Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 CrAccepted-AOC DHANI CHANDPUR BAWAL ROAD REWARI DHANI CHANDPUR BAWAL ROAD REWARI 123401 | REWARI | REWARI | HARYANA | 123401 | ₹19.5 Cr | L1 | Accepted-AOC Alloted |
| 2 | L2₹21.3 CrRejected-AOC 14 CHAHAR CONSTRUCTION CO ADARSH NAGAR NEAR ROHILLA COMMUNICATION 124103 | JHAJJAR | HARYANA | 124103 | ₹21.3 Cr | L2 | Rejected-AOC Rejected |
Tender Value
₹16.9 Cr
EMD Value
₹33.8 L
Closing Date
10 Jan 2024, 10:00 amClosed
RAVINDER
EE PHE Division Bawal
Construction of additional Tank Construction of additional Tank
2023_HRY_338069_1
2023F851FADA 8F05 4239 AE2D 830B6F739984580PUH
Open Tender
Civil Works
1320 days
BAWANA GUJAR CHITA DUNGRA GOTHARA TAPPA KHORI G
As per approved DNIT OR CBD
3 documents required · 3 mandatory
₹20,000
₹33.8 L
Yes
18 Jun 2024
20 Dec 2023
10 Jan 2024
20 Dec 2023
10 Jan 2024
20 Dec 2023
20 Dec 2023 - 10 Jan 2024
Amount
Providing Fixing Led light of 50watt (Syska, Havells, Philips make)
Providing Fixing Led light of 9watt (Syska, Havells, Philips make)
wall fan of size Sweep 40 cm (400 mm) Speed 1280 rpm Power Input 55 W
Supply erection, and commissioning electric operated dewatering pump of 3 HP Kirlosker make complete from priming with wiring starters switches etc. also the required GI pipe (B Class) valves and sight glass etc. complete.
Supply erection, and commissioning electric operated Vaccume Pump of 2 HP Kirlosker make complete from priming with wiring starters switches etc. also the required GI pipe (B Class) valves and sight glass etc. complete.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length fixed on existing angle iron ‘Y’ shaped placed 2.4 m or 3.00 m apart with 5 horizontal R.B.T. reinforced barbed wire, studtied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.)
Supply erection testing and commissioning of Flow Meter (KROHNE Make) with digital display at desired place in Pump Chamber of 100 to 400 mm i/d complete in all respect.
Providing and fixing pressure guage 6` dia 0-24 kg/sqcm as per site required complet in all respect
HT METERING PANEL Supply erection testing and commissioning of HT metering panel 11 KV consisting of one no electric trivector meter 3 phase 4 wire 0.5 class of accuracy on KW hour point basis complete with HT CTs of 15/5 amp 15 VA burden and class of 0.5 including metering cubical complete in all respects as per site requirement as per HVPN approved make and duly tested by HVPN with required earthing. For Raw Water B/station Khera murar
`AUTOMETIC POWER FACTOR CONTROL PANEL Supply erection testing and commissioning of Automatic Power Factor control panel at 90 KVAR capacitor complete with digital screen as per specification mentioned in the as per approved DNIT. ` For Water Works Kamalpur
Providing anf fixing of indoor type 11KV Vaccum ciruit breaker (VCB) with indoor swirchgear pannel equipped withCT PT and protection relays of Rated voltage 11KV 400A 250 MVA rupturing capacity and short time current rating 13.1 KA for 3sec shunt trip floor mounted horizonTAL ISOLATION horizontal draw out with integral earthing facilitty tested with degree of protection IP4X dustproof vermin proof totally enclosed as per detail specification of make SIEMENS /ABB/ PASCAL/ SCHEINDER complet in all respect
Providing and fixing HT metering panel with GO switch H pole VCB/ACB and all other required electric items complete in all respects as per directions of Engineer-in-charge
Supply and erection of LT copper armound cable for 100volts fitted in cable tray complet in all respect as per approved NIT (3 core x 50 sqm)
Providing and fixing C.I. sluice valves (with cap) c omplete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately):of make IVC (350 mm diameter Class I)
Providing and fixing Cast Iron Detachable Joints marked with IS: 8794 for use with asbestos cement pressure pipes complete with 2 Nos. rubber rings marked with IS:5382 and IS:10292 and appropriate number of nut and bolts marked with 15:1363 including carriage, loading, unloading etc. complete in all respects to the satisfaction of the engineer-in-charge. (Excavation will be paid separately) (350 mm i/d
Provision for Repair/ shifting of existing utilities i.e. HDPE pipe, Cable, UPVC/ CPVC pipe connections of various consumers complete job
`Supply and insertion of 350 mm i/d M.S. Carriar pipe 8 mm thick (Fe-410 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following size including cutting bevelling grindingand radion graphically welding of pipe as per IS 1182complet in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to RDSO as per specification no MandC/PCNIII /88 to a dry film thickness of 250 micron for protection against crossion complet with hydraulic testing in all respect i) For 350 mm i/d M.S. casing pipe 8 mm thick.`
Provision for probe radar survey to check any underground obstruction before finalizing the alignment complete in all respect as per approved
Providing and fixing C.I. sluice valves (with cap) c omplete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately):make IVC/VAG 350 mm diameter Class I
Supply and erction of aluminum armound LT cable for 100volts fitted in cable tray complet in all respect as per approved NIT (Excluding cost of Cable Tary) 3.5corex95sqm
Supply anderction of aluminum armound HT cable for 100volts fitted in cable tray complet in all respect as per approved NIT 3.5corex95sqm
`Supply and insertion of 250 mm i/d M.S. Carriar pipe 5 mm thick (Fe-410 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following size including cutting bevelling grindingand radion graphically welding of pipe as per IS 1182complet in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to RDSO as per specification no MandC/PCNIII /88 to a dry film thickness of 250 micron for protection against crossion complet with hydraulic testing in all respect i) For 250 mm i/d M.S.Carriar pipe 5 mm thick.`
`Providing and fixing H.D.P.E. spacer at a distance of 2 meters apart to avoid contract of casing pipe and carrier pipe for 400 mm i/d M.S. pipe 250 mm i/d complete in all respect as per approved NIT. 250mm i/d 5mm thick.`
Providing concrete block 1:1-1/2:3 on both ends to plug the annular space between casing and carrier pipe for 250 mm i/d casing pipe 400 mm i/d complete in all respect
Providing and fixing sign board of size 2.5mtrx1.5mtr made out of 75x25 mm SS tube 3mm thick with SS grade 304sheet of 3mm painting with synthetic enamle paint and letter writing NABARD pattern complet in all respect n
SUPPLY,ERECTION,TESTING AND COMMISSIONING OF is MARKED 3 CORE COPPER CABLE SOLID COPPER CONDUTOR UP TO 6 SQMM AND BALANCE STANDARD COPPER XLPE INSULATED CORE LAID UP PVC INNER SHEATED ARMOUR gALVANISEDC WIRE FOR CABLE UPTO 10 X 1.5 SQMM 8 X 2.5SQMM 3 X 10 SQMM 4 X 6 SQMM AND BALANCE ALL GALVANISED STEEL STRIP EXTRUDED PVC TYPE ST2 OUTER SHETAED /1100 V GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATDE AMENDENT ALONG WITH ALL ASESSORIES LIKE THIMBLE LUGS ETC FOR MOTOR AS PER ENTIRE SATISFECTION OF eic COMPLETE IN ALL RESPECT MAKE IN INDIA CABLE LTD FINOLEX/GLOSTER/HAVELLS/POLYCABE/RR CABLES/CAPP/GLOSTER/UNIVERSAL/FORT GLOSTER INDUSTRIAL LTD/ASIAN CABLE COPERTARED LTD 50 SQMM 3 CORE
Providing and fixing Meter, Cable and other relevant materials including approval from DHBVN and PHED as per norms for arrangement to transfer the solar power to DHBVN complete in all respect as per satisfaction of Engineer-in-Charge
Supply, erection, testing and commissioning of wall mounted electrical L.T. Panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated of approximate size 1200 x 900 mm and 400 mm deep having follwing items. a) MCCB 100 amp. 1 No. (LandT Siemens, ABB) b) CT 100/3 = 3Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 2 No. d) SPP = 1 No. of approved make e) Motor starter, Star delta = 5800 LPM x 120.00 BHP x 55.00 M. Head (LandT Siemens, ABB) = 2 Nos. f) Capacitor KVAR as per site requirement = 1 No. g) Indicating Lamp = One Set h) Change over switch of suitable Amp = 1 No. (Each)
`Boring /excavation including pit making at entry and exit point to the precise dimensions for the Launch of the specialized Auger boring machine in any soil condition complete in all respect i) For M.S. Pipe 400 mm i/d 6 mm thick casing pipe.`
Boring /excavation including pit making at entry and exit point to the precise dimensions for the Launch of the specialized Auger boring machine in any soil condition complet in all respect i) For M.S. Pipe 350 mm i/d 9.50 mm thick casing pipe.
`Supply and insertion of 350 mm i/d M.S. Casing pipe 9.50 mm thick (Fe-410 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following size including cutting bevelling grindingand radion graphically welding of pipe as per IS 1182 complet in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to RDSO as per specification no MandC/PCNIII /88 to a dry film thickness of 250 micron for protection against crossion complet in all respect i) For 350 mm i/d M.S. casing pipe 9.50 mm thick.`
`Supply and insertion of 200 mm i/d M.S. Carriar pipe 6.0 mm thick (Fe-410 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following size including cutting bevelling grindingand radion graphically welding of pipe as per IS 1182complet in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to RDSO as per specification no MandC/PCNIII /88 to a dry film thickness of 250 micron for protection against crossion complet with hydraulic testing in all respect i) For 200 mm i/d M.S. casing pipe 6.0 mm thick.`
Providing and fixing H.D.P.E. spacer at a distance of 2 meters apart to avoid contract of casing pipe and carrier pipe for 200 mm i/d M.S. pipe 350 mm i/d complete in all respect as per approved NIT. 350mm i/d 8mm thick.
Providing concrete block 1:1-1/2:3 on both ends to plug the annular space between casing and carrier pipe for 200 mm i/d casing pipe 350 mm i/d complete in all respect
`Supply and Eraction of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame :- 4900LPM x130BHP x 70.00 mtr head`
`Boring /excavation including pit making at entry and exit point to the precise dimensions for the Launch of the specialized Auger boring machine in any soil condition complet in all respect i) For M.S. Pipe 500 mm i/d 9.5 mm thick casing pipe`
`Supply and insertion of 500 mm i/d M.S. Casing pipe 9.5 mm thick (Fe-410 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following size including cutting bevelling grindingand radion graphically welding of pipe as per IS 1182complet in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to RDSO as per specification no MandC/PCNIII /88 to a dry film thickness of 250 micron for protection against crossion complet in all respect i) For 500 mm i/d M.S. casing pipe 9.50 mm thick.`
`Providing and fixing H.D.P.E. spacer at a distance of 2 meters apart to avoid contract of casing pipe and carrier pipe for 350 mm i/d M.S. pipe 500 mm i/d complete in all respect as per approved NIT. 350mm i/d 8mm thick.`
Providing concrete block 1:1-1/2:3 on both ends to plug the annular space between casing and carrier pipe for 350 mm i/d casing pipe 500 mm i/d complete in all respect
`Supply and insertion of 350 mm i/d M.S. Casing pipe 6.00 mm thick (Fe-410 grade) fabricated as per IS: 3589 of 1991 from steel plates conforming to IS 2062 of following size including cutting bevelling grindingand radion graphically welding of pipe as per IS 1182 complet in all respect and also coating of inner and outer surface of casing pipe with high built epoxy paint to RDSO as per specification no MandC/PCNIII /88 to a dry film thickness of 250 micron for protection against crossion complet in all respect i) For 350 mm i/d M.S. casing pipe 6.00 mm thick.`
Supplying, erection, testing and commissioning of horizontal motor pumping set for clear water having head 45.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. 1600 LPM x 30.0 BHP x 45 mtr Head (For Raw water )
Supplying, erection, testing and commissioning of horizontal motor pumping set for clear water having head 20.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. 500 LPM x 5.00 BHP x 20 mtr Head (For Raw water)
Supplying, erection, testing and commissioning of horizontal motor pumping set for clear water having head 20.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked. 1200 LPM x 10.00 BHP x 20 mtr. Head for (Raw Water )
`Supply and erection of Horizontal spindle split casing type pumping sets of following duties directly coupled to AC squirrel cage induction type motor with accessories as described in Schedule No II complete in all respect with priming arrangement with complete base frame 1500 LPM x 50 BHP x 85 mtr head for ( Clear water )
Water Treatment Plant (WTP) - Designing, Testing, Construction and Commissioning of 1.50 MLD capacity water treatment plant including inlet channel alum dozing, flash mixing, clari flocculator, fitter box, oven head reservoir for back wash, waste water tank, including all civil work, pumping machinery and electric cabling, control panel, entire piping network of suitable size, laying ,cutting, jointing of DI pipes from raw water pump to inlet box of WTP, WTP to CWT and Suction well for CW including,DI specials suitable size sluice valves, houdies, Manhole cover, air scour equipment, chamical house including chlorination equipment and arrangement of flow measurement and sand bed with automation complete in all respects as per approved NIT. (Sluice valve of make IVC and VAG)
Operation and maintenance for the complete scope of work mention in the DNIT (Disinfection material supplied by the PHED) as per Schedule-IV for a period of 5 years after 12 months during defect liability period and 3 months trial run period (will be charged to the A/ Mtc. Estimate) Operation and maintenance during defect liability period (Operation only)
Operation and Maintenance during 1st year after defect liability period year
Operation and Maintenance during 2nd year
Operation and Maintenance during 3rd year
Operation and Maintenance during 4th year
Operation and Maintenance during 5th year
Bidder Name
Amount
Chahar Construction Co (GSTN-06AAMFC2979A1ZI) BID ID -1011015
Rakesh Yadav Contractor(GSTN-NA)--1010472
Chahar Construction Co
Chahar Construction Co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid