Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.0 LAccepted-AOC | L1 | Accepted-AOC L1 Quoted | |
| 2 | L2₹10.9 L+₹2.4 L (28.2%)Rejected-AOC KRAL PORA BAGH I MEHTAB NEAR MANCHOWA PETROL PUMP DISTRICT BUDGAM 190019 J K | BUDGAM | BUDGAM | J K | 190019 | L2 | Rejected-AOC L2 Quoted | |
| 3 | L3₹11.2 L+₹2.7 L (31.9%)Rejected-AOC DHARAM SALA SINGHAN CHADOORA DISTT BUDGAM J K | CHADOORA | BUDGAM | JAMMU AND KASHMIR | L3 | Rejected-AOC L3 Quoted | |
| 4 | L4₹13.6 L+₹5.2 L (60.9%)Rejected-AOC DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | L4 | Rejected-AOC L4 Quoted | |
| 5 | L5₹14.4 L+₹6.0 L (70.4%)Rejected-AOC | L5 | Rejected-AOC L5 Quoted |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
31 Oct 2020, 6:00 pmClosed
GE AF SRINAGAR
GE AF SRINAGAR AIR FORCE STATION, SRINAGAR 190007
REPAIR ROUTINE MAINTENANCE OF DG SETS INSTALLED AT VARIOUS LOCATIONS UNDER GE AF SRINAGAR
2020_MES_383201_1
GE (AF)-37/2020-21
Open Tender
Civil Works
Item Rate
270 days
GE AF SRINAGAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF SRINAGAR
₹30,000
Yes
10 Dec 2020
3 Oct 2020
2 Nov 2020
3 Oct 2020
31 Oct 2020
17 Oct 2020
Amount
Servicing of DG Set of following capacity, any Make, checking entire system as per manufacturer's catalogue such as checking all parts for serviceablility, taking down defective parts such as fuel filter assy, by pass filter assembly, lub oil filter assembly, air cleaner assy, flexible hose pipe, coolent etc and replacing the same with same size, make and capacity of parts, draining out the old used burnt engine oil from the sump cleaning all serviceable filters and oil sump with cleaning solution such as petrol/ diesel and refilling new engine oil upto required level and including testing to DG Set to entire satisfaction of Engr-in Charge. Note:- (i) Spare parts/ Engine oil/ check kit/ filter shall be measured and paid for saperately under respective items of BOQ as supply only. (ii) Servicing shall be carried out by authoried dealer of manufacturer. (iii) Minimum 6 months gap/ 200 hrs of run whichever is earlier shall be considered for next service (iv) Repair Guarantee for replaced parts/servicing of DG Set shall be for six month/200 hrs from the date of service.
DG Set 625 KVA
DG Set 500 KVA.
DG Set 400 KVA.
DG Set 250 KVA.
DG Set 200 KVA.
DG Set 160 KVA.
DG Set 140 KVA.
DG Set 125 KVA.
DG Set 100 KVA.
DG Set 82.5 KVA.
DG Set 75 KVA.
DG Set 62.5 KVA.
DG Set 55 KVA.
DG Set 50 KVA.
DG set 30/31.25 KVA.
DG set 15 KVA.
DG set 10 KVA.
DG set 7.5 KVA.
Supply only fuel filter element with set of 'O' Ring for following capacity of DG set.
DG Set 625 KVA
DG Set 500 KVA.
DG Set 400 KVA.
DG Set 250 KVA.
DG Set 200 KVA.
DG Set 160 KVA.
DG Set 140 KVA.
DG Set 125 KVA.
DG Set 100 KVA.
DG Set 82.5 KVA.
DG Set 75 KVA.
DG Set 62.5 KVA.
DG Set 55 KVA.
DG Set 50 KVA.
DG set 30/31.25 KVA.
DG set 15 KVA.
DG set 10 KVA.
DG set 7.5 KVA.
Supply only super bypass filter element suitable for following capacity of DG set.
DG Set 625 KVA
DG Set 500 KVA.
DG Set 400 KVA.
DG Set 250 KVA.
DG Set 200 KVA.
DG Set 160 KVA.
DG Set 140 KVA.
DG Set 125 KVA.
DG Set 100 KVA.
DG Set 82.5 KVA.
DG Set 75 KVA.
DG Set 62.5 KVA.
DG Set 55 KVA.
DG Set 50 KVA.
DG set 30/31.25 KVA.
DG set 15 KVA.
DG set 10 KVA.
DG set 7.5 KVA.
Supply only element lubricant oil filter suitable for following capacity of DG set.
DG Set 625 KVA
DG Set 500 KVA.
DG Set 400 KVA.
DG Set 250 KVA.
DG Set 200 KVA.
DG Set 160 KVA.
DG Set 140 KVA.
DG Set 125 KVA.
DG Set 100 KVA.
DG Set 82.5 KVA.
DG Set 75 KVA.
DG Set 62.5 KVA.
DG Set 55 KVA.
DG Set 50 KVA.
DG set 30/31.25 KVA.
DG set 15 KVA.
DG set 10 KVA.
DG set 7.5 KVA.
Supply only air filter element inner & outer suitable for following capacity of DG set.
DG Set 625 KVA
DG Set 500 KVA.
DG Set 400 KVA.
DG Set 250 KVA.
DG Set 200 KVA.
DG Set 160 KVA.
DG Set 140 KVA.
DG Set 125 KVA.
DG Set 100 KVA.
DG Set 82.5 KVA.
DG Set 75 KVA.
DG Set 62.5 KVA.
DG Set 55 KVA.
DG Set 50 KVA.
DG set 30/31.25 KVA.
DG set 15 KVA.
DG set 10 KVA.
DG set 7.5 KVA.
Supply only Gasket Set suitable for following capacity of DG set.
DG Set 250 KVA.
DG Set 200 KVA.
DG Set 160 KVA.
DG Set 125 KVA.
DG Set 100/ 82.5/ 75/ 62 KVA.
DG Set 55/ 50 KVA.
DG set 30/31.25 KVA.
DG Set 15/ 10/ 7.5 KVA.
Calliberation of FIP complete after replacement of defective worn out parts for the capacity of DG Set 250 KVA complete all as specified and directed by Engineer-in-Charge (i) Bearing bush (ii) Plunger spring (iii) Pump element (iv) Delivery valve and spring (v) Banjo bolt and Benjo (vi) Sealing ring (vii) Oil seal (viii) Gasket (ix) Overflow valve etc
All as per item No 7.00 here-in-before but for DG set 200 KVA.
All as per item No 7.00 here-in-before but for DG set 160 KVA.
All as per item No 7.00 here-in-before but for DG set 140 KVA.
All as per item No 7.00 here-in-before but for DG set 125/100 KVA.
All as per item No 7.00 here-in-before but for DG set 82.5/75/62.5/55 KVA.
All as per item No 7.00 here-in-before but for DG set 31.25/30 KVA.
All as per item No 7.00 here-in-before but for DG set 15/10/7.5 KVA.
Supply and changing engine oil 15W/ 40, Make: Kirloskar / Castrol/ HP
Supply and fixing pipe hose flexible with 2 Nos clamps of same size/ model/ capacity as per existing complete all as specified and as directed.
Supply and changing coolent all as specified and as directed. Make: Servo/ Shell/ Castrol/ HP
Supply and changing distilled water in for filling in batteries all as specified and as directed.
S&F in replacement automatic voltage regulator suitable for 100 to 250 KVA DG set including connections of AVR with panel with and including PVC insulated multistranded copper wires of suitablesize complete all as specified and as directed. Make: Kirloskar/ Crompton/ National/ Universal/ AE
S&F in replacement maintenance free lead acid battery 12 volts 180 AH complete all as specified and as directed. Make : Bosch/ Amaron/TATA GREEN
S&F in replacement maintenance free lead acid battery 12 volts 130 AH complete all as specified and as directed. Make : Bosch/ Amaron/TATA GREEN
S&F in replacement PVC transparent flexible pipe, superior quality, of 10mm dia approximate length 2 RM, tightening the same with two Nos of jublee clips on both ends,complete all as specified and as directed.
Servicing of self starter after disconnecting the same from DG sets, transporting to workshop, strip opening the same and replacing the defective parts/ winding including testing after repair/servicing and refixing in orginal position of capacity 7.5 KVA to 62.5 KVA complete all as specified and directed.
All as per item No 23.00 here-in-before but of capacity 70 KVA to 140 KVA
All as per item No 23 here-in-before but of capacity 160 KVA to 250 KVA
M&L for servicing/ cleaning of MS diesel tank of DG set 250 KVA/160KVA/125 KVA/ 50 KVA/31.25 KVA KVA by draining out the diesel from tank, cleaning the tank with soap water/ suitable solution and painting the external surface with one coat of synthetic enamel paint of existing colour including repalcement of drain valve, outlet pipe complete all as specified and as directed.
S&F in replacement, indicator lamp assembly (set of three) red, yellow, blue complete all as specified and as directed.
S&F in replacement, battery leads copper conductor single core of length 2 x 1.5m of suitable size for 12volt/ 24volt DC with brass terminal heavy duty complete all as specified and as directed.
S&F in replacement, battery charger with auto cut off indicater suitable for 2x12 volts DC complete all as specified and as directed. Make : Sintrac/ Elak
Dismentling/ taking down complete radiator assembly of DG set 250 KVA and transporation to workshop for repair by :- (i) Opening the radiator assembly with brazing/ welding for repair/ services. (ii) Cleaning of all water tube with diluted solution of HCL & cleaning with water preasure & removing the sludge and dust from inside the tank by flushing out. (iii) Repair of fins by soldring/ brazing. (iv) Repair of bottom brass water tank by soldring/ brazing. (v) Repair of radiator hose assembly. (vi) Fixing the complete radiator assembly to its orignal position and testing complete
All as per item No 30.00 here-in-before but DG set 200 KVA.
All as per item No 30.00 here-in-before but DG set 160 KVA.
All as per item No 30.00 here-in-before but DG set 140 KVA.
All as per item No 30.00 here-in-before but DG set 125 KVA.
All as per item No 30.00 here-in-before but DG set 100 KVA.
All as per item No 30.00 here-in-before but DG set 82.5/70/62.5/55 KVA.
All as per item No 30.00 here-in-before but DG set 31.25/30/15/10/7.5 KVA.
S&F in replacement, water temp gauge circular dial complete all as specified and as directed. Make : AE/ VIDEO
S&F in replacement, fan belt suitable for 250 KVA DG set complete all as specified and as directed. Make : - Dollup/ Fenner
All as per item No 39.00 here-in-before but suitable for 200 KVA DG set complete all as specified and as directed.
All as per item No 39.00 here-in-before but suitable for 160 KVA DG set complete all as specified and as directed.
All as per item No 39.00 here-in-before but suitable for 140 KVA DG set complete all as specified and as directed.
All as per item No 39.00 here-in-before but suitable for 125 KVA DG set complete all as specified and as directed.
All as per item No 39.00 here-in-before but suitable for 82.5/ 100 KVA DG set complete all as specified and as directed.
All as per item No 39.00 here-in-before but suitable for 55/62.5/70 KVA DG set complete all as specified and as directed.
All as per item No 39.00 here-in-before but suitable for 30 KVA DG set complete all as specified and as directed.
All as per item No 39.00 here-in-before but suitable for 7.5/10/15 KVA DG set complete all as specified and as directed.
Disconnection of electric connection from DG set control penal, dressing of cable including replacement of burnt out aluminium lugs and fixing with new lugs, nuts bolt complete all as specified and as directed.
Supply and Fixing in replacement of Self Starter of Capacity 24 Volt suitable for Kirloskar /Cummins Dg set all as specified and directed by Engineer in Charge.
Supply and Fixing in replacement of Self Starter of Capacity 12 Volt suitable for Kirloskar /Cummins Dg set all as specified and directed by Engineer in Charge.
Dismentling/ taking down AMF Panel/Control panel of DG Set, replacing following parts and commissioning and testing the panel complete all as specified and directed by Engineer-in-Charge. Note:- panel parts shall be measured and paid separately under respective items as supply only.
Supply Only Contactor 3 pole 400 Amp Capacity Make: L & T, Siemens , Schiender
Supply Only Contactor 3 pole 325 Amp Capacity Make: L & T, Siemens , Schiender
Supply Only Contactor 3 pole 225 Amp Capacity Make: L & T, Siemens , Schiender
Supply Only Contactor 3 pole 70 Amp Capacity Make: L & T, Siemens , Schiender
Supply Only Contactor 3 pole 32 Amp Capacity Make: L & T, Siemens , Schiender
Supply Only Relay 12 volt 8 Pin
Supply Only Relay 24 Volt 8 Pin
Supply Only Eloctronic Timer complete all as specified and directed by Engineer-in-Charge.
Supply Only Line voltage Monitoring Relay 3 Phase 415 Volt complete all as specified and directed by Engineer-in-Charge.
Supply Only Energy Starting Relay 12 Volt complete all as specified and directed by Engineer-in-Charge.
Supply Only start/Stop Switch complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in Replacement of Engine Control Unit complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in Replacement of solenoid switch complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in Replacement of Turbo charger kit complete all as specified and directed by Engineer-in-Charge.
Repair/Replacement of worn out/defective part of Dynamo kit complete all as specified and directed by Engineer-in-Charge.
Material and Labour for transporting trolley mounted DG Set of any capacity from BB Cantt power House to main power house 1 wing AF Srinagar complete all as specified and directed by Engineer-in-Charge.
Opening the silencer from the Gen Set shift to market for repair , descaling the fins with caustic soda , cleaing and washing the same including repairing of broken parts by bronzing /welding of cap 125 to 250 KVA DG Set complete all as specified and directed by Engineer-in-Charge.
Note for all above items: (i)Two Mechanic for the repair of DG set shall be deployed by the contractor during working hours. The each DG set to be repaired within 24 hours, failing to which penalty of Rs 1000/- will be imposed per day till the each DG set is repaired. (ii) All repair work shall be carried out only by authorised person qualified in the relevant trade (iii) Make of components replacement if not specifically mentioned in the relevant item same shall be of the existing make.
M/S RATHER CONSTRUCTION CO
M/s Jaipal Associates
M/S ASHRAF CONSTRUCTIONS
M/S M.Y Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .