| 1 | | Design, manufacture, assembly, supply, installation, testing, delivery and commissioning of 10 KVA UPS of Continuous rating, inbuilt SNMP for online monitoring, double conversion mode 3 ph input and 1 ph output UPS system with IGBT rectifier. The UPS Cabinet shall consist of a Breaker and breaker cabinet, rectifier / charger, a three-phase inverter, static transfer switch, logic, synchronizing equipment, protective devices, display module shall show clear graphical / text based overview of alarms, status data and instructional help, Front/ Back cable entry provision, Parallel kit with necessary BMS compatibility (Hardware and software items for third party integration) with MODBUS protocol-RS 485 and accessories as required for proper operation. NOTE The model shall be suitable for parallel redundant and including total 05 years onsite warranty | 1 | Nos | [email protected] | 365 |
| 2 | | Supply, installation, testing and commissioning of Battery banks of requisite quantity and 12V, 42 AH rating suitable for 10kVA (Continuous rating) online UPS system with one suitably rated DC circuit breaker with all necessary interconnecting links/wiring for each of above UPS units with autonomy to 30 minutes at the end of Battery life span at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks, Battery Rack and base frame shall be designed to cater a point load to be conformed by vendor. Minimum VAH required - 10080 | 20 | Set | [email protected] | 365 |
| 3 | | Supply and Laying of 1100V grade multistrand, copper conductor, Uni Nyvin, unarmoured flexible cable of requisite size for interconnection between battery, battery breakers and the respective 10KVA UPS Units including incomer cable of raw power to UPS. . The cable shall conform to IS-694. | 70 | Mtr | [email protected] | 365 |
| 4 | | Supply,Fixing and commissioning of cable termination with Single compression cable gland, Ring type copper lugs and necessary steel bolts for interconnection between battery, battery breakers and Cable ties for the respective 10 KVA UPS Units as required for site All Complete Job . | 1 | Lot | [email protected] | 365 |
| 5 | Supply and Installation of Battery open cabinet or Rack | Supply and installation of Open Battery Rack suitable for the Battery bank for 10 kVA UPS system as per point 2 item including UPS mounting | 1 | Set | [email protected] | 365 |
| 6 | | Charges for Installation and Commissioning of the whole system including the charges for providing proper training to the Electrician of the Site/Hospital | 1 | Lot | [email protected] | 365 |
| 7 | | Supplying and fixing TP sheet steel enclosure on surface/ recess with 40/ 63 A FP MCB complete with connections, testing and commissioning etc. as required. | 1 | Nos | [email protected] | 365 |
| 8 | | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12 way, Double door | 1 | Nos | [email protected] | 365 |
| 9 | | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire | 250 | Mtr | [email protected] | 365 |
| 10 | | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 140 | Mtr | [email protected] | 365 |