Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC | L1 | Accepted-AOC Lowest Acceptance Bidder. | |
| 2 | L2₹35.2 L+₹3.1 L (9.68%)Rejected-Finance WARD NO 40 REGRON KA MOHALLA NEAR RAVI DASS JI MANDIR SHIV BARI BIKANER RAJSTHAN 334001 | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance Higher Rate Quoted. | |
| 3 | L3₹37.3 L+₹5.2 L (16.2%)Rejected-Finance 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | L3 | Rejected-Finance Higher Rate Quoted. | |
| 4 | L4₹39.9 L+₹7.7 L (24.1%)Rejected-Finance | L4 | Rejected-Finance Higher Rate Quoted. | |
| 5 | L5₹40.9 L+₹8.8 L (27.3%)Rejected-Finance | L5 | Rejected-Finance Higher Rate Quoted. |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Mar 2023, 6:00 pmClosed
CWE Bikaner
HQ CWE Bikaner, Mil Stn Bikaner, PIN-334001
Repair/Replacement of electric wiring and panels at MD Accn under AGE BR-II under GE (N) Bikaner at Bikaner Mil Stn
2023_MES_582208_1
CA No CWE BKN-Token No. 80/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Bikaner
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE (N) Bikaner
₹90,000
Yes
13 May 2023
21 Feb 2023
27 Mar 2023
21 Feb 2023
20 Mar 2023
8 Mar 2023
21 Feb 2023 - 25 Feb 2023
Amount
Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/ batten aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/Ex-fan/ bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one light point controlled by two, two way switches complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, one way, 15/16 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F switch piano, flush type, single pole, two way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F bell push, flush type, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 3 pin, 5/6 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed.
S&F ceiling rose, PVC/Polycarbonate insulated body, 65mmx50mm with three terminals, ISI marked, complete all as specified and as directed.
S&F lamp holder, PVC/Polycarbonate insulated body with back plate suitable for conduit/ casing caping fittings, ISI marked, complete all as specified and as directed.
S&F electronic fan regulator, flush type, stepped type with 5 step control, 230 Volts, 150 Watt, including making hole in sheet top cover and connecting up, ISI marked, complete all as specified and as directed.
Supply and fixing Bell ‘Ding Dong’ / ‘Multi Music’ Type, AC, 230 Volts, ISI marked, complete all as specified and as directed.
Taking down of serviceable and refixing after LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt 240 Volt, 50 Hz AC, ISI Marked decorative type with driver holder and LED lamp, correlated colour temperature shall be minimum 6500 degree Kelvin, including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Taking down of serviceable and refixing after LED tube light fitting, 1x20 Watt, 230 Volts, basic all purpose surface and wall mounted LED batten type with driver & polycarbonate housing including tube rod and all accessories, prewired and connecting up with & including 3 core sheathed flexible copper cable 1.5 sqmm of suitable length upto light point/ceiling rose, complete all as specified and as directed.
S&F of 200w plano convex spot light with having CRI TLCI values and above 95 high precision steady colour, No heat, DmX512 Dimming with 2 channel beam angle 15/25/45 degree, 0-100%, powder coated black finish housing rigidly built pressure die casted aluminium body LED easy view display Flicker Free for high EPS smooth fade in and Fade out Data DmX through 3/5 Pin XLR's Total Power Consumption of 200W IP 20 protection, Model : Legacy LED 200S, Make Modern Stage Service including taking down old unserviceable light complete all as specified and directed. Note : (i) Working heights is approximate upto 15-20 meters. (ii) All T&P, Folding & staging material are included in quoted rates (iii) Contractor has its own responsible to visit at sites before quoting of rates. (iv) No damage of existing ceiling & movie screen & other assets of auditorium will be acceptable, damage if any will be made good by the contractor. (v) Payment will be made only once after complete set of light have heen changed.
S&F of 200 watt LED Profile spot with lamp power : 200 watt, Power supply 100V-220V, 50 Hz, Beam Angle 19 degree, Control : DmX Auto run and master/slave, CRI:>90, Colour Temperature 3200K, shutter : beam shaping shutter or plasticgobo projection assembly, IP Rate : 20, Model : Legacy LED 200PS, make : Modern Service including taking down old unserviceable light complete all as specified and directed. Note : (i) Working heights is approximate upto 15-20 meters. (ii) All T&P, Folding & staging material are included in quoted rates (iii) Contractor has its own responsible to visit at sites before quoting of rates. (iv) No damage of existing ceiling & movie screen & other assets of auditorium will be acceptable, damage if any will be made good by the contractor. (v) Payment will be made only once after complete set of light have heen changed.
S&F of 100W full power light source, Warm Cold : 3200K and Cold white : 5600 K, 6 meters effective range, 10000 hours lifespan, 2/4 channels (4 Control Mode) Automatic / Rapid Response Sound Active / Master Slave Mode / DMX-512 remote controller (Features) Y axis 180 Degrees and stable mounting brackets ensure the light can be wall hanging of uplighting, (Occasion) Professional stage lighting kits, supper bright for stage show, Home Party, street Live, Cinema, Photography, IP 20 protection, Model : Legacy LED 100F, Make : Modern stage Service including taking down old unserviceable light complete all as specified and directed. Note : (i) Working heights is approximate upto 15-20 meters. (ii) All TNP, Folding & staging material are included in quoted rates (iii) Contractor has its own responsible to visit at sites before quoting of rates. (iv) No damage of existing ceiling & movie screen & other assets of auditorium will be acceptable, damage if any will be made good by the contractor. (v) Payment will be made only once after complete set of light have heen changed.
NOTES FOR LED LIGHT FITTINGS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 Amp, 230 Volt, 10 kA, ‘C’ Curve, fixed in repairs, complete all as specified and as directed.
S&F sheet metal enclosure for distribution boards, double door type, suitable for fixing MCCBs, 415 Volts with 200 Amps rated bus bar, load line DB fitted with bus bar neutral links blank plates, TPN DB, vertical type, 4 way, suitable for MCB, fitted with and including accessories, complete all as specified and as directed including taking down old existing unserviceable DB with fixtures of any type & capacity. Note : Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, DB SPN with 200 Amps rated bus bar, 12 way, 240 Volts, including taking down old existing unserviceable DB with fixtures of any type & capacity complete all as specified and as directed.
S&F sheet metal enclosure, double door type, suitable for fixing MCBs, DB SPN with 200 Amps rated bus bar, 8 way, 240 Volts, including taking down old existing unserviceable DB with fixtures of any type & capacity complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, Single Pole, 240 Volts, rupturing capacity 10 kA, ‘C’ Curve, with over load and short circuit protection, including taking down old existing unserviceable MCB with fixtures of any type & capacity complete all as specified and as directed.
S&F MCB, 6 to 32 Amps, SPN, 240 Volts, rupturing capacity 10 kA, ‘C’ Curve, with over load and short circuit protection, including taking down old existing unserviceable MCB with fixtures of any type & capacity complete all as specified and as directed.
S&F MCCB 4 Pole 40 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F MCCB 4 Pole 63 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
S&F MCCB 4 Pole 100 Amps, thermal magnetic having, breaking capacity 16 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
M&L for taking down carefully existing serviceable ceiling fan with down rod of any sweep dismantling blades and removing fan and blades and re-fixing ceiling fan, keeping side in store in safe custody for painting of ceiling fan complete in-situ with synthetic enamel paint by spraying including filling cavities with filler one coat after proper cleaning and connecting up with and including writing MES No. at site complete all as specified and as directed.
M&L for taking down carefully existing serviceable exhaust fan of any sweep, dismantling blades and removing fan and blades and re-fixing exhaust fan, keeping side in store in safe custody for painting of exhaust fan complete in-situ with synthetic enamel paint by spraying including filling cavities with filler one coat after proper cleaning and connecting up with and including writing MES No. at site complete all as specified and as directed.
M&L for carefully disconnecting electric & water connections and taking down existing serviceable Geyser (water storage type) of capacity 25 litre vertical type and re-fixing the same with wall grouted properly to hold the geyser and making good the disturbed surface as original and re-connecting electric & water connections, complete all as directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40 mm thick RCC pit cover, etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through existing PVC conduit ISI marked including fittings/accessories, fixed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through existing PVC conduit ISI marked including fittings/accessories, fixed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes:- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLSH with multi-stranded copper conductor, 1100 Volts grade, ISI marked cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified and directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Taking down old unserviceable existing iron box size 300x300mm and 450x900mm including MCB/MCCB of any capacity and any size and removing from site and filling brick work with plaster making good the distrubed surface of wall etc complete all as specified and directed.
Repair to existing panel board indoor type sheet metal approximate size (5x51.5 feet) parts tinkering the parts and replacing fully corroded sheet metal parts like base plate, top plate, front cover etc with appropriate gauge MS sheet including bending to match with the existing size welding, brazing and assembling including replacing all nuts & bolts in MCBs and proper legging in cable and control wire sheet metal screws and replacing of unserviceable volt meter, Amp meter and CT, PT and painting complete body with two coats of synthetic enamel paint over a coat of zink chrome primer and marking the quarter No, panel board no in front side and complete all as specified and directed by Engineer-in-Charge and tested on completion.
B.K. ROY & SONS
A.S. CONSTRUCTION COMPANY
ENGINEER CORPORATION OF INDIA
ALPHA ENGINEERING COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .