Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹49.4 L+₹51,070 (1.04%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹51.7 L+₹2.8 L (5.72%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BANGALORE | BANGALORE | KARNATAKA | 560085 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
3 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
PROVISION OF CERTAIN SANCTIONED INCLUDING MINOR WORKS AT AFS JALAHALLI AND AFTC
2024_MES_668905_1
8947/E8
Open Tender
Electrical and Maintenance Works
Item Rate
181 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹1 L
11 Nov 2024
31 Aug 2024
10 Oct 2024
31 Aug 2024
3 Oct 2024
14 Sept 2024
31 Aug 2024 - 7 Sept 2024
Amount
M&L for anodised aluminium snap grid frame work for false ceiling of size of grid 605 x 605mm or as per manufacturer's instruction including necessary scaffolding, notching and prepared holes complete all as specified and as directed
M&L for hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long, provision of PVC protected sheeting and its removal after fabrication and supporting hanger comprising of mild steel rod, J bolt with necessary washers, bolts and nuts, for securing frame work to ceiling and to the snap grid complete all as specified and as directed
M&L for providing 12mm thick seamless calcium silicate fire proof ceiling made out of required size board of siliceous and calcareous material reinforced with cellulose fibre, meets fire ratings as per BS 476 Part 5, 6 and 7 class 1 and P, water resistant and thermal insulated, tested as per fire retardant IS 15061-2002 for excellent results, fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish all as per manufacture instruction complete all as specified and as directed. (Frame work for ceiling shall be measured and paid separately) Note: Contractor has to submit fire resistant/retardant certificate of ceilling from the manufacturer alongwith sample approval .
Supply and install single phase 230V automatic AC load manager suitable for 2TR split AC for auto on/off of 2 Nos AC complete with timer,contactor,Internal wiring etc. including connection of incoming and out going cables complete all as specified and directed. Make: Universal Refrigeration and Engineering or equvalent
Supply and install three phase 440V automatic AC load manager suitable for 4.5TR vertical type split AC for auto on/off of 3 Nos AC complete with timer,contactor,Internal wiring etc. including connection of incoming and out going cables complete all as specified and directed. Make: Universal Refrigeration and Engineering or equvalent
Supply and fix MCB single pole 6 to 32 Amps 240 volts,'C' curve, 10 KA rupturing capacity including connection complete all as specified and directed.Make : Legrand/ L&T/ Indo Asian
S&F Metal clad socket 20 Amps single pole and neutral enclosure with 2 pin and earth plug and socket complete with sheet steel enclosure and controlled with and including 1 No. single pole MCB SP 20 Amps Complete all as specified and directed.Make : Legrand/ L&T/ Indo Asian
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 6 Sqmm drawn through in and incl suitable size surface PVC Conduit /concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed. Note: (a) 2 runs of 6 Sqmm cable along with one run of 6 Sqmm cable for earth conductor shall be measured as one length . (b) Connections of cables with MCBs or bus bars shall be done through appropriate size copper thimbles. Make:- Havells/ Plaza/Polycab
Supply, installation,commissioning and testing of factory assembled ,floor mounted ,free standing type tested LT Feeder pillar panels,with canopy ,as per electrical specifications for outdoor installation to be made of IP65 Polycarbonate modular enclosures. The enclosures made of polycrabonate,should be weather vermin proof, anti -acid,anti-corrossive,UV resistance in accordance with IEC 61439-1,fire retardant and self extingushing in accordance with IEC 60695-2-11 ,UL subject 94 for flammability V-0, should pass glow wire test for 960 degree in accoardance with 60695-2-11.Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262,IP65 in accordance with IEC-60529 and IEC- 60439-1, should have dielectric properties ,RoHS compliants & Halogen free. The manufacturer of boards/panels shall submit a copy of type test reports as per above mentioned norms either from UL/ERDA/CPRI/NABL labs in india.The panel should be modular and compartmentalized in construction with opaque and transparent doors, properly tight to base with thromoplastic screw having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosuser should be minimum 200mm for air circulation & to minimize temp rise. Panel shall be fitted with one No. of polycarbonate IP 65 9 W LED transperent bulk head luminaire 6500K,PF > 0.95 under canopy for easy maintenance . Panel should be fitted outside with one No. of 16 Amp 3 Pole IP65 industrial socket and 01 No. of 32 Amp 5P IP 65 industrial socket. 3 Phase and neutral 400 Amp current carrying capacity of aluminium bus bar insulated with colour coded heat shrinkable sleeves with SMC/DMC insulators,complete with the following swtich gears and mounting the panel board on ground with PCC (1:3:6) type C-1 using 20mm graded stone aggreate for bedding upto a height of 45 CM above ground level ,including dismanting and taking out old U/s LT panel board and reconnecting existing LT UG Cable with new panel board, complete all as specified and directed :-
(a) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 200 Amp, 25 KA - 01 No (Incomer). (b) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 100 Amp, 10 KA - 02 Nos(O/G). (c) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 63 Amp, 10 KA - 03 Nos(O/G). (d) MCCB with thermal magnetic release 4 Pole, 415 V of capacity 32 Amp, 10 KA - 03 Nos(O/G) (e) Multifunction Meter (V,I,PF) with suitable capacity of CT's - 01 No. (f) Indicating lamp (R-Y-B) set LED type with backup MCB for 3 Phase Supply - 01 set (g) Space for spare feeder - 01 No. Note :- (i) The Contractor shall submit the drawing for approval of GE before executing the work. (ii) Insulators, bus bar sleeves, lugs, gland etc including complete wiring with suitable size of copper wire are all inclusive in unit quoted rate. (iii) Make of Switch gear : Schneider/L&T/C&S. (iv) MCCB should be ICu =100% ICs. (v) Make of LT Panel/FPB shall be as per mentioned in list of makes (PS).
Material and labour for shifting of 2 TR,single phase split type Air Conditioner from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed. Note :- The rate for following works deemed to be included in quoted rate :- (a) Taking down and transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoor units of split ACs with copper tubes, flair nuts, warping suction and discharge lines with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipe of suitable size to drain out dew water with necessary clamps.. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including suitable length of PVC copper cables of 4 Sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas. (j) Fixing of copper tubing of required size and qty as per site requirment. (k) supply and fixing of stand for outdoor unit.
Material and labour for shifting of 4.5 TR,three phase vertical split type Air Conditioner from existing location to new location as per user requirement and installing, toping up of gas, replacement of copper tubing connecting up, commissioning and testing complete all as specified and as directed. Note :- The rate for following works deemed to be included in quoted rate :- (a) Taking down and transportation of air conditioner any type any capacity from one to other location. (b) Fixing only base plate with necessary fixing material on stone / brick walls as directed (c) Fixing only outdoor and indoor units as required and directed (d) Connecting indoor / outdoor units of split ACs with copper tubes, flair nuts, warping suction and discharge lines with necessary fixing arrangements such as bolts, nuts washers and clamps etc. on walls (e) fixing PVC pipe of suitable size to drain out dew water with necessary clamps. (f) Fixing of wall mounting voltage stabilizer of 3 KVA to 5 KVA capacity on the wall with necessary fixing arrangements such as bolts, nuts washers and clamps etc on wall. (g) Fixing PVC hose/ PVC pipes of 15mm sizes as reqd at site with necessary junction boxes, PVC bends etc. including suitable length of PVC copper cables of 4 Sqmm size for electrical connection of ACs. (h) No additional payment shall be made for leakage of gas occurring during shifting of Air Conditioner and topping up of required gas. (j) Fixing of copper tubing of required size and qty as per site requiremnet. (k) supply and fixing of stand for outdoor unit.
S&F Metal clad socket 32 Amps triple pole and earth enclosure with 3pin and earth plug and socket complete with sheet steel enclosure and controlled with and including 1 No. triple pole MCB TP 32 Amps all as specified and directed.Make : Legrand/ L&T/ Indo Asian
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 Sqmm drawn through in and incl suitable size surface PVC Conduit/ existing concealed conduit and all accessories fixed to wall/floors along with 6 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed. Note: (a) 4 runs of 6 Sqmm cable along with two run of 6 Sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size copper thimbles. Make:- Havells/ Plaza/Polycab
Supply and fix energy efficient 5 Star new 25 liters capacity electrical geyser white/half white, copper container inner tank with fiber reinforced body (FRB) puff insulation for both inner tank & for hot outlet copper connection pipe with all in built in safety accessories like thermostat/automatic thermal cut out with ON /OFF /CUT out indicators ,long life heateing element of wattage 2 KW eletrically operated AC 230 Volt and all pre-wired and additional safety accessories like pressurer release valve/presure reducing valve, non return valve, rate shall be including for new PVC heavy duty pipe with brass ferrule fitting for HOT and COLD water connections as per manufacturers instruction with suitble size nuts & bolts, making necessary connection & testing on completion complete all as directed. Make- Havells / Bajaj/Racold
M & L for heat resistant PVC braided connection pipe 15 mm bore with brass coupler as in connecting pipe of geyser, length 300 mm complete all as specified and as directed.
S & F bib tap cast copper alloy chromium plated, fancy type screwed down with screwed both ends for iron pipe 15 mm bore complete all as specified and as directed.
S&F Stop valves, 15mm dia cast copper alloy,screwed down, high pressure,with crutch or butterfly handle,screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated complete all as specified and as directed.
M&L for point wiring using approved colour coding as per IS for one shocket controlled by one way 16 A switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 4.00 Sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn PVC through Casing Capping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 4.00 Sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly, complete all as specified and as directed. Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely.
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 Amps, complete all as specified and directed. Make : Anchor, Havells, L&T
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 2 runs of 4 Sqmm drawn through in and incl suitable size surface PVC Conduit /concealed conduit and all accessories fixed to wall/floors along with 4 Sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly complete all as specified and directed. Note: (a) 2 runs of 4 Sqmm cable along with one run of 4 Sqmm cable for earth conductor shall be measured as one length . (b) Connections of cables with MCBs or bus bars shall be done through appropriate size copper thimbles. Make:- Havells/ Plaza/Polycab
Supply and fix sheet metal enclosure distribution board SPN, 2 way 240 volts, without bus bar, with IP 42 protection and Double Door, suitable for mounting MCBs, complete all as as specified and as directed. Make : Legrand/ L&T/ Indo Asian
Supply and fixing 32 Amp SPN (single pole & neutral) rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning. all as specified and as directed. Make : Legrand/ L&T/ Indo Asian
M&L for point wiring complete with 2.5 Sqmm single core PVC insulated, unsheathed FRLS 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Casing Capping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 2.5 Sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets will be measured and paid for separetely). (b) Modular cover plates includes in the quoted rates.
Supply and Fix modular switch 1 way 16 Amp.1 module, complete all as specified and directed.. Make :Legrand/ Crabtree/ Anchor
Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module, complete all as specified and directed.. Make : Legrand/ Crabtree/ Anchor
Supply, install, testing and commissioning of Chemical Dosing system having top dia 540mm x bottom dia 480mm x height 575 mm, net capacity 95 - 100 Ltr consisting of (i) water inlet line (ii) Dosing pump inlet arrangement (iii) Drain (iv) Overflow (v) Level Gauge (vi) inspection port (vii) Agitator 120 watt 800 - 900 RPM Single Phase flange mounted motor with plastic shaft and impeller (ix) provision of mounting Pump on Lid/wall along with dosing Injector of the following specification. Adjustble dosing pump max pressure 5kg/cm square & max flow rate 0 - 50 ltr / hr including all accessories such as Lead tubing, Connecting Ferrules, check valves, non return valve all as directed. Power input 230V, 50 Hz, 40 SPM 1/30 fractional Horsepower, etc complete all as specified and directed. Make: - Model No. VST 1011 of Ravi Enterprise or equivalent as per E-in-Cs make approved. Note: Unit quote rate shall be inclusive of taking down of old unserviceable plant and depositing same to MES store yard .
Supply and lay Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed to walls, ceilings or in floors etc pipe of 20 mm size complete all as specified and directed.
Supply, Install, testing and Commissioning of centrifugal pump set of capacity 100HP having suction and delivery size as per OEM , discharge 5050 LPM and 50 meter Head,Totally enclosed fan cooled continious duty squirrel cage induction motor with horizontal split case pump with casing CI with suitable pressure gauges ,bronze impeller, ss shaft ,gland packing,coupling guard,coupled base frame with PCC foundation and connected accessories complete including testing, connections taking down old unsv pump and depositing to MES store yard. Make : Kirloskar / Crompton / KSB
M & L for laying/fixing on floor centrifugally cast MS pipe medium grade of size 200 mm bore conforming to IS 1239 with necessary supports and including consumables and painting with one coat of red oxide primer and two coat of synthetic enamel paint including making good the disturbed surfaces of wall/ ceiling etc complete all as specfied and directed.
M&L for MS bends,tapers,tee pieces,cross,collars,caps and plugs any type,raducer and angle for pipes up to 200 mm bore confroming to IS-1239 complete all as specified and directed.
S & Fix fully automatic star delta 3 phase 6 terminal 415v , 50 Hz suitable for 100 HP pump set with suitable adjustable OLR relay , along with single phase preventer including mounting on wall/floor , testing , connecting up cables with proper termination , all connected accessories all as specified and directed Make : L&T/ ABB /Havells / BCH
S&F sluice valve of size 200 mm dia cast iron body ISI marked with flanged ends PN-1.6 with spindle and check nut including operating wheel etc. and fixed with bolts, nuts, washers and rubber insertion packing complete all as specified and directed
S & F Non return valve (NRV) ISI marked, gun metal body suitable for 200 mm dia pipe line including fixing arrangement, complete all as specified and directed.
Supply, Install, testing and Commissioning of centrifugal pump set of capacity 60HP/45KW having suction and delivery as per OEM , discharge 3783 LPM and 40 meter Head,Totally enclosed fan cooled continious duty squirrel cage induction motor with horizontal split case pump with casing CI with suitable pressure gauges ,bronze impeller, ss shaft ,gland packing,coupling guard,coupled base frame with PCC foundation and connected accessories complete including testing, connections taking down old unsv pump and depositing to MES store yard. Make : Kirloskar / Crompton / KSB
M & L for laying/fixing on floor centrifugally cast MS pipe medium grade of size 150 mm bore conforming to IS 1239 with necessary supports and including consumables and painting with one coat of red oxide primer and two coat of synthetic enamel paint including making good the disturbed surfaces of wall/ ceiling etc complete all as specfied and directed.
S&F sluice valve of size 150 mm dia cast iron body ISI marked with flanged ends PN-1.6 with spindle and check nut including operating wheel etc. and fixed with bolts, nuts, washers and rubber insertion packing complete all as specified and directed
S & F Non return valve (NRV) ISI marked, gun metal body suitable for 150 mm dia pipe line including fixing arrangement, complete all as specified and directed.
S&F fully automatic star delta 3 phase 6 terminal 415v , 50 Hz suitable for 60 HP pump set with suitable adjustable OLR relay , along with single phase preventer including mounting on wall/floor , testing , connecting up cables with proper termination , all connected accessories all as specified and directed Make : Make : L&T / ABB / Havells / BCH
M & L for laying/fixing on floor centrifugally cast MS pipe medium grade of size 100 mm bore conforming to IS 1239 with necessary supports and including consumables and painting with one coat of red oxide primer and two coat of synthetic enamel paint including making good the disturbed surfaces of wall/ ceiling etc complete all as specfied and directed.
S&F sluice valve of size 100 mm dia cast iron body ISI marked with flanged ends PN-1.6 with spindle and check nut including operating wheel etc. and fixed with bolts, nuts, washers and rubber insertion packing complete all as specified and directed
Taking down ceiling fan,sealing cable end for replacing down rod with Anti suicide down rod complete all as specified and as directed.
Hanging/Fixing only ceiling fan and connecting the cable from ceiling rose or connector to fan including any addn/alteration if required to down rod complete all as specified and as directed.
Removing and Refixing of light fittings/smoke detectors of any size and any capacity including disconnecting and connecting the cables all as specified and as directed. Note :- An amount of Rs 4700.00 on account of credit schedule for schedule 'A' part II shall be deducted from the total amount of BOQ to arrive at the contract sum.
devan enterprises (BID ID -3119032)
Lucky Enterprises (BID ID -3127153)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .