Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹39.5 LAccepted-AOC GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | 1 | Accepted-AOC L-1 | |
| 2 | 2₹41.4 L+₹1.9 L (4.73%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹42.4 L+₹2.9 L (7.45%)Rejected-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹48.7 L+₹9.2 L (23.3%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 | |
| 5 | Rejected-Technical WZ 1043 C IIND FLOOR NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | - | Rejected-Technical Due to not enlisted in eligible Cat |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
25 Oct 2021, 6:00 pmClosed
GE EAST LUCKNOW
GE EAST LUCKNOW
PROVN OF RAMP FOR VEHS WASHING AT 215 FD WKSP COY AND PROVN OF EXHAUST FANS IN JCO OR MD ACCN UNDER GE (EAST) LUCKNOW
2021_MES_478409_1
GE/E/LKO/T-44 OF 2021-22
Open Tender
Civil Works
Works
120 days
Lucknow Cantt
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
GE EAST LUCKNOW
₹94,000
Yes
23 Nov 2021
28 Sept 2021
26 Oct 2021
28 Sept 2021
25 Oct 2021
12 Oct 2021
Amount
Surface excavation in soft/loose soil not exc. 30 cm deep and averaging 15cm deep and getting out soil complete all as specified and directed
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for foundation, trenches etc and getting out in soft/loose soil complete all as specified and directed
Removing of excavated materials to a distance not exc 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed
Earth filling under floor including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed. Note : Earth obtaind from excavation under item No 1 & 2 shall be used.
M&L for cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundations filling, sub base and mass concrete filling, etc complete all as specified and directed
Excavation over area, n exc 1.5 m deep and getting out in soft/ loose soil complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over as in reinforcement cut to length, bent in shape required including cranking, bending, spirally hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed
All as per item No 8 above but TMT bar 6 mm to 8 mm dia.
All as per item 8 above but 6 mm dia and over up to and including 10 mm dia as in stirrups, spacers and binders
M&L for RCC 1:1½ :3 type A1 (using 20 mm graded stone aggregate) as in foundations, footings, plinth beams; bases for columns etc.complete all as specified and directed
M&L for RCC 1:1½ :3 type A1 (using 20 mm graded stone aggregate) as in Column, pillars, piers, posts and struts etc complete all as specified and directed
M & L for RCC 1:1½ :3 type A1 (using 20 mm graded stone aggregate) as in roof slabs, shelves etc all as specified and directed.
M & L for RCC 1:1½ :3 type A1 (using 20 mm graded stone aggregate) as in chhajas complete all as specified and directed
M & L for RCC 1:1½ :3 type A1 (using 20 mm graded stone aggregate) as in Roof beam, bands, lintel beam, etc complete all as specified and directed
M&L for formwork to sides of concrete in foundations, footings, bases of columns, sides and soffits (if any) plinth beams, and similar work complete all as specified and directed
M&L for formwork to sides of concrete of pillars, posts, struts, piers, columns etc complete all as specified and directed
M&L for form work to soffits of roof slabs, floor slabs and similar work n exc 200 mm thick fair finished surfaces (flat).
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and directed
M&L for formwork to edges of concrete flats, roofs and sides of RCC/ PCC bands in walls, and similar work exc 20cm wide complete all as specified
M&L for formwork to edges of concrete flats, roofs and sides of RCC/ PCC bands in walls, and similar work exc 10cm but n exc 20cm wide complete all as specified
M&L for formwork to edges of concrete flats, roofs and sides of RCC/ PCC bands in walls, and similar work exc 5 cm but n exc 10cm wide complete all as specified
M&L for brick work with fly ash bricks, straight or curved on plan exc 6M mean radius, old size brick built in cement mortar 1:6 complete all as specified and as directed.
M&L for plastering 15 mm thick in CM 1:4 on fair faces of brick or concrete surfaces, finished the surface even and smooth with using WPC @ 2% by weight of cement complete all as specified and as directed. Note- WPC shall be measured and paid separately.
M&L for PCC 1:5:10 type E-2 using 40 mm graded stone aggregate as in foundation filling/sub-base to floor etc and mass concrete complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection laid in bays not exc 1.5m with expansion joints 30x10mm filled with mixture of hot bitumen and sand, finished the surface even and smooth without using extra cement complete all as specified and directed
M&L for hard core broken stone of gauge n. exc. 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, water and rammed to a true surface complete all as specified and directed.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for preparation the new plastered surface of wall including cornices etc and applying two coats of cement base paint (any colour as approved) complete all as specified and directed.
S&F for 15mm dia tubes medium grade galvanised, with all fitting and fixed complete to walls/ ceilings/ concealed or laid in floors all as specified and directed
S&F 20 mm Tubes medium grade galvanised with all fitting and fixed complete to walls/ ceiling / concealed or laid in floors complete all as specified and directed
S&F 20 mm dia brass gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for cement concrete type B-1 1:2:4 as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets, copings, surface channels and drains, benching of man holes, laid to shape and slope and the like including weathering, slightly rounded or chamfered edges and throating, as directed
M&L for PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 150mm dia of pipe complete all as specified and directed
S & F for reinforcement concrete pipes 150 mm dia class NP-2, laid and jointed complete with coller all as specified and directed.
M&L for providing pre-cast RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for man holes and drains) including necessary form work set in CM 1:4 complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block 80 mm thickness M-40 Grade any shape and size confirming to IS 15658-2006 over and including 25 mm thick sand complete all as specified and directed.
Supply, laying, testing and commissioning LT underground XLPE insulated, armoured heavy duty electric cable with aluminium stranded conductor, 1100 volt grade conforming to IS-1554 and ISI marked of cross sectional area 10 Sq mm 2 core size in trenches, on wall, road crossing through protection pipe etc. complete all as specified and directed.
M&L for sand cushioning with dry fine sand including filling, spreading, levelling in layers in cable trench with approved quality of sand for protection of under ground cable complete all as specified and directed.
Supply and laying 40 mm bore galvanised steel tubes light grade with all fittings laid in trenches for cable protection complete all as specified and directed.
Supply and laying common burned clay bricks sub class B designation of old size bricks as cable protection complete all as specified and directed.
Supply, fabrication, testing and commissioning of LT electrical outdoor distribution panel board floor mounted cubical type dust proof, weather proof, vermin proof, astehically designed, having atleast IP-65 degree of ingress protection, fabricated from 2mm thick CRCA sheet with front and rear opening including bus bar chamber, continuous GI strip earth bus bar 2 strips of aluminium bus bar 200 Amps capacity, insulated colour sleeves, porcelain/epoxy insulators, rail channels cable alloy, danger notice board including made out of 14 gauge MS sheet over angle iron frame of size 40 x 40 x 6mm, 30 cm grouted in ground floor and 30 cm above GL including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder caoted painted of approved colour connecting incoming & outgooing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated for retardant copper conductor cable complete. The panel shall be comprising of the following :- (i) MCB 32A SPN -01No (ii) MCB SP 16A-02 Nos
Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.
Supply and fix PVC air freshner fan 250 mm sweep AC single phase, 230/240 volts 50 Hz with louvers and making connection from ceiling rose with twisted copper flexible wire 23/0.076 mm complete all as specified and directed. Make:- Havells/Bajaj/Usha
Supply and fix exhaust fans single phase 230/240 Volts heavy duty metalic body of size 300 mm sweep 1400 RPM ISI marked, and making connection with twisted copper flexible wire 23/0.076 mm all as specified and directed. Make/Model:- Havells Turbo Force SP / Almonard 300 mm Heavy Duty / Bajaj Maxx Air as approved by GE.
Cutting holes in any type of wall for fixing of exhaust fan any size or sweep and making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified and directed.
Material and labour for one fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed.
Supply and fix switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
shiva enterprises
R K CONTRACTOR AND SUPPLIERS
rajan construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .