Tender Value
₹1.6 Cr
EMD Value
₹2.3 L
Closing Date
2 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKSOL
19 conditions · 8 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less, where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure- VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. per Annexure-N & Annexure-I of tender booklet
The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender as per Annexure- G of tender booklet.
b) (1) In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of dvertised value of each component of tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii) One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b)(2)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (3) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway.
In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates.
In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Definition of Similar Work: -Any Signaling work.
28 conditions · 24 needing a document upload
Please submit your bank details i.e. Name of the Bank along with Bank Branch Code, Account Number, IFSC Code, and PAN Number.as per annexure -J of tender booklet.
Please furnish list of plant and Machinery available on hand own and proposed to be inducted own and hired to be given separately for the subject work. as per annexure -E of tender booklet.
Please furnish list of Works on hand indicating Description of Work, Contract Value, Approximate value of balance work yet to be done and Date of award.
Please furnish list of Works completed in last seven financial years giving Description of Work, Organization for whom executed, approximate value of contract at time of award, Date of award and Date of Completion. Date of actual Start, Actual Completion and Final value of Contract shall also be given. Annexure -G.
Please furnish list of personal, organization available on hand and proposed to be engaged for the subject work.
Documents to be Submitted Along with Tender: (i)The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / HUF etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. (ii)Following documents shall be submitted by the tenderer:
(a)Sole Proprietorship Firm: All documents in terms of Para 10 of the Tender Form (Second Sheet) above (As per GCC-2022). (Annexure-O-1 of tender booklet.)
(b)HUF: i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.as per GCC-2022.
(c)Partnership Firm: All documents as mentioned in para18 of the Tender Form (Second Sheet) as per GCC-2022.As per GCC- 2022. (Annexure-O-2 of tender booklet.)
d) Joint Venture (JV): All documents as mentioned in para 17 of the Tender Form (Second Sheet).as per GCC-2022.
(e)Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.(Eligibility Criteria) above as per GCC-2022. (Annexure-O-10 of tender booklet.)
(f)(i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet)..(Eligibility Criteria) above as per GCC2022. (Annexure : O-11 & O-12 of tender booklet.)
(g)Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) above.
The tenderer whether sole proprietor/ a company or a partnership firm/registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner(s) of the firm or any other person, specifically authorizing him/them to sign the tender, submit the tender and further to deal with the Tender/ Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association /Board resolution, failing which tender shall be summarily rejected.
Any DIPP certificate submitted along with the tender document for, exemption of EMD should be valid on the date of opening of the tender, else the tender offer will be summarily rejected.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderers may also upload the following documents along with his/their tender: The tenderer may upload statement, which shall contain organizational set up and working systems to be adopted by the successful tenderer s during the operation of the contract. It shall contain the details of man power and machineries in the prescribed format and details of methodology for planning, execution, monitoring and completion of the project. The methodology so adopted shall suit to the nature of work and shall also comply fully with best practice and current regulations. A comprehensive detailing for each activity like setting-up organization, safety plan, execution plan, quality assurance plan, sequence of work to achieve the mile stones, ensure targeted progress and quality and in turn deployment of resources, risk analysis and its mitigation strategy shall be given communication arrangement within his organization and with the railways for decisions, progress or any other matter connected with this project to ensure full information about the project including progress of work at different time scale shall also be furnished.
List of works completed in the last seven financial years giving description of work, organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and final value of contract should also be given.
Supportive documents/certificates from the organizations with whom they worked/are working as list of works completed and list of works on hand should be enclosed.
List of works on hand indicating description of work, contract value, and approximate value of balance work yet to be done and date of award.annexure -H
Uploading of declaration regarding Employment/Partnership etc. of Retired Railway Employees as per GCC-2022 as per annexure -Q of tender booklet.
Uploading of Tender Forms shall embody the contents of the contract documents either directly or by reference and shall be as per specimen form, Annexure-I. e-Tender Forms shall be issued free of cost to all tenderers.
A copy of certificate stating that they are not liable to be disqualified and all their statements/documents submitted along with bid are true and factual. Standard format of the certificate to be submitted by the bidder is enclosed as Annexure-V. In addition to Annexure-V, in case of other than Company/Proprietary firm. Annexure-V(A) shall also be submitted by the each member of a partnership firm/Joint Venture (JV)/ Hindu Undivided Family (HUF)/ Limited Liability Partnership (LLP) etc. as the case may be.Non submission of a copy of certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he are/is qualifying the Qualifying Criteria mentioned in the Tender Document. (As per Railway bord letter no.2022/CE-l/CT/GCC- 2022/Policy dt. 13.12.2022)
Declaration form regarding site etc. as per annexure -C of tender booklet.
Declaration regarding constitution of firm as per Annexure-D of tender booklet.
Engineers/Personnel as per annexure -F of tender booklet.
Performa of Completion Certificate as per annexure -L of tender booklet.
Provision of S&T work in connection with Interlocking of LC Gates No. 377, 382 and 473 having TVU greater than 20,000 of Jhansi Division.
JHS-N-W-15-26~NCR
JHS-N-W-15-26
Open
Works - General
12 Months
Jhansi, Uttar Pradesh
₹0
₹2.3 L
2 Mar 2026
4 Feb 2026
16 Feb 2026
148 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,01,90,062.68 | ||
| — | 3.00 | — | — | ||
| Supply of Micro Processor based Remote Terminal Unit (RTU) with 128 digital input & 16 analog input as per RDSO Spec. No. IRS (S) 99/2006 (Amdt. 3) or latest. It includes supply of all the items required for complete indoor relay room wiring from RTU to relay rack tag blocks, drawing/extension of power supply up to RTU. It includes supply of relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD (if installed) , IPS, interlinking and networking of RTU. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No. STS/E/Data logger dtd.12.09.2011 or latest guidelines.(Inspection Agency- RITES). | — | — | — | 7,80,534.75 | |
| — | 100.00 | — | — | ||
| Supply of Non deteriorating type, Round head type, low voltage cartridge fuse as per Spec No IRS: S-78/2006 with latest amendments, 2A/4A/6A/8A/10A rating capacity.(Inspection Agency- RDSO). | — | — | — | 12,314 | |
| — | 100.00 | — | — | ||
| Supply of Cartridge Fuse block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23748 (Alt.-4) or latest.(Inspection Agency-RDSO). | — | — | — | 24,355 | |
| — | 200.00 | — | — | ||
| Supply of ARA terminal block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23741A (Alt.-4) or latest.(Inspection Agency-RDSO). | — | — | — | 23,402 | |
| — | 3000.00 | — | — | ||
| Supply of Disconnect Terminal block for four conductors with screwing cage /clamp type, sliding switch disconnect, as per RDSO spec. No. RDSO/ SPN/189/2004 Ver. 3.0 or latest, for each conductor size up to 2.5 sq. mm, equivalent of M6 terminals. Each terminal block equipped with two markers, on top and bottom, an end plate, two end clamps and adequate length of rails for fitting terminal blocks.(Inspection Agency-RDSO). | — | — | — | 5,78,160 | |
| — | 216.00 | — | — | ||
| Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) with thread collars as per IS 1239 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dial hole, or at any other locations as decided by Site Engineer.(Inspection Agency-Consignee). | — | — | — | 2,14,122.96 | |
| — | 360.00 | — | — | ||
| Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 Ver.1.1 Amdt.1 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One couple with suitable rubber O-ring should be supplied with every 6 mtr of pipe length.(The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified.(Inspection Agency-Consignee). | — | — | — | 2,18,473.2 | |
| — | 18.00 | — | — | ||
| Supply of Colour Light Signal Post, Tubular Mild steel, 4.5 m length, 140 mm Dia, as per RDSO spec. No. IRS: S-6/81 or latest and Supply of cast iron Main signal surface base (As per RDSO Drg. No. 2011/M or latest), 'with CLS ladder assembly suitable for colour light signal 4.5 m long, as per RDSO drg. No. SA 23153 and signal front staging complete assembly and complete signal back staging for CLS unit.(Inspection Agency-Consignee). | — | — | — | 4,54,926.24 | |
| — | 50.00 | — | — | ||
| Supply of hand cuff lock of Godrej/Navtal or reputed make with key and as approved by site engineer.(Inspection Agency-Consignee). | — | — | — | 22,688 | |
| — | 1.00 | — | — | ||
| Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signalling suitable for RE area FOUR Aspects, complete 'without lenses, lamps and signal transformer as per RDSO Drg. No. SA23001 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.(Inspection Agency-Consignee). | — | — | — | 42,230.83 | |
| — | 11.00 | — | — | ||
| Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area THREE Aspects, complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23002 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.(Inspection Agency-Consignee). | — | — | — | 3,93,111.07 | |
| — | 6.00 | — | — | ||
| Supply of Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area TWO Aspects, complete without lenses, lamps and signal transformer as per RDSO Drg. No. SA 23003 A/M (Adv.) and as per RDSO spec. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest.(Inspection Agency-Consignee). | — | — | — | 1,87,848.48 | |
| — | 3.00 | — | — | ||
| Supply of Electrically Operated Lifting Barrier complete set suitable for 110VDC/110VAC / 24V DC supply, without hand generator back up, and motorized boom locking arrangements as per RDSO Spec. SPN/208/2012 Ver. 2.0 or latest. The 02 Nos of Barriers of length 09.76 Mtrs. should be supplied along with stop boards and light. The spares & tool kit mentioned in RDSO Spec. no. RDSO/SPN/208/2012 Ver. 2.0 and Amndt. 1 or latest, clause 10.1 & 10.2 reproduced as below should be supplied along with each full set :- i) GI boom - 1 no. complete. ii) Belt - 1 no. iii) Crank handle - 1 no. iv) Motor Contactor - 1 no. v) Motor protection MCB- 1 no. vi) Push button complete- 2 nos. i) Limit switch - 3 nos. (1 lever type and 2 top roller type viii) Fuses used - 2 sets Tool kit consisting of standard sizes of wrinch/ spanner and Allen keys should also be supplied with each set (02 nos.) of Electric Lifting barrier. make GLOBAL, heinz or similar.(Inspection Agency- RDSO). | — | — | — | 11,37,479.25 | |
| — | 6.00 | — | — | ||
| Supply of Dual Tone Bell /Buzzer with Flasher arrangement and 20 Watt horn working on 24 V DC/ 110 V AC for warning road users at LC gates.(Inspection Agency-Consignee). | — | — | — | 34,842.6 | |
| — | 3.00 | — | — | ||
| Supply of Relay racks assembly complete with scaffolding bus bars, fuse strips, fuses, resistors, capacitors, insulators. grouting bolts, tripods etc. as per approved drawing of NCR [Scaffolding should include 20% extra (with minimum of 2 relay rack positions) as spare for future expansion). Relay rack shall be Powder Coated. (Quantity of Resistance, capacitor & Other items). (Inspection Agency-Consignee). | — | — | — | 78,748.26 | |
| — | 24.00 | — | — | ||
| Supply of Apparatus Case/Location Box Full as per RDSO drg. no. RDSO/S-11500 or latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. (Inspection Agency- RITES). | — | — | — | 6,59,995.44 | |
| — | 12.00 | — | — | ||
| Supply of Apparatus Case/Location Box Half as per RDSO drg. no. RDSO/S-11507 or latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys.(Inspection Agency-Consignee). | — | — | — | 2,38,856.28 | |
| — | 3.00 | — | — | ||
| Supply of working table for SMMS system as per tech specification.(Inspection Agency-Consignee). | — | — | — | 53,808 | |
| — | 2.00 | — | — | ||
| Supply of maintenance Service Terminal for installation, testing and maintenance of all Signalling system parameters and as per Technical Specification.(Inspection Agency-Consignee). | — | — | — | 1,45,777.38 | |
| — | 3.00 | — | — | ||
| Supply of Insulated Tools and measuring instruments as per technical specification. (Inspection Agency-Consignee). | — | — | — | 2,12,378.88 | |
| — | 3.00 | — | — | ||
| Supply of working desk for relay room as per specification.(Inspection Agency- Consignee). | — | — | — | 53,853.6 | |
| — | 1.00 | — | — | ||
| Supply of battery operated Rail Core Drill machine (Eiben stock Make ERD35-2-V50.4 Bor similar) as per RDSO specification no.TM/SM/468 dated 31.03.2014 First Revision, 2017 or latest. Suitable clamp for 52 Kg and 60 Kg rail to be supplied along with each machine. The suitable drill bit for sizes 7.2 mm (Solid drill), 13 mm (Rail HSS Cutter), 14mm (Rail HSS Cutter), 16mm (Rail TCT Cutter), 22 mm (Rail TCT Cutter) to be included as standard accessory in each machine.(Inspection Agency-Consignee). | — | — | — | 1,03,309 | |
| — | 5.00 | — | — | ||
| Supply ,Installation , Commissioning and Testing of split core structure, non contact measurement, Real In Time testing, high accuracy, high stability, resistance range 0.01- 100,resolution 0.001, accuracy ±2% rdg± 3dgt, working Temp. & humidity-20 55, 20% RH 90% RH, Detector Light and Sound Alarm, IP-54 protection, RS 485 communication, with extended 4 digit LCD. Display can be mounted up to 2 Mtr. distance from detector unit. (Suitable for Transmission Line/ Railway facilities/ Communication/ Sub Station/ Electrical equipment Grounding. Consists of (Model no-KOBLE 2800 KB ver.3.0 or superior): (a) Main detector unit- 01no., (b) LCD enclosure fitted with Aviation plugs-01 no. (c) Set of detector to LCD enclosure connecting two cables each 2 mtr. Length fitted with Aviation connector-01 set (d) Rs-485 connector with 0.5 mtr. Cable-01 no (e) RMCU with PFC- 01 no.Make/Brand: KOBLE or superior (Warranty Period : Up to 30 months from the date of supply).(Inspection Agency-RITES). | — | — | — | 5,81,104.6 | |
| — | 2.00 | — | — | ||
| Supply of surge protective device(SPD) life tester, designed for on site testing of surge protection devices. It allows checking and indicating the health status of GDT/MOV based SPD of voltage range up to 1000V. It shall indicate the status of SPD by measuring its electrical parameters. SPD tester shall be of reputed make- Coble/JMV/Phoenix or superior. as per tech spec. (Inspection Agency-Consignee). | — | — | — | 2,12,711.52 | |
| — | 10.00 | — | — | ||
| Supply of Aluminium Ladders of height 5 feet for maintenance at Relay room and IPS room of make & Model: Total-THLAD08121 or superior.(Inspection Agency-Consignee). | — | — | — | 91,739.9 | |
| — | 15.00 | — | — | ||
| Supply of STANLEY 70-482 or superior 8'' Sturdy Steel Combination Plier Double Color Sleeve, Anti-Rust, Black Phosphate Finish, Material: C45, Full Body Hardened, Used for Gripping, Twisting, Bending and Wire Cutting.(Inspection Agency-Consignee). | — | — | — | 3,765 | |
| — | 15.00 | — | — | ||
| Supply of STANLEY 70-483 or superior 6'' Sturdy Steel Long Nose Plier Double Color Sleeve, Ergonomically Designed Dynagrip Handle with Finger Guards, Fully Heat Treated Forged Carbon Steel Jaws, Used to Cut Small Wires.(Inspection Agency-Consignee). | — | — | — | 3,825 | |
| — | 15.00 | — | — | ||
| Supply of STANLEY 84-214-22 or superior 130mm/5.25'' Wire Stripper with Range 0.5mm-4mm, Convenient Hole for Looping/Bending Wires, Ideal for Cutting, Stripping Speaker Wire, Appliance Cords.(Inspection Agency-Consignee). | — | — | — | 4,485 | |
| — | 6.00 | — | — | ||
| Supply of Road signal complete with signal post CLS unit 3 aspect ,ladder ,Base , LED signals & Hooter etc.(Inspection Agency-Consignee). | — | — | — | 3,35,857.14 | |
| — | 65.00 | — | — | ||
| Supply and installation of earth electrode as per standard practice and as per NCR latest practice. It includes supply of GI pipe of 3 meter length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 meter deep and fixing earth electrode pipe, casting of cement concrete enclosure with cover (cover as per NCR latest practice). It includes installation of 7 strand GI wires as earth lead wires, supported on MS flat size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge. (Inspection Agency-Consignee). | — | — | — | 2,17,980.1 | |
| — | 3.00 | — | — | ||
| Supply, Installation and commissioning of active lightning arrestor of Class 'A' for building protection as per statndard NFC-17-102 :2011 or latest. It shall work on early streamer emission principle. It shall be made of stainless steel with an opearting time of 60 microsecond or less. A non-resettable counter shall be provided to count the number of lightning occurences. The device shall be installed on top of the building on a GI mast and shall be connected to the earth pit through a copper tape of 25mm x 2mm or better. The copper tape shall not touch the building throughout and shall be connected to the earth electrode by exothermic welding.(Inspection Agency-Consignee). | — | — | — | 3,35,155.08 | |
| — | 6.00 | — | — | ||
| Supply, fabrication and fixing of the Calling On board/BSLB board as per RDSO Drg. no. SA 2373 (Adv)/Stop/Warning board as per drg. no SA-2380 (Adv), or as applicable, on concrete foundation and painting with Retro reflective paint. All work to be carried out as per Railway site engineer instructions.(Inspection Agency-Consignee). | — | — | — | 48,652.68 | |
| — | 18.00 | — | — | ||
| Supply, fabrication and fixing of Retro reflective Signal number plates as per NCR latest practice, on signal post with contractor's own material like clamp, U bolts, nuts etc.(Inspection Agency-Consignee). | — | — | — | 13,401 | |
| — | 400.00 | — | — | ||
| Supply and fixing of RCC cable route marker, made with concrete in the ratio 1:3:6, engraved "NCR" "S&T" on top portion and painted on both sides, along the route at every 50 meter and at route diversion. The cable marker is to be fabricated as per RDSO drawing no. SDO/cable laying/020, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest. The fixing work is to be done as per extant practice of INC Railway and as per Railway site supervisor incharge.(Inspection Agency-Consignee). | — | — | — | 1,71,544 | |
| — | 3.00 | — | — | ||
| Supply and installation of Cable Termination(CT) rack as per drawing of NC Railway, complete along with fitting arrangements, wall supports, scaffolding and suitable grouting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals/ ARA terminals. The CT rack shall be covered with hylum sheet of minimum 10 mm thickness for fixing of 8-way terminal strips/ Screw less terminals/ ARA terminals. Supply of 8 way terminal strips/ Screw less terminals / ARA terminals not covered under this item. Cable termination rack shall be corrosive resistant and powder coated.(Inspection Agency-Consignee). | — | — | — | 1,41,440.52 | |
| — | 3.00 | — | — | ||
| Supply, Installation, testing and commissioning of Sliding type mechanical Boom barrier (SBB) assembly, 11 to 12 Meter Long, movement drive; mechanism, resetting & supporting stand suitable for Mechanical/Electrical level crossing gate as an emergency arrangements as per GZB Workshop drawing no. SA-SWG/GZB/E/01. The sliding boom assembly should be have the provision of 50mmx50mmx50mm angles for the entire length. Boom rest posts should be 10 no per gate or more as per site requirement. Painting should be completely done of all the assemblies/parts of Sliding LC gate.(Inspection Agency-RITES). | — | — | — | 5,16,192.87 | |
| — | 3.00 | — | — | ||
| Supply, wiring, installation and commissioning of Earth Leakage Detector (ELD) having 6 digit counter, 12 Channel bus bar, voltage of 110V/60V/24V/12V in AC/DC measurement as per RDSO Spec. RDSO/SPN/256/2025 Version 2.0. This includes supply of fuse terminal strip for incoming power supply wires. Installation to be done on 19 inch sub rack along with insulation resistance meter, remote indication and buzzer in ASM room.(Inspection Agency-RDSO). | — | — | — | 5,73,766.68 | |
| — | 18.00 | — | — | ||
| Fabrication, supply and fixing of 'P', 'C', 'A', 'G', 'IBS' etc. marker disk painted and lettered with enamelled paint of approved colours, on signals, conforming to RDSO Drg. No.SA - 23456, as per standard practice and technical specifications.(Inspection Agency-Consignee). | — | — | — | 9,281.88 | |
| — | 3.00 | — | — | ||
| Supply, Installation, testing and commissioning of automatic fire detection & alarm system No. as per Spec. RDSO/SPN/217/2021 ver. 3.0 or latest over Jhansi Division, as detailed in Annexure 'A'. This Work includes complete installation & Commissioning of the system. All material required for complete installation and commissioning of the system will be supplied by the firm & all material to be procured from RDSO approved firms only. (Warranty period-24 months from the date of commissioning of that particular location).(Inspection Agency-RITES). | — | — | — | 10,62,501.12 | |
| — | 3.00 | — | — | ||
| — | — | — | 19,128.72 | ||
| — | 6.00 | — | — | ||
| Supply and installation of Almirah Steel shelving cabinets of Geeken as per attached specification.(Inspection Agency-Consignee). | — | — | — | 1,62,000 | |
| — | — | — | 57,33,200.89 | ||
| — | 3.00 | — | — | ||
| Installation of Relay Rack Assembly including IDF pillars if any complete with wall supports, scaffolding, ladders. runway for cables, fixing of Relay/ Relay group base plates, fixing of Tag blocks etc. The work shall be done as per approved plan, extant practice on NCR & the instructions of Rly engineer at site. | — | — | — | 31,257.6 | |
| — | 3.00 | — | — | ||
| Installation, testing and commissioning of Micro Processor based Remote Terminal Unit (RTU) with 128 digital input and 32 analog input as per RDSO Spec. No. IRS (S) 99/2006 (Amdt. 3) or latest . It includes supply of all the items required for complete indoor relay room wiring from RTU to relay rack tag blocks, drawing/extension of power supply up to RTU. It includes supply of relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD (if installed) , IPS, interlinking and networking of RTU. It also includes installation of leased line MODEM and other interfacing cards, if required for networking of RTU. Note: Total numbers of relays and other signalling functions/gears required to be wired as per list circulated vide RDSO Letter No.STS/E/Data logger dtd.12.09.2011 or latest guidelines.( | — | — | — | 98,557.95 | |
| — | 3.00 | — | — | ||
| Installation, testing and commissioning of electrically operated lifting barrier, complete with casting of cement concrete foundation for pedestal and boom rest post, cabling, power supply connection, earthing of barriers & wiring with complete outdoor work as per approved drawing, wiring etc. | — | — | — | 1,66,989.78 | |
| — | 216.00 | — | — | ||
| Laying and fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 ( Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dial hole, or at any other locations as decided by Site Engineer. The GI pipe is to be filled with chattered compound. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. The laying and fixing to be done as per RDSO drawings no. SDO/cable laying/011 and SDO/cable laying/012 issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014, or latest. | — | — | — | 78,090.48 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .