Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.7 CrAccepted-AOC | ₹16.7 Cr Quoted ₹16.8 Cr | 1 | Accepted-AOC ACCEPTED |
| 2 | 2₹17.9 CrRejected-Finance | ₹17.9 Cr | 2 | Rejected-Finance Rejected |
| 3 | 3₹18.4 CrRejected-Finance | ₹18.4 Cr | 3 | Rejected-Finance Rejected |
Tender Value
₹17.2 Cr
EMD Value
₹27.2 L
Closing Date
4 Dec 2019, 3:00 pmClosed
CCE(RND) SOUTH
Akbar Road, Secunderabad
PROVISION OF INFRASTRUCTURE FOR ESTABLISHMENT OF ADVANCED HILS FACILITY AT RCI, HYDERABAD
2019_DRDO_520100_1
83551/CIV/HILS/CON
Limited
Civil Works
480 days
RCI Hyderabad
as per NIT
2 documents required · 2 mandatory
₹3,000
CCE(RND) SECUNDERABAD
₹27.2 L
2 Jun 2020
19 Nov 2019
6 Dec 2019
19 Nov 2019
4 Dec 2019
25 Nov 2019
20 Nov 2019 - 22 Nov 2019
Amount
SUBHEAD - I : EARTH WORK
Earth work in excavation by mechanical means (Hydraulicexcavator)/manual meansover areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan)including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge.
All kinds of soil
Ordinary rock
Hard rock (Blasting prohibited)
Hard Rock (Blasting prohibited)
Earth work in Excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Excavation Work by Mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.
Ordinary Rock
Hard Rock (Blasting prohibited)
Extra for every Additional Lift of 1.5 m or part there of in excavation / banking excavated or stacked materials.
All kinds of soil
Ordinary or hard rock
Filling Available Excavated Earth (Excluding Rock) in trenches,Plinth sides of foundatios etc,in layers not exceeding 20cm in depth consolidating each diposited layer by ramming and watering,lead upto 50meter and lead upto 1.5meter
Supply of of approved Earth obtained from outside MOD land filling in layers not exceeding 20cms thick at all heights and depths in foundations, pits, trenches, sewer lines around structures and foundation under floors other places including dressing and levelling watering, consolidation to achieve minimium of 95% proctor density etc., complete as per drawing specifications, payments shall be made for the quantity after deducting the voids.
Supplying and filling in plinth with river sand under floors, including watering,ramming, consolidating and dressing complete.
Credit of Hard rock
SUBHEAD : II - ANTI TERMITE TREATMENT:
Supplying Chemical Emulsion in sealed containers including delivery as specified.
Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: (i) With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (a) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: (i) With Chlorpyriphos/Lindane E.C. 20% with 1% concentration.
SUB HEAD - III : PLAIN AND REINFORCED CEMENT CONCRETE WORK:
Providing and laying in position Cement Concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
Providing and laying cement concrete in attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for Reinforced Cement Concrete Work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :-cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).
All works upto plinth level.
All works above plinth level upto floor V level.
Deduction for not pumping of concrete to site of laying.
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately)
All works upto plinth level.
All works above plinth level upto floor V level.
Same as the above but M-30 grade concrete
Add / Deduct for using extra cement in the items of design mix over and above the specified cement content therein.
Supplying fabricating and fixing in position Reinforcement Steel for RCC work at all levels and locations including the cost of steel, straightening, cutting,bending,binding and placing in position etc.,as per drawings and specifications including the cost of binding wire labour etc., complete for reinforced concrete.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) including Providing & applying a coat of DAMP PROOF membrane approved on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Making Plinth Protection 50mm thick of Cement Concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand including finishing the top smooth.
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification ( per 50 kg cement).
Centering and Shuttering including strutting, propping etc and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete.
Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Columns, Pillars, Piers, Abutments, Posts and Struts.
Stairs, (excluding landings) except spiral-staircases
Weather shade, Chajjas, corbels etc., including edges.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5 m, for every additional height of 1 meter or part thereof (Plan area to be measured). (a) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured).
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
Supply and fixing of 100 mm thick 100 mm deep high density rubber strip with approved colour and including with all necessary fixing and fitting complete as per direction of engineer in charge.
SUB HEAD - IV : BRICK WORK:
Random Rubble Masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : a) Cement mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : a) Cement mortar 1:6 (1 cement : 6 coarse sand).
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Providing and placing in position 2 Nos 8mm dia. M.S. Bars at every third course of half brick masonry. a) Cement mortar 1:4 (1 cement : 4 coarse sand).
SUB HEAD - V : PLASTERING & SURFACE TREATMENT :
6 mm Thick Plastering in cement mortar 1:3 (1 cement: 3 fine sand) at all levels and locations for all concrete surfaces of columns, beams,walls, and slabs finished smooth and even etc., complete.
Providing of 12 mm cement plaster of mix in all surface with (a) cement mortar 1:6 (1 cement : 6 fine sand) at all levels.
15 mm cement plaster on rough side of single or half brick wall of mix: a) 1:6 (1 cement: 6 coarse sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Flush/ Ruled pointing All Round the perimeter
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Providing and fixing Chicken wire Mesh 22 Guage of approved make with all necessary hard ware at the junction of RCC and brick work with required overlapping as directed by Engineer-in Charge etc., complete.
Providing and Applying two coats of oil bound distemper of approved brand and shade over and including one coat of primer, including preparation of surface etc.,complete as directed.& with plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete.
Finishing walls with textured exterior paint of required shade:
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and includingpriming coat of exterior primer applied @ 2.20kg/10 sqm
Providing and applying two coats of synthetic enamel paint of approved brand and shade over a coat of primer including preparation of surface and applying approved brand putty on following surfaces at all levels and locations etc., complete.
Steel surfaces with zinc chromate primer.
Wooden Surfaces
SUB HEAD - VI : FLOORING WORK:
Providing and Laying Vaccum dewatered cement concrete 1:1.5:3(1 cement ;1.5 coarse sand and 3 graded aggregate of 20mm)flooring in alternate panels of 3x4m including reinforcement 10mm at 150c/c .Vaccum dewatered technic to accelerate the evaporation of excess water in green concrete using rigid or flexible suction mat incorporating filter layer and vaccum generators (80 to 90% vaccum to be applied at the rate of 3 to 5 minute per 25mm depth ) all as per specification including cutting grooves 4mmx20mm deep in flooring with diamond saw cutting machine before the concrete is seven days old including providing and filling the grooves with polysulphate sealant of approved make or equivalent (modified semi rigid epoxy joint filler ) including cost of required the panel shuttering work with steel channel and as per direction of Engineer-In- charge.The work shall be carried out by specialist agency approved by Engineer -in charge
Anti static Flooring : Preparing the concrete floor surface using captive shot blasting machine .Cut open all construction joints to fill with epoxy putty using Nitocote VF or Equivalent .Same treatment will be carried out to treat shrinkage joints.Providing and laying one coat of Nitoprime 25 or equivalent .Providing and applying Nitoflor SL or equivalent conductive undercoat and overcoated with Notoflor SL or equivalent conduvtive top coat in 2mm thick over primed surface at 7.5 sq mt per pack and finishing as per Forsroc specification .When measured for surface resistance in accordance with BS2050:1978 (A-1984) and DIN EN 1081 ,the static conductive topping including under coat shall be in range of 50-1000 K ohms. When tested for static decay as per Federal test method 101B ,Method 4046, the static conductive tppic shall take not more than a time of 0.01 seconds to decay with +5KV peak charge to 0% .The surface resistance of the conductive undercoat shall be in the range of 3-9 K ohms .Note : Copper strip will be provided to connet earthing point for safe discharge of charges .Make : Forsroc or Equivalent.
Providing and laying Double Charged vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Made of NITCO Company :Model name -Bermuda or Made of Somany ompany :Model name Celestial /Elegance series or Made of Kajaria company :Model name Super Glossy Nanotech K-6016/6018/6019/6101/6012 & Jhonson Make : Quarzet DK & Quarzet HL Or Equivalent a) Size of Tile 600x600 mm.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Makes : Johanson , sandex Series or equivalent
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and laying Non-Skid Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. Makes : Johanson , sandex Series or equivalent
Providing and fixing Ist quality Ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Makes : Johanson , sandex Series or equivalent
SUPPLY OF LABAN FALSE FLOORING-False flooring will consist of 600 mm x 600mm x35 mm size panel made from steel. The bottom of the panel shall be embossed in 64 hemispherical shape of 60mm dia .the top sheet shell be plain and resistant welded at various locations after the top & bottom sheets have been degreased and phosphate.the above hollow panel shall be coated with epoxy coating on the exposed suface.panel shall remain flat through and stable unaffected by humidity or fluctuation in temperature throughtout its normal working lifts. Panels shell provide for impacts resistance top surfaces minimal defection,corrosion,resistance properties and shell not be combustible or aid surface spread of flame.panels shall be 600x600mm and shall have a maximum flange of 12mm on all four sides (for resting on stringer),fully interchangeable with each other within the range of a specified layout.The overall system shall be albe to withstand a UDL of 1350 kgs per sqmt.and a point Load of 450 kgs Accessories with heigth 600mm.Accessories - 1. 300 floor Pedestal 2. Floor Stringers 600mm
Sub Head -VII - STRUCTURAL STEEL WORK
Supplying and fixing Rolling Shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. a) 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Providing and fixing stainless steel (Grade 304) Railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing using steel work welded in built up sections/ framed works for ladder, etc., using MS flats, MS Angles excluding use of chequered plate where ever required by cutting,hoisting, fixing in position and applying two coats of synthetic enamel paint over and including one coat of approved steel primer at all heights etc., complete all as directed.
Structural steel work riveted, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
SUB HEAD - VIII : STEEL, WOOD, UPVC & ALUMINIUM WORK :
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
(Profile C) Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing 35mm thick Flush Door Shutters, with commercial ply with teak veneering on the both sides or approved make, core of block board construction with frame of first class hard wood including providing and fixing internal lipping with second class teak wood battens 25mm minimum depth on all edges of shutter etc.,complete all as per drawings and as directed.
Providing and fixing factory made UPVC white colour sliding or openable glazed window upto 1.65 m in height dimension comprising of uPVC multi-chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mmthick galvanized mild steel section made from roll forming process of requiredlength (shape & size according to uPVC profile), appropriate dimension of uPVCextruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile,zinc alloy (white powder coated) touch locks with hook, zinc alloy body with singlenylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm sizefor fixing frame to finished wall and necessary stainless steel screws etc. Profileof frame & sash shall be mitred cut and fusion welded at all corners, includingdrilling of holes for fixing hardware's and drainage of water etc. After fixing framethe gap between frame and adjacent finished wall shall be filled with weather proofsilicon sealent over backer rod of required size and of approved quality, all completeas per approved drawing & direction of Engineer-in-Charge. (Single / double glasspanes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance indimension i.e. in depth & width of profile shall be acceptable. Variation inprofile dimension in higher side shall be accepted but no extra payment onthis account shall be made
Three track three panels sliding window made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.
Providing and fixing glazing in upvc door, window, ventilator shuttersand partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the Architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Supplying, fabricating and fixing of M.S. Grills to windows & ventilators frames using MS flats, square rods all as per design etc., complete with a shop coat of primer.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat . Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels conforming to IS: 14856 including fixing to frames.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : a) For fixed portion. i) Powder coated aluminium (minimum thickness of powder coating 50 micron):
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) a) Powder coated aluminium (minimum thickness of powder coating 50 micron).
Providing and Fixing factory made uPVC door frame, made of uPVC exturded sections, of size 65 mm x 55 mm with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be mitred cut and jointed with plastic brackets and stainless steel screws, reinforcing hinge side vertical of the frames with PVC profile of Size 28 mm x 30 mm having wall thickness 2 mm (±0.2 mm), including providing & fixing 3 nos of 125 mm long stainless steel hinges to the frame, fixing the frame with jamb with required number & size of anchor dash fastners, all complete as per manufacturer's specification and direction of Engineer-in-charge.
35 mm thick factory made Solid panel UPVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer's specification and direction of Engineer-in-charge
Decorative finish (wood grained finish)
Designing, fabricating, testing, protection, installing and fixing glass 6 to 12mm thickness in positionsemi (grid) unitized system of structural glazing (with open joints) for linearas well as curvilinear portions of the building for all heights and all levels,including: (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passedthe proof test at 1.5 times design wind pressure without any failure), ludingfunctional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws,toggles, nuts, bolts, clamps etc., structural and weather silicone sealants,flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gasketsfor water tightness, pressure qualisation & drainage and protection againstfire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminiumalloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steelframework of building structure using stainless steel anchor fasteners/ bolts,nylon seperator to prevent bimetallic contacts with nuts and washers etc. ofstainless steel grade 316, of the required capacity and in required numbers.
(c) Providing and filling, two part pump filled, structural silicone sealant andone part weather silicone sealant compatible with the structural silicone sealantof required bite size in a clean and controlled factory / work shop environment,including double sided spacer tape, setting blocks and backer rod, all ofapproved grade, brand and manufacture, as per the approved sealant design,within and all around the perimeter for holding glass. (d) Providing and fixing in position flashings of solid aluminium sheet 1 mmthick and of sizes, shapes and profiles, as required as per the site conditions,to seal the gap between the building structure and all its interfaces with curtainglazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazingsystem to make it watertight, by incorporating principles of pressure equalization,providing suitable gutter profiles at bottom (if required), making necessary holesof required sizes and of required numbers etc. complete.
This item includes costof all inputs of designing, labour for fabricating and installation of aluminiumgrid, installation of glazed units, T&P, scaffolding and other incidental chargesincluding wastages etc., enabling temporary structures and services, cranes orcradles etc. as described above and as specified. The item includes the cost ofgetting all the structural and functional design including shop drawings checkedby a structural designer, dully approved by Engineer-in-charge. The item alsoincludes the cost of all mock ups at site, cost of all samples of the individualcomponents for testing in an approved laboratory, field tests on the assembledworking structural glazing as specified, cleaning and protection till the handingover of the building for occupation. In the end, the Contractor shall provide awater tight structural glazing having all the performance characteristics etc. allcomplete as required, as per the Architectural drawings, as per item description,as specified, as per the approved shop drawings and as directed by the Engineerin-Charge.
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pato +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1to 200 mVhr2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testingmethod for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testingmethod for a range upto 2000 ml4. Structural Performance Deflection and deformation by static air pressuretest (1.5 times design wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing methodfor Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi)upto 2000 ml
Providing and fixing 12 mm thick toughened glass door with shutter ofapproved brand and manufacture, including providing and fixing top & bottompivot & double acting hydraulic floor spring type fixing arrangement and makingnecessary holes etc. for fixing required door fittings with all accessores, all complete as per directionof Engineer-in-charge
Providing and fixing 12 mm thick toughened glass of approved brand and manufacture, fixing arrangement and making necessary holes etc. for fixing , all complete as per direction of Engineer-in-charge
Providing and fixing 8 mm thick toughened glass of approved brand and manufacture, fixing arrangement and making necessary holes etc. for fixing , all complete as per direction of Engineer-in-charge
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing the following hardware fittings of approved make.
Aluminium Handles, powder coated, ISI marked to required colour or shade with necessary screws etc., complete.
125mm long handles.
Powder coated ISI marked tower Bolt to required colour or shade with necessary screws etc., complete.for following sizes.
Aluminium hanging floor Door Stopper ISI marked powder coated to required colour or shade with necessary screws etc., complete.
Twin rubber stopper
Providing & fixing Aldrop with 16mm dia rod, required colour or shade with necessary screws etc., complete.
300mm long
250mm long
Providing and fixing aluminium die cast body tubular type universal hydraulicdoor closer (having brand logo with ISI, IS : 3564, embossed on the body, doorweight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete
SUB HEAD - IX : ROOF / WATER PROOFING WORK:
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:
a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.
d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/ sqm).
a) For Raft waterproofing
Providing and applying 2mm thick synthetic membrane of plasticised PVC manufactured by approved make. The PVC membrane system shall be compartmentalized to 150sqm maximum by surface waterbars as per approved design and each compartment shall be installed with 5 nos of injection flanges terminated in a junction box. The material shall have High mechanical resistance, Resistance to wash-out waters action, Resistance to roots, Resistance to bursting. Complete shop drawings required for implementation of the work should be submitted before execution. Service guarantee shall be given for a period of 5(five) years from the date of completion. Any defects in waterproofing including damages occured to other items due to the defective water proofing treatment during the service/ guarantee period shall be rectified satisfactorily immediately at the risk and cost of the contractor. Makes:- SIKA or Equivalent.
The treatment shall be carried as per the following procedure:
Providing & applying Sikaplan® W Felt h PP 300 polyproyplene based geotextile 300g/m2 made of non-woven polypropylene geotextile below 2mm Thick PVC membrane as protection layer laid in dry conditions with approx. 100/150 mm overlap of the edges. The geotextile fabric shall protect the membrane from puncturing against sharp particles. PP Geotextile should have Tensile Strength 15 (-1.5) kN/m (acc EN 10319), Elongation 50 (- 15) % (acc EN 10319), Thickness 2.3 (-0.23) mm (acc EN ISO 9863-1) and Characteristic opening size O95 106 (+32) µm (acc EN ISO 12956) according to specification.
Providing and applying 2mm thick synthetic PVC twin colour geo-membrane Sikaplan PVC manufactured by ISO 9001 and ISO 14001 certified company made only from original raw material (no external recyclate) without DEHP (DOP)-plasticizer. The membrane shall have signal layer of 0.6mm of different colour to give a visual indication of when damage occurs as approved by Engineer. Overlaps min. 80mm heat welded with electr. Welding machine, incl. Seam treatment, testing of welded seams as per suppliers recommendations including installation by fastener with PVC discs from the same manufacturer. PVC membrane should have an elongation at break of ≥300% (acc ISO R 527 – 1/3/5 (DIN 16726-5.6 / EN 12311-2, ASTM D 638) with no minus tolerance), a burst strength of ≥ 50% (acc EN 14151, D=1.0m/Multi-Axial-Elongation), Tensile strength ≥ 15 N/mm2 (acc ISO 527-1/3/5 (DIN 16726-5.6/ EN 12311-2, ASTM D 638) and Elastic modulus E1-2 (Material Flexibility) ≤ 20 N/mm2 (acc ISO 527-1/3/5 (DIN 16726-5.6) according to specification. The material shallhave high mechanical resistance,resistance to wash out waters action,resistance to low temperatures,root resistance, resistance to bursting. Makes :- SIKA/ equivalent .
Providing and applying Sika® Waterbar h WP AF 28 PVC waterbar from virgin raw material only, welded onto the waterproofing membrane, min. 280mm wide, with minimum 4 anchors and min 30mm high to form compatments within the waterproofing system to prevent uncontrolled spread of possible leakage. PVC waterbar should conforms to BS 903, 2571, DIN 18541, part-1; tensile strength ≥ 10N/mm2; tear strength ≥ 12 N/mm; elongation at break ≥ 250 % and shore A hardness: 70 ± 5.
Providing and applying of injections flanges, Sikaplan WP Control Socket 5 pcs per compartment, incl. PU pipe resistant to 10bar pressure and incl. termination box at walls according to the specification from the same manufacturer as the waterproofing membrane.
Providing and applying Sikaplan® W Felt h PP 300 polyproyplene based geotextile 300g/m2 made of non-woven polypropylene geotextile above PVC membrane as protection layer laid in dry conditions with approx. 100/150 mm overlap of the edges. The geotextile fabric shall protect the membrane from puncturing against sharp particles. PP Geotextile should have Tensile Strength 15 (-1.5) kN/m (acc EN 10319), Elongation 50 (- 15) % (acc EN 10319), Thickness 2.3 (-0.23) mm (acc EN ISO 9863-1) and Characteristic opening size O95 106 (+32) µm (acc EN ISO 12956) according to specification.
Providing and applying protection concrete screed in PCC M-15 admixed with integral waterproofing compound Sika® Plastocrete Plus confirming to IS 2645 at the rate of 0.10 kg per bag of cement over the already laid membrane as separation layer. The thickness of screed shall not be less than 50mm. (Screed shall be measured and paid seperately)
(complete shop drawings required for implementation of the work should be submitted before execution. The waterproofing materials shall be from a single manufacturer long-term engaged in manufacturing waterproofing having an expertise record of at least 20 years in substructure waterproofing. All components and elements, which are needed to make the structure watertight, shall be proven to work together. There shall be a single source of responsibility and performance of the products. Specifically products to be welded together like membranes, waterbars, flanges, disk, pvc intergrated fleece tape shall be from same manufacturer. In no case these components shall be from any third party supplier than approved make of waterproofing. The manufacturer shall confirm full and proven compatibility of the entire waterproofing system in writing. Service guarantee shall be given by the authorised specialised installation agency for a period of 5(five) years from the date of completion. Any defects in waterproofing including damages occured to other items due to the defective water proofing treatment during the service/ guarantee period shall be rectified satisfactorily immediately at the risk and cost of the contractor).
b) For retaining wall waterproofing
Providing and applying 2mm thick synthetic membrane of plasticised PVC manufactured by approved make. The PVC membrane system shall be compartmentalized to 75 sqm maximum by surface waterbars as per approved design and each compartment shall be installed with 5 nos of injection flanges terminated in a junction box. The material shall have High mechanical resistance, Resistance to wash-out waters action, Resistance to roots, Resistance to bursting. Complete shop drawings required for implementation of the work should be submitted before execution. Service guarantee shall be given for a period of 5(five) years from the date of completion. Any defects in waterproofing including damages occured to other items due to the defective water proofing treatment during the service/ guarantee period shall be rectified satisfactorily immediately at the risk and cost of the contractor. Makes:- SIKA or equivalent.
The treatment shall be carried as per the following procedure:
Providing and applying Sika® Waterbar h WP AF 28 PVC waterbar from virgin raw material only, fixing with inner face of shutter, min. 280mm wide, with minimum 4 anchors and min 30mm high to form compatments within the waterproofing system to prevent uncontrolled spread of possible leakage. PVC waterbar should conforms to BS 903, 2571, DIN 18541, part-1; tensile strength ≥ 10N/mm2; tear strength ≥ 12 N/mm; elongation at break ≥ 250 % and shore A hardness: 70 ± 5.
Providing and applying Sikaplan® W Felt h PP 300 polyproyplene based geotextile 300g/m2 made of non-woven polypropylene geotextile on the external face of vertical wall as protection layer laid in dry conditions with approx. 100/150 mm overlap of the edges. The geotextile fabric shall protect the membrane from puncturing against sharp particles. PP Geotextile should have Tensile Strength 15 (-1.5) kN/m (acc EN 10319), Elongation 50 (- 15) % (acc EN 10319), Thickness 2.3 (-0.23) mm (acc EN ISO 9863-1) and Characteristic opening size O95 106 (+32) µm (acc EN ISO 12956) according to specification.
Providing and applying Sika® PVC disc post-applied connection of the waterproofing membrane to the conctrete structrure for open-cut excavations by PVC discs from the same manufacturer as the waterproofing membrane
Providing and applying of injections flanges, Sikaplan WP Control Socket 5 pcs per compartment, incl. PU pipe resistant to 10bar pressure and incl. termination box at walls according to the specification from the same manufacturer as the waterproofing membrane.
Providing and applying 2mm thick synthetic PVC twin colour geo-membrane Sikaplan PVC manufactured by ISO 9001 and ISO 14001 certified company made only from original raw material (no external recyclate) without DEHP (DOP)-plasticizer. The membrane shall have signal layer of 0.6mm of different colour to give a visual indication of when damage occurs as approved by Engineer. Overlaps min. 80mm heat welded with electr. Welding machine, incl. Seam treatment, testing of welded seams as per suppliers recommendations including installation by fastener with PVC discs from the same manufacturer. PVC membrane should have an elongation at break of ≥300% (acc ISO R 527 – 1/3/5 (DIN 16726-5.6 / EN 12311-2, ASTM D 638) with no minus tolerance), a burst strength of ≥ 50% (acc EN 14151, D=1.0m/Multi-Axial-Elongation), Tensile strength ≥ 15 N/mm2 (acc ISO 527-1/3/5 (DIN 16726-5.6/ EN 12311-2, ASTM D 638) and Elastic modulus E1-2 (Material Flexibility) ≤ 20 N/mm2 (acc ISO 527-1/3/5 (DIN 16726-5.6) according to specification. The material shallhave high mechanical resistance,resistance to wash out waters action,resistance to low temperatures,root resistance, resistance to bursting. Makes :- SIKA/ equivalent .
Providing & applying Sikaplan® W Felt h PP 300 polyproyplene based geotextile 300g/m2 made of non-woven polypropylene geotextile above PVC membrane as protection layer laid in dry conditions with approx. 100/150 mm overlap of the edges. The geotextile fabric shall protect the membrane from puncturing against sharp particles. PP Geotextile should have Tensile Strength 15 (-1.5) kN/m (acc EN 10319), Elongation 50 (- 15) % (acc EN 10319), Thickness 2.3 (-0.23) mm (acc EN ISO 9863-1) and Characteristic opening size O95 106 (+32) µm (acc EN ISO 12956) according to specification.
Providing and applying high density polyethyelene(HDPE) dimpled sheet Sikadrain 500 before backfilling. The dimpled sheet should have the following technical properties:- weight: 500-550 gsm ,Dimple Height: Minimum 8mm , with factory inbuilt geo fabric protection, Compressive strength :>200 KN/m2 , Flow rate per m-width @ 1% gradient, 200 kPa pressure (ASTM D 4716) : 60 Lit/min , Grab tensile strength(ASTM D 4632): 400 N Tear strength(ASTM D 4533):150 N, Resistance to Impact : No permeability at 250mm(DIN EN 12691), Air gap between dimples :>2 l/m2 The apllication shall be undertaken by the Specialised agency approved by Waterproofing Manufacturer.
(complete shop drawings required for implementation of the work should be submitted before execution. The waterproofing materials shall be from a single manufacturer long-term engaged in manufacturing waterproofing having an expertise record of at least 20 years in substructure waterproofing. All components and elements, which are needed to make the structure watertight, shall be proven to work together. There shall be a single source of responsibility and performance of the products. Specifically products to be welded together like membranes, waterbars, flanges, disk, pvc intergrated fleece tape shall be from same manufacturer. In no case these components shall be from any third party supplier than approved make of waterproofing. The manufacturer shall confirm full and proven compatibility of the entire waterproofing system in writing. Service guarantee shall be given by the authorised specialised installation agency for a period of 5(five) years from the date of completion. Any defects in waterproofing including damages occured to other items due to the defective water proofing treatment during the service/ guarantee period shall be rectified satisfactorily immediately at the risk and cost of the contractor).
© Termination of membrane system
Providing and applying Sika® Dilatec E-220 PVC tape with integrated fleece termination using Sikadur®-31 C epoxy based membrane adhesive @1.4 kg/sqm as base coat & top coat capable of bonding fleece and concrete together. Both tape and epoxy shall be of the same manufacturer as the waterproofing membrane . The integrated fleece should have Tensile strength ≥ 10 N /mm2 (acc. EN ISO 527-1), Elongation at break ≥ 300% (acc. EN ISO 527-1), Water vapour Diffusion Resistant ~17.000 (acc.to SIA V280), Root resistance compliant (acc.to SIA V280), Water tightness 10 bar (acc.to EN 1928/B), Impact Resistance Watertight at a drop ht > 650mm (acc.to SIA V280), Ozone resistance compliant (acc.to SIA V280) and the epoxy based membrane adhesive should have mixed density - 1.75 kg/ltr & bond strength > 1.5 N/mm2.
All Construction Joints waterproofing
(i) Providing & installing a re-injectable hose SikaFuko®VT1+Accessories in all construction joints with unique integral ‘valve’ system including all accessories and installation, testing etc. The hose should be approved as per MPA NRW: P-22-MPANRW-2368/2 - German Approval for use in construction joints .WISSBAU: Tested for use in construction joints. Re-injectable hose should have Inner diameter ≥ 6mm, 4 (four) opening channels for injection in four directions, Shore A Hardness :Yellow inner core: 85 +/- 3 (DIN EN ISO 868), Yellow profile strips:20 +/- 5 (DIN EN ISO 868), Elongation at Break :Yellow inner core: ≥250% (DIN EN ISO 527), Yellow profile strips:≥ 300% (DIN EN ISO 527), Mesh:≥ 30% % (DIN EN ISO 527). Tensile Strength : Yellow inner core: ≥ 14 N/mm2 (DIN EN ISO 527), Yellow profile strips:≥ 3 N/mm2 (DIN EN ISO 527), Mesh:≥ 30 N (DIN EN ISO 527). Complete system makes:- SIKA / BASF or approved equivalent.
Injection system for re-injectable hose system and for Compartment on horizontal and Vertical (only in case of a future water leak if detected)
(i) Providing and injecting Sika®Injection-306 a 3 part, very low viscous, elastic polyacrylic injection resin with a versatile and adjustable reaction time having the following properties:Mixed viscosity : 3-11 M.pa.s at +20 Deg C, Reaction time : adjustable according to ambient temperatrure and execution requirement between 8-50 mins, pH – 9-10, Tested as per Wissbau No. 2002-094-(1A) – Function test with re-injectible hose system. Complete system makes:- SIKA / BASF or approved equivalent.
Providing and fixing PVC rain water down take pipe of 6kg/cm2 pressure or grade etc.,including necessary fittings like clamps, bends, shoes and adhesives etc., complete all as directed.
a) 110 mm dia
b) 160mm dia
SUB HEAD - X : MISCELLANEOUS ( WOODEN CLADDING & WOODEN CEILING)
Providing and fixing standard pattarn paneling consisting of aluminium section framing panel of 600 c/c horizontally and vertically with vertical members (50x25x1.5mm thick 1200 c/c and 50x50x1.5mm thick 1200 c/c alternatively), having 12mm thick MDF board paneling fixing with black machine screw, provided with rubber/teak wood beading whereever required all exposed edges etc over MDF board over 1mm thick aluminium sheet of approved make etc all complete.
Over RCC/Brick wall
Over RCC ceiling
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c,
including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :(Make : Gproc , L Strong , Armstrong)
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS Certification marks)(Make : Gproc , L Strong , Armstrong)
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.
Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.(a)12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
SUB HEAD - XI : SANITARY INSTALLATIONS WORK:
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid. (Make : Jaquar or equivalent)
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern (Make : Jaquar or equivalent)
Providing and fixing toilet paper holder : C.P. brass
Providing and Fixing Health Faucet JAQUAR Cat. No. 573 (ALLIED SERIES) or equivalent make KINGSTON-AGR ACS 49/KOHLER Cat. No. 12925IN-CP (HEALTH FAUCET W/WHITE SDSPRAY, M HOSE) with flexible pipe and wall hook with each European W.C. Pan.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
Providing,fitting and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing counter top Wash Basin with C.I. brackets, 15 mm C.P. brass pillar taps, including painting of fittings and brackets, cutting and making good the walls wherever require: (Make : Jaquar or equivalent)
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing PTMT Bottle Trap for Wash basin and sink.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Rectangular
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
510x1040 mm bowl depth 250 mm
Providing & fixing sqare mouth S W Gully trap grade A complete with CI grating brick machinery chamber with water tight C I cover with frame of 300x300 mm (Size inside ) The weight of cover to be not less than 4.5 kg & frame to be not less than 2.70 kg as per standard design.
100x100 mm size P type.
Supplying, laying, jointing, testing and commissioning; UPVC(SWR) pipe (Type-B) as per IS : 13592/1992 including specials of best quality and approved make fixed to wall/floor including chasing, cutting, making the hole in walls/floors, cutting the pipes to the required size of length jointing the pipes and specials with suitable resin and testing etc.,complete all as specified and directed. (Specials at junctions must have access doors wherever required.)
75 mm dia
110 mm dia
150mm dia
Providing and fixing PVC 75mm size Nahani Trap of approved make (Supreme) conforming to ISI Specifications and construction of Cistern in CC 1:2:4 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot)
Providing and fixing 15 mm nominal bore C.P. brass short body bib cock of approved quality conforming to IS : 8931 (Item Details:-Make :- Jaquar / equivalent)
SUB HEAD - XII : WATER SUPPLY SERVICES
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
Supplying and fixing in position best quality and approved make heavy quality screws down gun metal gate valves with hand wheel of the following sizes fixed to service lines including testing, making good the leakages, if any etc.,
Providing & Fixing HDPE O.H water storage tanks of the approved quality, & of the following capacity including making solid supported base as per instructions & doing all connections as required to make the work complete in all respects.
1000 lit. capacity
SUBHEAD -XIII :SEWAGE DISPOSAL SYSTEM:
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. (a) All kinds of soil.
Excavating trenches of required width for pipes etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
80 mm dia. but not exceeding 300 mm dia
Providing and laying 150 mm diametre S.W. pipe including cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks of 50 class designation in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
Inside dimensions 455x610 mm and 45 cm deep for single pipe line :
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).
All works upto plinth level.
Add / Deduct for using extra cement in the items of design mix over and above the specified cement content therein.
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. a)Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for:
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform.
Providing of 6mm cement plaster of mix in all surface with: (a) cement mortar 1:3 (1 cement : 3 fine sand) at all levels.
Providing of 12 mm cement plaster of mix in all surface with (a) cement mortar 1:6 (1 cement : 6 fine sand) at all levels.
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. a) 20 mm cement plaster
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.
Making soak pit 2.5 diameter 3.0 meter deep with 45 x 45 CM dry brick honey comb shaft with bricks of class designation 75 and S.W drain pipe 100mm diameter 1.8 m long complete as per standerd design
Providing Rain Water Harvesting of internal size 3000 x 3000 x 4000 deep with brick work with 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge including UPVC perforated pipe of 6kg/cm2 pressure or grade etc.,including necessary fittings complete filling with 600mm BRICK BALAST (HALF BURNT),over 400mm STONE GRIT SIZE 40mm over 200mm PEA GRAVEL over 150mm COARSE SAND with 100mm thick RCC slab cover & MS manhole cover of size 600mm x 600mm with frame on top of slab as per direction of Engineer-in-charge.
SUB HEAD - XIV : ROAD WORK:
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.
All kinds of soil
Supply of approved moorum obtained from outside MOD land filling in layers not exceeding 20cms thick at all heights and depths in foundations, pits, trenches, sewer lines around structures and foundation under floors other places including dressing and levelling watering, consolidation to achieve minimium of 95% proctor density etc., complete as per drawing specifications, payments shall be made for the quantity after deducting the voids.
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
Preparation of Subgrade
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge
Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler,cleaning and preparing the existing road surface as per specifications : (a) On W.M.M. @ 0.45 Kg I sqm.
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of Engineer-in-Charge.
50 mm average compacted thickness with bitumen of grade VG-30 @5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
Providing and laying non- pressure NP2 class RCC pipes with collars joints with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc., complete for culverts, road crossings of electric cables, water supply pipe line and telephone cable etc.,
150mm dia
300mm dia
450mm dia
600mm dia
SUB HEAD - XV : FURNITURE
Supply and placement of Executive table 2350x2350x750, Primary Work Surface: Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping., Modesty Panel: Made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top, Understructure: Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping. Panel Drawer Slides. Drawer extension is 325 MM. Drawers have a soft closing & anti slam mechanism. Handles are provided for ease of opening. Pedestal is provided with lock for security. (All dimensions tolerance will be +/- 10mm). Make Godrej /Wipro/Featherlite
Supply of Officer Chair high back revolving type with Synchro Mechanism and fitting and gas lift system, with PU arms with nylon base twin castor wheels with seat & back cushion with fabric of approved shade. Make Godrej /Wipro/Featherlite
Supply of visitor chair with revolving type with fitting/gas lift system, with P.U. arms with nylon base with castor wheels with seat and back cushions with fabric of approved shade. Make Godrej /Wipro/Featherlite
Supply of Single seater sofa made out of teakwood framework 25 x 50mm for the seat and back flat plastic newar strips for seat and back cladded with 100m thick high density foam for seat and 75mm thick for back, 12mm thick poly foam contouring with cotton lining cloth, upholstered with fabric of approved shade, armrest of 95 x 22mm wide of TW section and polished with melamine polish etc complete. Make Godrej /Wipro/Featherlite
Supply of 3 seater sofa in approved configuration of size 1850 x 750 x 700mm made out of teakwood frame work, seat and back with 2nd class hard wood , seat cushioned with 75mm thick high density foam and extra padding with 20mm thick foam for making shape on seat & back. Back with 50 mm thick high density foam duly upholstered with fabric of approved shade & quality all exposed wooden surface finished with Melamine polish etc. all complete. Make Godrej /Wipro/Featherlite
Supply of Corner Table 450 x 450 x 400 mm with frames and legs made out of 60 x 35 mm teakwood sections with 10 mm thick glass on top, top frame and legs polished in melamine finish etc., all complete as per drawing. Make Godrej /Wipro/Featherlite
Supply of Center Table 900 x 525 x 400 mm with frames and legs made out of 60 x 35 mm teakwood sections with 10 mm thick glass on top, top frame and legs polished in melamine finish etc., all complete as per drawing. Make Godrej /Wipro/Featherlite
Supply of Officer Table of size 1850 x 900 x 750 mm made out of 18mm plywood with 1 mm thick laminated of approved shade with four drawers and with front of 12mm thick with all exposed edges to have teakwood beading with melamine poilish finish and all internal surfaces with 0.8 mm laminate Make Godrej /Wipro/Featherlite
Supply and placement of high back chair, The seat is made up of 1.2 ± 0.1cm thk. hot pressed plywood measured as per QA method described in OCP-QLTA-PL14-18.The Back is made up of injectionmoulded glass filled nylon & upholstered using Net fabric with high tenacity BACK SIZE : 45.0 cm. x 65.3 cm. HIGH RESILIENCE POLYURETHANE FOAM: The HR polyurethane foam is moulded with density=55+/-2 kg/m³ and hardness 16 ± 2 kgf asper IS:7888 for 25% compression. The armrests have an Up-Down adjustment of 8.5 ± 0.5cm which is provided in armrest structure. Armrest Top has an integrated layer of Thermoplastic Elastomer(TPE). LUMBAR SUPPORT ASSEMBLY:The Lumbar support consists of polypropylene pad with moulded polyurethane foam & covered with polyester fabric. The Height of Lumbar pad can be adjusted through two projecting knobs provided on the rear side of the pad. Lumbar pad has an adjustment of 8.0 ± 0.5cm in height. TWIN WHEEL CASTORS:The twin wheel castors are injection moulded in black Nylon PEDESTAL ASSEMBLY: The pedestal is injection moulded in black 30% glass-filled Nylon and fitted with 5 nos. twin wheel castors.The pedestal pitch center dia is ∅66.1 ± 0.5cm (76.1 ± 1.0 cm. all specification are as per Bifma standard. Make Godrej /Wipro/Featherlite
Supply of WT series Table for PA of size 1800 x 900 x 750 mm and ERU 900 x 483 x 670 mm made out of wooden top, drawer Facia, side and modesty panels and drawer shell and square tube frames with 3 drawer unit on LHS and ERU on RHS. Make Godrej /Wipro/Featherlite
Supply of visitor chair with revolving type, synchro fit mechanism and cushions for seat and high back with upholstery of approved shade and casters etc., all complete as per drawing.Starr Mid Back Chairs of Make Godrej /Wipro/Featherlite
Supply of Discussion Table for 6 persons made out of 18mm Plywood with 3.5mm th vineer top to have PU Finish with Melamine Polish of approved shade of Senate Make Godrej /Wipro/Featherlite
Supply & fixing of modular works station for size 1200X1200 made out of 72 mm Aluminium profile with powder coating finish with 12 mm thick Pannal/Soft board/ writing Board with provision for sliding in partition and top to have 25mm thick board with 2mm thick edge banding tape of approved shade, with key board tray and CPU trolley complete of Reason model of Make Godrej /Wipro/Featherlite
Supply of Work Station Chairs with revolving type with P.U. arms with fittings gas left system with seat & back cushion of approved shade complete.Bravo Mid Back chairs Make Godrej /Wipro/Featherlite
Providing & fixing of display board / Writing Board made out of 12mm ply with writing board / fabric of approved shade. Make Godrej /Wipro/Featherlite
Supply of Work bench of size 1500 x 1200 x 1000 mm of table and top to have 600 x 300 mm shelf with providing 15/5 Ams power socket frame work made out of 18mm plywood with 1 mm thick laminate of approved shade table to have four draws with foot rest, all edges to have TW beading with locking arrangement complete with spirit polish. Make Godrej /Wipro/Featherlite
Supply of work bench chair with seat and back cushion with fabric of approved shade complete.PCH 4103 without arms Make Godrej /Wipro/Featherlite
Providing and fixing of conference table( U Shape Design) for 30 persons of 1200 mm wide and 750 mm height made out of 18mm thick plywood for frame work, shelf foot rest and front facia, provision to accommodate conduits for writing front, top and side end surfaces to have 3.5 mm thick approved shade veneer panelling, exposed edges of plywood covered with teakwood beading, exposed veneer of top shall be finished with PU polish of approved shade, ends and fronts veneered surface finished with mallamine polish, internal exposed surface of the table finished with laminate etc complete of Make Godrej /Wipro/Featherlite
Supply of conference chairs with medium back cushioned of 50mm rubber and fabric of approved shade all complete as per drawing Make Godrej /Wipro/Featherlite
Supply of chairs with P.U arms finish with seat and back with cushion of high density rubber foam for seat and back with fabric approved Make Godrej /Wipro/Featherlite
Supply and fixing of writing board of size 1800 x 1200 mm of Make Godrej /Wipro/Featherlite
Supply of Steel Storage rack of size 2000 x 900 x 450 mm made out of MS "C" Angle of 2mm thick with five panels of M.S. sheet of 14 guage with spray enamel paint complete.
Supply of Storewell of size 1918 x 916 x 486mm SLIMLINE 4S model overall dimensions 1950 mm H x 900 mm W x 507 mm D of Make Godrej /Wipro/Featherlite
Sliding Door Units of file cabinet of size 1200x750x450mm
Optimizer 1980H with TD6 457D
Supply of Cafeteria chairs of 450x450x860mm made out of teak wood frame work of 70x30mm section with 12mm ply wood with 50mm thick high density form for seat with approved shade of fabric with spirit polish
Supply and placement of Cafeteria table opf size 2100x1050x750mm made out of teak wood frame work and finishing with commercial board with melamine polish etc
Supply and placement of Working STOOLS of Height Adjustable Revolving Stool with back Brown leatherette of Make Godrej /Wipro/Featherlite
SUB HEAD - XVI : ARBORICULTURE / LANDSCAPING :
Supply of Grass and planting by dibbling the area including watering & Maintenance of Lawn for 30 days or more till grass forms a thick lawn cushion free from weeds. With Bermuda Grass (15 cm x 15 cm apart) INCLUDING ELEVEN MONTHS MAINTENANCE AFTER COMPLETION OF WORK
Trees:- Digging of pits of size 1x1x1m and refilling with good agriculture soil and well decomposed cattle manure in 4:1 ratio. Supply and planting of approved Tree species of healthy grownup saplings with good root system. Saplings should be of minimum 4 ft height from ground level after plantation. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, training, pruning, staking and spraying of insecticide and fungicide, INCLUDING ELEVEN MONTHS MAINTENANCE AFTER COMPLETION OF WORK.
Shrubs: Digging of pits of size 0.60x0.60x0.60m and refilling with good agriculture soil and well decomposed cattle manure in 3:1 ratio. Supply and planting of approved Shurbs species of healthy grownup saplings with good root system. Saplings should be of minimum 2 ft height from ground level after plantation. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, training, pruning, staking and spraying of insecticide and fungicide, INCLUDING ELEVEN MONTHS MAINTENANCE AFTER COMPLETION OF WORK.
Hedges: Digging of trenches of size 0.30 x 0.30m (width & depth) and refilling with good agriculture soil and cattle manure in 4:1 ratio. Maintenance includes, regular watering, de-weeding, loosening of soil fortnight, manuring with cattle manure and fertilizer, pruning, shaping and spraying of insecticide and fungicide, INCLUDING ONE YEAR MAINTENANCE AFTER COMPLETION OF WORK.
Flower Beds: Digging upto 0.10m refilling with good soil and cattle manure in 3:1 ratio. Preparation of beds supply and planting of healthy grown up plant material. Maintenance includes regular watering, de-weeding, manuring with manure and fertilizer.pruning, shaping and spraying of insecticide and fungicide, INCLUDING ELEVEN MONTHS MAINTENANCE AFTER COMPLETION OF WORK.
Potted Plants: Supply and maintaining the Indoor and Outdoor approvedpotted plants in a good healthy and disease free condition of various varieties and in 300-450 mm Dia.HDPE/PVC Plastic Pot. Height of plantt-3'-4'.
Clearing jungle including uprooting of trees and saplings of girth 30 cm to 50 cm and replanting of uprooting trees as per direction of Engineer - in - charge.
SUBHEAD-XVII : INTERNAL ELECTRIFICATION
Lights Points
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required
Group C
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 5/6 A modular switch, connections etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the modular plate switch box including connections, modular plate etc. as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and fixing 5 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.(AC sockets)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Light/Fan Fixtures
Supply of the following LED Light Fixtures with electronic driver , heat dissipating element including necessary accessories etc., complete on wall/ Ceiling / suspended from ceiling/ recess including all fixing accesssories such as leads,Teak wood round block, downrods, MS clamps, nuts, GI chain and bolts etc complete as required.
42W LED luminaire Recess Mounted 2ft x 2ft LED Luminaire with Diffuser similar to Philips Cat No: RC380B LED42S -6500 G4 L60 W60 PSD OD / Equivalent Make of Wipro.
40W LED luminaire Recess Mounted 2ft x 2ft LED Luminaire with Diffuser similar to Philips Cat No: SM365C LED32-6500 PSU OD WH / Equivalent Make of Wipro.
28W LED Luminaire Recess mounted circular square LED downlighter Philips Cat No:RC383B LED 28S-6500 PSU OD WH PIR / Equivalent Make of Wipro.
16W LED Luminaire Surface mounted circular square LED downlighter Philips Cat No:SM200C LED16S 6500 PSU OD WH / Equivalent Make of Wipro.
12W LED Luminaire surface mounted circular LED downlighter similar to Philips Cat No:SM250C LED12S- 6500 PSU WH / Equivalent Make of Wipro.
195W hight bay LED Luminaire Philips Cat No: BY325P LED195S CW PSU GR FG WB XTFCL V1,Equivalent Make of Wipro.
22W LED Tube Light similar to Philips Cat No:BN 021 LED25S 6500 PSU GR S1 / Equivalent Make of Wipro.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Ceiling Fans
Supply of 1200 mm sweep 5star rated Ceiling fan with standard down rod, all accessories Electrical connections. Including fixing materials as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Exhaust Fans
Supply of heavy duty Exhaust fans with Non Metallic blades following size sweep with gravity louvres shutters Exhaust fans with Metallic blades of following.
250 mm Sweep 900rpm
Supply of Exhaust fans with PVC blades following size sweep with gravity louvres shutters Exhaust fans of following
300mm Sweep 900rpm
Installation of exhaust fan in the existing opening, including making good the damage,connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)
8 way (4 +24), Double door
Supplying and fixing following rating, four pole, (three phaseand neutral), 415 V, residual current breaker with Overload (RCBO), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 A, Four Pole, RCBO, 30mA.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5A - 32A, Single pole, MCB, 10kA
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
8 way, Double door
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, RCBO having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25 A DP RCBO, 30mA
Supplying,installation,testing an d commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
SUBHEAD- XVIII : POWER WIRING
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
4 way (4 + 12), Double door vertical type, 415 V, TPN MCB
Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 A FP MCB, 10kA
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Three Pole, 32A , 415 V, 10KA, MCB
Three Pole, 40A , 415 V, 10KA, MCB
Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current breaker with Overload (RCBO), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 A, Four Pole, RCBO, 100mA.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5A - 32A, Single pole, MCB, 10kA
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 6 sq. mm earth wire
SUBHEAD- XIX : UPS WIRING
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holesin cubicle panel, making connections, etc. as required
250 A, 25 KA,TPMCCB
Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current breaker with Overload (RCBO), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
63 A, Four Pole, RCBO, 100mA.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5A - 32A, Single pole, MCB, 10kA
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 16 sq. mm + 2 X 16 sq. mm earth wire
SUBHEAD-XX : SHOP ELECTRICS
ELCTRICAL PANEL
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA/Galvanised steel enclosure for main frame and 1.6mm thick partitions and shall have IK Certification as per IEC 62262 for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.The panel shall be got fabricated from manufacturers as per IEC 61439(Part-1&2). Indoor panels shall have IP-4X degree of protection and outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose.
GROUND FLOOR MAIN PANEL
INCOMER
ACB, with Electrically Draw out with 2000Amps, 50kA, FP,. - 1 SET
Incomer shall have one set of the following items:
0 - 500V Digital Volt meter - 1No.
0 - 1000A Digital Ammeter- 1 No.
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 1 class and control circuit wiring with MCBs - 1 No.
1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
BUS BAR
FP Alluminium busbar of 800A with 50 KA fault level capacity, mounted on non-hygroscopic, glass fibre reinforced insulators-1Set
OUTGOINGS
800A, 50KA FP EDO type draw out ACB (Microprocesssor release)- 1Nos
200A, 25KA FP MCCB (Microprocesssor release)- 2No
100A, 25KA FP MCCB (Microprocesssor release)- 3Nos
63A, 16KA FP MCCB (Microprocesssor release)- 3Nos
40A, 16KA FP MCCB (Microprocesssor release)- 3Nos
32A, 25KA FP MCCB with TVSS - 1set
1 Lot of control wiring.1 Set of designation plates.
Two numbers 50mm X 6mm GI earthing terminals - one on each side of the panel with earth strip run inside the panel
FIRST FLOOR MAIN PANEL
INCOMER
MCCB, with Microprocesssor based release 250Amps, 36kA, FP,. - 1 SET
Incomer shall have one set of the following items:
0 - 500V Digital Volt meter - 1No.
0 - 250A Digital Ammeter- 1 No.
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 0.5 class and control circuit wiring with MCBs - 1 No.
1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
BUS BAR
FP Alluminium busbar of 250A with 50 KA fault level capacity, mounted on non-hygroscopic, glass fibre reinforced insulators-1Set
OUTGOINGS
63A, 16KA FP MCCB (Microprocesssor release)- 4Nos
40A, 16KA FP MCCB (Microprocesssor release)- 5Nos
32A, 25KA FP MCCB with TVSS - 1set
1 Lot of control wiring.1 Set of designation plates.
Two numbers 50mm X 6mm GI earthing terminals - one on each side of the panel with earth strip run inside the panel
HVAC PANEL
INCOMER
MCCB, with Microprocesssor based release 630Amps, 50kA, FP,. - 1 SET
Incomer shall have one set of the following items:
0 - 500V Digital Volt meter - 1No.
0 - 630A Digital Ammeter- 1 No.
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 1 class and control circuit wiring with MCBs - 1 No.
1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
BUS BAR
FP Alluminium busbar of 250A with 36 KA fault level capacity, mounted on non-hygroscopic, glass fibre reinforced insulators-1Set
OUTGOINGS
320A, 36KA FP MCCB (Microprocesssor release)- 1Nos
250A, 36KA FP MCCB (Microprocesssor release)- 2Nos
160A, 25KA FP MCCB (Microprocesssor release)- 1No
32A, 25KA FP MCCB with TVSS - 1set
1 Lot of control wiring.1 Set of designation plates.
Two numbers 50mm X 6mm GI earthing terminals - one on each side of the panel with earth strip run inside the panel
UPS PANEL
INCOMER
MCCB, with Microprocesssor based release 250Amps, 36kA, FP,. - 1 SET
Incomer shall have one set of the following items:
0 - 500V Digital Volt meter - 1No.
0 - 250A Digital Ammeter- 1 No.
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 1 class and control circuit wiring with MCBs - 1 No.
1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
BUS BAR
FP Alluminium busbar of 250A with 36 KA fault level capacity, mounted on non-hygroscopic, glass fibre reinforced insulators-1Set
OUTGOINGS
63A, 16KA FP MCCB(Microprocesssor release)- 5Nos
40A, 16KA FP MCCB (Microprocesssor release)- 4Nos
32A, 25KA FP MCCB with TVSS - 1set
1 Lot of control wiring.1 Set of designation plates.
Two numbers 50mm X 6mm GI earthing terminals - one on each side of the panel with earth strip run inside the panel
Providing and fixing Cubical panel borad with following rating and breaking capacity of MCCB/ACB with Microprocessor based release and Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 1 class and control circuit wiring with MCBs - 1 No. and 1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
800A, 50KA FP EDO type draw out ACB
400 A, 36 KA,FPMCCB
200 A, 25 KA,FPMCCB
100 A, 25 KA,FPMCCB
Supply of following size 1.1KVgrade XLPE insulated armoured aluminium conductor underground cable, The cable shall conform to IS 7098 Part-1.
3.5C X 300 Sq.mm Aluminium
3.5C X 240 Sq.mm Aluminium
3.5C X 185 Sq.mm Aluminium
3.5C X150 Sq.mm Aluminium
3.5C X 95 Sq.mm Aluminium
3.5C X 70 Sq.mm Aluminium
4C X 16 Sq.mm Aluminium
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required.
Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE/ copper conductor cable of 1.1 kV grade as required.
3½ X 300 sq. mm (70 mm)
3½ X 240 sq. mm (62 mm)
3½ X 185 sq. mm (57 mm)
3½ X 150 sq. mm (50 mm)
3½ X 95 sq. mm (45 mm)
3½ X 70 sq. mm (38 mm)
4 X 16 sq. mm (28mm)
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm Copper strip on surface or in recess for connections etc. as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
400 mm width X 50 mm depth X 2.0 mm thickness
200 mm width X 50 mm depth X 1.6 mm thickness
150 mm width X 50 mm depth X 1.6 mm thickness
SUBHEAD- XXI : TELEPHONE/LAN CONDUTING
Supply and laying of 25mm dia. Medium class PVC conduit concealed in wall/ ceiling/floor including all accessories such as junction boxes, conduit bends, etc completed as required for Telephone & Lan etc.,
Supply and laying of 25mm dia. Medium class PVC conduit With GI WIRE concealed in wall/ ceiling/floor including all accessories such as junction boxes, conduit bends, etc completed as required for Telephone & Lan etc.,
Supply and fixing of Telephone outlet (RJ11) with anodised GI box with front plate and plug in type telephone socket .
Supply and installation of the following Krone connectors in junction box complete as required.
a)20 pair
Supply and laying of 2pair 0.5mm dia PVC insulated Copper conductor Telephone wire conforming to DOT Specification
Supply and fixing of LAN outlet (RJ48) with anodised GI box with front plate and plug in type LAN socket .
SUB HEAD-XXII : SPECIAL EARTHING
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosurewith cover plate having locking arrangement and watering pipeof 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm Copper strip on surface or in recess with DMC Insulated Supports for connections etc. as required. Metre
Providing and fixing 25 mm X 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
SUB HEAD- XXIII : LIGHTNING PROTECTION SYSTEM
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Supply and laying of following size strips including all necessary inter connections between earth station and equipment. supports for strips as applicable .
32 X 5mm Aluminium strip with DMC Insulated Supports
50 X5mm GI strip laid in ground
Supply and installation of vertical air termination with 40 mm dia copper hollow sphere with spikes, fixed on 1000mm length 25mm dia Copper tube including all fixing accessories..
Supply and installation of Test link fuse as required complete set
SUBHEAD-XXIV: EXTERNAL POWER SUPPLY:
11KV 800A 25KA EDO 3P VCB indoor type with Digital Voltmeter with PT, digital Ammeter with CTs, Digital PF Meter, Digital load manager, Overload & Earth Fault relays of Numerical type, Phase Indication Lamps, Breaker On/ Off/ Trip and Spring Charge, and Trip Circuit healthy Indications along with builtin power pack suitable for 2 `ON' & 2 `OFF' operations – 1set
Supply,Fabrication and Errection of DP Structure wich includes 200 x100mm RS Joists 2Nos and 100 x50mm ISMC along with Hardware and painting. 11KV AB Switch, LAS, Panther Conductor with Al Clamps and connectors as per Standed
11KV 800A 25KA EDO 3P VCB Outdoor type with Digital Voltmeter with PT, digital Ammeter with CTs, Digital PF Meter, Digital load manager, Overload & Earth Fault relays of Numerical type, Phase Indication Lamps, Breaker On/ Off/ Trip and Spring Charge, and Trip Circuit healthy Indications along with builtin power pack suitable for 2 `ON' & 2 `OFF' operations – 1set
Supply, erection, testing and commissioning of Metering cubicle with ERDA tested CTs and PTs complete with NABL Testing. (Supply & Erection of 11KV outdoor type CT, 15VA Burden 0.5CL, 50/1A and Supply & Erection of 11KV outdoor type PT, 50VA Burden 0.5CL)-Ioutdoor panel
supply, installation, testing and commissioning at site 11 KV/433V, 3 phase, 50 Hz z=6.25%, delta/star connected, outdoor type 1000KVA transformers, oil immersed ONAN cooled, complete with all fittings such as oil conservator, silica gel breather, thermometer, explosion vent, Local ON LOAD tap changer with AVR , diagram & rating pkte, oil temperature indicator, winding temperature indicator and buccholtz relay with wiring upto marshalling box, lifting lugs, first filling of oil, weather proof HT cable box, LT Cable box etc. complete as per specification Make: ABB/schneider/crompton greaves.
Supply and commissioning of following size 11KV (E) grade XLPE insulated armoured aluminium conductor under ground cable, The cable shall conform to IS 7098/ Part I.
3C X 185 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Above 120 sq. mm and upto 400 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/HUME/ METAL pipe as required.
Above 120 sq. mm and upto 400 sq. mm
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :
3C X 185 sq.mm
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA/Galvanised steel enclosure for main frame and 1.6mm thick partitions and shall have IK Certification as per IEC 62262 for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.The panel shall be got fabricated from manufacturers as per IEC 61439(Part-1&2). Indoor panels shall have IP-4X degree of protection and outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose.
MAIN PCC PANEL
EB & DG INCOMERS
ACB, with Electrically Draw out with O/C,S/C,E/F 2000Amps, 50kA, FP,. - 2 SET
Incomer shall have one set of the following items:
0 - 500V Digital Volt meter - 2 Nos.
0 - 2000A Digital Ammeter- 2 Nos.
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc with and LED display with Core Balance CTs of ratio 2000/1A Class 1Accuracy and 10VA burden and control circuit wiring with MCBs - 2 No.
Core Balance CTs of ratio 2000/1A Class 1 Accuracy and 10VA burden for Referal –2 sets.
Core Balance CTs of ratio 2000/1A Class 1 Accuracy and 10VA burden for APFCR panel –1 set.
1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
BUS BAR
FP Alluminium busbar of 2000A with 50 KA fault level capacity, mounted on non-hygroscopic, glass fibre reinforced insulators-1Set
Change Over Switch
2000A 50KA 4P Motorized Chage Over set-1 No
OUTGOINGS
800A, 50KA FP MCCB (Microprocesssor release) 1Nos
630A, 50KA FP MCCB (Microprocesssor release)- 3Nos
400A, 50KA FP MCCB (Microprocesssor release)- 2Nos
200A, 16KA FP MCCB (Microprocesssor release)- 2Nos
63A, 16KA FP MCCB (Microprocesssor release)- 2Nos
125A, 25KA FP MCCB (Microprocesssor release) with 50 KVAR Fixed capcitor - 1Nos
32A, 25KA FP MCCB with TVSS - 1set
Intelligent multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 1 class and control circuit wiring with MCBs - 11 Nos.
1 Lot of control wiring.1 Set of designation plates.
Two numbers 50mm X 6mm GI earthing terminals - one on each side of the panel with earth strip run inside the panel
APFC PANEL
INCOMER
MCCB, with Microprocesssor based release 630Amps, 50kA, FP,. - 1 SET
Incomer shall have one set of the following items:
0 - 500V Digital Volt meter - 1No.
0 - 630A Digital Ammeter- 1 No.
Multi function digital meter of suitable range to read V,A,KVA, KVAH, KWAH, KW, KVAR, PF, Hz etc and LED display with required Nos CTs, 15 VA, class 1 class and control circuit wiring with MCBs - 1 No.
1 Set of Indication Lamps, LED type, R,Y,B and breaker 'ON' , 'OFF', 'TRIP' & spring charged lamps.
BUS BAR
FP Alluminium busbar of 1250A with 50 KA fault level capacity, mounted on non-hygroscopic, glass fibre reinforced insulators-1Set
OUTGOINGS
125A, 25KA FP MCCB (Microprocessor Release) with power contactor & 50 KVAR capcitor - 4Nos
63A, 16KA FP MCCB (Microprocessor Release) with power contactor &25 KVAR capcitor - 4Nos
40A, 16KA FP MCCB (Microprocessor Release) with power contactor &15 KVAR capcitor - 2Nos
32A, 25KA FP MCCB with TVSS - 1set
1 Lot of control wiring.1 Set of designation plates.
Two numbers 50mm X 6mm GI earthing terminals - one on each side of the panel with earth strip run inside the panel
Supplying, installing by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints, elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners,connecting to earthing system etc. as required
2000 A 50kA SC for 1 sec
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including etc. complete : testing of joints
300 mm dia. R.C.C. pipe
SAFETY ITEMS
Supply of the following safty as per standards and specification
Fire Extinguishers - 4.5 KG CAPACITY CO 2 Confirming to IS 2878 fitted with discharge bend pipe and horn fitted on wall
Rubber Mats 415 V, 2 m x 1 m
Shock treatment Chart with wooden frame and glass
First Aid Box
3 Nos of buckets with canopy & stand
415 V Danger Boards
11 KV Hand Gloves
SUBHEAD- XXV: AREA LIGHTING:
Supply and erection of steel stepped and swaged tubler poles of 9mtr. Long (410 SP25) (1.5mtr below Ground) with base plate, earthing studs,1.5Mtr out reach single/ Double arm, FRP terminal box, 2nos (0.75mtrs each) 40mm dia class B GI Pipe for incoming and outgoings cables, including Excavation in all types of soil, PCC 1:2:4, PCC Pedestal complete with painting with black bitumin paint inside the coping for embedded portion and two coats of Zinc chromate primer and two coats of Aluminium paint externally for length above the ground. The pole shall be with FRP Junction box consisting of 10A MCB. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm Copper conductor cable. The Pole shall be fixed with 70W LED Lamp with fixture including supply of Controlgear / driver and lamp (Make :Wipro Cat no. LR02-102-XXX-57-G2, make: Philips Cat No-GreenLine V2 (BRP410)
Supply, erection and commissioning of individual 3mtr (600mm below Ground) high 65mm dia Class B GI pole, 750mm out reach single arm complete with base plate FRP terminal box, wiring from terminal box to the fixture with 3 core 2.5sq.mm copper conductor cable, MCB Control and 2nos of 40mm dia Class B GI pipe for incoming and outgoing cables etc including PCC foundations, pedestal and Supply and installation of 45W LED Lamp Post top Lantern fixture Integral type with Lamp and Controlgear/driver. (Make:Wipro,Cat no. LP02-501-XXX-57-XX, / Make:Philips,Cat no. Metronomis LED Torch BDS670 GRN40)
Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments.
Supply of following size 1.1KVgrade XLPE insulated armoured aluminium conductor underground cable, in built up cable trench/ already laid RCC hume pipe / on surface of slab and walls with clamps or on cable tray with all installation materials. The cable shall conform to IS.
4C X 10Sq.mm Aluminium
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required
Upto 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required.
4 X 10 sq. mm (25mm)
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including etc. complete : testing of joints
100 mm dia. R.C.C. pipe
SUBHEAD- XXVI: LIFT
Design and supply 1020 kg capacity flight cum passenger lift with speed of 1 Mtrs/Sec and three landings at ground floor, first floor,second floor including gearless elevator, variable voltage variable frequency drives,(V3F)machines,controllers,car body,Car guides, Counter weights,main suspension steel ropes,cabling,safetydrives (viz) governor,Automatic Rescue Devce (ARD) car size 1400 x1800mm car automatic cental opening sliding doors for car and landing side as per item 9.3 of is 14665/2000 or latest edition, doors,joist,way door,buffers for car and counter weight as per specification, with accessories etc.Complete Make: Mitsibushi/Kone/OTIS/Schindler
Loacation of Lifts : ADVANCE HILLS FACILITY
Speed - 1 Metre per second.
Floors - G + 1.
Travel - 6.5 metre. (3.90 Mtr + 3.60 Mtr )
Stops and opening. 2Nos
Controller : Variable voltage and variable frequency Drive (V3F)
Operation : LCE based simplex Full Collective controls with or wwithout attendant operation.
Power - 415 V , 3 phase , 50 Hz .
Type of doors.
a.) Car. - Centre Opening Power Door (COPD)
b.) Landing door - Centre Opening Power Door (COPD)
Car Enclosure : Stainless Steel Hairline Finish.
Flooring: Steel Chequered Plate.
SUBHEAD- XXVII: EOT CRANE
Part-I: - Supply:
Design, manufacture and supply of Double Girder EOT Cranes with all speeds 'VVVF' Drive control and micro speed arrangement for Hoist, CT & LT and conforming to IS 807/IS 3177 and other relevant IS standards of the latest revisions as shown below complete with all taxes, duties and other charges such as transportation to site, loading and unloading at stores/building, where to be installed etc.,movement of material to work spot including the cost of paint as required. The Crane shall be designed for earthquake and sesmic qualification. Span to be measured by the Bidder at Site and it shall be his sole responsibility to provide span suitable.
Supply of 5 Ton capacity Double Girder crab type EOT Crane with VVVF drive complete with long travel and cross travel movements as per technical specifications and as per IS: 807 / IS: 3177 and other relevant IS standards of the latest revision. All drives should be provided with alternative parallel path with DOL starter for main speed only. Building :Hangar (Advance Hils Facility) Span: 9.7mts(+/-0.5mts)(Exact Span to be measured at site) Lift: 6.00 mts. Bay length: 15.00 mts.
Supply of shrouded bus bar system with double shoe copper current collections system complete with support tracks, cable loops, junction boxes and cable from main supply point to crane festoons with all necessary fixtures.
Supply of material for Gantry Rails section 40 Square bar of prime material in length of 10 mts and above complete with mounting arrangement at the building over the crane girder including painting of rails with approximate colour code as approved by the dept.
Part-II: - Erection, testing and commissioning :
Erection, testing and commissioning of EOT crane and other allied items mentioned in Part-I as per the relevant IS standards
Erection, testing and commissioning of 5 Ton capacity crab type EOT crane mentioned in Item Sl. No.560 of Part-I as per the relevant IS standards inclusive of installation of complete Crane completion of all electrical and mechanical works including performance tests with No load, Full load and over load testing as per the approved QA Plan etc complete.
Erection testing and commissioning of shrouded type current collection system complete as per the item Sl No 561 of Part I over the crane bay including tapping of supply for electrical panel testing & handing over the crane as per the approved QA plan etc complete
Erection, testing & commissioning of Gantry rail section 40 Square bar mentioned in item Sl No 562 of Part -I with mounting arrangement and fixing hardware etc., complete over the bay length to match the span of the crane within the permissible accuracy levels for span in height variation as per the QA Plan etc complete
SUBHEAD XXVIII :AIR CONDITIONING
Supply, Installation, testing and Commissioning of double skin floor mounted thermal break air handlig unit. The panels made out of 45 +/- 2 mm thick fabricated out of pre coated 0.6 mm thick GI on outer side and 0.6 mm thick plain GI on inner side with PUF insulation density of 38+/-2 Kg/Cu.m. The framework shall be of internally coved extruded aluminum and thermal break hollow sections. AHU shall comprising aluminum airfoil blade low leakage type SA & F/A dampers suitable for manual/motorized operation. pre filter scetion with 10 micron filters,coil section with 6 row INTERLACED/INTERWINTED design DX Cooling coil to make multi distributers for multiple circuits as per requirement. Insulated SS 304 stainless steel drain pan, fan section with PLUG type FAN, with EFF1 motor, CFL lamps for filter sections & fan sections with on / off switches for operation from outside, limit switch for the fan section & access door with a view glass, fire retardant flexible canvas connection between fan & AHU panel, internal vibration mounts for fan & motor frame, and supply plenum with aluminum airfoil blade low leakage
S/A damper suitable for manual/motorized operation. scope include all the internal wiring of the unit for lamps & limit switch etc. Heater section wtih high efficiency flame proof finned heaters mounted on insulated porceline supports with fire rataurded cabling ect. The Heaters shall be operated & controlled with PID thyrestor controller & it controllers in conjunction with temp & RH sensors. Heaters shall be installed with safety devices like Air flow switch, Air start / somke detectors and scope includes necessary complete control wiring etc. All the internal wiring of the unit for lamps & door interlock,Heater banks & controles etc shall be in the scope of the AHU vendor.
a) AHU 1 - 22TR capacity, dehumidifier air qty 8800cfm at 65mm Static pressure, 6 Row DX coil Interlaced/Interwined multi circuit design with 3 Nos of 11TR capacity condensing units( 2 x 11 TR working + 1 x 11 TR Stand by), Heater banks with 12 KW capacity flame proof Heaters .
b) CSU 1 - 11TR capacity, dehumidifier air qty 4400cfm 50mm Static pressure,Fan section with DIDW forward curved fan, 6 Row DX coil interlaced/interwined multi circuit design with 2 nos of 11TR capacity condensing units( 1 x 11 TR working + 1 x 11 TR Stand by),Heater bank with 3 KW capacity flame proof Heaters.
c) CSU 2 - 11TR capacity, dehumidifier air qty 4400cfm 50mm Static pressure, Fan section with DIDW forward curved fan, 6 Row DX coil suitable for 11TR capacity condensing unit (1 x 11 TR working ), Heater banks with 3 KW capacity flame proof Heaters.
DX Condensing Units For Air Handling Unit connected
Supply,Installation, testing & commissioning of Scroll type compressor R410A /R407C, Condenser units of following capacity including Thermostatic Expansion valves one per each circuit, saftey control and thermostat and PLC control panel, inter connected control / power cables and other accessories etc. The unit shall be precharged and included with any topup charging at the time of commisioning .the controls , vavles and accessories along with the equalisation timer , seqencitial controller and the expansion devices and its safities shall be included in the cost of the unit. only refrigerant piping between the units shall be measureable.
a) 11 TR Condensing units
Supply, Installation, Testing and commissioning of following size hard copper piping for Condenser units circuits with insulation of 13mm thick Nitrile Rubber pre formed sections The insulation finished with treated woven glass fiber reinforced covering and covered with 26G AL cladding for exposed Piping including supporting fixtures and accessories etc., complete.( 11 TR condenser units 9Nos )
Supply, Installation, Testing and commissioning of following size hard copper piping for Condenser units circuits with insulation of 13mm thick Nitrile Rubber pre formed sections The insulation finished with treated woven glass fiber reinforced covering for inside Piping including supporting fixtures and accessories etc., complete.( 11 TR condenser units 9Nos )
VRF Outdoor Units
Supply, testing & commisioning of total VRF system of Variable Refrigerent Flow outdoor units comprising multiple digital scroll compressors / Inverter Compressors ,low noise propellor type aero spiral fan,Condenser coil,refrigerant shut off valves,safety devices, lead free PC boards suitable for operation on R410A /R407C and on 415 V+/- 10%, 50 Hz, 3 phase A/C supply. power supply provide only one point for each set of out door units , Including Refrigerant Gas charging to the system and units Lifting,Shifting, Positioning & Commissioning of the Units ,The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5
Makes: Daikin//Mistibhushi/Toshiba
a)38HP (GF & FF)
Daikin : RXQ38ARY6; Mistibushi: PUCY P 950YKA(BS) ; Toshiba : AP3827T8P
b) 28 HP (GF& FF )
Daikin : RXQ28ARY6; Mistibushi: PUCY P 700YKA(BS) ; Toshiba : AP2827T8P
Indoor Units
Supply, testing & commisioning of Cassette type indoor units comprisisng with pre-filter,fan section with low noise fan multispeed motor, coil section with DX coil, outer cabinet, decorative panel for cassette units,drain water lift-up meachanism, insulation, pipe connections including card less remote , fresh air intake etc. of various capacities as per specifications and drawings.Including Lifting,Shifting, Positioning & Commissioning of the Units
a)1.5TR Casstee Unit
MODEL NUMBER : DAIKIN =FXFQ50SVM/ MITSUBISHI = PLFY-P50VBM-E / /TOSHIBA=MMUAP0184 HP1 -E
b)2.0TR Casstee Unit
MODEL NUMBER : DAIKIN =FXFQ63SVM/ MITSUBISHI = PLFY-P63VBM-E / /TOSHIBA=MMUAP0244 HP1 -E
c)2.5TR Casstee Unit
MODEL NUMBER : DAIKIN =FXFQ80SVM/ MITSUBISHI = PLFY-P80VBM-E / /TOSHIBA=MMUAP0304 HP1 -E
d)3.0TR Casstee Unit
MODEL NUMBER : DAIKIN =FXFQ100SVM/ MITSUBISHI = PLFY-P100VBM-E / /TOSHIBA=MMUAP0364 HP1 -E
e)4.0TR Casstee Unit
MODEL NUMBER : DAIKIN =FXFQ125 SVM/ MITSUBISHI = PLFY-P125VBM-E / /TOSHIBA=MMUAP0484 HP1 -E
Supply of Hi wall split type indoor units comprisisng with pre-filter,fan section with low noise fan multispeed motor, coil section with DX coil, outer cabient, insulation, pipe connections including card less remote etc. of various capacities as per specifications and drawings.
a)1.5 TR Hi wall Split unit
MODEL NUMBER : DAIKIN =FXAQ50PVE6 / MITSUBISHI = PKFY-P50VHM-E / /TOSHIBA=MMK-AP0186HP-1-IN
Supply, Installation, Testing and Commissioning of Hard copper REFRIGERANT PIPING including required refnet Joints of 19swg various sizes with necessary supports, fittings, interconnecting the liquid and suction lines between the aircooled outdoor units and the indoor units. The piping shall be carried out of Hard drawn copper pipes of type 'K with soldered / brazed socket fittings. Isolating valves shall be provided to isolate each compressor, strainers, sight glass and any other component requiring proper operation and maintenance. Both the suction and liquid lines shall be insulated with 19mm thick closed cell insulation for above 25mm dia , 13mm thick for pipes below 25mm dia . The insulation finished with treated woven glass fiber reinforced covering and covered with 26G AL cladding for exposed Piping and including making required holes in the wall and re finishing and water tight of holes after laying holes as per the specifications and approved drawings.
iii) 19.1 mm
vii)34.93 mm
viii)41.3 mm
Supply, Installation, Testing and Commissioning of Hard copper REFRIGERANT PIPING including required refnet Joints of 16swg various sizes with necessary supports, fittings, interconnecting the liquid and suction lines between the aircooled outdoor units and the indoor units. The piping shall be carried out of Hard drawn copper pipes of type 'K with soldered / brazed socket fittings. Isolating valves shall be provided to isolate each compressor, strainers, sight glass and any other component requiring proper operation and maintenance. Both the suction and liquid lines shall be insulated with 19mm thick closed cell insulation for above 25mm dia , 13mm thick for pipes below 25mm dia . The insulation finished with treated woven glass fiber reinforced covering for inside Piping and including making required holes in the wall and re finishing and water tight of holes after laying holes as per the specifications and approved drawings.
iii) 12.7mm
vii)25.4 mm
viii)28.6 mm
Supply & Installation PVC drain piping with suitable supports as required & insulated with 6mm thick Nitrile rubber insulation.
CENTRAL CONTROLLER
Supply, Installation, Testing and Commissioning of CENTRALISED Remote Controller advanced I Touch Manager type. Upto 128 Indoor units in single controller
Supply, Installation, Testing and Commissioning of CONTROL CABLING of 2C x 1.5 sq.mm flexable copper cable for communication between indoor and outdoor units to be suitably laid in 25 mm PVC conduit as per site requirement.
Supply, Installation, Testing and Commissioning of REMOTE Centralized Controller cabling of 2C x 1 Sq.mm. flexable copper cable to be suitably laid in 25mm PVC conduit as per site requirement.
Supply, Installation, Testing and Commissioning of CONTROL CABLING of 3C x 1.5 sq.mm flexable copper cable for communication between indoor and outdoor units to be suitably laid in 25 mm PVC conduit as per site requirement.
Supply , erection , testing of Factory fabricated GI ducting using class VIII sheets / coil, galvanised hardware & supports, silicon sealant at all joints, Angle iron angle flanges for all the joints, bracing angles where ever required and minimum 5mm thick neoprene rubber gasket
a) 24 Gauge
b) 22 Gauge
c) 20 Gauge
Supply, Fixing, Testing and commissioning of Extruded Aluminum powder coated Continuous Grills & Discreet Grills as per specifications including required wooden frame as per the site conditions.
Supply, Fixing, Testing and commissioning of Extruded Aluminium powder coated removable core type 4 way Diffusers as per specifications
Supply, Fixing, Testing and Commissioning of
a) Duct Dampers
b) Fusible link GI Fire dampers with fusible links
c) Extruded AL powder cated Jet Diffuser of 315 Dia with collar damper including all fixing accessories.
Supply and fixing of Aluminium powder coated fresh air Louvers with bird screen wire mesh & damper, including standard fixing accessories etc., complete and sizes as per drawing.
Supply and fixing of thermal insulation with 19mm thick Class"O" Al foil faced Nitrile rubber material with fixing accessories etc complete for Supply & Return Air ducting .
Supply and fixing of Acoustic Insulation with 10mm Open cell nitrile rubber material for Ducting.
Supply, Fixing, Testing and commissioning of Extruded Aluminium collar dampers for supply Air grills
Supply and fixing of AHU room wall Acoustic Insulation with 50mm thick Fibreglass rigid boards and covered with RP Tissue and 26G Aluminium perforated sheet fixing with 25mm wide GI strip interval of 600 X 600 grid as per specifications.
Supply and fixing the Gypsum board boxing work on the side walls for covering the supply duct and return air. The boxing shall be with GI Channel frame work (Channel thcikness and size shall be to suitable as per the site condition) along with 12mm thick Gypsum board and finished with 3 coat of Painting as per the room finish.
Supply, Installation, Testing and commissisioning of Factory Fabricated 25mm thick PUF panel plenum box with 0.6mm /0.6 mm pre coated / plain GI outer /inner skins as per the drawings at 500 FPM velocity as per site conditions
Supply,installation,testing and commissioning of the following capacity Single skin cabinet type Inline fresh air Fans with 10micron filter with three speed fans along with the all accessories etc complete. The fan is suitable for single phase power supply operation.
a) 500 CFM @ 30 mm static pressure
ELECTRICAL PANEL
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V 4 wire Free Standing Floor mounted MV panel made out of 2mm thick CRCA/Galvanised steel enclosure for main frame and 1.6mm thick partitions and shall have IK Certification as per IEC 62262 for mechanical strength/ruggedness, after seven tank process and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves. The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below.The panel shall be got fabricated from manufacturers as per IEC 61439(Part-1&2). Indoor panels shall have IP-4X degree of protection and outdoor panels shall have IP-55 degree of protection wiith external door . Enclosure shall be modular with bolted design. Enclosure shall be powder coated with RAL-7035 coat with matt finish. Design ambient temperature shall be 50 degree centrigrade. No use of hygroscopic material like FRP/Hylam/Bakellite sheet inside the panel for partitions or any other purpose.
a) CHAMBER 2 NOS AHU'S HVAC PANEL
Incoming :
320A,36KA 4P MCCB with Thermal Magnetic Based Release – 1 No
6A SP MCB control for RYB indication lamps
Busbars :320 A 4P Aluminium Busbars. 1 set
Metering Incomer :
Outgoings :
63A, 4P, 100ma RCBO with Indication lamps – 9 Nos
32A,10KA 4P MCB with Indication lamps–1 no
Step controlled digital thermostat able to receive 1 no analog input and produce 3 nos digitial outputs .
b) DTMS / FMS & HANGER CSU HVAC PANEL
Incoming :
160A,25KA 4P MCCB with Thermal Magnetic Based Release – 1 No
6A SP MCB control for RYB indication lamps
Busbars :
160A 4P Aluminum Bus bar – 1 Sets
Metering Incomer :
Outgoings :
63A, 4P, 100ma RCBO with Indication lamps – 5 Nos
40A, 4P, 100ma RCBO with Indication lamps – 3 Nos
Step controlled digital thermostat able to receive 1 no analog input and produce 3 nos digitial outputs .
c)OUTDOOR VRF HVAC PANEL
Incoming :
250A,36KA 4P MCCB with Thermal Magnetic Based Release – 1 No
6A SP MCB control for RYB indication lamps
Busbars :
125A 4P Aluminum Bus bar – 1 Sets
Metering Incomer :
CBCT's of ratio 100/5A Class 5 Accuracy and 15VA burden with Earth lekage Relay-1 set
Outgoings :
63A, 4P, 100ma RCBO with Indication lamps – 8 Nos
Step controlled digital thermostat able to receive 1 no analog input and produce 3 nos digitial outputs . Make : Dixcell
d) Isolator Box
Supply, installation, Testing and Commissioning of 2 nos 63A, 4P, 100ma RCBO in enclosed a weather proof box wall mounted suitable for out door application with class protection not less than IP - 65 .and incoming & outgoing cable bottom Entry with sutable Weather Proof glands.
e) ON/OFF Push button Station
Supply, installation, Testing and Commissioning of on /off push button station with enclosure , all Control wiring & termination connectionsas required as per the site condition , fixing arrangement etc complete.,
MV CABLES:
Supply and commissioning of following size 1.1KVgrade PVC insulated armoured Aluminium/Copper conductor cable as per IS : 7098
a)4CX25 SQMM PVC CU.AR.CABLE
b)4CX16 SQMM PVC CU.AR.CABLE
c)4CX6 SQMM PVC CU.AR.CABLE
d)4CX4 SQMM PVC CU.AR.CABLE
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE/FS power cable of 1.1 kV grade of following size on wall surface as required.
a) Upto 35 sq. mm (clamped with 1mm thick saddle)
MV CABLE TERMINATIONS:
Providing Indoor ordinary end terminations for the cable specified above with double compression type steel gland,Bi-metallic lugs using crimping tool,Insulation tape,Identification tags etc., including end termination and Earthing of Gland with 8SWG 'GI Wire
a)4CX25 SQMM PVC CU.AR.CABLE
b)4CX16 SQMM PVC CU.AR.CABLE
c)4CX6 SQMM PVC CU.AR.CABLE
d)4CX4 SQMM PVC CU.AR.CABLE
CABLE TRAY
Supply and Installation of following size 2mm thick GI Perforated type cable tray with top covering GI sheet, coupler plates, bends, elbows, tees etc as required. The scope also includes suitable cable tray supports arrangements on walls/Ceiling/Trench with M.S.Structrual steel / Threaded rods, anchor bolts & nuts wherever required as per site conditions.
a) 100 mm wide x 50 mm deep x 2 mm thick
b) 200 mm wide x 50 mm deep x 2 mm thick
EARTHING
a) Providing G.I. Earth station, with 40mm dia 2500mm long GI pipe including construction of brick pedestal, providing meshed funnel,CI cover and other civil Engineering works,spreading a homogenous mixture of salt, charcoal aroundthe pipe etc, completely as per IS 3043, 1987 or latest revision.
b) Supply and laying of following earth strips/ conductors.
i) Supply and fixing of 50 x 6 MM GI Flat
ii) Supply and fixing of 25 x 6 MM GI Flat
iii) Supply and fixing of 8 swg GI wire
SUBHEAD XXIX : WATER COOLERS
Supply , installation testing and commissioning of storage water cooler with storage capacity of 80 liters and cooling capacity of 40 liters suitable for operation on 230V +10% , 50 HZ, full stainless steel body including multistorage RO Purification system , 2 KVA voltage stabilizer etc complete Make Wate Cooler : Voltas / Blue Star / Usha. Water Purifier : Eureka Forbes / Kent / ION Exchange. Stabilizer : Keeline / V- Guard
SUBHEAD XXX: FIRE FIGHTING SYSTEM
Supply, laying, testing and commissioning of centrifugally Cast Ductile Iron pipes conforming to IS 8329:2000 class K9, with Cement Mortar Lining (CML) inside as per IS 455:2989 along with Bituminous coating outside suitable for socket and spigot type (DISS) joints including Bends, Elbows, Tees, Flanged Spigots, Collars, flanges (flange rating PN 16) etc testing the joints for leakage (if any) for the following sizes
Providing Push-on-joints to the above ductile cast iron pipes and specials including cost of jointing materials & testing of joints
Supply installation testing and commissioning of Fire brigade inlet with 4 built in NRV and One Sluice valve with glass cover box and interconnections etc complete.
Supply, erection, testing and commissioning of Double Headed Fire Hydrant with 63 mm female instantaneous outlet in oblique type complete with cap & chain generally as per IS 5290.'
Supply & fixing 63 mm dia Cotton Synthetic Fibre (RRL) Woven rubber lined fire hose delivery treated against rot with MYSTOX, conforming to IS 636 type 'A' bounded with male and female instantaneous G.M. couplings and of length of 30 M.
Supply and fixing of Gun Metal branch pipe 63 mm dia, male and female threaded outlet complete with hexagonal base bore nozzles as per IS 903.
Supply and fixing of Fire Hose Box of MS of size 3 'x 2' x 1'6" to accommodate one numbers of 30 M length hoses and branch pipe, glass fronted, double door with lock painted fire red outside with suitable structural support complete but excluding civil works.
Supply and laying of 600 mm dia. NP2 grade RCC hume pipes with collars for road crossings laid 1200 mm below ground level including excavation, back filling etc., complete as required.
Supply and laying of 450 mm dia. NP2 grade RCC hume pipes with collars for road crossings laid 1200 mm below ground level including excavation, back filling etc., complete as required.
Supply and Fixing of Cast iron Route Marker at an interval of 50 m for fire fighting system including PCC (1:2:4).
SUB HEAD XXXI : FIRE ALARM SYSTEM
Supply,Testing and commissioning of the following number of Loops Microprocessor based addressable type (EN / UL approved) Fire alarm control panel with Zonal Indications, supervised inputs, supervised and non-supervised outputs,Zener barriers, two way media converter / Signal booster for in / out network connectivity with OF cableand with battery Power pack as per specifications.
a) 2 - Loop
Supply installation, testing and commissioning of analog addressable type multi sensor (smoke / heat) photo electric detectors with base and LED indication lamp along with all fixing accessories.
Supply installation, testing and commissioning of reponse indicators with LED indication lamp along with all fixing accessories.
Supply, Installation, Testing and commissioning of anologue addressable loop sounders along with all fixing accessories.
Supply, Installation, Testing and commissioning of fault isolators along with all fixing accessories.
Supply,Installation,Testing and commissioning of anologue addressable type monitor module along with all fixing accessories.
Supply,Installation,Testing and commissioning of addressable control module along with all fixing accessories.
Supply, Installation,Testing and commissioning of anologue addressable ordinary Manual call point with push type along with all fixing accessories.
Supply and laying of 25mm dia medium class FRLS PVC conduit concealed in wall /ceiling / above false ceiling including bends,elbows, junction boxes, saddles, spacers etc., and other material required for fixing complete as per requirement.
Supply,laying,testing of twisted pair 1.5sq mm shielded FR insulated copper conductor flexible wire in existing PVC conduit.
Supply, fixing and installation of fire exit signage's self illuminating light fixtures displaying exit with an arrow towards the exit door.
Supply and installation of 2.5 KM range siren with weatherproof motor with 220V 50 Hz AC Supply operation with required power contactor, MPCB for control all in a weatherproof enclosure near motor including all installation materials as required for completion of work.
Supply and laying of 3 core 2.5 sq mm copper conductor PVC insulated armoured cable including all fixing accessories for connectivity of the siren with all required fixing accessories etc., complete
Supply, installation, testing and commissioning of 8 way Wago/ Phoenix terminal connector in weatherproof MS junction box including painting and all installation materials etc complete as required
Supply, installation, testing and commissioning of weather proof analogue addressable break glass type manual call point with 1500mm long 50X50X6 channel fixed on ground with PCC coping with all required accessories etc., complete.
Supply, installation, testing and commissioning of Single ended reflector type addressable Beam smoke detector with all required accessories etc., complete.
Supply & Installation of Carbon-di- oxide type fire extinguisher of 4.5 kgs. Capacity, CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge nozzle, bend & horn, wal mounting bracket etc. complete, confirming to IS: 2878.
Supply & Installation of Mechanical Foam Type fire extinguisher of 9 Ltrs. Capacity, filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge nozzle, bend & horn, wal mounting bracket etc. complete confirming to IS: 2878.
Supply & Installation of Water CO2 Type fire extinguisher of 9 Ltrs. Capacity, filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel, with wheel type valve, discharge nozzle, bend & horn, wal mounting bracket etc. complete confirming to IS: 940.
Supply & Installation of ABC Stored pressure type Fire Extinguisher of 5 kgs capacity with stand,fitted with discharge control valve (Squeeze grip type) CE marked and pressure gauge,filled with mono ammonium phosphate powder as per EN 3 615 approval,with discharge hose and open nozzle and supplied complete with initial charge as per IS: 15683 with ISI mark. Fire Rating 3A,21B
Supply & Installation of ABC Stored pressure type Fire Extinguisher of 2 kgs capacity with stand,fitted with discharge control valve (Squeeze grip type) CE marked and pressure gauge,filled with mono ammonium phosphate powder as per EN 3 615 approval,with discharge hose and open nozzle and supplied complete with initial charge as per IS: 15683 with ISI mark. Fire Rating 3A,21B
NIMMA NARAYAN ENGINEERS & CONTRACTORS
RVR PROJECTS PRIVATE LIMITED
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid