Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.3 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹43.6 L+₹1.8 L (4.28%)Rejected-Finance | L2 | Rejected-Finance Not L1 Bidder | |
| 3 | L3₹44.3 L+₹2.5 L (6.01%)Rejected-Finance | L3 | Rejected-Finance Not L1 Bidder | |
| 4 | L4₹45.4 L+₹3.6 L (8.69%)Rejected-Finance | L4 | Rejected-Finance Not L1 Bidder | |
| 5 | L5₹45.9 L+₹4.1 L (9.81%)Rejected-Finance | L5 | Rejected-Finance Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹91,200
Closing Date
27 Dec 2021, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
SPECIAL REPAIR TO BUILDING NO ET 35 AND ET 39 OF ASC CENTRE AND COLLEGE UNDER AGE BR I OF GE CENTRAL BANGALORE
2021_MES_491421_1
8162E
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹91,200
Yes
31 Jan 2022
30 Nov 2021
29 Dec 2021
30 Nov 2021
27 Dec 2021
15 Dec 2021
30 Nov 2021 - 14 Dec 2021
Amount
B/R PORTION : - Dismantling single layer mangalore pattern or similar tiles in roofing.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc and removing debris outside MD land complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing debris outside MD landcomplete all as specified and directed.
Dismantling timber boarding, any description, fixed in any position with nails complete all as specified and directed.
Dismantling timber scantlings 40 Sq.cm and over in section (unframed work), in any position complete all as specified and directed.
Dismantling of timber batten for roof tiles, sheets etc of any size including tilting fillets in section in any position fixed with nails spaced exc 15 cm.
S & F 20 mm thick, second class hard wood boarding, clean sawn, planed one side with butt joints and fixed with screws/nails in any situation as in eaves board, etc complete all as specified and directed.
S & F second class hard wood scantling, clean sawn timber fixed with nails etc complete all as specified and directed.
S & F second class hard wood, clean sawn timber batten sectional area exc 5 sq.cm but not exc 15 sq.cm at 30 cm centre to centre fixed with nails etc complete all as specified and directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) and removing debris outside MD land complete all as specified and directed.
Demolition of reinforced cement concrete any description and in any position not otherwise specifically provided for etc (Manhole cover/slab), cutting reinforcement steel to facilitate demolition of concrete including removing the materials out side MD land complete all as specified and directed.
Taking down chowkats or frame, not exceeding 1.5 Sqm in each with shutters (without taking off shutter from the frame) complete all as specified and directed.
Taking down chowkats or frames, exceeding 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
M & L for Hardcore of broken/crushed stone aggregate of gauge n.exc 63 mm deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 75mm thick Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of floor, etc complete all as specified and directed.
M & L for 25mm thick Plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in level course of floor, etc complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection laid in proper slope/gradient etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
M & L for Precast Reinforced Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab of drain, etc and set in cement mortar 1:4 including necessary form work, moulds, etc complete all as specified and directed by the Engr-in-Charge. (Note : Reinforcement shall be measured and paid separately)
S & F TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for precast cement concrete block masonry type C1, 1:3:6 (20 mm graded granite stone aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M & L for pressed steel frame of size 120X60 mm made out of 1.25mm thick plain black steel sheet for door with one or more rebates including fixing by welding necessary lugs, hinges, lock plate and PCC filling into frame using plain cement concrete 1:3:6, type C1 etc complete all as specified and directed. NOTE : - Butt hinges shall be measured and paid separately as supply only under respective item BOQ.
M&L for 30 mm thick 2nd class hard wood factory made glazed/gauzed skeleton shutters for door, open rebated and prepared to receive glass, gauze etc (without sash bars), edges framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc; size of the members of shutters as specified in SSR Part- I, Section 8, clause 8.24(a) complete all as directed.
S&F 30mm thick Flush shutters, solid core construction, with block coard core & plywood face panels commercial type on both side conforming to IS 2202 (Part- I) -1999, including internal liping beading all round fixed as in Door Shutter,Cup board shutter & Kitchen rack all as specified.
Supply only 100 mm size, butt hinges, medium weight, cold rolled complete all as specified, and directed.
S & F 150 mm long, Aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic film complete all as specified and directed.
S & F 150mm size, Aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and directed.
S & F aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm anodised finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and directed.
S & F box type steel windows/ventilators double side shutters ie glass and wire mesh shutter, including pressed steel frames made out of CRCA sheet of 80X60X1.25mm thick double rebated, shutters box type made out of CRCA sheet of 40X20X1.0mm thick, 12mm square guard bar/grill welded to steel frame, window shutters side hung, ventilator shutters top hung, box type hinges, aluminium die cast handles for glass shutters, iron flat type handles for mesh shutters, telescopic stays etc complete all as specified in TD drawing No TD/539 dated 09.02.2004 of Chief Engineer Chennai Zone and as directed. NOTE:- (i) Qouted rate under this item shall deemed to be inclusive of steel frame, both side steel shutters, guard bars/grills, handles, stays, beading/fillets for fixing glass/wire mesh including cost elements for fixing of glass & wire mesh and mearurement/ payment shall be considered as one unit by comprising all these elements. (ii) Glass and wire mesh shall be measured and paid as supply only underseparately under respective item.
Supply only stainless steel wire cloth 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
S & F 4 mm thick, sheet glass, pin head/figured glass and glazing with oil putty/timber beads in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
M & L for non-skid, ceramic, joint free of matt finish, coloured tiles 8 to 10 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.36 sqm, in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for ceramic, coloured tiles 8 to 10 mm thick as in skirting/dado/vertical surfaces to match the length of floor tile procured under No 31 above including 10 mm thick screed bed in cement mortar 1:3 set & jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for precast chequered cement concrete tiles of size 40cm x 40cm x 25mm thick, as in floors etc, including 20 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed.
S & F for false ceiling of 4mm thick HSPC (High Presure Steam Cured) pre-primed self embossed texured designer ceiling board, cement fibre board of size 595X595 mm (E-Board Classic, white colour) to be fixed in and including GI snap grid with rool formed out of hot dip galvanised steel capings (Powder coated finished) 600X600 mm system. The suspension system consisting of perimeter wall angle of size 38X24X0.90mm of thick GI sheet to secure on wall portion fixed with the help of rawl plug @ 450mm centre to centre universal main runner of T shaped section with single rotary stitching of size (32X24X0.9 mm) made from 0.0.9mm thick GI sheet of length 3.60 metre to be spaced @ 1200 centre to centre cross runner T shaped with double rotary stitching of size (28.6X24X0.9 mm) of length 1200mm made from 0.90 mm thick GI sheet spaced @ 600mm centre to centre (1200X600mm) of size module intermadiate T shaped cross runner of size (28.6X24mm) of length 600mm made of 0.0.90mm thick GI sheet to form (600X600mm) size of module including suspension of the ceiling from the roof/structural members, soffits angles, cleats, by using GI suspenders of 3mm dia GI wire and level adjusters including U clamp of GI fixed in ceiling all complete and making opening by cut out the ceiling board for ceiling light fittings as required and as per manufacturer's instruction or as directed by Eng-in-charge. Make :- Eternit Everest / lafarge/ Armstrong or equivalent as approved by GE
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (Total coated thickness) of any colour, finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with best quality self tapping screws as specified.
S & F Pre-Painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and directed. (Colour of ridge shall be same colour as that of sheet used for roof)
M & L for rendering 15 mm thick in cement mortar 1:6 on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two layer (10mm + 5mm thick) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with water proofing compound at top 5mm thick layer by weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
"Supply only" integral water proofing compound (ISI marked) complete all as specified and directed. (Make : Dr FIXIT/Fosroc/choksey)
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of primer including 1 to 2mm thick wall care putty complete all as specified and directed.
M&L complete removal of existing treatment and applying two coats of distemper oil emulsion over a coat of primer to plastered and other surfaces including providing wall care putty two coats in minimum 1mm to 2 mm thick on plastered surface complete all as specified.
M&L for complete removal of existing treatment of wall and applying two coats of 100% premium acrylic emulsion paint having VOC not less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance dirt resistance exterior paint of approved tint/shade (Company depot tinted) with silicon additive @ 1.43 litre/ 10 Sqm over and including applying priming coat of exterior primer @ 0.90 litre/10 Sqm over new/old surfaces of wall complete all as specified.
M&L preparation of plastered surfaces of wall and applying two coats of 100% premium acrylic emulsion paint having VOC not less than 50gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance dirt resistance exterior paint of approved tint/shade (Company depot tinted) with silicon additive @ 1.43 litre/ 10 Sqm over and including priming coat exterior primer applied @ 0.90 litre/10 Sqm over new surfaces of wall complete all as specified.
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of creosote oil complete all as specified and directed.
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-0, (using 12.50 mm graded stone aggregate) as in coping, kneelers, bed plates etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
E/M PORTION: - Taking down copper/ aluminium point wiring(light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good distrubed surfaces of wall, floors, etc complete.
Point wiring with PVC insulated and unsheathed FRLS cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS-694 1990 drawn in and including PVC rigid non metalic conduit on surface conforming to IS-9537 with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for :- One light or fan point controlled by one 5 Amps switch one way.
All as per item No 49 above but one 3 pin socket point 5 Amp on independent board.
All as per item No 49 above but one 3 pin socket point 5 Amp on same board with other switches.
All as per item No. 49 above but with 2.5 sqmm ( Nominal area ) cable with 2.5 Sqmm size copper earth continuity conductor for 3 pin 15 A socket outlet on independent board complete all as specified and directed.
Supply and fix Switch piano, flush button single pole, 5 Amps one way. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix Switch sokcet combination flush type 5 Amp 2/3 pin muliti purpose Make : Anchor/Cabtree/Legrand/Standard
Supply and fix Switch socket combination flush type 5/15 Amps 3/3 pin universal multipurpose Make : Anchor/Cabtree/Legrand/Standard
Supply and fix Fan regulator electronic, step & socket type 230 volt, suitable for 1200/1400mm sweep ceiling fan. Make : Anchor/Cabtree/Legrand/Standard
Supply and fix Ceiling rose surface bakelite 65x50mm three terminals including supply and fix PVC blocks. Make : Anchor/Cabtree/Legrand/Standard
S&F in replacement LED tube light fitting of 20 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Havells/Crompton Greaves/Bajaj/Philips/Wipro
S&F in repair new generation energy saving environmental friendly long life, with high power LED building street light/security light 1x 35 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP65/66 protection and impact resistant of IK7 prewired with all accessories and connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long and testing on installation all as specified and directed. Make Havells Cat No ENDURAPEARLSL35WLED757SASYTOPCMP or equivelent of Bajaj/phillips/CG/Wipro
S&F in replacement security light bracket made out of 25 mm bore GI Light grade 1.00 M long to required shape as in bracket for steet light fittings fixed with two pair of MS flate iron clamp of size 50mm X 6 mm thickness of required shape with nuts, bolts and washers suitable for steel tubular pole including painting of mild steel flate iron surface with two coates of synthetic enamel paint over a coat of red oxide primer complete including taking down unserviceable one all as specified and directed.
Supply and fix in replacement Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in existing non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board TPN, 415 volts, 4 way horizontal type double door type, 200 Amps rated neutral copper bus bar for housing MCB and fixed and tested on completion complete all as specified.
Supply and fix in replacement Sheet metal enclosure (ISI marked) distribution board for 240 volts, SPN 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete all as directed.
Supply and fix in replacement MCB single pole 6 to 32 Amps 240 volts, C series, 10 kA rupturing capacity.
Supply and fix in replacement MCB single pole & neutral 40 Amps 240 volts, C series,10 kA rupturing capacity.
Supply and fix in replacement MCB Tripple pole & neutral 125 Amps 415 volts, C series,10 kA rupturing capacity providing in DB complete all as specified.
Taking down ceiling/exhaust fan dismantling and painting of ceiling/exhaust fan complete at site with synthetic enamel paint by spraying incl (fittings with filler) one coat after cleaning all dust etc incl connecting up. Provn of twin core cable of suitable size for ceiling rose to connector connecting of earth wire incl replacement of fan capacitor 2.5/3.15 MFD,canopy, bearing/bush, rubber bushes minor nuts bolts screws washers greassing in fan bearing & refix same complete all as directed.
Rewinding of ceiling fan with appropriate size of copper enamelled wire including varnishing ,heating with proper insulation complete and testing all as specified and directed .
M&L, Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.0mm thick buried directly in ground (earth pit depth not less than 2.25m deep below the ground level) with top edge of earth plate at a depth not less than 1.5m below ground level connected to earth using GI earth wire of 4 mm dia by means of of nuts, bolts and washer and check nuts of GI or steel as shown in electrical plate No.3 of MES SSR-2009 (Part-I) and connected to earth test point all as specified or indicated including testing on completion with and including 15mm bore light grade GI protection pipe 7.5 metre long for earth including PCC (1:2:4) pit with RCC (1:2:4) type B-1 cover, 40mm thick reinforced with 6mm dia MS bars @ 100mm both ways with lifting hooks made out of 6mm dia MS bars, watering arrangement with 20mm dia light grade pipe, funnel, wire mesh, common salt chorcoal, necessary excavation and earth work in any type of soil complete all as specified.
docileworx
Srisrinivasaenterprises
SHRI NARAYANADRI ENGINEERS & BUILDERS
M.VENKATARAMANAPPA AND COMPANY
PAVAN TECHNO CONSTRUCTIONS
SREE BALAJI CONSTRUCTIONS
B5BUILDING SOLUTIONS
SHREE BANASHANKARI ASSOCIATES
Elite Constructions
S R CONSTRUCTIONS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .