| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹51,350Qualified Make: NUMERIC
Model: Numeric CHANDIGARH CHANDIGARH 160030 | CHANDIGARH | CHANDIGARH | 160030 | Make: NUMERIC
Model: Numeric | L2 | Qualified | |
| 2 | L3₹53,170Qualified Make: BPE
Model: BPE NIY LI 1.0KVA 216VAH 1YR NA AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE NIY LI 1.0KVA 216VAH 1YR NA | L3 | Qualified | |
| 3 | L4₹53,300Qualified Make: zebronic
Model: ZEBRONICS ZEB-U1000 PLUS 2 RANA SAMAY SINGH DURG MAHARANA PRATAPGARH KAKROLA VILLAGE SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | Make: zebronic
Model: ZEBRONICS ZEB-U1000 PLUS | L4 | Qualified | |
| 4 | L4₹53,300Qualified Make: MICRO POWER
Model: MPT S W- 1.0/216 KALI MANDIR ROAD GHAZIABAD UTTAR PRADESH 201010 | GHAZIABAD | UTTAR PRADESH | 201010 | Make: MICRO POWER
Model: MPT S W- 1.0/216 | L4 | Qualified | |
| 5 | L5₹54,418Qualified Make: microtek
Model: Microtek UPS Twin Guard Pro+ 1000VA 1 B VASHISHT NAGER BABYAL ROAD NEAR HARYANA GRAMIN BANK AMBALA CANTT AMBALA HARYANA 133001 INDIA | AMBALA | HARYANA | 133001 | Make: microtek
Model: Microtek UPS Twin Guard Pro+ 1000VA | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
2 Jul 2018, 10:00 amClosed
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 13 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 0.5/84
0.5/168
0.5/400
0.65/168
0.65/400
0.65 108
0.8/168
0.8/400
0. 8/216
1.0/168
1.0/400
1.0/216
1.0/800
1.5/80 0
1.5/600
2.0/800
2.0/1 600 Technology MOSFET-PWM MOSFET-PWM
IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single phase sinewave 230v AC
50Hz Single phase sinewave 230v AC
50Hz
Single Phase Quasi-Sin-wave 230 V AC
50 Hz Degree of protection IP-21 IP-21
IP 20 Inverter Efficiency (%) >/= 70% >/= 60%
>/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year
2 Years
5 Years Installation and commissioning No - 1/4 instructions CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through inverter) No Yes
No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin
3 Three pin
Hard wiring
Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND Damp heat Test at 45 Yes - 2/4 CERTIFICATIONS degree
RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 41016861 19.10.2015 - Name Of Lab BIS - Address of Lab BIS
Manak Bhawan
9
Bahadur Shah Jafar Marg
New Delhi-110022 - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Parthiban Arumugam 744102
Communication Centre HQANC C/o Navy Office Port Blair- 744102 13 45 EMD Required No ePBG Required No
249302
GEM/2018/B/35445
Line Intractive UPS with AVR
45 days
Andaman And Nicobar Islands; South Andamans
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Line Intractive UPS With AVR ( 13 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 0.5/84 | - | - | - |
| 0.5/168 | - | - | - |
| 0.5/400 | - | - | - |
| 0.65/168 | - | - | - |
| 0.65/400 | - | - | - |
| 0.65 108 | - | - | - |
| 0.8/168 | - | - | - |
| 0.8/400 | - | - | - |
| 0. 8/216 | - | - | - |
| 1.0/168 | - | - | - |
| 1.0/400 | - | - | - |
| 1.0/216 | - | - | - |
| 1.0/800 | - | - | - |
| 1.5/80 0 | - | - | - |
| 1.5/600 | - | - | - |
| 2.0/800 | - | - | - |
| 2.0/1 600 Technology MOSFET-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single phase sinewave 230v AC | - | - | - |
| 50Hz Single phase sinewave 230v AC | - | - | - |
| 50Hz | - | - | - |
| Single Phase Quasi-Sin-wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP-21 IP-21 | - | - | - |
| IP 20 Inverter Efficiency (%) >/= 70% >/= 60% | - | - | - |
| >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year | - | - | - |
| 2 Years | - | - | - |
| 5 Years Installation and commissioning No - 1/4 instructions CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through inverter) No Yes | - | - | - |
| No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin | - | - | - |
| 3 Three pin | - | - | - |
| Hard wiring | - | - | - |
| Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND Damp heat Test at 45 Yes - 2/4 CERTIFICATIONS degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 41016861 19.10.2015 - Name Of Lab BIS - Address of Lab BIS | - | - | - |
| Manak Bhawan | - | - | - |
| 9 | - | - | - |
| Bahadur Shah Jafar Marg | - | - | - |
| New Delhi-110022 - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Parthiban Arumugam 744102 | - | - | - |
| Communication Centre HQANC C/o Navy Office Port Blair- 744102 13 45 EMD Required No ePBG Required No | - | - | - |
Exempted
2 Jul 2018
25 Jun 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_249302.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .