions with necessary boxes, Ceiling rose, 6A modular type switch, mounting plate and concealed Metal Box and proper clamping complete .( including circuit wiring) .The wiring points shall be with extension of earthing to all the points.
SITC point wiring for Secondary light points using 2 x 1.5 sq.mm copper Flexible conductor PVC insulated wires in PVC conduits of 20mm dia. , surface mounted on ceiling, concealed in wall and or through partitions with necessary boxes, Ceiling rose and proper clamping complete ( including circuit wiring) .All the point wirings shall be along with necessary earthing arrangements.
Supply and installation of HMS MS (20 mm) conduit including chiseling to wall for concealed fitting with all necessary accessories like clamp, saddle etc. as per specification
Supply and installation of LED down lighter of 15 watt (Phillips or equivalent)
Supply and fixing of GI perforated cable trays, fabricated out of 16 Swg GSS, with supports, fittings etc. complete for the size -150 mm width x 50mm
Supply and fixing of GI perforated cable trays with cover, fabricated out of 16 Swg GSS, with supports, fittings etc. complete for the size -150 mm width x 50mm
Supplying and laying of 6 SWG Copper flexible wire for earthing of equipment and motors.
RODENT REPELLENT SYSTEM
SITC of Rodent Repellent Panel Capacity Upto 12 Transducers/Satellite in each Panel
SITC of Satellite Stations / Transducers covering minimum 450 sqft
SITC of 25 mm PVC Conduit for laying cables
SITC of 2 x 1 sq mm Cable.
ACCESS CONTROL SYSTEM
SITC of Double user simultaneous authentication and Biometric cum card reader system Access Control Panel with onboard TCP/IP, Supports Standard Wiegand Reader with Metal Enclosure & inbuilt Power Supply (provision for 2 hr Battery Backup, ) Specifications of Access Control System (1) Access control system with 6 biometric devices to be installed and commissioned at C-DAC Pune. (2) The access control systems are to be placed to control the opening of the three doors. (3) The doors should open (for all three doors) only after successful authentication. (4) The device should support single and dual authentication (minimum two individual persons). (5) There should be time syncing of biometric devices and controller with C-DAC NTP server. (6) The system should support integration of biometric controller with Fire suppression panel. (7) The biometric devices should support the with PIN, card and fingerprint (8) The biometric devices should have built-in card reader along with the keypad (9) The devices should have capacity to register minimum 100 finger prints. (10) The devices should be able to identify only live fingerprints using pulses and blood flows of the finger (11) Should supply software for management and monitoring , it should compatible with windows OS (12) Supply should include the all software with perpetual licenses. (13) Should have Ethernet (RJ45) port to communicate with supplied Software for storing of records, logs and events and all logs and events should able to monitor from desktop machine (Windows). (14) Country of Origin (COO) / Country of Assembly (COA) should be provisioned for the quoted products. The C-DAC reserve rights to accept or reject the bid based on (15) 24x7 support with 4 hours of resolution time. To meet 4hrs resolution time provide support mechanism. (16) Support should include firmware upgradation, system and security patches. (17) Bidder need to supply the software to manage and configure the supplied biometric controller and readers. Software shall support mapping of single user, pair of users (Min.10) to authenticate for opening the door. (18) Supply should include all the necessary mounting brackets, hardware, power and data cables.
SITC of proximity Cards ( Blank)
SITC of Electromagnetic Lock (600 Lbs) suitable for DOUBLE LEAF Door with door position sensor & necessary accessories
SITC of Door Sensor
SITC of cat 6 cable with 25 mm PVC Conduit for laying cables
Supply,installation,testing & commissioning of IP Dome Camera 2MP H.265 Specifications of IP camera: • Camera must provide at least 160 degree angle view. • Minimum 2 Megapixel resolution • Minimum Sensitivity of Day: 0.5 Lux; Day/Night: 0.5 lux color / 0.05 lux • White Balance Mode: Auto; Fluorescent; Indoor; Outdoor • H.265 compression • Streams must guarantee minimum full frame (25fps/30fps) rate under high motion and all conditions. • Intelligent Motion Detection and Object tracking • The camera should configurable remotely. • IP Cameras output should be compatible with the quoted Network Video Recorder (NVR) solution. • IP Camera should support Power on Ethernet (POE) • Cameras must be ceiling mountable and tamper resistant/evident/proof
SITC of Cat 6 cable D LINK or equivalent in flexible /rigid conduit
SITC of 16 Channel NVR H.265 with 20 TB harddisk 80 MBPS bandwidth minimum with 16 Port/2x8 PORT POE Switch Network , 10/100Mbps RJ45 ports, 1, 100M Ethernet Port Network ProtocolIEEE802.3,802.3u,802.3x, 802.3af, 802.3at. Specifications of Network Video Recorder (NVR) solution. • Video Operation Codec Management, Recording and Processing Software • NVR should be scalable, should offer a complete Video Surveillance solution that will be scalable to minimum 9 cameras that can be added as and when required. • All upgrades and releases should be made available free of cost during warranty/AMC period. • The system should allow for live view, playback and system configuration of the IP video system. • Should support to create custom layout by grouping of cameras for more efficient monitoring. • Several simultaneous live picture connections of camera in network. It should be capable of showing video pane layouts including 2x2, 3x3, 4x4, 5x5, 8X8 various Hot Spots (1+5, 1+7, 1+9, 1+12, 1+16) and custom layouts • The live view must be capable of highlighting motion as colored (e.g.: Green) rectangle overlays on the live video feed. • The proposed system should be capable of exporting recorded files into video file formats (like .wmv/ .img. etc) playable in windows media player and VLC media player for defined period of time. • Surveillance storage of 20 TB after implementing RAID 5 • Should support recording of data of 9 cameras (of the above quoted camera type) over IP • Should have provision for remote access management • Rack mountable, maximum 4 U size appliances along with rack mounting equipment / brackets etc. • NVR Solution including Software and Storage
Intrusion Detection System
Supply & Installation of Power Panel With Metal Cabinet, 8 on-board zones, Expandable to 32 wireless and hardwired zones, 2 PGSM output: expandable to 38, 8 partitions, 500 event buffer and 500 user codes
Supply & Installation of Lock & Key for Metal cabinet
Supply & Installation of 220V CE TRANSFORMER
Supply & Installation of BATTERIES 12V-7AH for Backup
Supply & Installation of Shock/Vibration sensor
Supply & Installation of Full message Lcd keypad
Supply & Installation of GSM Dialer
Supply & Installation of POWERSERIES NEO INTERNET COMM for MOBILE APP
12V Siren and Strobe for indoor use
Supply & Installation of 4C x 1 Sq mm cable cu flexible cable through conduit
Supply & Installation of Commissioning Charges
FIRE PROTECTION AND ALARM SYSTEM
Supply, installation, testing and commissioning of Response indicator for all detectors located above false ceiling
Intergration of fire alarm system of E-sign room with building main fire alarm system.
SITC of fire cable -1.5 Sqmm x 2C copper armoured cable
Suvarna Electricals Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .