Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 LAccepted-AOC | ₹3.3 L | L1 | Accepted-AOC LESS |
| 2 | L2₹3.3 L+₹251.99 (0.08%)Rejected-AOC | ₹3.3 L+₹251.99 (0.08%) | L2 | Rejected-AOC ABOVE |
| Sl No | Description | Qty | Unit | M.S.& CO L2 | GKENGINEERING AND DEVELOPMENTS L1 |
|---|---|---|---|---|---|
| 1.00 | Dismantling the damaged RCC as per directed by the departmental officers CCMC SOR-25-26 Pg.no-3 | 1 | Cu.m | 5,072 ₹5,072 | 5,071 ₹5,071 Lowest |
| 2.00 | Dismantling the damaged Plain cement concrete as per directed by the departmental officers CCMC SOR-25-26 Pg.no-3 | 1 | Cu.m | 573 ₹573 | 572 ₹572 Lowest |
| 3.00 | Dismantling the damaged brick work as per directed by the departmental officers CCMC SOR-25-26 Pg.no-3 | 1 | Cu.m | 334 ₹333.33 | 333 ₹332.33 Lowest |
| 4.00 | Earth work excavation for foundation in ordinary soil, light black cotton sandy loam and dry silt including shoring, strutting, baling or pumping out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15cm thick and depositing the surplus earth at places as directed by the departmental officers with initial lead and lift - 10 m3 CCMC SOR-25-26 Pg.no-3 | 1 | Cu.m | 221 ₹221 | 220 ₹220 Lowest |
| 5.00 | Conveyance of excavated earth and clearing away from site to a lead of 2KM from site etc., complete CCMC SOR-25-26 Pg.no-3 | 3 | Cu.m | 105 ₹314.79 | 103 ₹308.79 Lowest |
| 6.00 | Plain Cement Concrete1:4:8 (one part of cement, four part of Crushed Stone Sand (M-Sand) and Eight part of coarse aggregates ) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification CCMC SOR-25-26 Pg.no-4 | 1 | Cu.m | 5,963 ₹5,963 | 5,962 ₹5,962 Lowest |
| 7.00 | Plain Cement Concrete1:2:4 (one cement, two Crushed Stone Sand (M Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification CCMC SOR-25-26 Pg.no-4 | 1 | Cu.m | 7,267 ₹7,267 | 7,266 ₹7,266 Lowest |
| 8.00 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc., including strutting 3 m high using mild steel sheets of size 90 cm X 60 cm X and B.G10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size10cm X 6.5cm (spacedat about 90 cmc/c)and supported dycasur in a props of 10 cm to13 cm dia (spacedof75cmC/C)complying with standard specification and directed- 10 m 2 (P & D) Data 38 CCMC SOR-25-26 Pg.no-5 | 5 | Sq.m | 1,182 ₹5,910 | 1,181 ₹5,905 Lowest |
| 9.00 | Suppling and fabricating and placing in position MS (or)R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. CCMC SOR-25-26 Pg.no-8 | 1 | Qtl | 9,543 ₹9,543 | 9,542 ₹9,542 Lowest |
| 10.00 | Reinforced Cement concrete 1:1.5:3 (one cement,one and half M.sand & three course aggregate) using 20 mm gauge hand broken/and broken granite stone for all RCC items of works excluding centerings huttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherever necessary as directed by departmental officer etc., complete. CCMC SOR-25-26 Pg.no-5 | 0.99 | Cu.m | 9,745 ₹9,696.27 | 9,744 ₹9,695.28 Lowest |
Tender Value
₹4 L
EMD Value
₹4,000
Closing Date
19 Dec 2025, 3:00 pmClosed
Assistant Commissioner
Coimbatore Corporation, Central zone, Hosur road, Coimbatore.641018
Repair works to the pattakara ayyasamy kovil street corporation public toilet in ward no 81 central zone
2025_MAWS_631177_49
E6/2025-26/CZ
Open Tender
Civil Works
Works
Central zone
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹4,000
Yes
13 Jul 2026
12 Dec 2025
19 Dec 2025
12 Dec 2025
19 Dec 2025
12 Dec 2025
Dismantling the damaged RCC as per directed by the departmental officers CCMC SOR-25-26 Pg.no-3
Dismantling the damaged Plain cement concrete as per directed by the departmental officers CCMC SOR-25-26 Pg.no-3
Dismantling the damaged brick work as per directed by the departmental officers CCMC SOR-25-26 Pg.no-3
Earth work excavation for foundation in ordinary soil, light black cotton sandy loam and dry silt including shoring, strutting, baling or pumping out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15cm thick and depositing the surplus earth at places as directed by the departmental officers with initial lead and lift - 10 m3 CCMC SOR-25-26 Pg.no-3
Conveyance of excavated earth and clearing away from site to a lead of 2KM from site etc., complete CCMC SOR-25-26 Pg.no-3
Plain Cement Concrete1:4:8 (one part of cement, four part of Crushed Stone Sand (M-Sand) and Eight part of coarse aggregates ) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification CCMC SOR-25-26 Pg.no-4
Plain Cement Concrete1:2:4 (one cement, two Crushed Stone Sand (M Sand) and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification CCMC SOR-25-26 Pg.no-4
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc., including strutting 3 m high using mild steel sheets of size 90 cm X 60 cm X and B.G10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size10cm X 6.5cm (spacedat about 90 cmc/c)and supported dycasur in a props of 10 cm to13 cm dia (spacedof75cmC/C)complying with standard specification and directed- 10 m 2 (P & D) Data 38 CCMC SOR-25-26 Pg.no-5
Suppling and fabricating and placing in position MS (or)R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors. CCMC SOR-25-26 Pg.no-8
Reinforced Cement concrete 1:1.5:3 (one cement,one and half M.sand & three course aggregate) using 20 mm gauge hand broken/and broken granite stone for all RCC items of works excluding centerings huttering and cost of reinforcement but including curing etc.,complete and also including fixing fan clamps and fixtures in rcc works wherever necessary as directed by departmental officer etc., complete. CCMC SOR-25-26 Pg.no-5
Brick work in cement mortar 1:5 mix using Fly Ash bricks of 230 x 110 x 70 mm (83/4"x41/4"x23/4") including cost of materials and labour charges etc., as per standard specification - 1m3 CCMC SOR-25-26 Pg.no-9
Plastering with cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P-Sand)),10 mm thick in all floors including cost and conveyance of all materilas to site and labour chargesetc,completeas per standard specifications CCMC SOR-25-26 Pg.no-9
Plastering with cement mortar 1:5(One part of Cement and Five part of Plastering Sand (P-Sand))12mm in all floors including cost and conveyance of all materilas to site and labour chargesetc,completeas per standard specifications CCMC SOR-25-26 Pg.no-9
Paving the floor with design Antiskirt ceramic tiles (colour and shadeas directed)of size 305 mm x 305 mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P-Sand)), 20 mm thick laid in-situ and pointed with same coloured cement CCMC SOR-25-26 Pg.no-11
Dadooing walls with ceramic tiles of sizes 300 mm X 450 mm X 8 mm size of approved make and quality and colour Set in cement mortar 1:2 (One part of Cement and two part of Plastering Sand (P-Sand)) over 10 mm base layer plastering and pointing with white cement neatly as directed. (Sl.No.360f) CCMC SOR-25-26 Pg.no-11
Weathering Course with Concrete Broken Brick (S.I.No.278) & (P&D) Data 54.Jelly 20mm gauge in pure slaked lime (nosand tobeadded) over roof slab,the proportion of brick jelly to lime being '32 to12.5 well beated with wood enbeaters forgiving required slope and thicknessas directed by the departmental officers etc., complete.-10 cum CCMC SOR-25-26 Pg.no-10
Painting two coats for Interior surfacewith approved Interior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc completeand including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. (Sl.No.394) CCMC SOR-25-26 Pg.no-12
Painting two coats for Exterior surfacewith approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc completeand including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. (Sl.No.404) CCMC SOR-25-26 Pg.no-12
Manufacturing supplying and fixing of MILD STEEL DOOR made out of 50 x 50 x 6 mm M.S angle for outer frame, 35 X 35 X 5 mm M.S.Angle for outer frame of shutter. The entire shutter are as hall be covered with CRC sheets (18G) with 5 Nos, of stiffners using M.S.Flats of size 25 X 6 mm at equal intervals horizontally. The corners of the frames and shutter with CRC sheets shall be welded by adopting flash but tweldin go rany other suitable method. Provision towards 3Nos, of Hinges incase of single shutters / 6Nos,of Hinges incase of Double shutters of 125X31X1.25 mm size placed at appropriate intervals and provisions shall be made for Tower bolts 2Nos, Aldrop1No. The frame shall be providedwith 6 Nos, of Hold fast of 200 mm length using 50 X 6 mm M.S.Flat.Theentire frame and shutter shall be provided with one coat of red oxide primer including cost of hold fasts,hinges, locking arrangements, handles wind appliences etc., complete and as directed by the departemental officers. . CCMC SOR-25-26 Pg.no-14
Supplying and fixing in position Indian water closet of size 580 X 440 mm, white glazed earthenware of approved quality with 'P' trapor 'S' trap confirming to IS :2556- Part XII with sand cushion and forming flooring alround the closet using 40 mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly)100 mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes / PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slabandmaking good the disturbedportion tooriginal conditionwithout leakage etc., complete complying with standard specification sand as directed by the departmental officers. CCMC SOR-25-26 Pg.no-15
Wiringwith2x1.5 sq.mm. PVC insulated single coreunsheathedFRLScopper conductor cableof 1100Vgrade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with MS switch Box and 5 A FT switch with painting of suitable colour continuous earth wire connection of 1.5 sq.mm copper wire for lightpoint / fanpoint (for electronic regulator) Electrical SOR-25-26 Pg. no-02
Supply and fixing of 4 Feet LED18W Fitting with LED18W tube(LowerEnd)complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. Electrical SOR-25-26 Pg.no-191
Supply and fixing of WT bulk head fitting with guard suitable for 15 W LED Bulb as directed by the departmental officers. Electrical SOR-25-26 Pg.no-40
Add :- GST @ 18%
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_755659.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .