Hyderabad Division: SC-DHNE Section: Umdanagar - Shifting of existing Crossover No. 18 towards Budvel end for relaxing PSR and Provision of additional Crossover towards Jukal end for making UP loop Line as Common Loop Line - Signal and Telecom arrangements.
Y-SG-36-2025-26-32~SCR
Y-SG-36-2025-26-32
Open
Works - General
12 Months
Hyderabad, Telangana
₹0
₹2.5 L
6 Feb 2026
7 Jan 2026
23 Jan 2026
Item Breakup - A-Schedule - A
Supply of CLS Post 140mm Dia to Specn Numbers IRS:S 6-81 Rev.3 or latest - 4.5m Long (Inspection: RITES).
Supply of CLS Post 140mm Dia to Specn Numbers IRS:S 6-81 Rev.3 or latest - 3.5m Long (Inspection: RITES).
Supply of Ladder set complete with Set staging/platform, supports, cast iron ladder base/Shoe. for 4.5m post as per Drg No. SA 23153, S 2033 or Latest (Inspection: RITES).
Supply of CLS Ladder set complete with Set staging/ platform, supports, cast iron ladder base/Shoe. for 3.5m post as per Drg No. SA 23150, 5 2033 or latest (Inspection: RITES).
Supply of Surface Base 140mm Dia CLS post Numbers as per Drg No. 52011/M (Inspection: RITES).
Supply of Metallic (MS) Colour Light Signal Numbers Unit 2 Aspect complete as per Drg No. SA.23003/AIM (Adv.) with latest amendment and Specn IRS: 5 26-64 or latest (Inspection: RITES)..
Supply of Metallic (MS) Colour Light Signal Numbers Unit 3 Aspect complete as per Drg No. SA.23002/AIM (Adv.) with latest amendment and Specn IRS: 5 26-64 or latest (Inspection: RITES)..
Supply of Metallic (MS) Colour Light Signal Numbers Unit 4 Aspect complete as per Drg No. SA.23001/AIM (Adv.) with latest amendment and Specn IRS: 5 26-64 or latest (Inspection: RITES).
Supply of Offset Bracket to suit 140mm Dia Numbers CLS post with two numbers of U bolts and nuts complete (Inspection: RITES).
Supply of Ground type Position Light Shunt Numbers Signal complete with base, pipe, arrow mark and hoods as per RDSO Drg No. SA 23840 or latest (Inspection: RITES).
Supply of Junction type I Direction type Numbers Route Indicator as per Specn IRS:S 66-84 Amd.1 or latest - Two way as per Drg No. SA 23402 (Inspection: RITES).
Supply of Junction type I Direction type Numbers Route Indicator as per Specn IRS:S 66-84 Amd.1 or latest - Four way as per Drg No. SA 23404 (Inspection: RITES). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Calling On Signal Unit complete Numbers with U Bolts as per RDSO Drg No. SA.24351 (Adv.) or latest (Inspection: RITES).
Supply of 'E' type lock of specified ward as Numbers per requirement with one key E-type lock to Drg No. SA3376/M or latest and Specn IRS: S30-64 or latest. (as specified by site/store incharge) (Inspection: RITES).
Supply of Relay fixing Frame for Full Numbers Location Box. The Frame shall be of approximate size 940mm x 150mm and made with powder coated MS Angle of 25mmx 25mmx3mm. The Frame shall have suitable holes to fix in Full Location Box (Inspection: Consignee).
Supply of Track feed battery charger to work Numbers on 110V AC for charging 1 or 2 or 3 or 4 lead acid cell of 80AH (10 Amps) used in track circuit as per RDSO Specn No. IRS.S.89/2013 Ver 1.0 latest. (Inspection: RDSO)
Supply of Track Lead Junction Boxes Fibre Numbers Glass as per Drg No. CWM-00597 of FRP material to and Specn IRS:S 23 along with fixtures i.e., one MS angle 50mmx 50mmx5mm, 0.9m long, two numbers of GI pipes of 25mm Dia, 500 mm long along with nuts and bolts and 500 mm long (grommet bushes, 60 mm ARA terminals-2 Nos) (Inspection: Consignee).
Supply of 'B' type Chokes to as per Specn Numbers IRS: S65-83 Amd.l or latest (Inspection: RDSO).
Supply of Stationary Low Maintenance Numbers Secondary Lead Acid Cells as per RDSO Specn IRS:S88-2004 or latest. This includes supply of inter cell connectors, bolts, nuts, Acid level indicating floats and vent plugs - 2V, 80AH (Inspection: RDSO).
Supply of Distilled water for topping of Litre Secondary Cells as per Specn IS 1106 or latest (Inspection: Consignee).
Supply of Porcelain Insulators for Secondary Numbers Lead Acid Cells (Inspection: Consignee).
Supply of Track Feed Regulating Resistance Numbers Disk Type 00 to 300 as per Drg No. SA 20161 66/M or latest. To be procured from RDSO approved firms (Inspection: Consignee).
Supply of Galvanised Wire rope 6/19 steel, Metre 6mm Dia with fibre core as per Specn IS 3459/2004 or latest. (Inspection: Consignee)
Supply of Plug-in type miniature tractive Numbers armature Non-AC immune, DC Neutral Line Relay complete with plug board, retaining Clip/ATC Clip and connectors as per Specns BRS 930, lRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS: S67-85 Amd.3 or latest (as applicable) - QN1- 8F/8B, 24 V DC. The interlocking code: ABODE (Inspection: RDSO).
Supply of Plug-in type miniature tractive Numbers armature Non-AC immune, DC Neutral Line Relay complete with plug board, retaining Clip/ATC Clip and connectors as per Specns BRS 930, lRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S67-85 Amd.3 or latest (as applicable) - QNI-12F/4B, 24 V DC. The interlocking code: ABODE (Inspection: RDSO). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of 24 V DC Plug-in type miniature Numbers tractive armature, AC immune Relay complete with plug board, retaining Clip/ATC Clip and connectors as per IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S60-78 Amd.1 or latest, IRS:S67-85 Amd.3 or latest (as applicable) - QBCA1- 2HF/4B, Interlocking code: BCEJK as per Specns BRS 943 or latest (Inspection: RDSO).
Supply of 24 V DC Plug-in type miniature Numbers tractive armature, AC immune Relay complete with plug board, retaining Clip/ATC Clip and connectors as per IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S60-78 Amd.1 or latest, IRS:S67-85 Amd.3 or latest (as applicable) - QNA1- 8F/8B, Interlocking Code: ABDGH as per Specn BRS 931 A or latest (Inspection: RDSO).
Supply of 24 V DC Plug-in type miniature Numbers tractive armature, AC immune Relay complete with plug board, retaining Clip/ATC Clip and connectors as per IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S60-78 Amd.1 or latest, IRS:S67-85 Amd.3 or latest (as applicable) - QNA1 - 12F/4B, DC Neutral Line Relay, Interlocking Code: ABDFH as per Specn BRS 931 A or latest (Inspection: RDSO).
Supply of 24 V DC Plug-in type miniature Numbers tractive armature, AC immune Relay complete with plug board, retaining Clip/ATC Clip and connectors as per IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S60-78 Amd.1 or latest, IRS:S67-85 Amd.3 or latest (as applicable) - QSPA1- 8F/4B, The interlocking code: ABDEJ, Spec BRS 933A or latest (Inspection: RDSO).
Supply of AC immune, plug-in type, Style Numbers 'QTA2', 2F/1 B DC Neutral track relay for Rly Signalling track circuits with coil resistance 9 ohm, complete with plug board, retaining clip and connectors as per Specns: BRS 939A & 966 or latest, IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S67-85 Amd. 3 or latest (as applicable) with interlocking code FGHKX (Inspection: RDSO).
Supply of ECR 4E/4B' for 110V AC lit LED Numbers signals, complete with plug board, retaining clip and connectors as per RDSO Specn No. STS/E/Relays/ AC Lit LED Signal/09-2002 Amd.1 or latest, BRS 941A, IRS:S23-88 Amd.1 or latest, IRS:S34-68 Amd.6 or latest, IRS:S67-85 Amd.3 or latest (as applicable). The interlocking code for this unit shall be ABDHK (with ATC clips) (Inspection: RDSO).
Supply of GI termination box (10 SWG) for Numbers point machine of size 45 cms x 23 cms x 12 cms with double coat of enamel paint (outside: Black & inside: White) along with 2 Nos. of MS angle of size 50x50x6mm of length 1000 mm each, 2 numbers of 40mm GI pipe of length 450 mm & 150 mm with nuts/washers and teak wood plank of size 40mmx25 mm for fixing of terminals. (Inspection: Consignee) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply connections for high thrust 220 mm stroke point machine along with insulation as per Drg No. RDSO/S3454 Alt.B, dt.25.01.2023 or latest along with insulation. (Inspection: RITES)
Ground connection insulations for thick web Set switch layout facing point (BG) for 52 Kgs/60 Kgs Rail fitted with high thrust Point Machine comprising of the following:1) Bush as per Drg No. S3463-1 No. and Washer as per Drg No. 58640-2 Nos. for drive (throw) rod.2) Bush as per Drg No.S23199-1 No. and Washer as per Drg No. S8640-2 Nos. for short detector rod.3) Bush as per Drg No. S23199-1 No. and Washer as per Drg No. S8640-2 Nos. for long detector rod.4) Bush as per Drg No. S22179-1 No. and Washer as per Drg No. S8640-2 Nos. for short lock rod.5) Bush as per Drg No. S22179-1 No. and Washer as per Drg No. S8640-2 Nos. for long lock rod.6) Bush 'B' as per Drg No. S8912 for LH lock slide-1 No. 7) Bush 'B' as per Drg No. S8912 for LH lock arm-2 Nos. 8) Bush 'B' as per Drg No. S8912 for RH lock arm -2 Nos. 9) Bush 'B' as per Drg No. S8912 for RH lock slide-1 No. 10) Bush as per Drg No. S23199- 4 Nos. and washer as per Drg No. S8640-4 Nos. for LH lock slide.11) Insulating Plate LH as per Drg No. S3404 RDSO/S 3593-1 No. 12) Insulating Plate RH as per Drg No. S3404 RDSO/ S3592-1 No. 13) Bush as per Drg No. S23199-4 Nos. and washer as per Drg No. S8640-4 Nos. for RH lock slide (Inspection: RITES).
Supply of Terminal Block: 1 way Poly Numbers Butylene Terephthalate (PBT) of size 60mm (link centre to centre) as per RDSO Drg No. SA23745/Alt.5 or latest, SA23746 /Alt.5 or latest, S23747/Alt.5 and Specns IRS: S75- 2006 Rev.2.0 (Tentative) or latest, IRS: S23- 88 Amd.1 or latest (Inspection: RDSO).
Supply of Terminal Block: 6 way Poly Numbers butylene Terephthalate (PBT) of size 25mm (link centre to centre) as per RDSO Drg No. SA23756/Alt.3 or latest, S23757/ Alt.4 or latest and Specns IRS:S 75-2006 Rev.2.0 (Tentative) or latest, IRS:S23-88 Amd.1 or latest (Inspection: RDSO).
Supply of Modular Terminal Block (WAGO or Set similar) as per RDSO Specn RDSO/SPN/189/2004 Ver.3.0 or latest consisting, the following parts: a) 2 conductor disconnect terminal block-6 Nos. b) End/intermediate plate suitable for 2 conductor disconnect terminal-1 No. c) Screw less end stop similar to WACO Model No. 249-117-2 Nos. d) Insulated jumper WAGO Model 280-402-5 Nos. e) Din Rail - 0.1 metre per set (in length of 1 metre for every ten set) (Inspection: RDSO).
Supply of Non-Deteriorating type of Fuse Numbers Holders and Fuse Links 240V AC/DC as per Specn IRS:S 78-2006 or latest, IS 13703 (Part 2):1993 knife edge type Fuse of El Fuse Link type (up to 20A) - Fuse holder 20A capacity (Inspection: RDSO). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Non-Deteriorating type of Fuse Numbers Holders and Fuse Links 240V AC/DC as per Specn IRS:S78-2006 or latest, IS 13703 (Part 2):1993 knife edge type Fuse of El Fuse Link type (up to 20A) - Fuse link 1A/2A/6A/10A /16A/20A as specified by Engineer in charge (Inspection: RDSO).
Supply of PVC insulated Wire Coils Multi- Numbers strand, single core, copper conductor 16/0.2 (16 wires, Diameter of each wire is 0.20mm) (0.5 Sq.mm) wire coil as per Specns IS 694:2010 or latest, IRS:S76-89 Amd.3 or latest. Length of coil should be 100m. Colour of coil to be specified by Engineer in charge (Inspection: RDSO). (Unit : Coil)
Supply of 10 Sq.mm PVC insulated, multi- Metre strand, single core, copper conductor 140/0.3 (140 wires, Diameter of conductor 0.3mm) cable as per IS: 694 or latest, IRS:S76-89 Amd.3 or latest. Cable to be supplied in 100 meter coil (Inspection: RDSO).
Supply of PVC insulated Wire Coils Multi- Numbers strand, single core, copper conductor 28/0.3 (28 wires, Diameter of each wire 0.30mm) flexible wire coil as per Specns IS 694:2010 or latest, IRS:S76-89 Amd.3 or latest. Length of coil should be 100m. Colour to be specified by Engineer in charge (Inspection: RDSO). (Unit : Coil)
Supply of Universal Locks with one steel key Numbers for every ten locks or part thereof (For example, if locks ordered is 10, 1 key is to be supplied and if locks ordered is 20, 2 keys to be supplied. However, 2 keys to be supplied if locks ordered is between 11 and 19) (Inspection: Consignee).
Supply of Double Walled Corrugated (DWC) Numbers HDPE Duct of various Diameter of length of 6m as per Specn RDSO/SPN/204/2011 Ver.1.1 Amd.1 or latest. The Duct shall be supplied along with push-fit type 0-ring coupler or end cap - DWC of outer Diameter 180mm and inner Diameter 153mm (Inspection: Consignee).
Supply of Basic Material to construct unit Set Maintenance Free Earth as per Specn RDSO/SPN/197 Ver.1.0 or latest consisting of the following: a) Copper bonded steel electrode 3m long, 17mm diameter with copper bonding thickness mini 250 micron and UL listed and marked - 1 No. b) Earth enhancement compound of RDSO approved brand supplied in sealed bags of minimum 10 Kgs - 3 Nos. c) Copper strip with dimensions 150x25x6mm to terminate earth rod - 1 No. d) Copper strip with dimensions 300x25x6mm Main Equipotential Earth Bus bar (MEEB) - 1 No. e) Copper strip of with dimensions 150 x 25 x 6mm Sub Equlpotential Earth Bus bar (SEEB) - 1 No. f) 35 Sq.mm multi-strand PVC insulated Copper Cable (15 meter) (Inspection: RDSO). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of 35 Sq.mm PVC insulated multi- Metre strand, single core, copper conductor 277/0.4 (277 wires, diameter of each wire is 0.4mm) cable as per IS:694 or latest, IRS:S76-89 Amd.3 or latest. Cable to be supplied in 100-meter coil. Colour to be specified by Engineer in charge (Inspection: RDSO).
Supply of Copper lugs 10sq.mm of reputed Numbers make. (Inspection: Consignee)
Supply of Thermo Shrink Jointing Kit for Numbers jointing underground 0.9mm Dia conductor 6 Quad cable as per Specn IRS:TC 77-2012 Rev.3 (Amd.1 to Amd.3) or latest (to be procured from approved firm) (Inspection: RDSO).
Supply of Permanently lubricated HDPE Duct Kilometre with outer Diameter of 40mm and inner Diameter of 33mm as per Specn RDSO/SPN/TC/45/2013 Rev 2.0. The length of the duct shall be 1 Km. Two end plugs shall be provided along with the drum (Inspection: Consignee).
Supply of Axle detectors (each set consists Numbers of 2 Nos. Tx and 2 Nos. Rx coils) for High Availability Single Section Digital Axle Counter (HASSDAC) as per Specn RDSO/ SPN/177/2012 Ver. 3.0 or latest. (Inspection: RDSO) Total 2781432.00
Item Breakup - B-Schedule - B
Location Survey for Cable Route and Route Kilo preparation of tentative Cable Route Plan as Meter per the instructions of Engineer in-charge. (RKM)
Excavation of trench, including marking of Route Kilo cable alignment, clearing of jungle, roots of Meter trees, bushes, trial pits if required, refilling (RKM) with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work in all type of Soil including soft rocky area as per RDSO Sketch No. SDO/CABLE LAYING/003, as directed by engineer incharge - Depth of 1200mm and width of 300mm.
Cutting of Rock, concreting after cable laying RMT with 1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number of days, except in bridges, culverts, level crossings, track crossings, cable pits and rocky soil including marking of cable alignment, clearing of debris etc., complete to the finished item of work as directed by engineer in-charge. All the material is to be arranged by contractor. Depth of 200mm and width of 200mm where rock is visible from surface to a depth more than 300mm up to 550mm, excavation of trench with width 300mm above rock, concreting 200mm x 200mm after laying of cable as per Drg No. SK/CN/ NEW/3. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
When rock is visible for more than 0.5 Meter RMT and up to 0.8 Meter from ground level, excavating the trench minimum 0.5 Meter and maximum 0.8 Meter, laying cable and concreting 200mm x 200mm over the rocky surface after levelling with soil/sand.
Track Crossing/Road Crossing by Horizontal RMT Boring method at Culverts/Track/Pucca road as per SCR Drg No. 5770. This also includes insertion of HDPE pipe of 110mm/GI Pipe of 100 mm in the bore drilled (HDPE pipe/GI pipe is to be supplied by Rly).
Trenching under Rails for Crossing the Track RMT (Track Crossing) and refilling of Trenches as per SCR Drg No. 5768. The Track Crossing shall be done at right angles. The depth of Cable Trench shall be 1.2 meter below the Rail Flange. The depth between top cable and the level of rail flange of the rail shall never be less than 1.0 meter. The ballast shall be stacked separately while making the Trench and the Earth soil shall be stacked separately. While re-filling the Trench, the Earth Soil has to be filled first to the ground level and the ballast has to be properly put in the Track. This work has to be done under Supervision of Supervisor of S&T and Supervisor of P.Way.
Breaking of Metal/Tar Road and refilling after RMT laying the Cables as per Drg No. SDO/CABLE LAYING/010. The surface of the road shall be concreted to match with the old surface.
Cable laying and meggering different type RMT Cables in the Trench. Termination covered elsewhere.
Excavation of coil pit up to a Depth of 1 Numbers meter and Dia of 1.5 meter for providing coil at Location Box, Point, Signals etc. This includes back filling and ramming of Trench/Pit after laying the Cable and consolidation of soil.
Supply & laying of GI Pipes of 100mm RMT Diameter with medium and threaded collar & coupler, quality to Specn IS.1239 (part-I) 1990 and galvanised to Specn IS 4736-1986.
Supply, transporting & installation of Numbers Concrete (RCC) Route Indicators at intervals of 50 meters as per instructions of Engineer- in-charge as per Drg No. SK 12/10. They should be of standard RCC with letters "SCR S&T cable" as per type of Cable laid to drawing. In case of Telecom Quad Cable Joint Locations it shall be painted with Green and Orange colour for normal indication of Cable Path.
Provision (including transportation of all the material). Providing and laying in position Cement concrete of specified grade including the cost of centring and shuttering: 1:3:6 (1 Cement: 3 coarse sand (zone-Ill): 6 graded stone aggregate 20mm nominal size).
Centring and shuttering for Provision & Sqm laying cement concrete HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Excavation foundation & erection of apparatus case Full size as per SCR Drg No. 5781 and fixing of 1 No. of 'E' type lock for the front door, latching arrangement for backdoor, fixing of Hylam sheet (Hylam sheet supply is covered elsewhere and Wooden Reapers also can be used in place of Hylam sheet for which supply & fixing covered elsewhere) and painting the apparatus case inside and outside with one coat of red oxide, two coats of aluminium paints outside and white paint inside including painting of termination, equipment and number particular on location box (foundation bolts and nuts, 'E' type lock, cement, river sand, stone jelly of size 20/20 mm, paints, varnish, fixing bolts and nuts and all other miscellaneous material required for the work shall be supplied by the Contractor).
Test lamp arrangement in LBs/RE cuttings Each (Auto mobile handle type). (Unit : Per Location)
Supply & fixing of Teak Wood Reapers/Blocks Numbers suitable for Full Box: 75mm width x 20mm thick and length of 940mm after applying two coats of Wood primer. (Unit : Per Reaper)
Supply & fixing of Teak Wood Reapers/Blocks Numbers suitable for Full Box: 50mm width x 50mm thick and length of 940mm and clamping the cable after applying two coats of Wood primer. (Unit : Per Reaper)
Supply & fixing of Hard Wood Planks for Numbers Keeping Equipment in the Full Box: 940mm x 20mmx 300mm approximately after applying two coats of Black enamel paint. (Unit : Per Plank)
Cable termination including fixing terminals, Per 30000.00 fuses, LDs, Meggering of cables and Conductor recording the readings.
Fixing Relay bases, wiring in Location Boxes, Per Relay bunching, fixing of Relays as per Circuit Diagram. This includes fixing of Condensers, Resistance, 6 way /1 way Terminals/WAGO, ND type Fuses, LED Indicators for Fuses as per type Fuses.
Fabrication, Conventional Earth to Signalling/Telecom equipments-Excavation of Earth and No. 6652 providing Earth pipe of size 50mm Dia 3.5mm thick 2.0 m long GI pipe of heavy quality with masonry tub constructed around at earth locations as specified by site Engineer. Alternate layers of 30 Kgs-charcoal and 30 Kgs-common salt to be filled in the pit while closing. The pipe perforation etc., to be carried out as per Drg No. SK 10/10. The Earth pipe to be connected to the function with Cable as supplied by Rlys. The reading should be painted on the masonry tub. The masonry tub of 300 mm x 300 mm x 300mm (along with Kundi) should be covered with cement slab.
Earthing and Soldering of Cable Armour. Each (Unit : Per Cable) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Provision MS flat connection from Earth pit to RMT LBs/ Signals including supply and laying of MS Flat of size 40X6mm at site, supply of GI bolt of size M12X40mm with two Nuts along with two plain washers and one spring washer, drilling of holes in MS flat of different sizes at site, cutting with bending and twisting of MS flat as required at site, painting of MS Flat with one coating of red oxide as primary and two coats of anti- corrosive black paint and drilling of holes in Location Boxes at site.
Welding for jointing MS flat 6mm thick X Each 40mm width of different lengths strips connecting from Earth to Location Boxes/Signal Post/Signal Unit for better continuity. Prior approval of welding material to be taken from Engineer-in-charge. (Each Weld)
Foundation & erection of Shunt Signal which Numbers includes;a) Excavation of pit & casting concrete foundation as per Drg No. SG/CN/02/10 using metallic templates, for erection of ground type Colour Light Shunt Signal. (Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25 mm and all other miscellaneous materials for the work shall be supplied by the contractor). b) Erection of Ground type Shunt Signal complete including surface base, signal post, LED aspects, number plate, termination of tail cables, wiring of signal unit, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint, Supply of Ground type shunt signal complete including surface base, signal post, LED unit is to be supplied by Rlys). [EWS locks, enamelled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the contractor). 60% Payment after completionof work mentioned at (a) and remaining 40% after completion of work at (b)).
Foundation & erection of Shunt Signal which Numbers includes;a) Excavation of pit & casting concrete foundation as per Drg No. SG/CN/02/10 using metallic templates, for erection of ground type Colour Light Shunt Signal. (Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25 mm and all other miscellaneous materials for the work shall be supplied by the contractor). b) Erection of Ground type Shunt Signal complete including surface base, signal post, LED aspects, number plate, termination of tail cables, wiring of signal unit, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint, Supply of Ground type shunt signal complete including surface base, signal post, LED unit is to be supplied by Rlys). [EWS locks, enamelled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the contractor). 60% Payment after completion of work mentioned at (a) and remaining 40% after completion of work at (b)). HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Fixing of junction type Route Indicator - 2 Numbers way - complete/fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved circuits diagram, provision of required number of EWS locks, wire mesh and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this schedule). [Fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor] - 2 way route indicator.
Fixing of junction type Route Indicator - 4 Numbers way - complete/fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved circuits diagram, provision of required number of EWS locks, wire mesh and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this schedule). [Fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor] - 2 way route indicator.
Fixing of Offset brackets using 'U' bolts and Numbers nuts, erecting of Calling On Signals/'A' Marker lights, termination of tail cables and wiring, provision of EWS lock, number plates/markers boards and painting. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down. (Supply of Calling On Signal/'A' marker light, LED aspect/holders and bulbs, wire coils and off set brackets will be supplied by Rlys). ['U' bolts and nuts, through bolts with nut, EWS lock, Enamelled number plates, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor.
Manufacturing, supply, painting & fixing of Each Markers of G/P/C/A/AG/IB Markers as per IRSEM Drg No. 19-D10 on MS sheet of thickness 3mm. Miscellaneous material required for fixing Markers is to be supplied by Contractor.
Provision of Screen on Signals when they fall Numbers with in 2 meters from the live conductor by expanding metal (size 20mmx60mm strand 3.25 mm wide and 1.6 mm thick) as per the instruction of site engineer in charge. This includes supply of all materials including connection with earth electrode as per SCR Drg No. 5767.
Supply & fixing of cross bar on signal (signal Numbers not in use) made of hard wood of size 1000mmx100mmx 20mm. The cross bar shall be painted white as per Signal Engineering Manual. All material required for installation shall be supplied by Contractor. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Installation, termination box, wiring, testing and commissioning of High Thrust point Machine. This includes fixing of point machine on MS plate fixed on sleepers complete with fixing of anti theft covers, MS termination boxes, ground connections, required insulation, crank handle ward (wherever required) etc. This also include necessary adjustment and smithy work, drilling of holes on tongue rails, supply of all miscellaneous material such as flat, angle, bolt, nuts, pins etc. (Unit : Per Point Machine)
Wiring of Track Circuits Feed end, relay end Numbers complete with TLDs, batteries, chargers, Chokes, track relays, double lead wires, providing insulation etc. Connected with track commissioning of track circuit including provision of bracket for TLD covers and painting. Anti-tilting arrangement has to be done for chargers & batteries. All miscellaneous material required for installation shall be supplied by Contractor.
Drilling of four Nos. of 7.2mm holes, per rail Numbers joint on web of the rail, providing bond wires with wire rope. (Bond pins single groves are to be supplied by Contractor - Wire rope for bonding will be supplied by Rlys). (Unit : Per Rail Joint)
Fixing of approximately 200 Nos. of 6 way/1 Set way terminal lock horizontally on 6mm Hylam sheets which in turn to be fixed to rack with all supports as per instructions of SSE in charge. Materials such as bolts, nuts and supporting flats to be supplied by the Contractor only.
Cutting & fixing of Hylam sheet of 6 Lumpsum mm/3mm thickness to suit to 1 way Relay Rack and fixing the following with contractors screws, bolts and nuts and fixing strips, condensers and resistances of various values - 50 Nos.
Fixing of Non-deteriorating Fuse Holders with Numbers LED Indications and Resistors and negative terminal strips on 6mm Hylam sheet with Contractors screws, bolts and nuts. on Pre- erected Relay Racks.
Initial Charging of Secondary Cells with Numbers uninterrupted Power Supply - 2 volts 80 AH.
Straight transformer joints: Installation Thermo shrinkable jointing kits for straight through/derivation joints for LC Gate, pump houses etc. where VF transformers are not required and derivation joint by using 2T transformer (to be housed in the joint). This includes tapping of nominated Quad at a specific location shown by the Rly Engineer at site to the jelly field cable already laid. All material including valco tapes except thermo shrinkable jointing kit shall be supplied by the Contractor. (Unit : Joint)
Fabrication, fixing of required configuration Numbers of key for point machine for grouping of crank handle.
Supply, placing and covering of RCC duct RMT from Home to Home as per SCR Drg No. 5778. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Fixing of Track Lead Junction Box on angles Numbers (50x50x6 mm size), drilling one hole on either side of the box of suitable size and fixing Track Lead Junction box by the side of the track, drilling 4 holes of 7.2 mm Dia on Rail, connecting double track leads with bond pins, running track lead wire, termination of track lead wire on ARA terminals duly fixing the same inside the TUB Teak wood board bolted inside the track lead junction box. (Fixing angles, bolts, nuts and teak wood boards to be supplied by the Contractor).
Supply, painting & fixing of gland plate for Numbers Location box as per site requirement - Full Location Box.
Dismantling & releasing of existing Colour Numbers light Signals complete (up to 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Rly representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling.
Releasing of existing Ground type Shunt Numbers Signals along with surface base, signal post etc. carefully without any damage, accounting and stacking them neatly at a place as instructed by Rly representative at site. The work also includes breaking and removal of concrete foundation and refilling of the resultant pit by ramming and levelling.
Dismantling and releasing of existing Point Numbers machines (all types) including ground connections and other accessories available complete without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Rly representative at site.
Supply & installation of OFC Joint Enclosure Numbers and Splicing of Optic Fibre Cable (24 Fibres) and testing as per Tech Specn No. GR OJC- 2/02 Sept 2003. Supply of Splice Enclosure (24 fibre) shall be of TVS make Part No. 1500-LI8X-XX or similar as per Board Specn of TEC & as per RDSO/SPN/TC/68/2014 Rev.1.0 Amd.1 or latest. All materials including Fusion Splicing Machine used for Fibre Splicing and OTDR for testing and other testing materials if any shall be arranged by the Contractor. (Inspection: Consignee for supply)
Laying of HDPE duct 40/33 mm Dia in the Kilometre trenches and in protective works already provided. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Blowing of armoured Optic Fibre Cable (OFC Kilometre Cable supplied by Rlys) into the duct supplied vide other NS item of supply portion by using blowing machine and associated works. 10% of OFC length to be blown extra on both ends of Duct i.e. total 20% of Duct length. Before blowing the duct integrity shall be tested. If any defect is found during duct integrity test, the entire length of HDPE Duct from one chamber to another chamber is to be replaced by the Contractor at his own cost. Payment will be made as per the length of Duct from which OFC is Blown.
Excavation of jointing pit & provision of Numbers RCC/FRP Joint/Loop Chambers of 90 Cms. Inner Dia 60 Cms depth and 3mm thickness with two pieces of top cover with hooks each and bottom cover with hole for drainage and cable entry as per Drg No. RAILTEL/SR/ OFC/2009/12 and as directed by Engineer to be provided at every joint location and at every Kilometre loop etc. The chamber shall be filled with sand mixed with ariti-stermic power, back filling and ramming of trench after HDPE Duct laying, splicing and commissioning.
Fabrication, Supply and fixing of CALLING ON Numbers instruction boards, STOP boards/BSLB/Shunting Limit Board/Auto section board or any other board with engineering grade reflective sticker of size 600X1000 mm GI sheet, with MS angle of 75X75X6 mm with 6 meter length including paint, excavation of pit and concrete foundation etc. as per the instructions of sight in-charge. All necessary materials to be arranged by the contractor).
Provision of foundation for the signal Numbers warning boards/ calling on boards/all types of boards. (A pit of size 400 mmx400mmx1500 mm is to be dug and cement concrete foundation in the pit in the ratio 1:3:6 to be casted. The rail post/MS angle is to be erected up right in the foundation.
Supply, erection and fixing of retro reflective Numbers type BPAC Warning boards/IBS Legend Board of size 1000X600X3 mm. The boards shall be provided with Retro Reflective type BPAC Warning boards. MS Angle, stone jelly of size 20/25mm Dia, river sand, cement, fixing bolts and nuts, paint and all other miscellaneous materials required for the work shall be supplied by the contractor. HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Installation arrangements if required), testing and commissioning of SSDAC/ HASSDAC. The work consists of: a) Fixing of axle counter track device consisting of Tx-Rx coil assembly for each detection point drilling holes in the rails as per the marking given by the site in charge. b) Fixing of rails deflector plates on either side of each detection points as per the marking given by the site in charge. c) Fixing of evaluators inside pre- erected location boxes on the nominated planks along with VR assembly duly providing anti-vibration arrangements, fixing terminals and wiring as per the instructions of site in-charge. d) Routing cables from Tx/Rx coil assembly through pre laid GI/HDPE pipe arrangements of track crossing and entering the location box and termination (60 % Payment after installation & Testing and 40% after commissioning).
Releasing of existing Multi Detection point of Set Axle Counter field equipment (transmitters & receiver coils) on the rails at the entry/exit track circuits without causing any damage. Excavating the under the track for removing track devices, connecting cables and duly covering the cable duct. Disconnecting and removing of Amplifier (electronic junction box and other associated equipment from the location box and transporting to a central location for account.
Design of SIP in Auto Cad for a Six-Line Set Station Initially, contractor shall submit 3 copies for approval of Rlys. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Rlys. After carrying out changes, three Hard copies to be submitted for Rly approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Rly) in properly bound booklet along with its scanned copy.
Preparation of Table of Control based on SIP Numbers issued in Auto Cad in A3 size or as per Rly practice. Initially, contractor shall submit 2 sets of document for approval of Rlys. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Rlys. After carrying out changes, two sets of Hard copies to be submitted for Rly approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and two sets of final approved drawing in properly bound booklet along its scanned copy. (Unit : Per Route) HYDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Design of Cable Route Plan (Distant to Set Distant) for a Six-Line Station including details of all Track Crossing/ Horizontal boring/Cable Loop/Cable Joints etc. in AUTO CAD & submission of coloured paper copies for approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing in plastic cover (Ammonia Print or print as approved by Rly) in properly bound booklet along with its scanned copy.
Design of Cable Distribution Plan for a Six- Set Line Station in AUTO CAD & submission of Three paper copies for approval as per the practice of SCR. After approval, AUTO CAD copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing in plastic cover (Ammonia Print or print as approved by Rly) in properly bound booklet along with its scanned copy.
Design of Track Bonding Plan For a Six-Line Set Station in AUTO CAD & submission of Three paper copies for approval. After approval, AUTO CAD copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing in plastic cover (Ammonia Print or print as approved by Rly) in properly bound booklet alongwith its scanned copy.
Design of Location Box Drawings in AUTO Numbers CAD (including Contact Analysis, Fuse Particulars, Cable Particulars etc.) and submission of Three paper copies for approval in A4/A3 white papers. After approval, AUTO CAD copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies in Ammonia Print of final approved Drawing in plastic cover in properly bound booklet along with its scanned copy. (Unit : Per Location Box) Total 7942619.00
Item Breakup - C-Schedule - C
Supply of Hylam sheet, resin bonded, 10mm Numbers thick, grade P3, and size 2400mm X 1200mm. (Inspection: Consignee)
Supply of QUINT Inverter DIN Rail Mounting, Numbers Input 24V DC/110V DC and Output 230V AC/120V AC, 600VA for VDU. (Inspection: RDSO) Total 637720.00
Item Breakup - D-Schedule - D
Alteration/modification of Station TCAS at Lumpsum Umdanagar Station as per RDSO/SPN/196/2012 Version 3.2 or latest in connection with the Yard modification, as per Specn given in Annexure-XVIII. (Inspection: RDSO) Total 4007280.00
Item Breakup - E-Schedule - E
Modification to the existing EI System at Lumpsum Umdanagar Station as per RDSO Specn No. RDSO/SPN/192/2019 or latest, in connection with the Yard modification as per Specn given in Annexure-XVIII. (Inspection: RDSO) Total 4475000.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril2022.pdf
ATTACHMENT
GCCcorrectionSlip1to10.pdf
ATTACHMENT
Experience.pdf
ATTACHMENT
Annexure-VIBTurnover.pdf
ATTACHMENT
LetterofCredit.pdf
ATTACHMENT
MakeinindiaPolicy1.pdf
ATTACHMENT
32TD.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .