Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹23.0 L+₹51,875.68 (2.31%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹25.0 L+₹2.5 L (11.3%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹24.9 L
EMD Value
₹49,720
Closing Date
13 Dec 2022, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin 152116
Special repair of Personal line and Renovation of Toilets and Bathroom of Bldg No P-353 of 175 MH at Mil Stn Abohar.
2022_MES_563130_1
GE ABH-49/22-23
Open Tender
Civil Works
Item Rate
180 days
Abohar mil stn
As per tender document
7 documents required · 7 mandatory
₹500
GE ABOHAR
₹49,720
Yes
21 Jan 2023
15 Nov 2022
15 Dec 2022
15 Nov 2022
13 Dec 2022
29 Nov 2022
Amount
SCHEDULE 'A' SECTION I (B&R Portion)
Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof roof complete all as specified and directed by Engineer-in-Charge.
Dismantling of Brick tiles or terracing tiles, single layer on roofs complete all as specified and directed by Engineer-in-Charge.
M&L 40mm thick brick tiles laid on tiles are bedded in cement mortar (1:6) or lime mortar (1:3), 15mm thick and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound as described in para 11.27.3 of MES SSR Prt-I complete all as specified and directed by Engineer - in - Charge.
Ditto ser itme no 04 above but except bricks tiles complete all as specified and directed by Engineer - in - Charge.
M&L provide a layer of lime concrete with minimum thickness at edge 40mm and incresing unigormlu towards ridges to obrain a chain slope of (1:40) as described in para 11.27.2 of MRS SSR Prt-I complete all as specified and directed by Engineer - in - Charge.
M&L Preparing surfaces of old roof slab and cleaned of all foreign materials such as fungues, moss, dust etc, bu wire brushing dusting, sprinkling water on the surface and ensure water does not stand any where. If it is so, the roof surface shall be levelled then surface shall be painted with one coat of cold aplied bitumious primer @ 0.40 ltr per sqm, applied over primed surface APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm)land on primed surface by forced application complete all as specified and directed by Engineer - in - Charge.
Providing and injecting appoved grout in proportion Stirrer mixed Acrylic Polymer of approved make @ 2% of weight of cement used ) modified cement slurry non shrinx compound in concrete /RCC work. made with recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of GE. Note:- The payment shall be made on the basis of actual weight of approved grout injected complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete ( un re-inforced) of any description in roofs, floors(other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed by Engineer - in - Charge.
Method 1 (A) - Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, SmartCare Damp Block 2K or approved equivalent , having 100 % elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5.Clean all working surface & made free from dirt, grease laitance etc. After inspection for all working area rough surface, cracks & construction joint are treated by polymer modified mortar of 1:1:4 (1 Cement : 1Polymer : 4 Sand).Making Gola of size 75X75mm at junction of vertical & horizontal with the polymer modified mortar of 1:1:4 . (1 Cement : 1Polymer : 4 Sand). The coating shall be terminated at 300mm on vertical walls. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing and shall have consumption of 1.5kg/sqm per coats, etc., complete as per manufacturers specifications. (B) Bore Packing: All the borehole gaps between concrete surface and pvc pipe of various dia upto the neck level shall be filled with non-shrink free flow grout - SmartCare GP Grout or approved equivalent having dual shrinkage compensation property. Before the bore packing, surface of the pvc pipe and concrete surface will be made rough and sand will be sprinkled with polymer bonding agent. (c) Apply 12-15mm plaster on slab and vertical surface admixed with SmartCare Vitalia Neo @200ml per bag of cement
Method 2 (A) M & L for water proofing treatment to RCC sunken slab and adjoining vertical slab, Providing & applying two component cementitious & acrylic flexible waterproofing & protective coating, two coats with 1mm DFT, having Hydrostatic (positive) water pressure resistance (DIN 1048) is 7. Abrasion resistance, cm/km is 0.09 of Dr Fixit Pidifin 2k @ 1.5kg/sqm or equivalent with a paint brush over existing roof surface. The Polyester reinforced coated net of 45g/m2, 2.5mmx2.5mm is Laying on the surface immediately on the first coat of two component modified polymer Dr Fixit pidifin 2k or equivalent. After removal of all loose materials like dust etc. With wire brush coir brushes from roof surface to get absolutely cleaned surface free of foreign contaminant filling of crack and patches with polymer based repair mortar/micro concrete, after the repairing work making the gola on surrounding wall’s junction and seal the vertical walls up to 300mm. In case of core cutting on the surface, the joint is seal with non-shrink grout. The work complete as per the direction of Engineer-in-Charge. (Work shall be executed through specialized agency) Note: (i) The treatment shall be carried out as per the manufacturers instructions and as directed by the Engineer in charge. The name of firm shall be got approved from CWE before carrying out the work. (ii) The Plan area of floor shall be considered for payment and provn of cement work is excluded from quoted rate for this item. (iii) Plaster shall be measured and paid separately. (iv) PCC filling under sunken area will be measured & paid separately OR:- Techno commercial equivalent in Fosroc/Sika/STP
Providing plain cement concrete Type E-2, 1:5:10 (40 mm graded stone aggregate as in foundation, filling and mass concrete) complete all as specified and directed by Engineer-in-Charge.
Material & labour for 75mm thick PCC 1:3:6 type C1 using 20mm graded stone aggregate as in hard standing ,plinth protection/path etc, laid in suitable panels not exceeding 3.00 m length finished even and smooth without using extra cement with 10mm Joints filled with bituminous sealing compound of grade ‘A’/bitumen mastic filler/sealant complete all as specified and directed by Engineer-in-Charge.
M & L applying three coat of white wash on newly plastered or unplastered ceiling surfaces including preperation of surfaces, complete all as specified.
Taking down cement plaster/dado on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified .
M & L rendering 15mm thick on fair faces or other than fair faces of brick work in CM 1:6 finished even & smooth without using extra cement all as specified .
M & L Rendering 15 mm thick on fair faces of brick work or concrete surfaces, in cement mortar (1:4), in two layers of 10+5mm thick with using water proofing compound @3% by weight of cement in top layer of 5mm thick as per manufacturer's instructions, surfaces finished even and smooth without using extra cement complete all as specified.
M & L 5mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge .
M & L Washed stone grit plaster on exterior walls in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per sqm, top layer 15 mm cement plaster 1:1/2:2 (1 cement :1/2 coarse sand 2 : stone chipping 10 mm normal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to be expose the stone chippings complete all as specified (Payment for providing grooves shall be made separately).
Forming groove of uniform size 15 mm wide and 15 mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specification and direction of the Engineer-in-Charge.
Supply only liquid water proofing compound complete all as specified and as directed by the Engineer-in-Charge. Make : Dr Fixit/Fosroc/BASF/STP
M&L for preparation of old decorated, plastered or pointed surfaces of ceiling and applying one coat of white wash complete all as specified and directed by Engineer-in-Charge.
M & L two coats of cement base paint over new plastered surface including preparation of surface complete all as specified and directed by Engineer - in - Charge.
M & L two coats of cement base paint over old surface including complete removal of existing surface complete all as specified and directed by Engineer - in - Charge.
M & L Preparation of newly plastered surfaces by applying two coats of interior grade wall putty and making it smooth with sand paper by mechanical method i.e. with hand electric grinder then applying two coats of Acrylic distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun all as specified and directed by Engineer-in-charge.
M & L Preparation of Old plastered surfaces by removing old treatment and applying two coats of interior grade wall putty and making it smooth with sand paper by mechanical method i.e. with hand electric grinder then applying two coats of Acrylic distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun all as specified and directed by Engineer-in-charge.
Demolition of brick work built in cement mortar complete all as specified and directed by Engineer - in - Charge.
M&L for Brick work using old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
All as above items 27 but except bricks all as specified .
M & L for brick work in half brick thick wall using bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer - in - Charge.
Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) and rubbish off the premises complete all as specified and directed by Engineer - in - Charge.
M & L for Glazed ceramic light shade tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match in vertical surface in neat cement slurry and pointed in white cement paste pigmented to the shade over 10mm thick cement sand screed (1:4) complete all as specified and directed by Engineer - in - Charge.
M & L for non skid ceramic colour (light shade) joint free tiles with matt finish, 7 to 8 mm thick ( square/ rectangular ) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:6) complete all as specified and directed by Engineer - in - Charge.
M & L Machine cut kota stone slab flooring 20 - 25 mm thick size 550mmX450mm and in single piece on treads over cement screed base laid over and including 15mm thick screed bed in cement mortar 1:6 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as specified and directed by Engineer - in - Charge.
M & L Machine cut kota stone slab 20 - 25 mm thick in riser of steps,in single piece, skirting,dado and pillar over cement screed base laid over and including 10mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing complete all as specified and directed by Engineer - in - Charge.
M&L Granite 18 mm thick(of any type) works (table rubbed and polished) in step, window cills, cooking platforms and the like in cement mortar (1:4), 20 mm thick and width not less than 600mm including pointing in white cement (1:2) using marble dust with admixture of pigments to match
Demolition of cement concrete (reinforced) in roof , floors (other than ground floor ), beams, staircase, landing,chajjas and similar suspended work complete all as specified and directed by Engineer - in - Charge.
M & L mild steel TMT bars 10mm dia or over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as in column, beam etc complete all as specified and directed by Engineer - in - Charge.
M&L Reinforced cement concrete 1:11.5:3 Nominal mix, type using 20mm graded stone aggregate in slab supported on walls,beams and columns in floors,roofs,landings,balconiies,deck slabs and in shelves and the like all as specified and directed. (form work & reinforcement measured separately) complete all as specified and directed by Engineer - in - Charge.
M&L for Formwork to soffits of suspended slabs, such as roof slabs, floor slabs landing and similar work not exceeding 200mm thick (Horizontal & sloping) fair finished surfaces (Note- Steel props to be use). complete all as specified and directed by Engineer - in - Charge.
M&L for From work to edges of concrete flats treads breaks in floors, window cill concrete railing, opening in convert valley floor and roof exc 5 but n.exc 10 cm wide and sides RCC/PCC band in walls complete all as specified and directed by Engineer - in - Charge.
Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as specified and directed by Engineer - in - Charge.
Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each and complete all as specified and directed by Engineer - in - Charge.
S&F Factory made box type steel window with hung shutter both glazed and gauged ,shutter frame 60x25mm ERW hollow 'P' section with wall thickness not less than 1mm fixed to pressed steel frame 120mmx 70mmx1.6mm thick including fixing glazed portion, iron grills 8mm square MS bar hinges with steel handle and fitting, lugs etc, including one coat of primer complete all as shown in drg No BTD 889 sheet 1/4 to 4/4 for size and specification of members . Arrange of shutters to be done accommodate provision for coolers. (Note :- Wire mesh and glass shall be measured and paid separately under relevant items of such/BoQ)
S & F 4 mm thick sheet glass ordinary quality and glazing with in square not exceeding 0.50 sqm including aluminium cleat/rubber beading in each pane complete all as specified and directed by Engineer - in - Charge.
S & F figured glass 4 mm thick pin head type and glazing with not exceeding 0.50 Sqm including aluminium cleat/rubber beading in each pan complete all as specified and directed by Engineer - in - Charge.
S&F Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge. Make- "Fiber ways, Rajshree, sintex, polycon.
Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge. Make- "Fiber ways, Rajshree, sintex, polycon.
S & F pressed steel door frames size of 125X60mm thickness of sheet shall be 1.25 mm with one or more rebates including necessary fixing lugs hinges lock strike plate etc complete all as specified and directed by Engineer - in - Charge.
M&L Cement concrete 1:3:6 type C-1 for filling of pressed steel frame, post hole and hold fast blocks etc complete all as specified and directed by Engineer - in - Charge.
S & F Factory made 35mm thick IInd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; size of members of shutters as specified in SSR Part – I, Section – 8, clause 8.20 (a) ; supplied and fitted to chowkats complete all as specified and directed by Engineer - in - Charge.
S & F in 12 mm Wire mesh netting of stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples all as specified .
S & F Factory made Plain framed, panelled shutter IInd class hardwood rail and style 35 mm thickness (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer - in - Charge.
S & F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed by Engineer - in - Charge.
S & F tower bolt 150 mm of aluminum complete all as specified and directed by Engineer - in - Charge.
S & F door handle D type 150 mm of aluminum complete all as specified and directed by Engineer - in - Charge.
S & F Aluminium alloy, anodised, sliding door bolt 300mm with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F Floor door stopper of aluminum alloy body and tongue, 150mm overall length, anodised, with hard drawn steel spring, fixed in floor.
S & F mild steel 300mm ordinary rat rail rod pattern spring including roller and roller plate complete all as specified .
M & L providing two coats of synthetic enamel paint over new wooden surface including preparation of surface with primer all as specified .
M & L providing two coats of synthetic enamel paint over new steel surfaces and a coat of red oxide primer on including preparation of surface of any description not exceeding 10 cm width or girth complete all as specified and directed by Engineer -in -charge.
S & F repair vitreous china squatting pan Orrisa pattern size 580mm x 440mm white with integral foot rest with CI ‘P’ or ‘S’ trap and fixing in lime concrete (1 lime, 2 sand and 5 aggregate), 150mm thick all round and finished just below level of rim of pan to receive the floor finishing all as specified .
S & F in repairs PVC 10 ltrs symphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified .
S & F in repairs vitreous china oval wash hand basin white of size 550X400 mm including brackets 300mm long PVC connection with brass nuts, 40mm dia waste coupling including cutting for and pinning in end of brackets or erecting stand etc coloured top bowl type screwed shank fly nut flange end including cutting for and pinning in granite slab of hole including 32 mm dia chromium plated waste coupling and bottle trap all as specified .(MAKE- Hindwareor equivalent in Parryware)
S&F in repair 15mm bore bib taps,chromium plated, fancy type, cast copper alloy with crutch or butterfly handle , screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engr-in- charge.
S & F in repairs 15mm bore Angle cock one way chromium plated, high pressure, with crutch or butterfly handle, screwed both ends of iron pipe or for union and fixed all as specified .
S&F in repair brass chromium plated central hole basin mixer with regular spout,popup waste system and 450mm long braided hoses with connection and nuts complete all as specified and directed by Engr-in-charge.
S & F in repair PVC connection 15mm size with PTMT nuts of length 450mm all as specified .
S&F in repair Swivel shower of Chromium plated any colour with shower arm 15 mm size 195 mm long with bend of 45 degree with flange of any colour for fixing with 15mm pipe. (Minimum weight 40gms) .
S&F in repair Towel Ring of Chromium plated fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms)
S&F in repair Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden plastic cleats.(Minimum weight 190gms)
S&F peg set of stainless steel solid body of 125mm to 175 mm having 6 Nos hooks fixed with brass chromium plated screws complete in all as specified
S & F in repair soap dish approximately size 160 x160x 90 mm and fixed with as chromium plated brass screws complete all as specified and directed by Engineer -in -charge. Make ESS ESS-AC-103
S&F for in repair PVC corner shelf with bracket complete all as specified and directed by Engr-in- charge.
Taking down steel tubing 15mm bore and connections complete all as specified and directed by Engineer - in - Charge.
Fixing only tubes any grade 15mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) complete all as specified and directed by Engineer - in - Charge.
S & F 15mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer - in - Charge.
Taking down steel tubing 20mm bore and connections complete all as specified and directed by Engineer - in - Charge.
Fixing only tubes any grade 20mm bore to walls and ceiling or in floors etc including provision of new fittings as required (Serviceable galvanised tubes retrieved from respective items shall be laid under these items) complete all as specified and directed by Engineer - in - Charge.
S & F 20mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer - in - Charge.
S & F 40mm bore medium grade tube galvanised with all fittings and fixed complete concealed including groove cutting for concealing to walls & ceiling or laid in floor complete all as specified and directed by Engineer - in - Charge.
Dismantling water tanks of 500 ltrs and removing to store complete all as specified and directed by Engineer - in - Charge.
S & F rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Liters all as specified and directed by Engineer - in - Charge .
M&L Ball brass valves 20mm, high pressure, with polythene float and fly nut complete, screwed for iron pipe of following description complete all as specified and directed by Engineer - in - Charge..
S & F in 20mm bore gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed all as specified .
Taking down CI/AC/PVC soil waste and vent pipe any radius including all fittings complete complete all as specified and directed by Engineer - in - Charge.
S&F, 110 mm uPVC (SWR) pipe singal shocket (Pressure not less than 6kg/cm2) , waste and vent pipes, in any length with rubber ring joints,laid in fixed to walls with PVC stack clamps, complete all as specified and as directed by Engineer-in-Charge.
S&F, 75 mm uPVC (SWR) pipe singal shocket (Pressure not less than 6kg/cm2) , waste and vent pipes, in any length with rubber ring joints,laid in fixed to walls with PVC stack clamps, complete all as specified and as directed by Engineer-in-Charge.
S&F for 110mm bore PVC (SWR) bends any radious provided with access door (Pressure not less than 6kg/cm2) complete all as specified and as directed by Engineer-in-Charge.
S&F for 75mm bore PVC (SWR) bends any radious provided with access door (Pressure not less than 6kg/cm2) complete all as specified and as directed by Engineer-in-Charge.
S&f PVC(SWR)110mm bore junction (singleT) equal or unequal complete all as specified and directed by Engineer - in - Charge.
S&f PVC(SWR)75mm bore junction (singleT) equal or unequal complete all as specified and directed by Engineer - in - Charge.
S & F PVC(SWR) 75 mm bore vent cowls complete all as specified and directed by Engr-in-charge.
S&F for 75 mm bore PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as specified and directed by Engineer - in - Charge.
S&F 32 mm High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches complete all as specified and as directed by Engineer-in-Charge.
M& L PCC 1:2:4 type B1, using 20 mm graded agg.as in bed blocks ,coping, hold fast blocks etc.
Excavation in post holes each n. exc. 0.50Cum, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25cm, watering and removing surplus soil to a distance n. exc. 50m and makin
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out
M & L for PCC 1:3:6 type D2 using 40 mm graded stone aggregate in foundation filling and mass concrete.
M&L for Machine pressed precast concrete coloured with grey cement and pigment interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-40 Grade complete all as specified and directed.
M&L for 25 mm thick layer of Fazilka sand cushioning under interlocking paving block flooring all as specified and directed.
M&L for PCC 1:4:8 Type D-2 100 mm thick as in sub base all as specified.
S & F Steel work in tubular trusses including shaped washer etc complete using welded tubes ,all as specified and directed by Eng-in-charge
S&F Pre- painted galvanised aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
M&L for Brick work using fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge.
M&L for three coat white wash to the wall surfaces after preparation to the new plastered surfaces .
S & F MS Plate 6 mm thick as in gusset plate in Fe 410 incl necessary welding.
SCHEDULE 'A' SECTION II (E&M Portion)
Excavation in trenches , n exc 1.5m wide and n exc 1.5m in depth , for foundation , etc or for shaft, well, cesspits , manholes , pier hole etc n exc 1.5 m in depth and getting out comlete all as specified.
Returning , filling in including, spreading , levelling , watering and well reamming in layers not exc comlete all as specified.
Removing excavated material n exc 50m and depositing where as directed at a level n exc. 1.5 m above the starting point comlete all as specified.
Sand filling under flooors or in foundation including and consolidation as as specified and directed at site comlete all as specified.
M & L brick sub class 'B' locally available best quality laid in trenches above sand consolidted forcable protection complete all as specified and directed.
Supplying, laying, jointing and testing XLPE PVC insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 50 sqmm 3.5 core conforming to IS- 1554 laid in trenches/ ducts/ along poles/ through pipes including provision of cable gland/aluminium lugscomplete all as specified & directed by Engineer-in- charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
Taking down carefully copper /aluminium point wiring (light ,fan ,socket or power) complete incl fixture and fitting such as Switches, ceiling roses, pandents, regulators,sockets, light fitting etc removing materials to store for keeping in safe custody for taking credit(credit for above items shuold be made as per conditions separately) and making good distrubed surface of wall ,floors etc. complete all as specified and as directed.
M & L point wiring (Concealed) with PVC FRLS insulated unsheathed multistranded copper conductor drawn in and incl of size 1.5 Sqmm, 1100V grade in concealed PVC regid conduit, including provn of of 1.2 mm thich pressed steel sunken terminal boxes 60mm deep,suitable lenthand painted with red oxide primer for mounting switches, sockets, fan regulators covered with and including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5Sqmm PVC insulated stranded copper conductor as earth continuity wire and connected to common earth dolly with copper lugs inserted in including MS boards complete heavy duty for housing switches, sockets, regulators, bell push etc, complete for One light/Bell/fan point controlled by one way switch 5 Amp all as directed for the following.
All as per above here in before but one 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq mm size complete.
All as per above here in before but one 3 pin socket outlet, 5 Amps on independent board with other switches, with cables 1.5 sq mm size complete.
All as per above here in before but with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified.
Description all as per above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.
M & L point wiring with PVC FRLS insulated unsheathed multistranded copper conductor of size 1.5 Sqmm, 1100V grade in Existing concealed conduit, and one run PVC FRLS insulated unsheathed copper conductor of size 1.5 Sqmm as earth continuity wire and connected to common earth dolly with copper including provn of of 1.2 mm thick pressed steel sunken terminal boxes 60mm deep suitable lenth and painted with red oxide primer in place of unserviceable shunken box complete for housing switches, , regulators, bell push etc, for One light / fan point controlled by one way piano switch 5 Amp. complete all as directed for the following.
All as per above here in before but One socket point 5 Amp on an independent board.
All as per above here in before but One socket point 5 Amp on same board
All as per above here in before but with cable of 2.5 sq mm for 15 amps Socket Independent board with other switches complete all as specified.
S & F switch piano ,flush type single pole, one way 5 amp, all as directed.
S & F switch piano ,flush type single pole, one way 6/15 Amps 5 pin complete all as speccified aand directed.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps complete.
Supply and fix in replacement of socket outlet 2 in 1, 3 pin 5 Amps and 15 Amps complete.
M & L for celling rose 3 pin/pvc/ polycarbonate isolated body complete all as specified and as directed.
S&F batton holder insulated body with back plate inluding 12 watts LED lamp complete all as specified.
Supply and fixing fan regulator electronic (socket) type, single phase, 230Volt complete all as specified and directed Make: Anchor/Cona and equivalent make
M&L for LED tube light fitting of LED T5 tube lights (6500K) environomental freiendly energy efficient of 18/20 Watt LED including electric connection with PVC copper flexible twin core cable, 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska SSK-SQ2001 20W or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron of 4 sqmm SWG earht wire fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and water pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge Notes :- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip upto DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
S&F sheet metal enclouser TPN DB having facility to fix MCCB incomer upto 125Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
S & F in sheet metal enclosures for DBs double door type when MCBs to be used single pole & nuteral 8 ways s all as specified and directed by Engg-in-Charge.
S&F MCB SPN 63 Amps, 240 Volts complete all as specified.
S&F MCB SP 6 to 40 Amps, 240 Volts complete all as specified.
M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits and conduit fittings/existing concealed PVC conduit and conduit fittings not less than 25 mm dia complete, including provision of 2x6 sqmm nominal cross sectional area multimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS and specified and making good all disturbed work to match the existing complete incl taking down old UNSV sub main all as specified. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Description all as per above here in before but ,2 Runs of 6 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed.
Description all as per above here in before but ,2 Runs of 4 sqmm nominal cross section and including provision of 1X4.0 sqmm nominal cross sectional area for earth wire complete all as specified and directed.
M & L cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as directed by Engr-in-charge .
S & F LED street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge. Make:Syska max glow series SSK-ST25W-MG or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab as recommended by Engr-Incharge and approved by GE.
Supply and fixing MCCB TPN ( 4 pole) 63 Amps 415 Volts of braking capacity 36 KA (Adjustable Thermal and Adjustable Magnetic Release Setting) complete taking down old unserviceable one and making necessary connections as existing and cleaning the terminals with CTC solutions complete all as specified and directed. Make :IndoAsian Cat No: 830330 to 830335 or equvalent of Havells/LegrandSchneider/HPL/Standard
S & F GI tube light grade galvanised of size 50 mm with all fitting and fixed to wall and celling or laid in floors for cable protection complete all as specdied and directed by Engineer-in- Charge.
Taking down/ dismantling complete ceiling/exhaust fan of size 1200/1400/300/380/450 mm sweep.with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of Exhaust/ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete exhaust fan fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :- Ball bearing and Gun metal bush are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in Schedule Items)
S&F for Condenser 2/2.5 MFD. (Make : Universal (metal body/or equivalent)
S&F for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200mm/1400mm sweep.
Supply only ball bearing number of 6201/6202/6203/6204 as required. (Make : SKF/NBC or Equivalent)
Supply only gun metal bush as required.
Taking down/dismantling complete exhaust fans of any size for spray painting with two coat of synthetic enamel paint of approved colour including filling cavities with filler on coat after cleaning all dust etc. including re-assembling the same and testing after writing of MES NO on completion.
S&F Bed side light fitting of decorative type LED 5 Watt spot pattern aluminium body warm white adjustable arm shade material metal of push button corded electric complete all as specified
M&L for LED Batten with LED tube light integrated LED channel of capacity 10 Watt white colour complete all as specified and directed by Engr-In-charge. Make: Bajaj BCLSB 10WH or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Syska/Polycab as recommended by Engr-Incharge and approved by GE.
M&L for LED light fitting 1x9W/1x10W bulk head luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as directed by the Engr. in Charge.
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore pipe for 0.4 mpa working pressure for cable passing without damagingexistingRaod/path/hardstanding/floor by trenchless technology or manual using necessary equipment complete all as specified and directed.
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells Schneider/C&S)
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for hot/cold water.
S&F for copper (CP) hot water pipe 450 mm length (heavy duty) for Geyser, connection with check nut and washer.
Taking down/ dismantling of defective/rusted storage type hot water Geyser of 50/35/25 Ltr capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, de-scaling/cleaning inner shell, servicing etc. Checking defects, re-assembling and re-installing the Geyser in position, connection and testing complete.
M/s GURFATEH BUILDERS
Sanjeev Sehgal Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .