Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹3.8 LAccepted-Finance 189 TEACHEARS COLONY THAKUR PLOT TAJBAG NAGPUR 440024 | NAGPUR | MAHARASHTRA | 440024 | ₹3.8 L | L-1 | Accepted-Finance Being L - 1 Bidder. |
| 2 | L-2₹4.3 LRejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | ₹4.3 L | L-2 | Rejected-Finance Being L - 1 Bidder. |
| 3 | L-3₹4.7 LRejected-Finance H NO 304 SHRADDHA COLONY MHADA N 2 CIDCO AURANGABAD 431001 | AURANGABAD | MAHARASHTRA | 431001 | ₹4.7 L | L-3 | Rejected-Finance Not being L - 1 Bidder. |
| Sl No | Description | Qty | Unit | M K ENTERPRISES L1 | Manish Electricals L2 | Opal HVAC Services L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply of 3.0 TR mega inverter split air conditioner having reciprocating / rotary / scroll type compressor, rated cooling capacity not less than 10540 watts, 100% copper condenser, cordless remote control, refrigerant type R-32, suitable for operation on 230 V, 50 Hz, 1-Ph AC power supply, suitable for operation in ambient temperature of range 18 - 50 Deg.C etc. complete as required. | 4 | Nos. | 68,500 ₹2.7 L | 86,500 ₹3.5 L | 82,382 ₹3.3 L |
| 2.00 | Installation, testing & commissioning of 3.0 TR mega split air conditioner by fixing indoor unit on wall/ceiling/structure and outdoor unit on floor/wall/stand including providing & fixing suitable size duly painted / powder coated M.S. / G.I. equal angle base frame (ODU Stand), fasteners, first charging of refrigerant gas i/c minor civil works and all accessories etc. complete as required. | 4 | Nos. | 4,500 ₹18,000 | 900 ₹3,600 | 2,900 ₹11,600 |
| 3.00 | Supply & fixing of suction/discharge refrigerant copper piping for 3.0 TR mega split AC insulated with elastomeric nitrile rubber between indoor and outdoor units with suitable size of clamp / MS hanger / MS support / MS angle as per site requirement and as per technical specifications as required. | 50 | Metre | 1,030 ₹51,500 | 1,250 ₹62,500 | 1,900 ₹95,000 |
| 4.00 | Providing and fixing in position of 25 mm dia. UPVC drain pipe including cutting, jointing with approved solvent cement compound etc. complete as per manufacture's specifications as required. | 50 | Metre | 75 ₹3,750 | 110 ₹5,500 | 290 ₹14,500 |
| 5.00Supply & fixing of flexible PVC insulated multicore PVC sheathed, multi stranded copper conductor cable suitable for voltage grade up to 1100 volt confirming to IS-694:2010 as per list of approved makes. | ||||||
| 5.10 | 3 CORE X 2.5 SQ.MM | 50 | Metre | 185 ₹9,250 | 145 ₹7,250 | 190 ₹9,500 |
| 6.00 | Dismantling of existing split air conditioners of 1.5 TR / 2.0 TR capacity & shifting the complete unit up to AAI's store or as directed by Engineer-in-charge. | 5 | Job | 800 ₹4,000 | 500 ₹2,500 | 900 ₹4,500 |
| 7.00 | Re-Installation, testing & commissioning of existing 1.5 / 2.0 TR split air conditioner by fixing indoor unit on wall / ceiling / structure and outdoor unit on floor / wall / stand including dehydration, providing charging of suitable refrigerant gas with leak testing, connections etc. complete as required | 5 | Job | 3,000 ₹15,000 | 1,200 ₹6,000 | 1,200 ₹6,000 |
Tender Value
₹4.3 L
EMD Value
₹12,768
Closing Date
28 Apr 2026, 3:00 pmClosed
DGM (E-E), DBAI Airport, Nagpur.
O/o DGM (E-E), AAI, DBAI Airport, Nagpur.
Provision of ACs for IMD at DWR Building at DBAI Airport, Nagpur
2026_AAI_274326_1
AAI/NGP/AC/NIT-01
Open Tender
Electrical Works
60 days
DBAI Airport
Please refer Tender documents.
12 documents required · 12 mandatory
₹1,180
₹12,768
20 May 2026
9 Apr 2026
29 Apr 2026
9 Apr 2026
28 Apr 2026
9 Apr 2026
9 Apr 2026 - 15 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Supply of 3.0 TR mega inverter split air conditioner having reciprocating / rotary / scroll type compressor, rated cooling capacity not less than 10540 watts, 100% copper condenser, cordless remote control, refrigerant type R-32, suitable for operation on 230 V, 50 Hz, 1-Ph AC power supply, suitable for operation in ambient temperature of range 18 - 50 Deg.C etc. complete as required. | - | Nos. | - | - | Item No: 1 |
| 2 | Installation, testing & commissioning of 3.0 TR mega split air conditioner by fixing indoor unit on wall/ceiling/structure and outdoor unit on floor/wall/stand including providing & fixing suitable size duly painted / powder coated M.S. / G.I. equal angle base frame (ODU Stand), fasteners, first charging of refrigerant gas i/c minor civil works and all accessories etc. complete as required. | - | Nos. | - | - | Item No: 2 |
| 3 | Supply & fixing of suction/discharge refrigerant copper piping for 3.0 TR mega split AC insulated with elastomeric nitrile rubber between indoor and outdoor units with suitable size of clamp / MS hanger / MS support / MS angle as per site requirement and as per technical specifications as required. | - | Metre | - | - | Item No: 3 |
| 4 | Providing and fixing in position of 25 mm dia. UPVC drain pipe including cutting, jointing with approved solvent cement compound etc. complete as per manufacture's specifications as required. | - | Metre | - | - | Item No: 4 |
| 5 | Supply & fixing of flexible PVC insulated multicore PVC sheathed, multi stranded copper conductor cable suitable for voltage grade up to 1100 volt confirming to IS-694:2010 as per list of approved makes. | - | - | - | - | Item No: 5 |
3 CORE X 2.5 SQ.MM | - | Metre | - | - | Item No: 5.10 | |
| 6 | Dismantling of existing split air conditioners of 1.5 TR / 2.0 TR capacity & shifting the complete unit up to AAI's store or as directed by Engineer-in-charge. | - | Job | - | - | Item No: 6 |
| 7 | Re-Installation, testing & commissioning of existing 1.5 / 2.0 TR split air conditioner by fixing indoor unit on wall / ceiling / structure and outdoor unit on floor / wall / stand including dehydration, providing charging of suitable refrigerant gas with leak testing, connections etc. complete as required | - | Job | - | - | Item No: 7 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TenderDocument.pdf
Tender Documents • 14.52 MB
BOQ_320291.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid