Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.3 LAdmitted-Finance 607 6TH FLOOR PRATEEK CENTRE SANJAY PLACE AGRA 282002 | AGRA | UTTAR PRADESH | 282002 | ₹38.3 L | L1 | Admitted-Finance |
| 2 | L2₹49.4 L+₹11.1 L (28.9%)Admitted-Finance 83 DEVI NAGAR NEW SANGANER ROAD JAIPUR 302019 | JAIPUR | JAIPUR | RAJASTHAN | 302019 | ₹49.4 L+₹11.1 L (28.9%) | L2 | Admitted-Finance |
| 3 | L3₹57.0 L+₹18.7 L (48.8%)Admitted-Finance | ₹57.0 L+₹18.7 L (48.8%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | INVENTIVE SOFTWARE SOLUTIONS PVT LTD L1 | Jyoti Engineering Works L3 | Suncity Urja Private Limited L2 |
|---|---|---|---|---|---|---|
| 1.00Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc. | ||||||
| 2.00 | High Tensile Steel | 30 | MT | 1,21,584 ₹1,43,469.12 Lowest | 1,28,000 ₹1,54,060.8 | 1,38,000 ₹1,64,468.4 |
| 3.00 | Mild Steel | 20 | MT | 1,18,654 ₹1,40,011.72 Lowest | 1,23,000 ₹1,48,042.8 | 1,30,500 ₹1,55,529.9 |
| 4.00 | Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. ) | 5.9 | MT | 1,30,000 ₹1,53,400 Lowest | 1,35,000 ₹1,62,486 | 1,50,000 ₹1,78,770 |
| 5.00Supply of Earthing material of Towers | ||||||
| 6.00 | Pipe Type Set | 8 | Set | 5,300 ₹6,254 | 3,000 ₹3,610.8 Lowest | 3,350 ₹3,991.94 |
| 8.00Supply of following Tower Accessories | ||||||
| 9.00 | Danger Plate | 8 | Nos. | 225 ₹265.5 Lowest | 300 ₹361.08 | 405 ₹482.62 |
| 10.00 | Number Plate | 8 | Nos. | 225 ₹265.5 Lowest | 300 ₹361.08 | 405 ₹482.62 |
| 11.00 | Phase Plate (Set of three) | 16 | Set | 345 ₹407.1 | 350 ₹421.26 | 315 ₹375.24 Lowest |
Tender Value
₹18.7 Cr
EMD Value
₹37.4 L
Closing Date
19 May 2025, 4:00 pmClosed
E(Contracts-1), RVPN, Jaipur
MM Building, Old Power House Premises, Bani Park,Jaipur-302006
Construction of transmission Lines associated with 220 kV GSS Bhanwata under BN-9018002503
2025_RRVPN_457128_1
RVPN/EHV/BN-9018002503
Open Tender
Electrical Works
Turn-key
450 days
Bhanwata Bandikui (Dausa)
Please refer Tender documents.
25 documents required · 25 mandatory
₹17,700
Please refer Tender documents.
₹37.4 L
SE(Contracts-1), RVPN, Jaipur
20 Jun 2025
9 Apr 2025
19 May 2025
9 Apr 2025
19 May 2025
22 Apr 2025
17 Apr 2025
Amount
Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
High Tensile Steel
Mild Steel
Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
Supply of Earthing material of Towers
Pipe Type Set
Supply of following Tower Accessories
Danger Plate
Number Plate
Phase Plate (Set of three)
Design, manufacture and supply of following line material. ***11/kv 70KN
(i) Disc Insulators
Design, manufacture and supply of following line material. ***11/kv 120KN
(i) Disc Insulators
Hardware Fittings for ACSR Zebra Conductor
Single Suspension H/W fittings for ACSR Zebra Conductor
Single Tension H/W fittings for ACSR Zebra Conductor
Accessories for ACSR Zebra Conductor
Mid Span Compression Joint for ACSR Zebra Conductor
Repair Sleeve for ACSR Zebra Conductor
Preformed Armour Rod for ACSR Zebra Conductor
Vibration Damper for ACSR Zebra Conductor
G.I. Earth Wire 7/3.15 MM
Accessories for Earth Wire
Strain Assembly for Earth Wire 7/3.15mm WITH COPPER Earth Bond
Suspension Assembly for Earth Wire 7/3.15mm
Vibration damper for Earth Wire 7/3.15mm
Mid span compression joint for Earth Wire 7/3.15mm
Repair sleeve for Earth Wire 7/3.15mm
Any Other item required for successful completion of work
Note: *** Bidder will quote either for Disc or Long Rod insualtors. In case of bidder quote for more than one types of insulators, then in evaluation highest cost of insulators will be considered.
Description of Work / Item(s)
Amount
Detail Survey as per tentative route- Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
Check survey as per approved route of line which includes- Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
(i) Any soil, soft rock other than hard rock
SETTING OF TEMPLATE & STUB/ANCHOR BOLT:- Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
(i) Tower including extension upto 9 Meter
CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
(i) 1:3:6 Mix (M-10)
(iii) 1:1.5:3 Mix (M-20)
STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
EARTHING:
(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
Erection of tower (with extension upto 9 Meters)
CONDUCTOR STRINGING: Stringing of ACSR Zebra including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
(i) Single Conductor
EARTHWIRE STRINGING: Stringing of galvanised steel standard wire including laying, jointing & tensioning, clamping, clipping and fixing vibration damper and earth bond etc.
One No. 7/3.15 mm galvanised wire
Revitment work
(A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix.
(B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering.
(C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc.
(D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate
DISMANTLING OF TOWERS:
Dismantling of super structure alongwith extensions having tack welded Bolts&nuts, including removing of Dshackles , hangers, U-Bolts , step bolts , ACD Danger plats number plate , phase plate of tower including transporation from site to our store and stacking of all material.
(a) 132KV and 220 KV S/C & D/C TOWERS
Destringing of Conductor :-
(a) Destringing of ACSR Panther conductor Dismanting of vibration damper s and armour rods removal of conductor from clamp and fitting in roliers , detensioning dehoisting of insulator string as reqired and collecting the material & depositing the same in our store and stacking .
(i) Single conductor
Restringing of Conductor :-
(a) Restringing of ACSR Panther conductor: Dismantling of vibration dampers and armour rods, fitting in rollers,de-tensioning, holding & lowering of conductor, de-hoisting of insulator string as required, adding/ removing and jointing of conductor, hoisting of insulator string, lifting of conductinto rollers and re-tensioning, jointing, fitting of armour rods and vibration dampers and clamping per route KM of the line section to be restrung dismantled material not re-used to be deposited in our stores & stacked.
(i) Single conductor
Any Other Item
Description of Work / Item(s)
Amount
Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
High Tensile Steel
Mild Steel
Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
Sub Station Structures All type
Supply of Earthing material of Towers
Pipe Type Set
Supply of following Tower Accessories
Danger Plate
Number Plate
Phase Plate (Set of three)
Design, manufacture and supply of following line material. ***11/kv 70KN
(i) Disc Insulators
Design, manufacture and supply of following line material. ***11/kv 120KN
(i) Disc Insulators
Hardware Fittings for ACSR Panther Conductor
Single Suspension H/W fittings for ACSR Panther Conductor
Single Tension H/W fittings for ACSR Panther Conductor
Double Tension H/W fittings for ACSR Panther Conductor
Accessories for ACSR Panther Conductor
Mid Span Compression Joint for ACSR Panther Conductor
Repair Sleeve for ACSR Panther Conductor
Preformed Armour Rod for ACSR Panther Conductor
Vibration Damper for ACSR Panther Conductor
OPGW Cable
48 Fibre (DWSM) OPGW fibre optic cable
Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box
Joint box (48Fibre)
FODP 48F: Indoor Type, rack mounted with FCPC coupling and pigtails
FODP 96F: Indoor Type, rack mounted with FCPC coupling and pigtails
Fiber Optic Approach Cable
48 Fibre (DWSM)
Installation Hardware set for above 48 Fibre, Fibre Optic Approach Cable
Post Insulator 145 KV
PI Clamp for Panther
Any Other item required for successful completion of work
Note: *** Bidder will quote either for Disc or Long Rod insualtors. In case of bidder quote for more than one types of insulators, then in evaluation highest cost of insulators will be considered.
Description of Work / Item(s)
Amount
Detail Survey as per tentative route- Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
Check survey as per approved route of line which includes- Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
(i) Any soil, soft rock other than hard rock
SETTING OF TEMPLATE & STUB/ANCHOR BOLT:- Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
(i) Tower including extension upto 9 Meter
CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
(i) 1:3:6 Mix (M-10)
(iii) 1:1.5:3 Mix (M-20)
STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
EARTHING:
(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
Erection of tower (with extension upto 9 Meters)
CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
(i) Single Conductor
OPGW cable & Accessories
Stringing of 48 Fiber (DWSM) OPGW FIBRE OPTIC CABLE
Installation Hardware set for above 48Fibre OPGW cabling including of al cable fittings and accessories exept joint Box
JOINT BOX (48 FIBER) OPGW CABLE
Revitment work
(A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix.
(B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering.
(C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc.
(D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate
FODP 48F: Indoor Type, rack mounted with FCPC coupling and pigtails
FODP 96F: Indoor Type, rack mounted with FCPC coupling and pigtails
48 Fibre (DWSM)
Installation Hardware set for above 48 Fibre, Fibre Optic Approach Cable
Re-stringing of 24 Fibre (DWSM) OPGW Fibre Optic cable, re-installation of hardware set for 24 fibre OPGW Fibre optic cabling including all cable fittings and accessories except joint box
DISMANTLING OF TOWERS:
Dismantling of super structure alongwith extensions having tack welded Bolts&nuts, including removing of Dshackles , hangers, U-Bolts , step bolts , ACD Danger plats number plate , phase plate of tower including transporation from site to our store and stacking of all material.
(a) 132KV and 220 KV S/C & D/C TOWERS
Destringing of Conductor :-
(a) Destringing of ACSR Panther conductor Dismanting of vibration damper s and armour rods removal of conductor from clamp and fitting in roliers , detensioning dehoisting of insulator string as reqired and collecting the material & depositing the same in our store and stacking .
(i) Single conductor
Restringing of Conductor :-
(a) Restringing of ACSR Panther conductor: Dismantling of vibration dampers and armour rods, fitting in rollers,de-tensioning, holding & lowering of conductor, de-hoisting of insulator string as required, adding/ removing and jointing of conductor, hoisting of insulator string, lifting of conductinto rollers and re-tensioning, jointing, fitting of armour rods and vibration dampers and clamping per route KM of the line section to be restrung dismantled material not re-used to be deposited in our stores & stacked.
(i) Single conductor
Erection of substation structures including leveling, setting of stub & Tighting, Punching of Nuts& Bolts and tack welding upto beam level as per specification.
Erection of Post insulator already erected structure including transportation of PIS , Nut and bolts , clamp and connectors , etc. from site store to location , febrication of base frame and assembly if required fixing of clamp etc
Any Other Item required for successful construction of line
Description of Work / Item(s)
Amount
Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
High Tensile Steel
Mild Steel
Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
Sub Station Structures All type
Supply of Earthing material of Towers
Pipe Type Set
Supply of following Tower Accessories
Danger Plate
Number Plate
Phase Plate (Set of three)
Design, manufacture and supply of following line material. ***11/kv 70KN
(i) Disc Insulators
Design, manufacture and supply of following line material. ***11/kv 120KN
(i) Disc Insulators
Hardware Fittings for ACSR Panther Conductor
Single Suspension H/W fittings for ACSR Panther Conductor
Single Tension H/W fittings for ACSR Panther Conductor
Double Suspension H/W fittings for ACSR Panther Conductor
Double Tension H/W fittings for ACSR Panther Conductor
Accessories for ACSR Panther Conductor
Mid Span Compression Joint for ACSR Panther Conductor
Repair Sleeve for ACSR Panther Conductor
Preformed Armour Rod for ACSR Panther Conductor
Vibration Damper for ACSR Panther Conductor
OPGW Cable
24 Fibre (DWSM) OPGW fibre optic cable
Installation Hardware set for 24 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box
Joint box (24Fibre)
Fiber Optic Approach Cable
24 Fibre (DWSM)
Installation Hardware set for above 24 Fibre, Fibre Optic Approach Cable
Post Insulator 145 KV
PI Clamp for Panther
Any Other item required for successful completion of work
Note: *** Bidder will quote either for Disc or Long Rod insualtors. In case of bidder quote for more than one types of insulators, then in evaluation highest cost of insulators will be considered.
Description of Work / Item(s)
Amount
Detail Survey as per tentative route- Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
Check survey as per approved route of line which includes- Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
(i) Any soil, soft rock other than hard rock
(ii) Hard Rock (with blasting subject to permission or without blasting)
SETTING OF TEMPLATE & STUB/ANCHOR BOLT:- Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
(i) Tower including extension upto 9 Meter
CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
(i) 1:3:6 Mix (M-10)
(iii) 1:1.5:3 Mix (M-20)
STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
EARTHING:
(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
Erection of tower (with extension upto 9 Meters)
CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
(i) Single Conductor
Revitment work
(A) Providing and laying cement concrete including curing, compaction etc. complete using stone aggregate 40 mm nominal size (crusher broken) in foundation plinth, using 1 Cement: 5 Sand: 10 aggregate mix.
(B) Random rubble stone masonary for rivetment in 1:5 cement sand mortar including providing and fixing 100mm dia PCC drain pipe & raised and cut-pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each deposited layer by ramming and watering.
(C) Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3 curing etc.
(D) Cement concrete coping grade 1:2:4 (1cement: 2coarse sand :4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete for 75mm thick with 20mm thick nominal size aggregate
Installation of OPGW
Stringing of 24 Fiber (DWSM) OPGW FIBRE OPTIC CABLE
Installation Hardware set for above 24 Fibre OPGW cabling including of al cable fittings and accessories exept joint Box
JOINT BOX (24 FIBER) OPGW CABLE
Fiber Optic Approach Cable
24 Fibre (DWSM)
Installation Hardware set for above 24 Fibre, Fibre Optic Approach Cable
Re-stringing of 24 Fibre (DWSM) OPGW Fibre Optic cable, re-installation of hardware set for 24 fibre OPGW Fibre optic cabling including all cable fittings and accessories except joint box
Erection of substation structures including leveling, setting of stub & Tighting, Punching of Nuts& Bolts and tack welding upto beam level as per specification.
Erection of Post insulator already erected structure including transportation of PIS , Nut and bolts , clamp and connectors , etc. from site store to location , febrication of base frame and assembly if required fixing of clamp etc
Any Other Item required for successful construction of line
Jyoti Engineering Works (BID ID -3169585)
Suncity Urja Private Limited (BID ID -3157972)
Suncity Urja Private Limited (BID ID -3157972)
Jyoti Engineering Works (BID ID -3169585)
Suncity Urja Private Limited (BID ID -3157972)
Jyoti Engineering Works (BID ID -3169585)
Suncity Urja Private Limited (BID ID -3157972)
Jyoti Engineering Works (BID ID -3169585)
Jyoti Engineering Works (BID ID -3169585)
Suncity Urja Private Limited (BID ID -3157972)
Suncity Urja Private Limited (BID ID -3157972)
Jyoti Engineering Works (BID ID -3169585)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.77 MB
Technical_Specs_Vol_II.pdf
Tender Documents • 1.09 MB
BOQ_820509.xls
BOQ • 0.52 MB
Vol-I_Commercial_Line_Final_rebid_approved.pdf
Tender Documents • 5.70 MB
Tenderdocument.pdf
Tender Documents • 1.09 MB
Tenderdocument_2.pdf
Tender Documents • 5.70 MB
BOQ.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .