Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAdmitted-Finance 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | ₹7.1 L | L1 | Admitted-Finance |
| 2 | L2₹7.1 LAdmitted-Finance 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | ₹7.1 L | L2 | Admitted-Finance |
| 3 | Rejected-Technical 1BR COLONY POST BACHRA P S PIPARWAR DISTT CHATRA JHARKHAND | CHATRA | JHARKHAND | 825103 | - | - | Rejected-Technical Technically disqualified |
| Sl No | Description | Qty | Unit | RAJA ELECTRICAL WORKS L1 | M/s Kiran Electrical works L2 |
|---|---|---|---|---|---|
| 1.01 | supply and providing of SPD MA 15:- SPD on 230/440V AC side to protect the electronic wright indicator & computer 01 nos. for each WB , rated voltage 230/440V, Pole-3P+N, Imax- 20KA | 6 | no | 17,500 ₹1.1 L | 17,500 ₹1.1 L |
| 1.02 | supply and providing of RCBO with AFDD for protection from electrical shock and fire - 40 amps, 1P+N | 6 | no | 22,500 ₹1.4 L | 22,500 ₹1.4 L |
| 1.03 | Isolation transformer Input voltage – 0 – 415-440VAC
Shield 1 – Copper shield between primary and each secondary with ground terminal
Output voltage – 0-230-250V-415VAC
Output current – 3.5A
VA Rating – 15KVA
Shield 2 – Copper Shield after the outer layer of secondary connected to transformer mounting
Winding material – Copper
Core material – CRNO stampings
Mounting – foot mount with L Clamp | 6 | no | 46,000 ₹2.8 L | 46,500 ₹2.8 L |
| 1.04 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 360 | Mtr | 400 ₹1.4 L | 400 ₹1.4 L |
| 1.05 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 4 sq. mm + 1 X 4 sq. mm earth wire) | 60 | Mtr | 400 ₹24,000 | 400 ₹24,000 |
| 1.06 | Supplying and fixing 5A to 32A rating , 240/415 V , 10 kA , "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections,testing and commissioning etc. as required. Triple pole and neutral | 6 | Nos | 1,150 ₹6,900 | 1,200 ₹7,200 |
| 1.07 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel boardwith ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required-63A | 6 | no | 3,000 ₹18,000 | 3,000 ₹18,000 |
| 2.00 | Total impact of GST for the purpose of CTC | 1 | no | - | - |
Tender Value
Refer Docs
EMD Value
₹9,600
Closing Date
26 Mar 2026, 9:00 amClosed
PE ENM
PE ENM, AKKOCP
Supply and installation of SPD with isolation transformer for road weighbridges installed of AKK OCP, under BnK Area
2026_CCL_357034_2
PE(EnM)/AKK OCP/e-tender/25-26/41
Open Tender
Electrical and Maintenance Works
3 days
AKKOCP
Please refer Tender documents.
3 documents required · 3 mandatory
₹9,600
25 Apr 2026
18 Mar 2026
27 Mar 2026
18 Mar 2026
26 Mar 2026
18 Mar 2026
18 Mar 2026 - 26 Mar 2026
supply and providing of SPD MA 15:- SPD on 230/440V AC side to protect the electronic wright indicator & computer 01 nos. for each WB , rated voltage 230/440V, Pole-3P+N, Imax- 20KA
supply and providing of RCBO with AFDD for protection from electrical shock and fire - 40 amps, 1P+N
Isolation transformer Input voltage – 0 – 415-440VAC Shield 1 – Copper shield between primary and each secondary with ground terminal Output voltage – 0-230-250V-415VAC Output current – 3.5A VA Rating – 15KVA Shield 2 – Copper Shield after the outer layer of secondary connected to transformer mounting Winding material – Copper Core material – CRNO stampings Mounting – foot mount with L Clamp
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (2 X 4 sq. mm + 1 X 4 sq. mm earth wire)
Supplying and fixing 5A to 32A rating , 240/415 V , 10 kA , "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections,testing and commissioning etc. as required. Triple pole and neutral
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel boardwith ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required-63A
Total impact of GST for the purpose of CTC
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.38 MB
BOQ_369897.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid