| Sl No | Description | Qty | Unit | NOEL ENGINEERS L1 | Shree Gajanan Enterprises L4 | Genius Construction Co. L2 | S S ENTERPRISES L7 | OM SAI POWER SYSTEMS L6 | Shree Ayyappa Engineering L8 | shubham construction L3 | Sri Krishna Construction L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material & Labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6 mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion including taking down old one and making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks and removed surplus materials complete all as specified and directd. NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth wire upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing. | 40 | Each Job | 5,000 ₹2,00,000 | 4,928.7 ₹1,97,148 | 4,400 ₹1,76,000 | 4,000 ₹1,60,000 | 5,000 ₹2,00,000 | 6,500 ₹2,60,000 | 2,500 ₹1,00,000 Lowest | 4,000 ₹1,60,000 |
| 2.00 | Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) after taking out old, U/S one complete all as directed by Engineer-in-Charge. Make- JEF Ecosafe or equivalent as approved by GE. | 35 | Each Job | 4,200 ₹1,47,000 | 4,321.5 ₹1,51,252.5 | 6,700 ₹2,34,500 | 5,500 ₹1,92,500 | 7,000 ₹2,45,000 | 9,000 ₹3,15,000 | 2,400 ₹84,000 Lowest | 7,000 ₹2,45,000 |
| 3.00 | M & L for Galvanised iron strip 25 x 4mm burried in ground or fixed on walls/floor with suitable saddles and screws beyond 7.5mtr of earth lead connecting with test point after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge. | 250 | RM | 46 ₹11,500 Lowest | 117.2 ₹29,300 | 115 ₹28,750 | 120 ₹30,000 | 70 ₹17,500 | 125 ₹31,250 | 95 ₹23,750 | 75 ₹18,750 |
| 4.00 | M & L for Galvanised iron strip 32 x 6 mm burried in ground or fixed on walls/floor with suitable saddles and screws beyond 7.5mtr of earth lead connecting with test point after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge. | 220 | RM | 162 ₹35,640 | 150 ₹33,000 | 145 ₹31,900 | 160 ₹35,200 | 140 ₹30,800 | 175 ₹38,500 | 120 ₹26,400 | 100 ₹22,000 Lowest |
| 5.00 | Supply & fixing of single core PVC insulated and unsheathed cable with aluminium conductor in and including heavy duty PVC conduiot fixed with screw on wall and using cable size 1x50 Sqmm 1100 Volt grade stranded aluminium conductor after taking out old, U/S earthing strip complete all as specified and as directed. | 210 | RM | 120 ₹25,200 | 107 ₹22,470 | 300 ₹63,000 | 350 ₹73,500 | 105 ₹22,050 Lowest | 800 ₹1,68,000 | 120 ₹25,200 | 500 ₹1,05,000 |
| 6.00 | Supply and fix Test point terminal block made of gunmetal /phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw fixed including taking down old one complete all as specified and as directed. | 59 | Each | 725 ₹42,775 | 449 ₹26,491 | 310 ₹18,290 Lowest | 500 ₹29,500 | 401 ₹23,659 | 1,500 ₹88,500 | 1,000 ₹59,000 | 800 ₹47,200 |
| 7.00 | Material & labour for chequered plate 5 mm thick size as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide primer and including taking down old one complete all as specified and directed by Engr-in-charge. | 2,100 | Kg | 120 ₹2,52,000 | 62 ₹1,30,200 Lowest | 107 ₹2,24,700 | 120 ₹2,52,000 | 90 ₹1,89,000 | 100 ₹2,10,000 | 90 ₹1,89,000 | 80 ₹1,68,000 |
| 8.00 | M&L for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint for climbing and light fitting post on steel tubular poles including taking down old one complete all as specified and as directed. | 3.5 | Per Qtl | 9,000 ₹31,500 | 7,767 ₹27,184.5 | 9,500 ₹33,250 | 10,000 ₹35,000 | 7,500 ₹26,250 | 14,000 ₹49,000 | 6,000 ₹21,000 Lowest | 8,000 ₹28,000 |
| 9.00 | M&L for earth pit of PCC M-15 Type B-1 in pit with XPM not elss than 4Kg per Sqm MS funnel with jali, and Earthpit with cover and making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation on earthpit to mach existing surfaces complete and testing on completion all as specified and directed by Engr-in-Charge. | 70 | Each Job | 600 ₹42,000 | 293 ₹20,510 Lowest | 450 ₹31,500 | 300 ₹21,000 | 300 ₹21,000 | 500 ₹35,000 | 750 ₹52,500 | 650 ₹45,500 |
| 10.00 | Supply & fix electrical Insulating mat confirming to IS15652/2006 (superceding IS: 5424-1969) B.I.S+CPRI+NTH+ERDA approved of C class of mats dielectric strength 65KV, sheet thickness not less than 3.0MM using at panel rooms including pasting of rubber mats with adhesive resin including taking down old one complete all as specified and directed by Engineer-in-Charge. | 70 | Sqm | 1,100 ₹77,000 | 879 ₹61,530 | 1,100 ₹77,000 | 800 ₹56,000 | 650 ₹45,500 | 1,000 ₹70,000 | 800 ₹56,000 | 300 ₹21,000 Lowest |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
14 Nov 2025, 6:00 pmClosed
GE NW NAVY NAGAR
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINTENANCE AND REPLACEMENT OF USERVICEABLE BUILDING EARTHINGS REPAIR OF EARTH PITS REPLACEMENT OF DAMAGED CABLE DUCT COVER AND OTHER ALLIED WORKS IN RS COLABA AT NAVY NAGAR COLABA, MUMBAI
2025_MES_736744_1
8553/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW NAVY NAGAR COLABA MUMBAI
CLASS D AND CATEGORY b(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR
₹70,000
20 Jan 2026
24 Oct 2025
17 Nov 2025
24 Oct 2025
14 Nov 2025
7 Nov 2025
24 Oct 2025 - 14 Nov 2025
Amount
Material & Labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6 mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion including taking down old one and making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks and removed surplus materials complete all as specified and directd. NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth wire upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing.
Material and labour for maintainance free environment friendly earth electrode set comprising of 17.2mm dia, 3 mtrs long rod of low carbon steel molecular copper bounded for a thickness of 250 micro OHMS, highly conductive ANSI/NSF STD-60 certified carbon bound backfill compound which shall set like concrete according to BS 7430 & IEEE 80 (each bag shall contain 50 lbs) after taking out old, U/S one complete all as directed by Engineer-in-Charge. Make- JEF Ecosafe or equivalent as approved by GE.
M & L for Galvanised iron strip 25 x 4mm burried in ground or fixed on walls/floor with suitable saddles and screws beyond 7.5mtr of earth lead connecting with test point after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge.
M & L for Galvanised iron strip 32 x 6 mm burried in ground or fixed on walls/floor with suitable saddles and screws beyond 7.5mtr of earth lead connecting with test point after taking out old/unserviceable one complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of single core PVC insulated and unsheathed cable with aluminium conductor in and including heavy duty PVC conduiot fixed with screw on wall and using cable size 1x50 Sqmm 1100 Volt grade stranded aluminium conductor after taking out old, U/S earthing strip complete all as specified and as directed.
Supply and fix Test point terminal block made of gunmetal /phosphorus bronze of size 75x75x25mm drilled and screwed including 3 Nos, 8mm dia 25mm long hex head screw fixed including taking down old one complete all as specified and as directed.
Material & labour for chequered plate 5 mm thick size as per site requirement including cutting to required shape and appling two coat of synthetic enamel paint over a coat of red oxide primer and including taking down old one complete all as specified and directed by Engr-in-charge.
M&L for Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint for climbing and light fitting post on steel tubular poles including taking down old one complete all as specified and as directed.
M&L for earth pit of PCC M-15 Type B-1 in pit with XPM not elss than 4Kg per Sqm MS funnel with jali, and Earthpit with cover and making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation on earthpit to mach existing surfaces complete and testing on completion all as specified and directed by Engr-in-Charge.
Supply & fix electrical Insulating mat confirming to IS15652/2006 (superceding IS: 5424-1969) B.I.S+CPRI+NTH+ERDA approved of C class of mats dielectric strength 65KV, sheet thickness not less than 3.0MM using at panel rooms including pasting of rubber mats with adhesive resin including taking down old one complete all as specified and directed by Engineer-in-Charge.
M & L for DLP trunking system of size 80x50mm fixing on wall with & including all accessories like cover, base joints, cover joints, flat angles, internal angles, external angles, partition etc including taking down old one Complete all as specified and directed.
M & L for DLP trunking system of size 150x50mm fixing on wall with & including all accessories like cover, base joints, cover joints, flat angles, internal angles, external angles, partition etc including taking down old one Complete all as specified and directed.
M&L and replacement for submain wiring with PVC insulated, PVC sheathed, armoured, FRLS 1100 V grade, 2 core 6 sqmm stranded copper conductor with GI wire 1 mm for earthing protection fixed on wall roof/duct complete and connecting from meter to DBs with glands including taking out existing damaged cables complete all as specified and directed.
Taking out old unserviceable and S & F MCB DB SPN confirming to IP 43-IK 09 with acrylic double door, 8 way complete with din rail, Neutral and Earthing bar grouted in wall complete all as specified and directed.
S&F MCB SPN, 32 Amp complete all as specified and directed by Engineer-in-Charge.
S & F MCB, single pole, 6 to 32 Amp, 10KA, 230Volt, “C” curve complete all as specified and directed.
Supply and fixing aviation light luminaire, LED type with integral LED aviation light comprising of aluminium housing with polycarbonate enclosure including taking down old one complete all as specified and directed.
Material and labour for supply and fixing of GI pipe medium grade 25mm dia 2m length including grouting in suitable PCC on roof for fixing the aviation light on top of the GI pipe with suitable fixing materials, clamps etc including taking down old one complete all as specified and as directed
Supply, Lay, Testing and commissioning XLPE insulated screened, PVC beded , armoured heavy duty electric cable, 1100 volts grade with stranded aluminium conductor of size 2 core 6 sq mm including taking down old one complete all as specified and directed.
S & F in replacement with Analog time switch 3P Module, 24 hours program, programmable every 15 min., backup of 100 hours, current capacity 16A for ON/OFF controlling of security lights complete all as directed.
S & F in replacement with power contactor 3 pole AC, with 240 volt coil, 32 Amp rating conforms to IS / IEC 60947-4-1 for ON/OFF controlling of security lights complete all as directed.
Supply and fixing of MCCB 160A, 25kA, 4P, Thermal magnetic release , Ics=100% Icu including taking down old one complete all as specified and directed.
Supply and fixing of MCCB upto 100A, 25kA, 4P, Thermal magnetic release , Ics=100% Icu including taking down old one complete all as specified and directed.
Genius Construction Co. (BID ID -3472307)
shubham construction (BID ID -3474415)
Shree Gajanan Enterprises (BID ID -3470552)
Sri Krishna Construction (BID ID -3469651)
OM SAI POWER SYSTEMS (BID ID -3474547)
S S ENTERPRISES (BID ID -3474407)
Shree Ayyappa Engineering (BID ID -3474624)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_824924.xls
BOQ • 1.34 MB
TENDERDOCUMENTS8553.pdf
Tender Documents • 0.82 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .