Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 LAccepted-AOC NO 13 43 ANNAMALAI NAGAR 3RD STREET WEST MAMBALAM CHENNAI 600 033 | CHENNAI | CHENNAI | TAMIL NADU | 600033 | ₹1.1 L Quoted ₹2.1 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹2.3 L+₹18,231 (8.80%)Rejected-AOC 2 4 J S TOWER G 4 BLOCK A AVVAIYAR STREET MEENAMBAKAM CHENNAI 600 027 | KANCHIPURAM | TAMIL NADU | 600027 | ₹2.3 L+₹18,231 (8.80%) | L2 | Rejected-AOC SECOND LOWEST BIDDER |
| 3 | L3₹2.3 L+₹19,824 (9.57%)Rejected-AOC | ₹2.3 L+₹19,824 (9.57%) | L3 | Rejected-AOC THIRD LOWEST BIDDER |
| Sl No | Description | Qty | Unit | JAYAM ELECTRONICS L1 | BESTMACH L2 | SYSTEMS L3 |
|---|---|---|---|---|---|---|
| 1.00Procurement of Lab Equipments for Electrical and Electronics Engineering Department. | ||||||
| 1.01 | Single Phase Tranformer:
• Single Phase Transformer
• Rating: 1 kVA, 50 Hz
• Input: 230 V ac
• Output: 115 V ac
• Type: Air-cooled, single-phase step-down transformer
• Properly insulated input and output terminals brought out for safe operation | 1 | NOS | 7,200 ₹8,496 Lowest | 8,100 ₹9,558 | 9,500 ₹11,210 |
| 1.02 | Three phase Transformer:
• Rating: 3 kVA
• Input Voltage: 415 V ac, 3-Phase
• Output Voltage: 230 V ac, 3-Phase
• Frequency: 50 Hz
• Winding Material: Copper wound
• Insulation Class: Class B or higher
• Duty: Continuous duty suitable for laboratory use Bench/Floor mounted suitable for laboratory operation.
• All winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation | 1 | NOS | 21,450 ₹25,311 Lowest | 22,000 ₹25,960 | 24,200 ₹28,556 |
| 1.03 | Acidity Test Kit
• Ethyl alcohol
• Sodium carbonate solution
• Universal indicator solution
• Laboratory-grade test tubes
• Droppers
• Colour comparison chart for test result comparison
• Chemicals supplied in labelled containers with safety instructions
• Suitable for laboratory educational and testing applications | 1 | NOS | 3,850 ₹4,543 Lowest | 3,900 ₹4,602 | 4,500 ₹5,310 |
| 1.04 | Loading Rheostat 3 Phase:
• Rating: 5.25 kW
• Supply: 415 V ac, 3-Phase, 50 Hz
• Total Number of Load Steps: 6
• Main switch to be provided
• Approximate dimensions: 18 × 18 × 22 inches (L × B × H) Comprising special cement-insulated electrical load resistors
• Mounted on powder-coated MS panel/enclosure
• Individual ON/OFF rotary switches for load selection
• Mounted on rubber wheels/casters for portability
• Suitable for laboratory load testing applications
• Proper insulation, ventilation, and earthing arrangement to be provided | 1 | NOS | 30,800 ₹36,344 Lowest | 34,000 ₹40,120 | 32,800 ₹38,704 |
| 1.05 | Loading Rheostat 01 Phase:
• Type: Single Phase Loading Rheostat
• Power Rating: 5 kW
• Supply: 230 V ac, Single Phase, 50 Hz
• Total Number of Load Steps: 8
• Approximate Dimensions: 18 × 18 × 22 inches (L × B × H)
• Comprising electrical load resistors suitable for laboratory loading applications
• Resistors shall be special cement-insulated type
• Mounted on powder-coated MS panel/enclosure
• Individual ON/OFF rotary switches provided for load selection
• Mounted on rubber wheels/casters for portability | 1 | NOS | 30,800 ₹36,344 Lowest | 33,500 ₹39,530 | 32,000 ₹37,760 |
| 1.06 | Single Phase Resistive Load
• Type: Single Phase Loading Rheostat
• Power Rating: 5 kW
• Supply: 230 V ac, Single Phase, 50 Hz
• Total Number of Load Steps: 8
• Approximate Dimensions: 18 × 18 × 22 inches (L × B × H)
• Comprising electrical load resistors suitable for laboratory loading applications
• Resistors shall be special cement-insulated type
• Mounted on powder-coated MS panel/enclosure
• Individual ON/OFF rotary switches provided for load selection
• Mounted on rubber wheels/casters for portability | 1 | NOS | 30,800 ₹36,344 Lowest | 34,000 ₹40,120 | 32,000 ₹37,760 |
| 1.07 | Three Phase Resistive Load:
• Rating: 5.25 kW
• Supply: 415 V ac, 3-Phase, 50 Hz
• Total Number of Load Steps: 6
• Main switch to be provided
• Approximate dimensions: 18 × 18 × 22 inches (L × B × H) Comprising special cement-insulated electrical load resistors
• Mounted on powder-coated MS panel/enclosure
• Individual ON/OFF rotary switches for load selection
• Mounted on rubber wheels/casters for portability
• Suitable for laboratory load testing applications
• Proper insulation, ventilation, and earthing arrangement to be provided | 1 | NOS | 30,800 ₹36,344 Lowest | 33,500 ₹39,530 | 32,800 ₹38,704 |
| 1.08 | Three Phase Capacitor Bank:
• 3-phase capacitor bank
• Rating: 2 kVAR
• Voltage: 440 V ac
• Frequency: 50 Hz
• Heavy duty self-healing capacitor units
• Powder coated MS enclosure
• Compact panel mounted/floor mounted construction
• Proper ventilation arrangement to be provided
• Capacitor duty contactor/switch to be provided
• Fuse/MCB protection to be provided
• Discharge resistors to be provided for safety
• Proper earthing arrangement provided | 1 | NOS | 15,950 ₹18,821 Lowest | 16,500 ₹19,470 | 19,500 ₹23,010 |
| 1.09 | On / Off Control of Lamp Using Solid State Relay Kit
• Type : Solid State Relay (SSR) Trainer Kit
• Control/Input Voltage : 12 V / 24 V DC or up to 30 V DC
• Output Load Voltage : 230 V AC, Single Phase
• Load Control : ON/OFF control of AC lamp load
• Solid state relay based switching circuit
• Opto-isolated input control
• Built-in AC lamp load
• Manual ON/OFF switching arrangement
• LED indication for input and output status | 1 | NOS | 3,850 ₹4,543 Lowest | 5,450 ₹6,431 | 5,000 ₹5,900 |
Tender Value
Refer Docs
EMD Value
₹1,000
Closing Date
25 Jun 2026, 10:00 amClosed
PRINCIPAL
GOVERNMENT POLYTECHNIC COLLEGE, CHEYYAR
Refer Tender Notice
2026_DoTE_681629_1
1351/A3/2026
Limited
Laboratory and scientific equipment
Supply
7 days
GOVERNMENT POLYTECHNIC COLLEGE, CHEYYAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹1,000
Yes
17 Aug 2026
18 Jun 2026
26 Jun 2026
18 Jun 2026
25 Jun 2026
18 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Procurement of Lab Equipments for Electrical and Electronics Engineering Department. | |||||
| 1.01 | Single Phase Tranformer:
• Single Phase Transformer
• Rating: 1 kVA, 50 Hz
• Input: 230 V ac
• Output: 115 V ac
• Type: Air-cooled, single-phase step-down transformer
• Properly insulated input and output terminals brought out for safe operation | 1 | NOS | - | - |
| 1.02 | Three phase Transformer:
• Rating: 3 kVA
• Input Voltage: 415 V ac, 3-Phase
• Output Voltage: 230 V ac, 3-Phase
• Frequency: 50 Hz
• Winding Material: Copper wound
• Insulation Class: Class B or higher
• Duty: Continuous duty suitable for laboratory use Bench/Floor mounted suitable for laboratory operation.
• All winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation | 1 | NOS | - | - |
| 1.03 | Acidity Test Kit
• Ethyl alcohol
• Sodium carbonate solution
• Universal indicator solution
• Laboratory-grade test tubes
• Droppers
• Colour comparison chart for test result comparison
• Chemicals supplied in labelled containers with safety instructions
• Suitable for laboratory educational and testing applications | 1 | NOS | - | - |
| 1.04 | Loading Rheostat 3 Phase:
• Rating: 5.25 kW
• Supply: 415 V ac, 3-Phase, 50 Hz
• Total Number of Load Steps: 6
• Main switch to be provided
• Approximate dimensions: 18 × 18 × 22 inches (L × B × H) Comprising special cement-insulated electrical load resistors
• Mounted on powder-coated MS panel/enclosure
• Individual ON/OFF rotary switches for load selection
• Mounted on rubber wheels/casters for portability
• Suitable for laboratory load testing applications
• Proper insulation, ventilation, and earthing arrangement to be provided | 1 | NOS | - | - |
| 1.05 | Loading Rheostat 01 Phase:
• Type: Single Phase Loading Rheostat
• Power Rating: 5 kW
• Supply: 230 V ac, Single Phase, 50 Hz
• Total Number of Load Steps: 8
• Approximate Dimensions: 18 × 18 × 22 inches (L × B × H)
• Comprising electrical load resistors suitable for laboratory loading applications
• Resistors shall be special cement-insulated type
• Mounted on powder-coated MS panel/enclosure
• Individual ON/OFF rotary switches provided for load selection
• Mounted on rubber wheels/casters for portability | 1 | NOS | - | - |
| 1.06 | Single Phase Resistive Load
• Type: Single Phase Loading Rheostat
• Power Rating: 5 kW
• Supply: 230 V ac, Single Phase, 50 Hz
• Total Number of Load Steps: 8
• Approximate Dimensions: 18 × 18 × 22 inches (L × B × H)
• Comprising electrical load resistors suitable for laboratory loading applications
• Resistors shall be special cement-insulated type
• Mounted on powder-coated MS panel/enclosure
• Individual ON/OFF rotary switches provided for load selection
• Mounted on rubber wheels/casters for portability | 1 | NOS | - | - |
| 1.07 | Three Phase Resistive Load:
• Rating: 5.25 kW
• Supply: 415 V ac, 3-Phase, 50 Hz
• Total Number of Load Steps: 6
• Main switch to be provided
• Approximate dimensions: 18 × 18 × 22 inches (L × B × H) Comprising special cement-insulated electrical load resistors
• Mounted on powder-coated MS panel/enclosure
• Individual ON/OFF rotary switches for load selection
• Mounted on rubber wheels/casters for portability
• Suitable for laboratory load testing applications
• Proper insulation, ventilation, and earthing arrangement to be provided | 1 | NOS | - | - |
| 1.08 | Three Phase Capacitor Bank:
• 3-phase capacitor bank
• Rating: 2 kVAR
• Voltage: 440 V ac
• Frequency: 50 Hz
• Heavy duty self-healing capacitor units
• Powder coated MS enclosure
• Compact panel mounted/floor mounted construction
• Proper ventilation arrangement to be provided
• Capacitor duty contactor/switch to be provided
• Fuse/MCB protection to be provided
• Discharge resistors to be provided for safety
• Proper earthing arrangement provided | 1 | NOS | - | - |
| 1.09 | On / Off Control of Lamp Using Solid State Relay Kit
• Type : Solid State Relay (SSR) Trainer Kit
• Control/Input Voltage : 12 V / 24 V DC or up to 30 V DC
• Output Load Voltage : 230 V AC, Single Phase
• Load Control : ON/OFF control of AC lamp load
• Solid state relay based switching circuit
• Opto-isolated input control
• Built-in AC lamp load
• Manual ON/OFF switching arrangement
• LED indication for input and output status | 1 | NOS | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.77 MB
BOQ_819195.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .