| 4 | Rejected-Technical | - | Rejected-Technical Not enlisted in particular category | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in particular category |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
28 Mar 2022, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
REPAIR/MAINTENANCE AND SERVICING OF DG SETS, LIFTS AND LIGHTENING PROTECTION SYSTEM AND CERTAIN ESSENTIAL MAINTENANCE OF CRANES INSTALLED AT DRDL, ASL, NGARM, QRSAM AND SFDR AREA UNDER GE (I) RND KANCHANBAGH, HYDERABAD
2022_MES_511232_1
GE I KBAGH TOKEN 81 OF 2021 2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹98,000
Yes
6 May 2022
1 Mar 2022
30 Mar 2022
1 Mar 2022
28 Mar 2022
15 Mar 2022
2 Mar 2022 - 10 Mar 2022
Amount
Opening / taking out of fuel injection pump of DG set of any type/make and capacity 30 KVA to 40 KVA disconnection of fuel injector line, carrying complete overhauling/ servicing of injector pump, ,calibration of fuel pump as per manufacturer instruction , assembling the same with DG set properly in original position, checking the alignment , making proper fuel connection and testing for smooth operation complete all as directed, after replacement of following items. Note:-Following items measured & paid separately.
Fuel gear pump.
Shaft fuel pump drive .
Shaft fuel pump
Seal 'O' Ring.
Gasket fuel pump
Gear techno meter
Bushing techno meter.
Cover fuel pump gear
Housing fuel pump gear
All as serial No-1 here in before but of capacity 100 to 200 KVA.
Fuel gear pump
Shaft fuel pump drive
Shaft fuel pump
Seal 'O' Ring.
Gasket fuel pump
Gear techno meter
Bushing techno meter.
Cover fuel pump gear
Housing fuel pump gear
All as serial No-1 here in before but of capacity 250 KVA to 320 KVA .
Fuel gear pump.
Shaft fuel pump drive
Shaft fuel pump
Seal 'O' Ring.
Gasket fuel pump
Gear techno meter
Bushing techno meter.
Cover fuel pump gear
Housing fuel pump gear
All as serial No-1 here in before but of capacity 500 KVA to 750 KVA .
Fuel gear pump.
Shaft fuel pump drive
Shaft fuel pump.
Seal 'O' Ring.
Gasket fuel pump
Gear techno meter
Bushing techno meter.
Cover fuel pump gear
Housing fuel pump gear
Removal of self starter motor from the DG set of capacity 30 KVA to 40 KVA of existing make , strip opening the starter for the following repair/ replacement including assembling and re-fixing at site.
Armature.
Solenoid switch
Bush gear
'O' Ring assy.
Bush set.
FIELD Coil
Sealing kit.
Brush Set
All as serial No-5 here in before but of capacity 100 KVA to 200 KVA .
Armature.
Solenoid switch
Bush gear
'O' Ring assy.
Bush set.
FIELD Coil
Sealing kit.
Brush Set
All as serial No-5 here in before but of capacity 250 KVA to 320 KVA.
Armature.
Solenoid switch
Bush gear
'O' Ring assy.
Bush set.
FIELD Coil
Sealing kit.
Brush Set
All as serial No-5 here in before but of capacity 500 KVA to 750 KVA.
Armature.
Solenoid switch
Bush gear
'O' Ring assy.
Bush set.
FIELD Coil
Sealing kit.
Brush Set
Removal & replacement old unserviceable feed pump for fuel injection pump complete assay for various capacity of DG set.
Supply & fixing in replacement, of fuel shutoff valve assay , solenoid valve kit including taking outsold valve assay and making all connection, testing for smooth operation complete all as directed.
S&F in repairs element Air cleaner, inner for DG set 30 KVA to 40 KVA.
S&F in repairs element Air cleaner, inner for DG set 110 KVA to 200 KVA.
S&F in repairs Element Air cleaner, inner for DGset 110 KVA to 200 KVA .
S&F in repairs element Air cleaner, inner for DG set 250 KVA to 320 KVA.
Material & labour for opening / taking out of injector of DG set of any type/make and capacity 30 KVA to 200 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/ servicing fuel injection system with including replacement of injector repair kit, including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the alignment, making proper fuel connection, testing for smooth operation complete all as directed.
Material & labour for opening / taking out of injector of DG set of any type/make and capacity 320 KVA to 500 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/ servicing fuel injection system with including replacement of injector repair kit, including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the alignment, making proper fuel connection, testing for smooth operation complete all as directed.
S&F in replacement of Old unserviceable lifting magnet of existing make suitable for 30 KVA to 500 KVA DG set
Supply and fixing, in replacement, Radiator cap suitable for DG Set of any type / make and capacity, complete all as directed.
Dismantling and taking down of old unserviceable LT panel board of any capacity/size by disconnecting all electrical and mechanical connections of panel board and old unserviceable panel board shall be deposited to AGE E/M store yard and removing all materials to make the good surface/wall/ installations all as specified and directed.
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 440 Volts indoor type cubical compartmentalized vermin and water proof fabricated by CPRI approved out of 2.0 mm thick CRCA sheet powder coated and including 600 amps rated Aluminimum bus bar, insulated with PVC sleaves and coloured with (red, yellow,blue and black), CTs, metering equipment, indicating lamps and internal wiring with suitable size of PVC insulated copper wire, with angle iron 45x45x6 mm frame bottom of the panel board , grouted by using PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate , thumbing and cable entry boxes with cable gland including painting with two coat of powder coated painting over a coat of red oxide primer complete with including the followings :- (a) MCCB 400 Amps, 4 Pole, 36 KA thermal magnetic adjustable S/C & E/F protections along with rotary handle - 01No. (incoming) (b) MCCB 200 Amps, 4 pole, 36KA, thermal magnetic adjustable S/C & E/F protections along with rotary handle - 02Nos. (outgoing) (c) MCB TPN 63 Amps, 4 pole, 10KA, 'C' curve-04 Nos (outgoing)
S&F in replacement of unserviceable thermostat with new thermostat along with complete assay for DG set connection testing complete all as specified and directed.
Removal & replacement of Old unserviceable RPM CABLE.
Removal & replacement of Old unserviceable water temp meter .
Removal & replacement of Old unserviceable OIL PRESSURE METER .
Removal & replacement of Old unserviceable OIL TEMP METER .
Removal & replacement of Old unserviceable H.C.T. SWITCH .
Removal & replacement of Old unserviceable LLOP SWITCH .
Supply & fixing in replacement of anti vibration mounting pad 'B' series complete all as directed.
Material & labour for CTs of ratio 100/5,150/5, 200/5 & 300/5
Material & labour for CTs of Ratio 400/5, 500/5. Make for item No.29 & 30: KAPPA/ C&S
Material & labour for Supply & fiXing in replacement of push button suitable for emergency stop button.
S&F in replacement Digital volt meter ,3 phase(0-500) volt of size 96mm x 96 mm complete.
S&F in replacement for Digital Ammeter, 3 phase, 0-600Amps. Make for item No.32 & 33:- L&T/HPL/SIECO
Supply & fixing in replacement of Electric Control Unit duly programmed, fixed in control panel with and including checking, rewiring faulty circuit ,suitable for DG set of any type up to 500 KVA .
Material & labour for opening /taking out of turbo charger of DG set of 30 KVA to 250 KVA capacity ,disconnection of air supply connection pipe etc,complete overhauling, servicing of turbo charger ,replacement of turbo charger repair kit including calibration/ testing of turbo charger system complete and re-assembling the same ,fitted with DG set properly in original position, checking the alignment, making proper all connection, testing for smooth operation complete all as directed.
All as serial No-35 here in before but DG set of 320 KVA to 500 KVA capacity.
Dismantling of engine 320 to 500 KVA DG set of any make and taking out radiator assay, self starter, silencer, air cleaner, fuel injection pump, injector assay, water body, turbo charger, hose pipe set, cylinder head, tappet cover, engine block, piston ring, sleeve connecting rod, bearing and all minor parts such as nuts, bolts etc, cleaning/ segregating of serviceable, unserviceable parts, cleaning of silencer, removing of cylinder liner, boring of engine block, pressure testing of engine and cylinder head, grinding and polishing of valve system, cutting of valve, seat and setting of exhaust pad intake valve and renewal of worn out parts of engine including resembling of complete engine, testing on load.
Supply & fixing following spare parts for DG sets of capacity 320 to 500 KVA of existing make complete all as specified and as directed.
CYLINDER LINER Cat part no. BM 98224
LINER O RING Cat part no. 216879
PISTON Cat part no. 200710
PISTON RING SET Cat part no. KITAR12098
C R BEARING Cat part no. 203670
HEAD VALVE EXHAUST Cat part no. 144911
HEAD VALVE INLET Cat part no. 150288
VALVE SEAT EXHAUST Cat part no. 69965
VALVE GUIDE Cat part no. 66890
SUMP GASKET Cat part no. 21710
TAPET SCREW & NUT Cat part no. 168306
HEAD GASKET Cat part no. KITBM50745
Dismantling of engine 110 to 250 KVA DG set of any make and taking out radiator assay, self starter, silencer, air cleaner, fuel injection pump, injector assay, water body, turbo charger, hose pipe set, cylinder head, tappet cover, engine block, piston ring, sleeve connecting rod, bearing and all minor parts such as nuts, bolts etc, cleaning/ segregating of serviceable, unserviceable parts, cleaning of silencer, removing of cylinder liner, boring of engine block, pressure testing of engine and cylinder head, grinding and polishing of valve system, cutting of valve, seat and setting of exhaust pad intake valve and renewal of worn out parts of engine including resembling of complete engine, testing on load.
Supply & fixing following spare parts for DG sets of capacity 110 to 250 KVA of any make.
CYLINDER LINER Cat part no. BM 98224
LINER O RING Cat part no. 216879
PISTON Cat part no. 200710
PISTON RING SET Cat part no. KITAR12098
C R BEARING Cat part no. 203670
HEAD VALVE EXHAUST Cat part no. 144911
HEAD VALVE INLET Cat part no. 150288
VALVE SEAT EXHAUST Cat part no. 69965
VALVE GUIDE Cat part no. 66890
SUMP GASKET Cat part no. 21710
TAPET SCREW & NUT Cat part no. 168306
HEAD GASKET Cat part no. KITBM50745
Material and labour for servicing/repair of AMF panel of DG set up to 500 KVA capacity for smooth functioning of the same with renewal / repairs of AMF panel wiring, control timer, engine starting relay, contact point relay, AMF relay, HRC fuse of existing rating etc complete for DG sets installed, all as specified and directed. Note:- 1. The rates quoted by the contractor shall deemed to include the cost of spares/relays or any other part not mentioned herein but essentially required to make the AMF Panel completely functional and no extra payments shall be made for the same.
Supply and fix in repairs electronic control timer type ET-100 of suitable capacity as required at site. Make:- L&T or equivalent as approved by GE
Supply and fix in repairs engine starter relay of suitable capacity as required at site. Make:- L&T or equivalent as approved by GE
Supply and fix in repairs under voltage relay Make:- PIC / EC / Wader.
Supply and fix in repairs 8/11 pin relay Make:- PLA.
Supply and fix in repairs Auto Mains Failure (AMF) relay as per existing model and make of AMF panels of DG sets of any capacity.
Supply and fixing crocodile clip for battery chargers of required size all as specified and directed.
Supplying, fixing, connecting & testing battery, 12 volts, 180 AH with lead acid terminals, indication of charging position and terminals for connection etc including initial charging of Battery complete all as specified including disconnecting existing unserviceable battery.
Supplying, fixing, connecting & testing battery, 12 volts, 150 AH with lead acid terminals, indication of charging position and terminals for connection etc including initial charging of Battery complete all as specified including disconnecting existing unserviceable battery.
Supplying, fixing, connecting & testing battery, 12 volts, 100 AH with lead acid terminals, indication of charging position and terminals for connection etc including initial charging of Battery complete all as specified including disconnecting existing unserviceable battery.
Material and labour for dismantling the alternator above 30 KVA but up to 110 KVA capacity from the DG sets from coupling and opening the stator & rotor including cleaning of dust from windings for proper ventilation, renewal of carbon brushes with brush holder and assembling the rotor & stator complete including applying suitable greasing & oiling of bearing & moving parts complete all as specified and directed.
Material and labour for dismantling the alternator above 160 KVA but up to 200 KVA capacity from the DG sets from coupling and opening the stator & rotor including cleaning of dust from windings for proper ventilation, renewal of carbon brushes with brush holder and assembling the rotor & stator complete including applying suitable greasing & oiling of bearing & moving parts complete all as specified and directed.
Material and labour for dismantling the alternator above 250 KVA but up to 500KVA capacity from the DG sets from coupling and opening the stator & rotor including cleaning of dust from windings for proper ventilation, renewal of carbon brushes with brush holder and assembling the rotor & stator complete including applying suitable greasing & oiling of bearing & moving parts complete all as specified and directed.
Supply and fixing in repairs "ON LOAD" type change over switch front handle operated, on existing LT/AMF panels, of capacity1000 Amps and suitable for three phase, 415 V, 50Hz AC as per existing make suitable to be fitted with the existing panels or any other make as mentioned in CA including taking down old one and making all connection including renewal of cable lugs/terminals if required complete all as specified and directed.
All as per item No. 54 above but of capacity 630 Amps
All as per item No. 54 above but of capacity 320 Amps
Supplying and fixing in replacement, testing off load changeover of capacity 200 Amps, 415 Volts, four pole with sheet metal enclosure ,side handle operated, 50 Hz, fixed to walls/ panels with suitable size clamps, nuts, bolts and washers including grouting of screw, bolts and fasteners on wall with PCC and making connections and testing complete all as specified and directed.
All as per item No. 57 above but of capacity 320 Amps.
All as per item No. 57 above but of capacity 800 Amps
Supply and fix in repairs battery charger heavy duty type with voltmeter and ammeter, with copper wound transformer and provision for auto cut for protection against overcharging and suitable for charging 02 Nos 12 Volts 180 AH battery complete all as specified and directed.
Supply and fix in repairs power contactor assembly of capacity 125Amps, 3/4 Pole, AC 415 Volts, 50 Hz for AMF panel boards as per existing model including taking down old one complete all as specified and directed.
Supply and fix in repairs power contactor assembly of capacity 200Amps, 3/4 Pole, AC 415 Volts, 50 Hz for AMF panel boards as per existing model including taking down old one complete all as specified and directed.
Supply and fix in repairs power contactor assembly of capacity 400 AMPS, 3 Pole, AC 415 Volts, 50 Hz for AMF panel boards including taking down old one complete all as specified and directed.
Repair to radiator of 250/200 KVA DG set by soldering of copper pipes rectifying leaks, cleaning and PVC hose fitting complete and fixing back after repair.
Repair to radiator of 320/300 KVA DG set by soldering of copper pipes rectifying leaks, cleaning and PVC hose fitting complete and fixing back after repair.
Preparation of old painted surfaces of the DG sets of the 63 KVA DG Set capacity complete degreasing and spray painting the same with one coat of synthetic enamel paint including writing SM/MES No complete all as specified and directed.
All as per item No. 66 above but for capacity 180 KVA
All as per item No. 66 above but for capacity 200 KVA
All as per item No. 66 above but for capacity 250 KVA
All as per item No. 66 above but for capacity 320 KVA
All as per item No. 66 above but for capacity 500 KVA
Supply & Fix in replacement of electronic governor of Cap 30-40 KVA DG set complete all as directed.
All as per item No. 72 above but of capacity 110 - 200 KVA
All as per item No. 72 above but of capacity 250 - 320 KVA
All as per item No. 72 above but of capacity 500 - 750 KVA
Supply and fixing in replacement of radiator unit including bottom tray for the DG sets as per existing make and model for 110/160/180 KVA DG sets including initial topping up of coolant and all accessories complete all as directed.
Supply and fixing, in replacement, Radiator hose pipe with clamps suitable for 110 KVA to 320 KVA DG Set of any type / make and capacity, complete all as directed.
Supply & Fix in replacement of fuel pump 3 feet long of DG set complete all as directed.
Supply and fixing, in replacement, water manifold hose pipe with clamps suitable for 110 KVA to 320 KVA DG Set of any type / make and capacity, complete all as directed.
Supply & Fix in replacement of Fan belt as per existing capacity and size complete all as directed.
Supply & Fix in replacement of taped gasket as per existing capacity and size complete all as directed.
Taking down the old unserviceable water pump from Engine of DG set of any capacity and taking it out side work shop, calibration of water pump, completely overhauling the water pump including replacing of gaskets, nuts, washers etc, reassembling the same and refixing the pump to the engine, testing complete all as directed.
Taking down the defective turbo charger assembly duly disconnecting the mechanical connections from DG set, opening and thoroughly checking to carry out repairs complete to the turbo charger assembly and replacing the turbo charger kit and spares as required at site including any machining and reassembling and refixing the turbo charger assembly in its original position and reconnecting the same for the following capacity DG set including testing complete all as directed.
110 to 160 KVA DG set
180 to 200 KVA DG set
250 to 320 KVA DG set
M&L for earthing complete with galvanized steel, earth plate electrode 600x600mm x 6mm thick buried directly in ground vertically (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanized iron 32 x 6 mm strip as earth lead by means of bolts, nuts, check nuts and washers of galvanized iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 40mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed.
S&F in repairs GI earth strip of 32x6 mm dia fixed on walls/floor as earth continuity conductor fixed on wall/roof on epoxy insulators etc complete all as specified and directed.
All as per item No. 85 above but aluminium strip of size 25x3mm fixed on wall/roof on epoxy insulators complete all as specified and directed.
S&F in repairs test point consisting of terminal box, drilled and screwed with 22 swg GI cover including 2 Nos 12mm dia 25mm long hexagonal head screws jointing GI and aluminium strips with bolts, nuts and washers on and including jointing plate made of gun metal or phosphor bronze of size 90x32x8mm complete enclosure/terminal block assay grouted in wall at 600 mm height from the length protection level by means of two nos 40x40x5mm MS plate with 6mm dia anchored bolts embedded in wall including nuts and washers all as specified and directed and shown on drawings
Supply and fix in repairs single pointed air termination aluminium rod 12mm dia 600mm long and including 40mm dia GI Medium grade support pipe 600mm long, 25x6mm MS flat iron clamps, bolts/nuts and washers etc lower end of pipe fitted in a 40mm dia GI socket screwed and welded on and including MS base plate of size 300x300x6mm thick grouted on top surface of the wall with 4 Nos 12mm dia regged MS bolts/nuts washer etc on GI pipe secured firmly laterally on the wall surface in a vertical manner by means of rugged bolts grouted on the walls including nuts and washers etc upper end of pipe duly plugged lower end of Air termination rod duly jointed/welded with down/ horizontal conductor complete all as specified and directed and shown on drg..
Supply and lay in repairs GI tubing light grade of size 40 mm dia for protection of GI strip to be laid in trenches/walls and complete all as specified and directed.
Periodical maintenance for the following capacities lifts at various bldgs:- Note : (a) Cost of the comprehensive maintenance incudes all minor consumable repairs/replacement of spares/parts like grease, lubricant oil, cotton waste thimbles, small pieces of cables, cable lugs, bolts, nuts, washers, emery papers and like sundry items and supply and fix all types of minor spare parts shall be deemed ot be included in the quoted in unit rate. (b) The comprehensive maintenance to be carried out by Original Equipment manufacturer (OEM) or any authorised service partner only. (c) All break down and repair shall be attended by OEM as and when fault / trouble accurs in the lift and the complaints should be addressed within 04 hours and minimum 01 inspection shall be carried out by the OEM monthly. All safety tests should be carried out by OEM and report to be submitted to the Engr-in-Charge. (d) The replacement of spares/parts measured and paid separately.
Astra Bldg lift of capacity 1.0 Ton. Make : Omega Elevators.
All as per item No. 90 here-in-before but of capacity 0.5 Ton at Knowledge Centre lift. Make : Supriya Elevators.
Repair/Maintenance of EOT crane/EOT flame proof cranes and HOT cranes of any type like Wheels, Girder, Wire rope, Hook block, Hook, Bumper, Walkway, Trolley, Hoist, Hoisting motor, Hoisting gear, ropedrum, loadbeam, buffer, LT & CT etc., identifying and replacing the defective components like power contactor, push button/switches, flexible geared coupling, bimetal over load relay, thruster break oil, steel wire rope, copper conductor PVC cale of suitable size, main hoist steel wire rope gear box mechanism/spares, HRC fuses and etc,. Cranes of any make and model of various spans for the following capacities all as directed by Engr-in-charge. Note : (i) The rate against the above mentioned items is deemed for cost of labour only. (ii) Cost of spares like contactor, push button/switches, flexible geared coupling, bimetal over load relay thruster break oil, steel wire rope, copper conductor PVC cale of suitable size, main hoist steel wire rope gear box mechanism/spares, HRC fuses replaced against above mentioned item will be measured & paid for separetely under respective items of Sch 'A' here-in-below.
01 Ton to 30 Ton capacity
Periodical examination, normal and routine maintenance including cleaning/greasing & oiling of all wherever applicable parts like Wheels, Girder, Wire rope, Hook block, Hook, Bumper, Walkway, Trolley, Hoist, Hoisting motor, Hoisting gear, ropedrum, loadbeam, buffer, LT & CT etc., corrective maintenance of trouble free working of all electrical connections in panels/wiring/contactor/drive/fuse link/MCB, Terminal, Bus bars testing and functioning of all parameters like CT/LT and Hoisting checking and functioning of gear box, push buttons/station limit switches on both of CT & LT, radio remote control switches also included topup gear oil/lubrication system & greasing of all ratating parts wherever applicable, repair and replacement of spares in place of old unserviceable items of EOT cranes/EOT flame proof cranes of any model of various spares for the following capacities and all as specified and directed. Note : (i) Spares required to maintain the cranes will be measured and paid separately as supply only under relevant item. (ii) Labour element required for spares are deemed to be included in rate quoted. Note: EOT crane inspection to be carried out by authorised crane Technician of OEM, once every month. (iii) EOT crane inspection to be carried out by authorised crane technician of OEM once every month and submitted to Engr-in-charge without fail.
30 Ton capacity - 02 Nos
10 ton capacity - 05 Nos
10 ton capacity flame proof - 02 Nos
5 ton capacity - 10 Nos
5 ton capacity flame proof - 04 Nos
3 Ton capacity - 06 Nos
01 Ton & 02 Ton capacity - 08 Nos
Periodical examination, normal and routine maintenance including cleaning of all parts and carrying out corrective maintenance for trouble free working by using greasing, oiling of all wherever applicable parts are included in quoted reates, repairs and replacement of spares in place of old unserviceable items of HOT cranes of any make and model of various spans for the following capacities complete all as directed. Note : (i) Spares required to maintain the cranes will be measured and paid separately as supply only under relevant item. (ii) Labour element required for spares are deemed to be included in rate quoted. Note: HOT crane inspection to be carried out by authorised crane Technician of OEM once every month.
5 ton capacity - 01 No
3 Ton capacity - 06 Nos
01 Ton & 02 Ton capacity-02 Nos
Material and labour for conducting the load and deflection test to EOT/HOT cranes by the lift inspector operated by the state Govt. for following capacities and submitting test report to the GE through Engineer-in-charge. Note (i): Load blocks for testing of cranes shall be provided by the contractor under his own arrangement including transportation to and from the site and the cost for the same is deemed to be included in quoted rate. (ii) The load carrying slings should be tested prior to load test and the test certificate with all parameters should be signed by the safety officer & Engineer-in-Charge.
30 Ton capacity
10 Ton capacity
05 Ton capacity
03 Ton capacity
02 Ton capacity
01 Ton capacity
Supply only Gear Oil of suitable for crane gear assembly. Make:- Servo/Castrol or equivalent.
Supply only Power Contactor 32 to 40 Amps ACI type with 110 Volt coil voltage, three phase.
Supply only Power Contactor 40 to 70 Amps ACI type with 110 Volt coil voltage, three phase.
Supply only spare kit for 32 to 40 Amps ACI contactor of any type
Supply only spare kit for 40 to 70 Amps ACI contactor of any type Make for srl item 96 to 99 : L&T/BCH/C&S/Telemech
Supply only push button of any type, Make : L&T/GE.
Supply only Flexible geared coupling of any type/size
Supply only Bimetal over load relays for contactors Make for srl item No. 101 & 102 : BCH/L&T/C&S/Telemech.
Supply and fix in repairs VFD drive of crane upto 5 ton capacity drie should be suitable for the existing crane incluidng removing the unserviceable VFD drive complete all as directed.
All as per item No. 103 here-in-before but for 5 to 10 Ton capacity crane
Supply and fix in repairs VFD drive control card of crane upto 5 ton capacity drive control card should be suitable for the existing crane incluidng removing the unserviceable VFD drive control card complete all as directed.
All as per item No. 105 here-in-before but for 5 to 10 Ton capacity crane
Supply & fix HRC fuse 16A with fuse carrier complete including removing the unserviceable HRC fuse complete all as directed. Make : GE/L&T/BCH.
Supply & fix HRC fuse 32A with fuse carrier complete including removing the unserviceable HRC fuse complete all as directed Make : GE/L&T/BCH.
Universal refrigeration and Engineering Company
ELEVATORS MAINTENANCE ENGINEER WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .