| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.3 CrAccepted-AOC BLOCK N 259 GROUND FLOOR BLOCK N MAYFIELD GARDEN SECTOR GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | ₹1.3 Cr Quoted ₹1.4 Cr | 1 | Accepted-AOC 1 |
| 2 | 2₹1.4 Cr+₹38,995.65 (0.29%)Rejected-AOC 491 28 4TH FLOOR TOWNE CENTRE MALL BEHIND D PARK MODEL TOWN NEAR POLICE CHOWKI ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹1.4 Cr+₹38,995.65 (0.29%) | 2 | Rejected-AOC 2 |
| 3 | Not Admitted-Fee/PreQual/Technical 1804 SECTOR 2 HUDA 124001 | ROHTAK | HARYANA | 124001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
25 May 2023, 12:00 pmClosed
Vishal Garg
Municipal Corporation Gurgaon
Interior Fit Out work of Corporate Office at MCG Building, surrounding area, Sector 34, Gurugram.
2023_HRY_280860_1
2023B99302BA 48E2 4748 B916 5304DE1A2598285ULB
Open Tender
Civil Works
Works
180 days
Gurugram
2 documents required · 2 mandatory
₹15,000
₹2.2 L
Yes
20 Sept 2023
10 May 2023
25 May 2023
10 May 2023
25 May 2023
10 May 2023
Amount
False flooring - 150-300mm ht - 600x600mm The access floor system to be installed to provide a finished floor height of 300mm from the existing floor level. The system shall include suitable understructure assembly to withstand various static loads and rolling loads as mentioned below. The entire Access floor system shall be made from steel understructure and steel panels with cementatious infill. Raised access floor system shall be tested for fire resistance [Min 120mins], acoustic barrier [Min 50 NNIC] and air leakage resistance with low airleakage rates. Floor panels shall be epoxy coated unitized shells consisting of flat steel top sheet welded to a formed steel bottom sheet filled with controlled mixture of lightweight cement. Floor panels and understructure system to be designed to cater below mentioned criteria Uniformly distributed load of 1080 Kg/sqm with capability to carry a uniform load of 200Kg on one square feet area at any location of the panel with maximum top surface deflection of 1.5mm. Permanent deformation of the panel should not exceed 0.25 after removal of load. Concentrated load of 360 Kgs placed on one square inch area using a round or square indentor at any location on the panel. Maximum top surface deflection not to exceed 2.54mm and permanent deformation not to exceed 0.25mm after removal of load. The panel shall be capable of withstanding the same concentrated load with maximum panel cutout of size 200mm dia. Panel shall be capable of being dropped face on onto a concrete slab from a height of 900mm after which it shall continue to meet all load performance. The access floor system shall be designed with a minimum safety factor of 2
Providing and applying plaster of paris on walls in line and level of maximum 12 mm thickness over plastered surface to prepare the surface even and smooth complete. The rate shall include scrapping, leveling and preparing the surface. The rate shall be inclusive of all types of grooves above the skirting, around the window and door
Providing and fixing 50 mm high Anodised/Powder coated Aluminium Skirting Designed to be installed on wall, gypsum and plywood partitions and on top of all kinds of flooring Installed using screws, to camouflage the rivet points. a capping strip is provided either in PVC of matching color or aluminium. Supplied with pre-drilled holes and protection tape which is removed after completion, Matching corner guards are provided with the profiles.
Providing and fixing of modular trap doors as per architects approval. Make: Knauf Trap Doors - 600X600mm
Providing and fixing single layer gypsum paneling as per standard manufacturer specifications.with GI frame and rockwool insulation
Providing and Fixing 1mm thick laminate as/approved sample laminate over MDF/ Ply, joints should be staggered such that they do not overlap joints of MDF
Supply and installation of stud partition using C-stud. 48x0.5mm C-stud (IS 15961) placed at 610mm c/c in 50x0.5mm (IS 15961) floor and ceiling channel . Floor and Ceiling channel is anchored to the floor and True ceiling using Rawl plug Ø8x45mm {Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-6.8kN for M30 concrete grade} /Hilti Nail anchor fasteners at 600mm c/c in center line manner. Floor channel to be wrapped with 70µ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. A noggin channel {Material-IS 513,Y/S-300Mpa, Finish - AZ150 (IS 15961)} of 48x0.5mm width has to be provided at the horizontal joints of the two boards. The frameowrk to be packed with 50mm th. 48kg/Cum. density Rockwool insulation infill to be covered with RP Tissue placed in metal framework. Framing to be wrapped with Double layer of 12.5mm thick Standard Gypsum plasterboards (Confirming to IS 2095: Part 1) is screw fixed vertically to either side of wall Studs with 25mm long Drywall Screws at 300mm centers. The screw fixing of Gypsum plasterboards to the metal framing at the periphery, openings and cut edges should be at 150mm centers. The horizontal and vertical joints of the Gypsum plasterboards on both sides of the metal framework must be staggered so as to avoid through and through joints. All joints to be taped and finished with 50mm wide Paper tape and All Purpose Joint compound. (Confirming to ASTM C475). The junction of the partition with masonry and all penetration through the partition has to be treated with Hilti/Pyroplex fire and acoustic sealant. All other detailing and specifications to be followed as per manufacturer specifications
SINGLE GLAZED TOUGHENED GLASS PARTITIONS-with SYSTEM-50 FRAME PROFILES: Supply and installation of Aluminium Framed Glass Partition for Access and Cabin System for minimal frame, room dividing solutions. Single glazed mullion free demountable glass partition using Toughened/ Laminated glass in proprietary natural anodised/Black aluminium sections ALT 50 of size 50mm x 30mm with Concealed sealing (No visible Gaskets/Seals) with acoustic rating of Minimum 32 db with third party test certificate. The profile will have Carpert Groove at the Bottom on both sides for accomodating max. 8mm carpets. THe Glass to be fixed with help of Proprietary Stability GRIPPER Clamp to have a stable system. It should consists of intermediate slim junction profiles for Glass to Glass vertical joints, 90 Degree L Junction and T Junction profiles suitably to be used as per room configuration designs.No VISIBLE Clip Lines to provide clutter free view at both side of section. The Glass to be Offset mounted towards outer edge leading to minimum aluminium frame on one side. Optional Profile Bottom Seal pair for additional accoustic. Glass thickness - 10( LSG).shall be included in the product.
Providing and fixing toughened glass door of size 750X2400 fitted with all necessary SS hardware like door handle, patch fittings and floor spring.
Providing an fixing 45 x 45 mm Aluminum proprietry Sections with necessary ply Backing and framing behind Al. sections. Al. Sections to have 12 mm th. Ply/mdf along wall edges, as grooves.
Supply, Installation, Testing and Commisioning appropriate driver for LED strip roll for Kove light
Supply, Installation, Testing and Commisioning of Pendant downlight with HPE (HighPerformance Efficiency), system power: 35 W, Luminous flux of luminaire 1200 lm, Colour temperature of 4000 K, Neutral white, CRI ) 80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours: energy-efficient LEDs, direct light emission, Polyester powder black coloured coat applied over a 5-stage pretreatment, Opal diffuser for homogenous light distribution, electronic control gear, Adjustable wire suspension,Protection class II, IP 20,Ø = 177.5 mm, H = 107 mm, Special Lighting
Supply, Installation, Testing and Commisioning of ceiling recessed grid light with HPE (High-Performance Efficiency), system power: 36W, Luminous flux of luminaire 1200 lm, Colour temperature of 4000 K, Neutral white, CRI ) 80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours: energy- efficient LEDs, direct light emission, Polyester powder black coloured coat Applied over a 5-stage pretreatment, Opal diffuser for homogenous light distribution, electronic control gear, Adjustable wire suspension,Protection class II, IP 20,Ø = 160 mm, H = 43 mm. Light size 600X600 mm. make: Phlips or similar
Supply, Installation, Testing and Commisioning of cell Ceiling mounted downlight with HPE (High-Performance Efficiency), system power: 25 W, uminous flux of luminaire 1200 lm, Box type poweder coated to fit in open cell ceilingColour temperature of 4000 K, Neutral white, CRI ) 80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours: energy- efficient LEDs, direct light emission, Polyester powder black coloured coat applied over a 5-stage pre-treatment, Opal diffuser for homogenous light distribution, electronic control gear, Adjustable wire suspension, Make Philips or similar
Supply, Installation, Testing and Commisioning of Bracket light haloge type with HPE (High-Performance Efficiency), system power: 25 W, uminous flux of luminaire 1200 lm, Make Philips or similar
Providing Philips LED 4` batten light..
SITC of 86` diplsay panel with IPS technology, 16:9 aspect ratio, 2840 x 2160 (4K) native resolution, 500 nits brithness, 178 x 178 degree viewing angle, hard coating (3H) minimum surface treatment, should be anti glare treatment, should be 24 hours operational hours, should be usable in landscape or protrait modes, should have atleast 2xHDMI, DP, DVI-D, RGB, Audio, USB 3.0, should have RS232C in/out, RJ45 In, IR receiver in, pixel sensor in etc all complete.
SITC of table flip top cable manager with 2 x universal Power socket, 6 pass through holes with Net Line, USB line, VGA line, Video Line
SITC of High efficiency class D amplifier with eficiency of atleast 85%, should have reasonable heat dissipation, 1U standard 19-inch industrial standard, 2 channel digital power amplifier to provide two 100V or 4-16O output terminal wiring speaker, with 100V transformer output and can switch resistance between 4 and 16 O output., shoudl support fault output function, which can remotely monitor the working status of power amplifier, shoudl have short circuit, overload and overheating protection function, should come with atleast 2-channel Euro-type balanced input and 2-channel Euro-type output etc all complete .
SITC of table top conferencing chairman unit for fully digital conference system, should have priority function, should have functionality to initiate and end attendance sign, should have capability for voting, should have capacitive button, should operate on controller powersupply, frequency response should be 20Hz -20KHz, SNR)80dB, channel crosstalk )80db, maximum power dissipation should not be more than 1.1W etc all complete
SITC of table top conferencing delegate unit, should have capacitive button, should operate on controller powersupply, frequency response should be 20Hz -20KHz, SNR)80dB, channel crosstalk )80db, maximum power dissipation should not be more than 1.1W, should be supplied with all required accessories etc all complete
SITC of conference camera controller, should be integrate with supplied PTZ camera and digital conference controller for look at me function etc all complete
SITC of audio digital signal processor with balanced mic with atleast inputs, 2 balanced Mic/Line inputs and 1 stereo unbalanced input, 1 stereo and 2 mono outputs, 2- channel USB audio interface for soft codec (Skype, WebEx) integration or playback from computer, Full digital processing on inputs and outputs, 8 x 3 audio routing matrix, 6-channel Smart Mix (gate or gain sharing), Onboard acoustic echo canceler (AEC) processing, Front panel direct operation and Web Remote functionality, IP control for third-party CCS administration, Up to 6 mixers can be linked using Cat5e cable etc all complete
Providing and fixing of items for toilet including all accessories with fitting and labour works
Providing and fixing of wall panelling with pasting 1.25 mm thick laminate over 12 mm thick mdf/ply board over frame of aluminium section (25*50 mm) and packing all complete.
Providing and fixing of Hardware fittings and accessories to flush door shutters of height 2.40 mtr.
Providing and fixing of ISI marked flush door shutters conforming to IS: 2202 (Part-I)
Providing and fixing of 4 mm thick veneer over 12 mm thick MDF/Ply board over frame of aluminium section (25x50 mm) and polishing the veneer surface with PU matt finish polish all complete.
Bidder Name
Amount
CROSS ROAD BUILDCON PRIVATE LIMITED(GSTN-NA)
M/s Mahashiv Promoters Pvt. Ltd.(GSTN-NA)
CROSS ROAD BUILDCON PRIVATE LIMITED
M/s Mahashiv Promoters Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .