| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹17.1 L+₹50,787.97 (3.06%)Rejected-Finance | L2 | Rejected-Finance Greater than lowest | |
| 3 | L3₹18.9 L+₹2.3 L (13.8%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L3 | Rejected-Finance Greater than lowest | |
| 4 | L4₹19.1 L+₹2.5 L (15.1%)Rejected-Finance | L4 | Rejected-Finance Greater than lowest |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
20 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL MANISH KUMAR
GE (P) NDA Khadakwasla NDA Khadakwasla Pune
ADDN/ALTERATION TO DUTY ROOMS AND OFFICE AT PEACOCK BAY AT NDA KHADAKWASLA
2022_MES_565368_2
ge (p) nda tOKEN-07/8114/e8
Open Tender
Civil Works
Item Rate
180 days
GE (P) NDA Khadakwasla
As per NIT/Tender documents
8 documents required · 8 mandatory
₹500
GE (P) NDA Khadakwasla
₹39,000
Yes
16 Mar 2023
17 Jan 2023
25 Feb 2023
17 Jan 2023
20 Feb 2023
4 Feb 2023
21 Jan 2023 - 1 Feb 2023
Amount
Demolition of ceiling boards (Fibre, pulp, insulation etc) or insulation boards/slabs/ blankets, any thickness including cover fillets.
Dismantling timber scanting under 40 Sqcm in section in any position and in framed work.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.
Dismantling partition of any decription including galss gauge, particle board etc complete.
Taking down aluminium door frame exc 1.5 Sqm and n.exc 4.5 Sqm each ( with shutter)
M&L for 12mm thickness Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600mm x 600mm grid (Frame work for ceiling shall be measured and paid separately)
S&F Gl frame work Size of grid 605 x 605mm for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and direted at site.
S & F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified.
S&F for powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
S & F for powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S & F for powder coated Anodised aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Chief.
M & L for 12mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to frame work of any description.
M & L for 5.5mm thick sheet glass, ordinary quality and glazing in square n.exc (not exceeding) 0.50 sqm in each pane (excluding oil putty/Beading) complete all as specified and directed.
M & L for 5.5mm thick frosted sheet glass, ordinary quality and glazing in square n.exc (not exceeding) 0.50 sqm in each pane (excluding oil putty/Beading) complete all as specified and directed.
S&F door closer hydraulically regulated designation No-2 universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 /Kg aluminium body.
M & L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and includig 20mm thick cement screed bed in CM 1:6).
M & L for 30mm thick PCC type B0 1:2:4 using 12.5mm graded stone aggregate as floor
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out soft/loose soil
M& L for 150mm thick Hard-core of broken stone gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface etc complete all as directed
Material and labour 75mm thick Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as sub base complete as specified
M&L for Chequered cement concete tiles in floors of size 20cmx 20 cm x25mm thick, set , jointed with grey cement and no pigments and pointed in neat cement slurry complete as specified and directed.
Taking down carefully copper/aluminium point wiring (light/fan/socket) including all accessories wire, casing caping/conduit, screws etc and making good the disturbed surfaces all as specified
M & L for Point wiring with proper colour coding complete with and including PVC insulated, unsheathed, flexible bright annealed multi stranded copper conductor single core flame retardant low smoke (FRLS) cables 1.5 Sqmm (22/0.30 mm) 1100 volts grade drawn through in and including heavy grade, rigid non-metallic PVC conduits 25 mm or higher dia as required at site,Totally on walls / floors /ceiling and surfaces on trusses by means of saddles & clips etc including all conduit accessories, fittings including PVC box with cover plate of heavy grade, ISI marked for mounting of switches, sockets fan regulators etc; including 1.5 Sqmm (22/0.30 mm) 1100 V grade PVC insulated FRLS, unsheathed flexible, multi stranded, copper conductor cable(green colour) as continuous earthwire connected to metallic bodies of luminaires/fans etc; at one end and to common earth dolly at other end, all as specified and directed for following :- (a) One light/Fan/Exhaust Fan point controlled by one, one way switch 6 Amps 240 Volts.
(b) One 3 pin 6 Amp Socket outlet point on Same board including earth wire as per description given above and connected to common earth and earth terminals.
(c) One 3 pin 6 Amp Socket outlet point on Independent board including earth wire as per description given above and connected to common earth and earth terminals.
(d) All as per description of serial item No 2 here -in -before but for 3-pin socket out let 15 Amps on independent board with cable size 2.5 Sqmm Multi std.copper conductor PVC insulated cable 1100 volts grade with continous 2.5 Sqmm earth wire.
S&F socket outlet 3pin, 6 Amps flush type (ISI Marked) controlled by one way switch complete all as specified and as directed by Engr-in-charge.
S&F Switch piano flush type 6 Amps single pole one way.
S&F socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type (ISI Marked) controlled by one way switch complete all as specified and as directed by Engr-in-charge.
S&F Switch piano flush type 16 Amps single pole one way.
S&F ceiling rose surface type PVC 50 mm dia 3 terminals including PVC mounting block complete all as specified and as directed.
S & F PVC rectangular block for mounting, switches,sockets,fan regulator etc. With 2mm thick plastic laminated sheet cover of size 250mmx200mmx50mm deep all as specified and directed by the Engr-in-Charge. Note : 04 Nos of S/S comb. shall be fixed on one PVC Rectangular block. Separate submain wiring of size 4.00 Sqmm shall be provided for each block from main DB. Cost of Switch/Socket and Sub Main Wiring shall be paid separately against respective Item of Sch.
M & L Switch socket combination 2 in 1, 3pin 6 and 16 Amp flush type universal complete all as specified and directed by Engr-in-Charge. 04 Nos of S/S comb. shall be fixed on one PVC Rectangular block.
S&F of decorative ultra slim liner LED lighting fixture with extruded aluminium heat shrink, environmental friendly, energy efficient of capacity 20 Watt LED,20 Watt tube rod, connecting accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
S & F exhaust fan, steel body, single phase, heavy duty, Metal frame,300 mm sweep, 1400 RPM including fixing of mounting frame in the round hole cutting in the wall/partition board/MS Sheet as per site, by means of rugged bolts, nuts and washers etc, including three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of the exhaust fan complete all as specified and directed. Note:- Cost of Exhaust Fan includes the cost of GI air Louvers 16 SWG.
S & F Wall Fan 400mm Sweep, striker Hi speed, Air delivery 100 m3/min, 2000rpm,power input125W with pull cord switch for speed and oscillation regulation including installation,commissioning and testing completeall as specified and directed by the Engr-in-Charge.
S&F MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 100 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete all as reqd at site.
S&F MCB DB 08 way SPN double door sheet metal enclosure factory made suitable for MCB DB's 240 volts with 100 amp rated busbar, neutral & earthing link bar,surface mounting complete including taking down the existing DB of any type & size alongwith its accessories by removing from existing circuits and refixing the new DBs and circuits complete all as reqd at site.
S&F MCB SP 6 to 32 Amps 240V,10 KA breaking capacity , C curve as per IS/IEC 60898-1 2002 with IP 20 protected terminals all as specified including complete connection with copper /aluminium cable lugs with suitable size for incoming and outgoing.
S&F MCB SPN 32 AMP, 240V,10 KA breaking capacity , C curve as per IP 20 protected terminals all as specified including complete connection for incoming and outgoing.
M & L for Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia medium grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg)/transformer/LT kiosk/HT lightening arrestors etc. including GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia light grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata & testing on completion including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed. Note :- Earth protection pipe & earthing lead wire upto and including 7.5 m length is deemed included in unit rate quoted by the contractor.
S & F of Wiring for circuit/submain wiring of size 2x4.0 sq. mm +1X4 sq. mm earth wire of FRLS (multistrand) is PVC insulated copper conductor, single core cable in PVC casing/caping complete all as specified and directed.
S & F of Wiring for circuit/submain wiring of size 2x6.0 sq. mm +1X6 sq. mm earth wire of FRLS (multistrand) is PVC insulated copper conductor, single core cable in PVC casing/caping complete all as specified and directed.
Material & Labour XLPE insulated, armoured heavy duty electric cable with aluminium conductor,1100 Volts grade, cross-sectional area 16 Sq. mm, 4core including laying on wall /floor/through pipe connectingand testing complete all as specified and as directed by the Engr-in-Charge
M/S SHREE CONSTRUCTIONS
Sunil Constructions
M/S Narendra Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .