Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC 363 39KA HASSANGANJ BAWLI KUMAR COMPANY 363 39 KA HASAN GANJ BAWLI SAADAT GANJ LUCKNOW SAADATGANJ | L1 | Accepted-AOC Quoted L1 | |
| 2 | L2₹9.3 L+₹1.0 L (12.2%)Rejected-AOC 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L2 | Rejected-AOC Quoted L2 | |
| 3 | L3₹9.9 L+₹1.6 L (19.4%)Rejected-AOC 5021 1 CAT III MODERN HOUSING COMPLEX MANIMAJRA CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | L3 | Rejected-AOC Quoted L3 | |
| 4 | L4₹11.4 L+₹3.1 L (37.6%)Rejected-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L4 | Rejected-AOC Quoted L4 | |
| 5 | L5₹11.6 L+₹3.3 L (39.6%)Rejected-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-AOC Quoted L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
29 Jul 2022, 6:00 pmClosed
GE(AF) Chandigarh
GE(AF) Chandigarh PIN-160003
REPAIR TO INTERNAL ELECRTRIFICATION,MCBs and DBs AND OTHER FITTINGS AND FIXTURES IN TECHNICAL AREA AT MAIN CAMPUS OF GE (AF) CHANDIGARH
2022_MES_533461_1
GE(AF)/CHD/T-17/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
Chandigarh
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE(AF) Chandigarh
₹40,000
Yes
9 Sept 2022
24 Jun 2022
1 Aug 2022
24 Jun 2022
29 Jul 2022
16 Jul 2022
24 Jun 2022 - 30 Jun 2022
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, removing materials to store for keeping in safe custody or for taking credit (credit for mentioned items shall be made as per conditions separately) and making good disturbed surface of walls, floors, etc. complete all as specified and directed.
M&L for point wiring complete with single core multi stranded Copper conductor cable of size 1.5 sqmm PVC insulated unsheathed 1100 volt grade in and including PVC conduit of size 20 mm dia or higher including Tee, junction, bends etc concealed in wall/fixed on ceiling and including M.S Suken boxes of suitable size for housing switches, socket etc including 1.5 sqmm green PVC insulated wire for earth continuity complete all as specified and directed.
One light/fan point controlled by one way switch
One three pin 5 amp socket outlet multipurpose on independent board
One three pin 5 Amp switch socket cum on same board
All as per item No 2 above but with 2.5 sqmm cable insulated for 3 pin 15 amp multipurpose outlet including 1.5 sqmm PVC insulated copper wire for earth continuity on independent board complete all as specified and directed.
S&F in replacement of switch piano type, flush type, single pole, one way, 5 Amps complete all as specified and directed.
S&F in replacement of socket outlet flush type 2/3 pins, 6 Amps multipurpose, complete all as specified and directed.
S&F in replacement of switch piano type, flush type, single pole, one way, 16 Amps, complete all as specified and directed.
S&F in replacement of socket outlet, flush type, multi purpose 3 pin, 6 Amps & 16 Amps, 230 volts, complete all as specified and directed.
S&F in replacement of switch bell push, flush type, 05 Amps (230 volts) ,complete all as specified and directed.
S&F in replacement ceiling rose, surface bakelite, 65 x 50 mm, two to three terminals, complete all as specified and directed.
S&F in replacement ceiling fan regulators, step type, electronic for 1200/1400 mm sweep complete all as specified and directed.
S&F in replacement of wiring for circuit/Sub main wiring along with earth wire with two runs single core 2x 4 Sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper FRLS conductor in and including PVC concealed conduit 20mm dia or higher ISI marked including one run of continuous PVC insulated FRLS multi stranded copper cable of size 1x4 Sqmm earth wire for earth continuity conductor complete all as specified and directed. Note: Two runs of 4 sqmm single core and one run of 4 sqmm single core with PVC Conduit complete will be measured as one unit.
S&F in replacement of wiring for circuit/Sub main wiring along with earth wire with two runs single core 2x 6 Sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper FRLS conductor in and including PVC concealed conduet 20mm dia or higher ISI marked including one run of continuous PVC insulated FRLS multi stranded copper cable of size 1x6 Sqmm earth wire for earth continuity conductor complete all as specified and directed, Note: Two runs of 6 sqmm single core and one run of 6 sqmm single core with PVC Conduit complete will be measured as one unit.
S&F in replacement sheet metal enclosure for Incoming MCCB and outgoing MCBs factory made double door, VTPN 415 Volts 4 ways with 200 Amp bus bar with IP43 protection complete in all aspects all as specified and directed.
Supply, fix, connecting and testing MCCB four pole, 100 Amps, 415 volts, 16kA breaking capacity with fixed thermal and magnetic conforms to IS/IEC:60497-2 including taking down the existing one complete all as specified and directed.
Supply, fix, connecting and testing MCCB four pole, 125 Amps, 415 volts, 16kA breaking capacity with fixed thermal and magnetic conforms to IS/IEC:60497-2 including taking down the existing one complete all as specified and directed.
S&F in replacement sheet metal enclosure single pole and neutral with a two pin & earth plug and socket complete including one Double pole MCB 20 Amps, 'C' series 240 volts 10 KA complete all as specified and directed.
S&F in replacement MCB SP 240 Volts, 6 Amps to 32 Amps, 10 KA, 'B' series complete all as specified and directed.
S&F in replacement MCB SP 240 Volts, 63 Amps,10 KA, 'B' series complete all as specified and directed.
S&F in replacement MCB, SPN, 240V, 63 Amps AC, 10 KA, 'B' series complete all as specified and directed.
S&F in replacement MCB, SPN, 240V, 40 Amps AC, 10 KA, 'B' series complete all as specified and directed.
S&F in replacement DB sheet metal enclosure, double door for MCBs, company made, SPN 240 Volts, 8 ways with IP 42 protection complete all as specified and directed.
S&F in replacement DB sheet metal enclosure, double door for MCBs, company made, SPN 240 Volts, 4 ways with IP 42 protection complete all as specified and directed.
S&F in replacement LED light fitting mirror type with high output diffuser, 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
S&F in replacement of round slim surface mounted LED panel 6 Watt 6500 K with PDC aluminium housing and high transparent frosted plastic diffuser to ensure glare free & even light distribution Complete all as specified and directed.
S&F in replacement of LED lights fitting compact commercial batten type suitable for single T8 LED tube 1x 20 Watt , including LED tube light 20 watt connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in replacement of LED luminaries 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement of louvers suitable for exhaust fan steel body of size 300 mm sweep complete all as specified and directed.
S&F in replacement of louvers suitable for exhaust fan steel body of size 450 mm sweep complete all as specified and directed.
S&F in replacement of LED flood light luminaries 200 Watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP-66 protection, system efficacy not less than 110 lumens per watt with 10KV built-in surge protection device with electrical connections complete all as specified and directed.
S&F in replacement energy saving, environment friendly & robust highbay LED 150 watt with PDC housing suitable for industrial application for ceiling (surface/suspended) made up of pressure die cast aluminium housing with toughened glass and high power LEDs with IP-66 protection, system efficacy not less than 110 lumens per watt with 10KV built-in surge protection device with electrical connections complete all as specified and directed.
S&F in replacement indoor elegant suspended LED light fittings 36 watt 4 feet lighting solution 75 mm width and 85 mm height, clean luminance level with mounting arrangements , efficacy not less than 100 lumens per watt with electrical connections including joining kit and mains cable complete all as specified and directed.
M&L disconnecting and taking down the complete exhaust fan flame proof of 300 mm sweep 240/415 V from the existing location and carry out rewinding by dismantling from frame with and including super enameled copper wire of suitable gauge including replacement of insulating materials such as laminated lethroid paper, sleeves, necessary varnishing with golden colour varnish, greasing, lubricating, replacement of missing / worn out nuts, bolts & washers, split pins etc. and testing, complete all as specified and directed.
S&F in replacement of LED drivers suitable for 35/36 watts 2x 2 panel fittings complete all as specified and directed.
HARISH SALES CORPORATION
M/s APEX ENTERPRISES
PARTAP ENGINEERING WORKS
SANJEEV ENTERPRISES
R D Bansal
GS Engineers
M/s Friends Engineering Works
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .