Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹35.1 LAdmitted-Finance 1ST FLOOR H NO 29 A SESHAADHRI NILAY NEOG PATH ANANDA NAGAR BEHIND DONA PLANET GS ROAD GUWAHATI 05 ASSAM | ₹35.1 L | Admitted-Finance |
| 2 | ₹35.4 LAdmitted-Finance | ₹35.4 L | Admitted-Finance |
| 3 | Rejected-Technical PLOT NO 13 SHAKTI KHAND II INDRAPURAM GHAZIABAD 201014 | GHAZIABAD | UTTAR PRADESH | 201014 | - | Rejected-Technical EMD can not be exempted based on expired Startup certificate |
| 4 | Rejected-Technical A T ROAD EVERLITE HOUSE PANITOLA LAIPULI TINSUKIA ASSAM 786183 UDYAM AS 26 0000672 | TINSUKIA | ASSAM | 786183 | - | Rejected-Technical the EMD can not be exempted for works contract |
| 5 | Rejected-Technical | - | Rejected-Technical Technically not acceptable. |
| Sl No | Description | Qty | Unit | Power Tools and Engineering | BORA ELECTRICALS |
|---|---|---|---|---|---|
| 1.00RMU and remote control panel | |||||
| 1.01 | Design, manufacture, manufacturer’s factory testing, supply, installation, and commissioning of 630A, 11 KV, Ring Main Unit (RMU) Outdoor type with VCB, SF6 gas-insulated switchgear panel complete with all accessories including associated equipment. Panel fabricated out of min. 2 mm thick CRCA powder (minimum thickness of powder coating shall be 80 micron) coated.The outdoor RMU panel to be complete with its panel, CTs (30:5/1), PTs and numerical protection relays such as overcurrent/earth fault, under voltage/overvoltage relays, broken conductor protection, DC supply monitoring relay, Master trip relay, Auxiliary relays for transformer protections such as buchholz (alarm &trip). The panel may also have an in-built DC power pack for providing control supply for control & protection.
(As per ONGC specification) | 3 | Nos | 14,85,660 ₹17.5 L | 19,72,881 ₹23.3 L |
| 1.02 | Supply, fixing, testing and commissioning of indoor mounting control panel dust and vermin proof wall mounting, fabricated out of min. 2 mm thick CRCA powder coated sheet steel suitable for use at 110V DC/ 24V DC with ON/OFF/TRIP (Red/Green/Amber) LED indicating lamps, DC supply healthy indicating lamp, ON/OFF push button with 2A SP MCB backup protection with din bar, terminal along with interconnections with 2.5 sq mm flexible unarmoured copper wire. | 3 | Nos | 7,43,160 ₹8.8 L | 30,762 ₹36,299.16 |
| 2.00Supply of cable | |||||
| 2.01 | Supply of 3C ×95 sq mm 11 KV grade armoured cross linked polyethylene cable(aluminium) | 240 | M | 2,04,240 ₹2.4 L | 3,07,200 ₹3.6 L |
| 2.02 | Supply of 10C×2.5 sq mm XLPE insulated (Heavy Duty) armoured electrical control cable with copper conductor for working voltage upto & including 1.1 KV conforming to IS:7098/Part-I with latest amendments, Make: Gemscab/Havells/ RR-kabel /NICCO/ Grandlay/Glostar/finolex/HPL/Delton/Plaza/KEI/Polycab. | 200 | M | 87,600 ₹1.0 L | 97,200 ₹1.1 L |
| 2.03 | Supply of 4x2.5 sq mm XLPE insulated armoured electrical cable with copper conductor for working voltage upto & including 1.1 KV conforming to IS:7098/Part-I with latest amendments, Make: Gemscab/Havells/ RR-kabel /NICCO/ Grandlay/Glostar/finolex/HPL/Delton/Plaza/KEI/Polycab. | 280 | M | 53,480 ₹63,106.40 | 62,440 ₹73,679.20 |
| 3.00Cable laying (HV) | |||||
| 3.01 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 8.1.1 Upto 120 sq. mm | 90 | M | 22,500 ₹26,550 | 42,750 ₹50,445 |
| 3.02 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 120 sq. mm | 90 | M | 22,500 ₹26,550 | 29,340 ₹34,621.20 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹71,000
Closing Date
24 Feb 2026, 3:00 pmClosed
Pankaj Malik
2nd floor, Dhansiri Bhawan, ONGC Cinnamara Complex, Jorhat 9968602180
SITC of 11 KV RMU outdoor panel with associated work in Surface Installations of Jorhat Asset
2026_ONGC_264644_1
JOR /JOA/ MM/2025/ 2669853/ L46PC26003
Open Tender
Electrical Works
120 days
GGS/GCP Borholla, Nambar GGS and Khoraghat GGS-I
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹71,000
Yes
6 May 2026
29 Jan 2026
25 Feb 2026
29 Jan 2026
24 Feb 2026
12 Feb 2026
29 Jan 2026 - 5 Feb 2026
RMU and remote control panel
Design, manufacture, manufacturer’s factory testing, supply, installation, and commissioning of 630A, 11 KV, Ring Main Unit (RMU) Outdoor type with VCB, SF6 gas-insulated switchgear panel complete with all accessories including associated equipment. Panel fabricated out of min. 2 mm thick CRCA powder (minimum thickness of powder coating shall be 80 micron) coated.The outdoor RMU panel to be complete with its panel, CTs (30:5/1), PTs and numerical protection relays such as overcurrent/earth fault, under voltage/overvoltage relays, broken conductor protection, DC supply monitoring relay, Master trip relay, Auxiliary relays for transformer protections such as buchholz (alarm &trip). The panel may also have an in-built DC power pack for providing control supply for control & protection. (As per ONGC specification)
Supply, fixing, testing and commissioning of indoor mounting control panel dust and vermin proof wall mounting, fabricated out of min. 2 mm thick CRCA powder coated sheet steel suitable for use at 110V DC/ 24V DC with ON/OFF/TRIP (Red/Green/Amber) LED indicating lamps, DC supply healthy indicating lamp, ON/OFF push button with 2A SP MCB backup protection with din bar, terminal along with interconnections with 2.5 sq mm flexible unarmoured copper wire.
Supply of cable
Supply of 3C ×95 sq mm 11 KV grade armoured cross linked polyethylene cable(aluminium)
Supply of 10C×2.5 sq mm XLPE insulated (Heavy Duty) armoured electrical control cable with copper conductor for working voltage upto & including 1.1 KV conforming to IS:7098/Part-I with latest amendments, Make: Gemscab/Havells/ RR-kabel /NICCO/ Grandlay/Glostar/finolex/HPL/Delton/Plaza/KEI/Polycab.
Supply of 4x2.5 sq mm XLPE insulated armoured electrical cable with copper conductor for working voltage upto & including 1.1 KV conforming to IS:7098/Part-I with latest amendments, Make: Gemscab/Havells/ RR-kabel /NICCO/ Grandlay/Glostar/finolex/HPL/Delton/Plaza/KEI/Polycab.
Cable laying (HV)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 8.1.1 Upto 120 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 120 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Upto 120 sq. mm .
Cable laying (MV)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following sizeon wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle)
Civil works
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
HV CABLE JOINTING & END TERMINATION
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Upto 35 sq. mm
Earthing
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following sizeon wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle)
Cable glands
Supply and fixing of Brass compression gland for (25 mm) 10X 2.5sq. mm 1.1 KV grade cable with making of hole in cubicle panel
Supply and fixing Brass compression gland (19 mm) for 3 X 2.5 sq. mm 1.1 KV grade cable with making of hole in cubicle panel
Cable route marker
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Distribution Board & Blinking Plate
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
Blanking plate
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 25 A
Wiring
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group A
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required: 15/16 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required: 6 pin 15/16 A socket outlet
Light Fixture
Supply of LED tubelight,Decorative,Ultraslim linear LED fixture with tube
Please Enable Macros to View BoQ information
BIDDER RESPONSE SHEET
Name of the Bidder/ Bidding Firm / Company :
Please enter your response in yellow coloured cells only
RMU and remote control panel
Design, manufacture, manufacturer’s factory testing, supply, installation, and commissioning of 630A, 11 KV, Ring Main Unit (RMU) Outdoor type with VCB, SF6 gas-insulated switchgear panel complete with all accessories including associated equipment. Panel fabricated out of min. 2 mm thick CRCA powder (minimum thickness of powder coating shall be 80 micron) coated.The outdoor RMU panel to be complete with its panel, CTs (30:5/1), PTs and numerical protection relays such as overcurrent/earth fault, under voltage/overvoltage relays, broken conductor protection, DC supply monitoring relay, Master trip relay, Auxiliary relays for transformer protections such as buchholz (alarm &trip). The panel may also have an in-built DC power pack for providing control supply for control & protection. (As per ONGC specification)
Supply, fixing, testing and commissioning of indoor mounting control panel dust and vermin proof wall mounting, fabricated out of min. 2 mm thick CRCA powder coated sheet steel suitable for use at 110V DC/ 24V DC with ON/OFF/TRIP (Red/Green/Amber) LED indicating lamps, DC supply healthy indicating lamp, ON/OFF push button with 2A SP MCB backup protection with din bar, terminal along with interconnections with 2.5 sq mm flexible unarmoured copper wire.
Supply of cable
Supply of 3C ×95 sq mm 11 KV grade armoured cross linked polyethylene cable(aluminium)
Supply of 10C×2.5 sq mm XLPE insulated (Heavy Duty) armoured electrical control cable with copper conductor for working voltage upto & including 1.1 KV conforming to IS:7098/Part-I with latest amendments, Make: Gemscab/Havells/ RR-kabel /NICCO/ Grandlay/Glostar/finolex/HPL/Delton/Plaza/KEI/Polycab.
Supply of 4x2.5 sq mm XLPE insulated armoured electrical cable with copper conductor for working voltage upto & including 1.1 KV conforming to IS:7098/Part-I with latest amendments, Make: Gemscab/Havells/ RR-kabel /NICCO/ Grandlay/Glostar/finolex/HPL/Delton/Plaza/KEI/Polycab.
Cable laying (HV)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 8.1.1 Upto 120 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 120 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Upto 120 sq. mm .
Cable laying (MV)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following sizeon wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle)
Civil works
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
HV CABLE JOINTING & END TERMINATION
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Upto 35 sq. mm
Earthing
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required Upto 35 sq. mm
Laying and fixing of one number PVC insulated and PVCsheathed / XLPE power cable of 1.1 KV grade of following sizeon wall surface as required Upto 35 sq. mm (clamped with 1mm thick saddle)
Cable glands
Supply and fixing of Brass compression gland for (25 mm) 10X 2.5sq. mm 1.1 KV grade cable with making of hole in cubicle panel
Supply and fixing Brass compression gland (19 mm) for 3 X 2.5 sq. mm 1.1 KV grade cable with making of hole in cubicle panel
Cable route marker
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Distribution Board & Blinking Plate
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
Blanking plate
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 25 A
Wiring
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group A
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required: 15/16 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required: 6 pin 15/16 A socket outlet
Light Fixture
Supply of LED tubelight,Decorative,Ultraslim linear LED fixture with tube
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.32 MB
TenderDocumentRMUOutdoorPanel.pdf
Tender Documents • 1.66 MB
BOQ_307102.xls
BOQ • 0.40 MB
BidderResponsesheet.xls
Additional Documents • 0.05 MB
Download all tender documents and submit your bid