Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC 2 8 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹32.6 L+₹4.1 L (14.4%)Rejected-Finance | L2 | Rejected-Finance BIDDER NOT LOWEST | |
| 3 | L3₹33.9 L+₹5.4 L (18.9%)Rejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | L3 | Rejected-Finance BIDDER NOT LOWEST | |
| 4 | L4₹36.8 L+₹8.3 L (29.1%)Rejected-Finance | L4 | Rejected-Finance BIDDER NOT LOWEST | |
| 5 | L5₹37.6 L+₹9.1 L (32.0%)Rejected-Finance | L5 | Rejected-Finance BIDDER NOT LOWEST |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
31 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST DELHI CANTT 10
GE WEST DELHI CANTT 10
REPAIR REPLACEMENT OF INTERNAL FITTING FIXTURES TO SALARIA OFFRS ENCLAVE PIRU VIHAR CARIAPPA AND MT LINE UNDER AGE EM WEST OF GE WEST DELHI CANTT 10
2020_MES_336363_1
GE/DW-10/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE WEST DELHI CANTT
₹96,000
3 Dec 2020
28 Jul 2020
2 Sept 2020
28 Jul 2020
31 Aug 2020
17 Aug 2020
60 days
Amount
Taking down carefully old unserviceable, avaition obstruction light,cable from height of 35 mtr to panel room including all accessories complete all as specified and directed.
S&F submain wiring for avaintion abstruction light alongwith earth wire with 2 run of 10 Sqmm and one run of 10 Sqmm as earth wire of PVC insulated copper conductor, sinle core cable including rigid PVC conduit of size 25 mm dia on surface of walls with all fittings accessories complete all as specified and directed.
M&L Aviation obstruction light with die cast aluminium housing faceted anodised reflector heat resistant clear thick glass and accessories with LED lights as per Cat No BGAV 302 LED of Bajaj or equivalent in Philips/ Crompton/ Wipro.
M&L Aluminium termination , single pointed aluminium rod 12 mm dia and 300 mm long for lightning arrestor complete all as specified and directed.
M & L Alluminium strip 25 x 3 mm as earth lead for extension from termition rod though the length of building to earth test point including porcelin insulators all fitting fixtures by nut bolts,all as specified and directed.
M&L for earthing with galvanized steel earth plate 60cm X 60cm X 6 mm thick, buried directly in ground(earth pit not less than 2.25 mtr deep below ground level) with the top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanized earth strip 30 mm x 6 mm thick by means of bolts, nuts, check nuts and washers of galvanized iron or steel an d earth plate surrounded by packed layers of coal dust and common salt 15 cm thick all around top and bottom all as shown in electrical plate No 5 connected to panel/equipment all as directed including PCC (1: 3:6) type C1 earth pit, cast iron pit cover, funnel with wire mesh,watering pipe 20mm dia light grade grade,1.5mtr long and 15mm bore light grade from earth plate to pole upto the height of 3mtr as protection pipe fixed with 40x3mm flat iron clamps and GI strip connected to on OHL and testing on completion including excavation earth work and disposal of surplus soils,set of two earthing commonly will be jointed.by nut bolts,including test point terminal block made of gunmetal or phosphorus bronze size 75 x 75 x 25 mm complete all as specified and directed.
Supply and Laying XLPE insulated armoured cable Heavy duty with alluminium conductor 1100 volts grade cross sectional area 10 sqmm 2 core laying through the length of the tank to juction box complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light/fan socket or power) complete including fittings such as switches, ceiling roses, pendents, regulators, sockets light fittings etc including making good the disturbed area with existing surface etc complete all as specified directed
M&L for point wiring with stranded copper conductor FRLS 1.50 Sqmm size nominal area PVC insulated unsheathed cable 1100 volts grade conforming to IS:694 drawn in and exisiting concealed PVC rigid conduit as directed and replacement of GI boxes of reqd sizes to accomodate modular switches/sockets as per site requiremnt and including single core stranded copper conductor 1.5 Sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit complete all as specified and directed for the following :-
(a) One light/fan point controlled by one way switch 5 amps.
(b) One bell / buzzer point controlled by one bell push
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(d) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
All as per item No. 9.01 here in before but with 2 x 2.5 Sqmm and 1x 2.5 sqmm cable for earth connection for one 3 pin socket outlet 15 amps independent board complete all as specified and directed
S&F in repair of switch modular 6 Amps 230 Volts one way etc complete all as specified and directed.
S&F in repair of switch modular 6 Amps 230 Volts one way suitable for SSK cover plate complete all as specified and directed.
S&F in repair of switch modular 16 Amp 230 Volts etc complete all as specified and directed.
S&F in repair ofswitch modular 16 Amp 230 Volts suitable for SSK cover plate etc complete all as specified and directed.
S&F in repair of socket modular 5 pin 6 amps etc complete all as specified and directed.
S&F in repair of socket modular 5 pin 6 amps suitable for SSK cover plate etc complete all as specified and directed.
S&F in repair of universal socket modular 2 in 1, 3 pin, 5 and 16 amps etc complete all as specified and directed.
S&F in repair of universal socket modular 2 in 1, 3 pin, 5 and 16 amps suitable for SSK cover plate etc complete all as specified and directed.
S&F in repair 5 amps single pole one way switch flush button type complete all as specified and directed.
S&F in repair 15 amps single pole one way switch flush button type complete all as specified and directed.
S&F in repair of switch modular 6A bell push suitable for SSK cover plate etc complete all as specified and directed.
S&F in repair of switch modular 6A bell push etc complete all as specified and directed.
S&F in repair 2/3 pin 5 amps socket outlet multipurpose complete all as specified and directed.
S&F in repair socket outlet multipurpose 2 in 1, 5 and 15 Amps suitable for SSK cover plate complete all as specified and directed.
S&F in repair 8 modular cover plate of SSK complete all as specified and directed.
S&F in repair 6 Modular cover plate complete all as specified and directed.
S&F in repair of ceiling fan regulator support modular type suitable for SSK etc complete all as specified and directed.
S&F in repair of ceiling fan regulator support modular type etc complete all as specified and directed.
S&F in repair of Electric bell Ding-Dong AC 230 Volt etc ccomplete all as specified and directed.
S&F in repair of Decorative wall mounting light fitting Made up of high grade CRCA steel sheet, epoxy powder coated white after phosphochromate treatment.B22 lamp holder in engineering plastic grade provided as standard. 15W Beetle
Supply and fix 15 Amps plug top 230Volt,50 Hz, watt complete all as specified and directed.
Supplying, installation, testing and commissioning of 600mm (NS) IP-20 9-10W LED Surface Mounted LED integrated batten fitting. The minimum Lumen output should be 1000≥lm with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.90, CRI (Ra)>80, THD <20%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram. Make : WIPRO: LL20-111-XXX-65-NE3/ HAVELLS: ENDURALINEARNEOBS10WLED865SPCWH / PHILIPS: BN 021 LED10S- 6500 PSU GR S1 / OSRAM: LEDCOMFO Batten G3 0910 827 Osram.(WIPRO Cat Ref: LL20-111-XXX-65-NE3
Supply & fixing single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828 of 1996, IEC 60898 of 2002 including taking down old MCB's complete all as specified and directed.
S&F in repair Double pole MCB 63 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity and terminal box suitable upto 63 sqmm cable complete conforming to IS 8828 of 1996 all as specified
S&F in repair double pole MCB 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity and terminal box suitable upto 63 sqmm cable complete conforming to IS 8828 of 1996 all as specified
Supply and Fixing in repairs MCB TPN 63 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828 of 1996, IEC 60898 of 2002 complete all as specified and directed.
Supply and Fixing in repairs MCCB four pole, 63 Amp with sheet metal enclosure ultimate breaking capacity 16 KA ith adjustable thermal/electronic release for overload raning from 70% to 100% of the rated current and fixed magnetic release for short circuit and under voltage release complete conforming to IEC -60947-2 and IS: 13947-3 complete all as specified.
Supply and fixing in repairs MCCB four pole, 100 Amp with sheet metal enclosure ultimate breaking capacity 16 KA ith adjustable thermal/electronic release for overload raning from 70% to 100% of the rated current and fixed magnetic release for short circuit and under voltage release complete conforming to IEC -60947-2 and IS: 13947-3 complete all as specified.
Supply and Fixing in repairs MCCB TP 160 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 16 KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828 of 1996, IEC 60898 of 2002 complete all as specified and directed. (Make/Model : Cat part No.IHLGST0160# of Havells or equivalent in schinder(Multi9)/Hager
Supply and Fixing in repairs MCCB 4P 250 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 16 KA breaking capacity and terminal box suitable upto 35 sqmm cable complete conforming to IS 8828 of 1996, IEC 60898 of 2002 complete all as specified and directed. (Make/Model : Cat part No.IHLGST0160# of Havells or equivalent in schinder(Multi9)/Hager
S & F in repair Building security light 45 watt ENDURA PEARL NEO New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07.
Taking down sub main wiring off sizes etc complete all as specified and directed.
S&F submain wiring alongwith earth wire with 2 run of 10 Sqmm (Main Cable and neutral) and one run of 10 Sqmm as earth wire of FR PVC insulated copper conductor, single core cable including rigid PVC conduit of size 25 mm dia with all fittings accessories in concealed complete all as specified and directed.
S&F submain wiring alongwith earth wire with 2 run of 6 Sqmm(Main Cable and neutral)stranded copper conductor FR PVC insulated unsheathed cable conforming to IS:694 drwan and one run of 6 Sqmm as earth wire of FRLS PVC insulated copper conductor, single core cable in drawn through and exisiting concealed PVC rigid conduit complete all as specified and directed.
M&L for rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) with appropriate gauge and quantity, both sides of rewinding covered with high quality varnish complete including painting, replacement of minor items such as namda and provisions of new nuts and pins for 1200/1400 mm sweep including taking down and refixing the same all as specified and directed by Engr-in-Charge
All as per item No 45 above but for exhaust fans 300/450mm sweep.
M&L in repairs fan condenser 2.5/3.15 mfd complete all as specified and directed. Make - Usha , Bajaj or equivalent .
Supply and fix in repair of replacement of copper flange assembly of any type and make for water heater of 25/35/50 ltr capacity complete all as specified and directed.
S&F in repair copper heating element 1500 watt embedded copper, sheathed tubular with theremostat casing cap triangular type of IS : 4159 complete all as specified and directed.
S&F in repair thermostat suitable to work water temperature 30o to 75o C electric cut up for any type of water heater reqd at site complete all as specified and directed.
S&F in repair PVC connection 600 mm long with nut bolt washer reqd for water heater off sizes complete all as specified and directed.
S&F in repair flush/surface mounted neon indicator lamps in colours red or green as per site requirement complete all as specified and directed.
S&F in repair of inner shell of steel body suitable for following capacity of geyser as given below specified and directed as per existing pattern complete all as specified and directed.
(a) 25 Ltrs
(b) 50 Ltrs
S&F in repair of inner shell of copper body suitable for following capacity of 25Ltr geyser specified and directed as per existing pattern complete all as specified and directed.
S&F in repair metal clad plugs 2 pole including rating 20 amps 250volt complete all as specified and directed.
S&F in repair metal clad sockets 2 pole including earth rating 20 amps 250 volt complete all as specified and directed.
Supplying, installation, testing and commissioning of 1200mm (NS) IP-20 18-22W LED Surface Mounted LED integrated batten fitting. The minimum Lumen output should be 2000≥lm with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.90, CRI (Ra)>80, THD <20%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram. Make : HAVELLS: ENDURALINEAR NEOBS22WLED865SPCWH/ PHILIPS: BN 021 LED25S 6500 PSU GR S1 / WIPRO: LL20-221-XXX-65-NE3/ OSRAM: LUXPOWER BATTEN 19WL 865.
S&F in repair Pressed steel sunken terminal boxes of Size 3"x 4" including Taking Down from the wall after replacing sunken box good making finshing wall with existing colour cement base paint applied two coats all as specified and directed.
S&F in repair Pressed steel sunken terminal boxes of Size 4"x 6" including Taking Down from the wall after replacing sunken box good making finshing wall with existing colour cement base paint applied two coats all as specified and directed.
S&F in repair outer shell with collar made out of PVC suitable for geyser of capacity 25 Ltr complete all as specified and directed.
S&F in repair batten holder insulated body 2 pin 230 volt complete all as specified and directed.
Supply & fix in repair 10 W LED, surface mounted , decorative oval bulk head edge-lit LED luminarie comprising of high brightness LED luminaire with lumen output to be fitted with colour temperature 6000K, power factor > 0.95, CRI > 70, Beam single > 240, IP Protection 20 or higher suitable to work on 90-300 volt AC, confirming technical specification complete all as specified and directed.
Supply and Fixing in repairs 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz complete all as specified and directed.
Supply and Fixing in repairs 7 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) in repair with top edge of the plate not less than 1.5 meter normal ground level, connected to galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel besides welding at all joints all as shown in electrical plate no 3 of SSR Part I including excavation and earth work, GI pipe light grad 25 mm bore for protection of earth strip from earth electrode & GI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate no 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified and directed.
Supply and Fixing in repairs LED Ultra bright glass LED Tube rod for fitting with very high efficiancy suitable for installation in existing fitting 4 ft length complete all as specified and directed.
Deduct Credit: for demolished/dismantled material of (-) Rs 556680.00 (Minus) as listed in Schedule 'A' Part II (Credit Schedule) Note: Tenderer's shall not quote against this item. The amount of Credit Schedule is tentative, however the same shall be considered to arrive at the contract sum
M/S.Bhupinder Trading Company
M/s Adhikari construction co.
M/s S.G. BUILDERS
S.R. Constructions
M/S ANIL KUMAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .