Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-Finance | L1 | Accepted-Finance Accepted | |
| 2 | L2₹23.2 L+₹28,350 (1.23%)Accepted-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Accepted-Finance Accepted | |
| 3 | L3₹24.3 L+₹1.3 L (5.83%)Accepted-Finance RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Accepted-Finance Accepted |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
25 Aug 2022, 6:00 pmClosed
GE (P) AF Gurgaon
GE (P) AF Gurgaon Near Atul Kataria Chowk Gurgaon
CA NO. GE(P)AF/GUR-53/2022-23 REPAIR / MAINTENANCE OF SOLAR HEATERS, ELECTRIC GEYSERS AND OTHER CONNECTED ITEMS AT AF STN PALAM UNDER GE(P) AF GURGAON
2022_MES_541395_1
GE (P) AF/Gur-53/2022-23
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (P) AF Gurgaon
All as pe NIT
10 documents required · 10 mandatory
₹500
GE (P) AF Gurgaon
₹80,000
Yes
10 Sept 2022
27 Jul 2022
27 Aug 2022
27 Jul 2022
25 Aug 2022
11 Aug 2022
Amount
Supply and fixing in replacement of GI pipe, medium grade, ISI marked, 15 mm bore including all fittings and fixing arrangements all as specified and directed.
Supply and fixing in replacement GI pipe, medium grade, ISI marked, 20 mm bore including all fittings and fixing arrangements all as specified and directed.
Supply and fixing in replacement GI pipe, medium grade, ISI marked, 25 mm bore including all fittings and fixing arrangements all as specified and directed. Make -
Supply and fixing in replacement GI pipe, medium grade, ISI marked, 32 mm bore including all fittings and fixing arrangements all as specified and directed. Make -
Supply and fixing in replacement GI pipe, medium grade, ISI marked, 50 mm bore including all fittings and fixing arrangements all as specified and directed.
S&F in replacement gun-metal, globe or gate valves, with iron wheel head, screwed both ends to iron pipe and fixed to 20 mm bore pipe complete.
All as per srl item No 6 here-in-before but for size 25 mm bore. Make : Tata/Jindal/Zolotao
All as per srl item No 6 here-in-before but for size 32 mm bore. Make : Tata/Jindal/Zolotao
All as per srl item No 6 here-in-before but for size 50 mm bore. Make : Tata/Jindal/Zolotao
Supply and fixing in replacement of 20 mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement 25 mm Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engr-in-Charge.
Material & labour for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) for making rectangular cube of size 20X20X45cm for installation of solar collectors and support of hot water tank/ hot water pipes etc including frame work and demolition of old PCC blocks complete all as specified and directed.
M&L for demolition of cement Concrete in any description below or above ground level and removal from site complete all as specified and directed.
S&F providing Glass wool insulation 100mm thick insulated covered by cladding of aluminium sheet 24 SWG on warm GI water line of any size complete all as specified & as directed by Engr-in-charge.
Servicing of Solar Water Systems by pouring the anti-corrosion/anti scaling agent solution in the make up tank to clear the water circulated pipes of heat convertors sets upto ten solar panels of capacity 1000 LPD and drain out the solution by opening the nuts and bolts of dead plugs placed at the end of the system and make the system serviceable as per site requirement complete all as specified and directed by Engr-in-Charge.
Servicing of Solar Water Systems by pouring the anti-corrosion/anti scaling agent solution in the make up tank to clear the water circulated pipes of heat convertors sets upto five solar panels of capacity 500 LPD and drain out the solution by opening the nuts and bolts of dead plugs placed at the end of the system and make the system serviceable as per site requirement complete all as specified and directed by Engr-in-Charge.
Servicing of Solar Water Systems by pouring the anti-corrosion/anti scaling agent solution in the make up tank to clear the water circulated pipes of heat convertors sets upto three solar panels of capacity 300 LPD and drain out the solution by opening the nuts and bolts of dead plugs placed at the end of the system and make the system serviceable as per site requirement complete all as specified and directed by Engr-in-Charge.
Material & labour for MS framed work, fabricated from structural steel sections including welding, bending, cold or hot, drilling holes for bolts, in any shape or size and as indicated or directed having MS angle of size 40X40X4mm thickness on top for placing the collector panels/ water tank/supporting hot water pipes /ladders for approch etc inclusive of two coats of synthetic enamel paint over a coat of red oxide primer and fixing in walls/roof etc complete all as specified and directed by Engr-in-Charge.Note: Cost of taking down/dismantling is deemed to be included in quoted rates by contractor.
Material & labour for inspection and checking of fault in solar water heating system of 1000 LPD and rectify the fault including water supply pipe lines complete all as specefied and as directed by Engnr-in Charge. Note:- rectification of fault should be done on same working day
Material & labour for inspection and checking of fault in solar water heating system of 500 LPD and rectify the fault including water supply pipe lines complete all as specefied and as directed by Engnr-in Charge. Note:- rectification of fault should be done on same working day
Material & labour for inspection and checking of fault in solar water heating system of 300 LPD and rectify the fault including water supply pipe lines complete all as specefied and as directed by Engnr-in Charge. Note:- rectification of fault should be done on same working day
Material & labour for cleaning of solar panels toughned glass with detergent and after that with coline solution and make the glass completely clean including repairing of minor leakages complete all as specified. Note : (a) Cleaning of solar panel glasses should be done once in a month for entire systems which is installed at 13 BRD is consider as one job. (b) Labour /Cleaning material rates for the same shall be included in rate quoted by the contractor (Details of Solar water heater systems Airmen billet 1000 ltr capacity - 02 Nos, 500 ltr cap- 03 Nos, OMQ Map qtr - 500 ltr cap -03 Nos , SMQ Map qtr 300 ltr cap - 08 Nos)
Cleaning of 1000 ltr capacity PVC solar water tanks for with bleaching powder/non toxic solution throughly including removal of sand , clay silt, or any other material from inside the tank and making date of cleaning on tank complete all as directed.
Cleaning of 500 ltr capacity PVC solar water tanks for with bleaching powder/non toxic solution throughly including removal of sand , clay silt, or any other material from inside the tank and making date of cleaning on tank complete all as directed.
Cleaning of 300 ltr capacity PVC solar water tanks for with bleaching powder/non toxic solution throughly including removal of sand , clay silt, or any other material from inside the tank and making date of cleaning on tank complete all as directed.
Supply and fixing in replacement hose pipe clamps as per existing size up to 32 mm dia pipe complete all as specified and directed by Engr-in-Charge.
Supply & Fixing of Nut, M6 (Stainless steel) as per matching/ existing complete all as specified and directed by Engr-in-Charge.
Supply & Fixing of Bolt, M6 x 25, Hex Head (Stainless steel) as per matching/ existing complete all as specified and directed by Engr-in-Charge.
Supply & Fixing washers, M6 x 25, Hex Head (Stainless steel) as per matching/ existing complete all as specified and directed by Engr-in-Charge.
Supply & Fixing of Collector Screws (Stainless Steel.) as per matching/ existing complete all as specified and directed by Engr-in-Charge.
Supply & Fixing of Gasket as per matching/ existing complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement 25/32 mm dia hose pipe as per existing material size complete all as specified and directed by Engr-in-Charge.
M&L for rectification of leakage from GI 15 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 15 mm bore medium grade pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
M&L for rectification of leakage from GI 20 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 20 mm bore medium grade pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
M&L for rectification of leakage from GI 25 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 25 mm bore medium grade pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
M&L for rectification of leakage from GI 32/40 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 32 mm bore medium grade pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
M&L for rectification of leakage from GI 50 mm size bore pipe line by cutting and removing old lengh of pipe, supply & fix new galvanised iron pipe 50 mm bore medium grade pipe for stopping the leakage by making welding/replacemnt of necessary fittings of the same after drain out water from pipeline including insertion of pipe length upto 01 RM complete all as specifed and as directed by Engineer-in-charge.
M&L for descaling the heat collector panel (capacity 100 Ltr each) by descaling pump using commercial grade acid mixed with water in the ratio of 1:10 (acid : water) after opening / dismantling the heat collector panel from each other and re-fixing the same after complete cleaning including providing new nuts & bolts, gasket packing, worn out brass flange including brazing work , all other required hidden work for complete descaling complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement of old flat plate solar collectors toughned GLASS as per matching existing type , including all fixing accessories complete.
Supply and fixing in replacement of old flat plate solar collectors frame BOX, including all fixing accessories complete.
Supply and fixing in replacement of old flat plate solar collectors copper absorber, including all fixing accessories complete.
Supply and fixing in replacement of flat plate solar collectors of size 1992x1090x100 mm Complete puff insulated collector accessories complete as per matching/ existing. Make : ARINNA /Surya shakti India Pvt Ltd or equivalent ISI marked
S&F 5.8/6.0 Watt LED aviation light luminaires Integral comprising of aluminium alloy housing with polycarbonate enclosure, 60 Nos are used in 12 circuit parallel or equal capacity circuit suitable for high rise building complete all as specified. Make Bajaj /Surya or equivalent in Havells complete with lamp all as specified.
Supply, Installation, testing and commissioning in replacement of glass lined insulated hot water storage solar tank of stainless steel SS 304 of Capacity 1000 Ltrs duly insulated with glass wool, wire mesh, thermacoal including all inlet/ outlet connections etc on existing MS angle iron/ channel support for hot water tank complete all as specified and directed by Engr-in-Charge. Make: ARINNA /Surya shakti India Pvt Ltd or equivalent ISI marked. Note :- (a)The rate for taking down is deemed to fit in the quoted rate, no extra payment made on this account. (b) Any damage to the building while installing hot water storage tank should repaired in quoted amount, no extra payment made on this account.
Supply, Installation, testing and commissioning in replacement of glass lined insulated hot water storage solar tank of stainless steel SS 304 of Capacity 500 Ltrs duly insulated with glass wool, wire mesh, thermacoal including all inlet/ outlet connections etc on existing MS angle iron/ channel support for hot water tank complete all as specified and directed by Engr-in-Charge. Make: ARINNA /Surya shakti India Pvt Ltd or equivalent ISI marked. Note :- (a)The rate for taking down is deemed to fit in the quoted rate, no extra payment made on this account. (b) Any damage to the building while installing hot water storage tank should repaired in quoted amount, no extra payment made on this account.
Supply, Installation, testing and commissioning in replacement of glass lined insulated hot water storage solar tank of stainless steel SS 304 of Capacity 300 Ltrs duly insulated with glass wool, wire mesh, thermacoal including all inlet/ outlet connections etc on existing MS angle iron/ channel support for hot water tank complete all as specified and directed by Engr-in-Charge. Make: ARINNA /Surya shakti India Pvt Ltd or equivalent ISI marked. Note :- (a)The rate for taking down is deemed to fit in the quoted rate, no extra payment made on this account. (b) Any damage to the building while installing hot water storage tank should repaired in quoted amount, no extra payment made on this account.
Supply and Fix in replacement tripple layer Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 Ltrs hoisted and fixed in position complete all as specified and as directed By Engineer-in-charge.
Attending complaints related to electric geyser including replacement & minor repairs like element, thermostat, indicating lamps, hot water pipe and servicing of electric geyser by opening and and taking out slit deposited in the tank and over the element and obtaining completion of user on complaint slip, complete all as specified and as directed by engineer-in-charge. Contractor shall attend the complaints on requirement bases from 0900 to 1730 hours on working days including on non-working day also if required for that contractor shall deploy at least 01 semi skilled Electrician at Sekhon vihar residential complex (10 Blocks 10 storey bldg total 400 Officer Qtrs) for Day to day on all working day.The cost of said electricians and helpers shall be included in cost of attending complaints under this item and No extra payment on this accound shall be given to the contractor.
Supply only heat proof rubber pvc Gasket suitable for 25 Lrs geyser as per site requirement and complete all as specified & as directed by Engineer-in-charge.
Supply only heavy duty element holding assembly with provision of safety valve in its inlet pockets for thermostate, drain plug complete all as per site requirement and all as specified & directed by Engineer-in-charge.
Supply & fix in repair insulation of 25 Ltrs geyser as per existing insulating material in existing quantity for each geyser complete all as specified and as directed by Engineer-in charge.
Supply & Fix in replacement of fasteners up to 8 inch for fixing of geyser complete all as specified and as directed by Engineer- in Charge.
S&F in replacement of metal clad plug 20A 2P+E, 230V AC , complete all as specified and as directed by Engr-in-Charge. Make:- Indoasian/ anchor/ havells
Supply only 3 core flexible copper conductor of size 2.5 sqmm cable 1100V grade complete all as specified and as directed by Engineer- in Charge.
S&F in replacement of metal clad socket 20A 2P+E, 230V AC , complete all as specified and as directed by Engr-in-Charge. Make:- Indoasian/ anchor/ havells
Supply only brass ends wiremesh type stainless steel flexible hotwater connection pipe upto 2.0 feet as per requirement complete all as specified and as directed by engineer-in-charge.
Supply only auto cutoff system for geyser as per matching existing complete all as specified and as directed by Engineer- in Charge.
Supply only MTS thermostate for geyser as per matching existing complete all as specified and as directed by Engineer- in Charge.
Supply only MTS rectangle element 1.5/2.0 KW for geyser as per matching existing complete all as specified and as directed by Engineer- in Charge.
Supply only MTS round element 1.5/2.0 KW for geyser as per matching existing complete all as specified and as directed by Engineer- in Charge.
Supply only triangle type heating element 1.5/2.0 KW for geyser as per matching existing complete all as specified and as directed by Engineer- in Charge.
Supply only indicating lamps as per the site requirement complete all as specified and as directed by Engineer-in-charge.
Supply & Fix in replacement of glass lined inner tank suitable for 25 Lrs capacity geyser as per existing gauge and shape complete all as specified and as directed by Engineer-in charge.
Supply & Fix in replacement of outer body 18 gauge complete with bottom and top cover as per matching to existing type and size for upto 50 Ltrs capacity geyser complete all as specified and as directed by Engineer- in Charge..
Supply & Fix in replacement of top cover complete as per matching to existing type and size for upto 50 Ltrs capacity geyser complete all as specified and as directed by Engineer- in Charge.
Supply & Fix in replacement of bottom cover complete as per matching to existing type and size for upto 50 Ltrs capacity geyser complete all as specified and as directed by Engineer- in Charge.
Supply & Fix in replacement of outer ring GI steel of 18 gauge upto 3 inches height for holding of tank in geyser of capacity 25 to 50 Ltrs capacity complete all as specified and as directed by Engineer- in Charge.
Supply & Fix in replacement of apparture plate for geyser of capacity 25 to 50 Ltrs capacity as per matching to existing complete all as specified and as directed by Engineer- in Charge.
Supply & Fix in replacement of sleeve for protection of wire of geysers complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of MCB SP of rating, 20 Amps, 240 volt, 10 KA 'B' Series complete all as specified and as directed by Engineer- in Charge.
Supply & fix inreplacement of sheet metal enclosure for 220 volts 20 Amps with a three pin and earth plug top with socket and one single pole MCB 20 amps complete as well as specified and directed.
Disconnecting carefully water and electric connection from geysers and taking down of storage type water heater of capacity upto 50 ltr, 230 volt for cleaning and descaling of inner tank, heating plate assembly and element with suitable descaling solution properly including welding, soldering/brazing if required to arrest the minor leakage and re-assembling the complete geyser and refixing in existing position with fixing arrangement including necessary testings complate all as specified and directed.
Taking down unsv any type of submain wiring and M&L for concealed sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit pipe 25 mm dia medium grade and accessories of suitable size and fixed on concealed surface of wall/ceiling with cutting chases for conduit including one run of 4.0 Sqmm single core PVC insulated, FRLS , flexible multi stranded copper cable as earth continuity conductor in green color all as specified and as directed.Note- (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one unit.(b) Make disturbed surface good to wall/floors .
Taking down unsv any type of submain wiring and M&L for sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing-n-caping/conduit pipe as per site requirement medium grade and accessories of suitable size and fixed on wall/ceiling including one run of 4.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green color all as specified and as directed.
Supply only PVC conduit pipe of size of size 20 mm complete all as specified and as directed by Engineer- in Charge.
Supply and fixing threaded type PVC water tank cover suitable for 1000 ltr PVC tank complete all as specified and as directed by Engineer- in Charge.
Supply and fixing in replacement of 16 amp 3 pin plug complete all as specified and as directed by Engineer- in Charge. Make : Anchor/cone/Roma
Supply and fixing in replacement of 16 amp 3/5 pin Multi socket complete all as specified and as directed by Engineer- in Charge.. Make : Anchor/cone/Roma
Supply and fixing in replacement of 16 amp 3 pin Switch complete all as specified and as directed by Engineer- in Charge.. Make : Anchor/cone/Roma
S&F in replacement of indoor decorative LED batten light fitting 1x18/20W tube light fitting with 4 feet long LED Tube of 18/20W complete with all accessories internally prewired complete all as specified and directed by Engineer-in-Charge. Make:- Surya/ SYSKA/ PHILIPS/ HAVELLS
S&F in replacement of indoor decorative LED batten light fitting 1x9/10W tube light fitting with 2 feet long LED Tube of 9/10W complete with all accessories internally prewired complete all as specified and directed by Engineer-in-Charge. Make:- Surya/ SYSKA/ PHILIPS/ HAVELLS
S&F in replacement of wall Red & Green lamp fitting with bulb holder & LED Bulb complete with all accessories as per sample.
S&F in replacement of 2'X2' Surface /ceiling mounted light fitting 40/42W(10 % variation) LED including white diffuser complete with all connected accessories as per sample.
S&F in replacement of LED lamp of 9 /14 W 240Volts 50Hz complete all as specified and as directed by Engineer- in Charge.. Make:- Surya/ PHILIPS/ SYSKA
S&F in replacement of Lamp/ batten Holder for wall/surface mounted light fitting complete all as specified and as directed by Engineer- in Charge.
S&F in replacement of fancy type wall fitting with LED Bulb of 07W complete with all accessories as per sample complete all as specified and as directed by Engineer- in Charge.
S&F in replacement of Surface mounted round shaped 7 watt LED light fitting including white diffuser complete with all connected accessories as per sample complete all as specified and as directed by Engineer- in Charge.
Supply & fix in replacement of fluorescent tube light fitting flame proof FLP-WP of T5,1×28 W including integral reflector made of aluminium alloy LM6, with electronic ballest, bipin holders, connector blocks, etc and all accessories pre-wired and including connecting up with twincore twisted flxible copper condector with suitable size complete all as spceified and as directed by Engr-ni charge. Make:- Philips/Bajaj/Crompton or makes specified in list of makes.
Supply and fix in replacement of industrial wall mounted plug socket combined in polycarbonate enclosure suitable for IP44 degree of protection 16/20 Amps rating 2P+E, complete all as specified and as directed by Engineer- in Charge. Make- Neptune/schneider/Havells
S&F in replacement of LED driver 38/40 W 240 Volt 50Hz suitable for existing 2'×2' rectangular ceilling light complete all as specified and as directed by Engr-in charge. Make: Halonix/Syska/C&S/ or equivalent out of makes specified in list of makes.
S&F LED driver 15W 240 Volt 50Hz suitable for existing philips fancy rounded ceilling light Type: DN170C LED10S-6500 PSU WH complete all as specified and as directed by Engr-in charge. MAKE: Philips/Syska/C&S or equivalent out of makes specified in list of make.
S&F LED driver 21 W 240 Volt 50Hz suitable for existing Philips fancy rounded ceilling light Type: DN170C LED10S-6500 PSU WH complete all as specified and as directed by Engr-in charge. MAKE: Philips/Syska/C&S or equivalent out of makes specified in list of makes.
Notes:- (A) Note:-1. Since GI pipes, gate valves, solar tanks, collector panels and its connected items are located on the roofs and shaft of buildings of G+10 floors so cost of loading lifting has to bear by contractor and no extra payment shal be done this account. 2. while repairing / replacing gi pipes, gate valves and its connected items in the shaft contractor shall provide safety harness to the labour and its cost is deemed to be fit in qouted rates. 3. Any damages done while loading/lifting, mounting/dismounting of various items from/to the roof shall be bear by contractor only.
Notes:- (a) The amount of Rs 134440/- against Schedule of Credit shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance. (b) The contractor shall provide and deploy sufficient mechanic with helpers (as approved by GE / Engr-in-charge) for maintenance of summer appliances and contractor's site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints & complete the same complaint detailed by JE E/M /Engineer-in-charge with in 12/24 hrs. (c) The complaints shall be rectified with in 12 hrs. (except repair/ replacement of major items like repair/ replacement of geyser, geyser inner tank repair work. These work can be completed within 48 Hrs), If the complaints is/are not done within the time frame as specified above the panelty of Rs 100.00 per complaint per day shall be charge from the contractor. (d) The decision of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained. (e) The Mechanics for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at AF Station PALAM. (f) The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge. (g) Any material required to be replaced for complaint rectification other than specified shall be measured and paid seperately under respective supply only items. (h) The contractor shall provide all the stationery required at complaint cell at 13 BRD complete all as specified and as directed by Engineer-in-charge. (j) supply only items shall be available in store and shall be issued as per the requirement . (k ) Any minor spares like insulation tape, gitti including tools for trade men etc shall provided by the contractor at own cost.
M/S Anand Enterprises
SM CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .