CE (GSS)
DCSEM, V.S. Bhavan.
Comprehensive maintenance of split AC units, water coolers etc. installed at Dhruva Guest House, New Delhi
2022_DCSEM_731369_1
DCSEM/CQD/QSC/ Dhruva-AC-AMC/NIT-LT/31/22-23
Limited
Miscellaneous Works
Item Rate
730 days
New Delhi
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹19,000
13 Jan 2023
27 Dec 2022
13 Jan 2023
27 Dec 2022
11 Jan 2023
27 Dec 2022
27 Dec 2022 - 5 Jan 2023
Amount
Comprehensive maintenance and servicing of the following window/split type AC unit once in a quarter as per Technical Specification of Tender. Note: for both item No.1 & 2: The department reserves the right to increase or decrease any number of such AC units on pro-rata basis.
DAIKIN AC Model No.FYT/RY60 Please refer inventory sheet for Quantity breakup.
DAIKIN AC Model No.FTHP60SRV16 Please refer inventory sheet for Quantity breakup.
1.5TR Split type AC units Voltas make
2 TR Split type AC units Voltas make
Comprehensive maintenance and servicing of water coolers of 40/80 Ltrs. as per Technical Specification of Tender once in a quarter.
Removing & Reinstallation of Air-Conditioners
Dismantling and safe removing the old existing wall mounted split air conditioner along with pump down refrigerant of the system, safely removing its copper piping, safety stand and packing of existing piping holes etc. complete all as per requirement and instructed by EIC and transporting the air-conditioner along with useable items to store room / maintenace room at Dhruva Guest House premises. Agency to take away dismentalled old unuseable items like drain pipes, damaged refrigerant pipes etc. as certified by EIC from the site and suitable rebate aginst these takeaway items to be offered while quoting this item.
Shifting of wall mounted split air-conditioner & other associated items from store room / maintenance room of Dhruva Guest House, installation, testing & commissioning of the wall mounted split air conditioner at new location at Dhruva Guest House including inter connecting copper piping, cabling, drain piping between IDU to ODU, fabrication work, leak testing for entire system, vaccumising using vacuum pump with suitable refrigerant charging as per installation manual, for smooth operation of AC`s etc complete all as per the instructions & to the entire satisfaction of EIC. NOTE: 1) Copper pipe, drain pipe, Cables, fabrication work will be paid separately in relevant item of SOQ. 2) Main Power supply point will be provided by department at free of cost.
Refrigerant piping with rubber nitrile insulation: Supply, installation, testing & commissioning of copper refrigerant pipes as per site condition with necessary structural clamps/ supports/ bends/ elbows/ reducers/U-bends/ flare nuts/ adapters/any other brass fittings as required etc. along with nitrile rubber insulation wrapped with monsoon tape all as per AC's manufacturer's standards.
15.4 mm (5/8)'' with 10 mm rubber nitrile
12.7 mm (1/2)'' with 10 mm rubber nitrile
6.4 mm (1/4)'' with 10 mm rubber nitrile
Supply, installation, testing & commissioning of PVC drain piping of size 25 mm/32 mm diameter duly insulated with heatlone sheet, etc. complete all as per the site condition & instructed by EIC.
Supply, installation, testing & commissioning of Control cabling with adequate size of copper conductor wire/ power cable to connect outdoor units with respective indoor units & power cable to connect power outlet to ODU/IDU complete with lug connections etc. complete all as per site situation as required & instructed by the Engineer-in-charge.
4 core x 2.5 sq.mm cable
3 core x 2.5 sq.mm cable
One time Repair & servicing of DAIKIN make split air-conditioning machine as below
One time repair & servicing of each unit of DAIKIN AC Model No.FTHP60SRV16 using water jet pump including leak testing for entire system, vaccumising using vacuum pump with suitable refrigerant charging as per installation manual, for smooth operation of AC`s etc complete all as per the instructions & to the entire satisfaction of EIC. Scope of work also include sealing of gap around refrigerant pipe in wall crossing using white cement & providing insulation on pipes wherever damaged.
Supply installation testing & commissioning of following spares suitable for DAIKIN make split AC Model No.FTHP60SRV16 as & when required.
Indoor Motor
Swing Motor
Indoor condensate drain pipe
Removing, repairing, re-installating, testing & commissioning of PCB (electronic controller) suitable for DAIKIN split AC Model No.FTHP60SRV16.
Supplying and fixing 50mm uPVC UV-Stabilised soil / waste quality pipes and fittings (SWR) for soil, waste, vent, antisyphonege, HVAC waste pipe and rainwater pipe lines consisting following items of work : i) Supplying uPVC UV-Stabilised Soil / wastepipe as per IS:13592 and IS:14735 Grade-B with Fittings of Supreme make ii) Fixing the pipeline vertically using Metal clamps with rubber seal of Supreme make Cat. No. SWRMCR 1 to 6. iii) Providing and fixing uPVC cowl at the top of soil, waste water & vent pipe line. iv) Laying the pipe below floor / ground to proper slope and gradient for making connections of soil pipe line with inspection chamber or Manhole, waste water connection with Gully trap Chamber including the cost of cement mortar, cementconcrete,water proofing compound etc. v) Jointing the pipe with Solvent Cement & Rubber ring gasket with making holes in walls / floor grooving and redoing the same and brick support etc. Giving water-tightness test for the pipes laid as per codal provisions. Providing Ring Joint pipes at verticals and solvent cement jointed pipes at concealed locations. vi) Necessary cutting to the required length including short pieces, fittings with & without door, assorted fittings such as plugs,tees, couplers, reducers, cross tees, reducingtees, elbows, bends, cleaning pipe, single & double Y, vent cowl, gaskets, offsets etc. For Soil & waste and Vent pipe lines including termination/ fixing of AC drain pipe in Y. vii) Scope of work include providing scaffolding / man lifter for installation of pipe from terrace to ground floor with all safety preclusions as per standard practice.
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .