| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC B4 60 1 NEW SANTOSHPUR THANDER PARA STATION ROAD 24 PARGANAS SOUTH PIN 700142 WB | 24 PARAGANAS SOUTH | WEST BENGAL | 700142 | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹50.0 L+₹1.8 L (3.76%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹53.6 L+₹5.4 L (11.2%)Rejected-Finance 0 GANGARAM DHARMKANTA TRUCK UNION JIROTA KALAN DAUSA DAUSA RAJASTHAN 303303 | DAUSA | RAJASTHAN | 303303 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹53.7 L+₹5.5 L (11.4%)Rejected-Finance 38 BAGUIATI ROAD KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹54.1 L+₹5.9 L (12.3%)Rejected-Finance BMC 1 54 GANTI NETAJI PALLY PO GANGANAGAR KOLKATA 700 132 INDIA | 24 PARAGANAS NORTH | WEST BENGAL | 700132 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
13 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPARI TO BLDG NO F-2 IN OLD BAPU LINE AND SPL REPAIR WKS FOR SEWAGE LINE AT BLDG NO BI-4 (ROYAL BK) INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2022_MES_570849_1
8959/FW/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender ducuments
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹89,000
1 Feb 2023
23 Dec 2022
14 Jan 2023
23 Dec 2022
13 Jan 2023
6 Jan 2023
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches of 150 mm internal dia complete all as specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) 200 mm set in cement mortar complete all as specified and as directed.
All as per Item No. 03 above, but for demolition and breaking up drain pipes 300 mm bore drain pipes
S&F in repair Cast iron (Spun Pipes) soil, waste and vent pipes 100 mm bore of any length with or without ears with cement joints all as specified laid in trenches or in floors complete all as specified and directed.
All as per item No.04 above, but100 mm bore pipes fixed on walls
S&F in repair Cast iron (Spun Pipes) soil, waste and vent pipes 75 mm bore of any length with or without ears with cement joints all as specified laid in trenches or in floors complete all as specified and directed.
All as per item No.06 above, but 75 mm bore pipes fixed on walls
S&F in repair CI Spun bends for 100mm pipe (any radius) diminishing piece or tapers (large bore measured) complete all as specified and directed.
S&F in repair 100 mm bore cast iron (Spun) bends with access door (any radius), diminishing pieces or tapers (larger bore to be measured) complete all as specified and as directed.
S&F in repair CI Spun branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parellel branches, for 100mm dia pipe complete all as specified and directed.
S&F Cast Iron Spun Branch Piece 100mm bore (dia) single (equal or unequal), ordinary or inverted (spigot or socket type) with Parallel Branches fitted with Oval Access Door including Jointing with Cement Mortar 1:1, fixed complete all as specified and directed.
S&F 100mm bore cast iron Spun cowls complete all as specified and directed.
S&F in repair CI Spun bends for 75mm pipe (any radius) diminishing piece or tapers (large bore measured) complete all as specified and directed.
S&F in repair 75 mm bore cast iron (Spun) bends with access door (any radius), diminishing pieces or tapers (larger bore to be measured) complete all as specified and as directed.
S&F in repair CI Spun branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parellel branches, for 75mm dia pipe complete all as specified and directed.
S&F Cast Iron Spun Branch Piece 75mm bore (dia) single (equal or unequal), ordinary or inverted (spigot or socket type) with Parallel Branches fitted with Oval Access Door including Jointing with Cement Mortar 1:1, fixed complete all as specified and directed.
S&F 75mm bore cast iron Spun cowls complete all as specified and directed.
S&F in repair 75 mm OD PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F in repair 110 mm OD PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius for 75 mm OD pipe complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius for 110 mm OD pipe complete all as specified and directed.
Supply and laying 300 mm bore reinforced concrete pipe of Class NP-2, laid and jointed with jute & cement mortar 1:2, complete with collars all specified and as directed.
All as per Item No. 22 above, but 200 mm bore RCC pipe
All as per Item No. 22 above, but 150 mm bore RCC pipe
M&L concrete bed to drain pipe including packing under and haunching against the side of drain pipe after laid and tested in PCC 1:3:6 type C2 for 300 mm bore pipes complete all as specified and directed.
All as per Item No. 25 above, but PCC bed for 200 mm bore pipe
All as per Item No. 25 above, but PCC bed for 150 mm bore pipe
All as per Item No. 25 above, but PCC bed for 100 mm bore pipe
Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate), finished smooth and reforming benching for 150 mm bore pipe as required and as directed by the Engineer-in-Charge.
Excavation in over areas n exc 1.50 m deep and getting out as in any type of soils, complete all as Specified and as directed.
Excavation in trenches n exc 1.50 m wide and n exc 1.50m depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes etc not exc 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in soft/loose Soil, complete all as Specified and as directed.
All as per Item No. 31 above, but in road/hardstanding etc and getting out
Returning filling in incl spreading , levelling , watering and well ramming in layers not exc 25 cm as in soft/ loose Soil, complete all as Specified and as directed.
Removing excavated materials not exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as Specified and as directed.
Cutting of existing RCC hume pipe, any size and at any depth for construction of new manhole in existing line of size as per site requirement including repairing of edge of RCC hume pipe with cement mortar 1:1 and removal of cut portion of pipe from site complete all as specified and directed. (NOTE: Items for manhole & earthwork, excavation in hard surface/black top surface etc shall be measured and paid seperately)
S&F in repair RCPC (Reinforced Cement Polymer Concrete) grating slab of size 900 mm x 450 mm x 75 mm thick, of Capacity 5 MT fixed in proper position complete as directed by Engr-in -Charge.
S&F in repair RCPC (Reinforced Cement Polymer Concrete) grating slab of size 600 mm x 450 mm x 75 mm thick, of Capacity 3 MT fixed in proper position complete as directed by Engr-in -Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 150 mm thickness (above or below groud level) complete all as specified and directed.
Demolition Cement Concrete (un-reinforced) in Ground Floors and Paving not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed.
M&L for providing Plain Cement Concrete (1:4:8) type D2 using 40mm graded stone aggregate as in sub base of floor, etc complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded stone aggregates as in surface channels and drains including necessary form work complete all as specified and directed.
M&L Cement Concrete type C2 (1:3:6) using 40mm graded crushed stone aggregate 75mm thick as in Plinth Protection, / sub bases etc. laid in alternate Bays, finished Concrete Surfaces Even and Smooth without using Extra Cement, complete all as specified and as directed.
M&L for 25 mm thick plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in sub base of floors etc, finished evan and fair complete all as specified and directed.
M&L Sand filling under floors under paver block, thickness not exc 40 mm including consolidation complete all as specified and as directed
Supply and laying in repair 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; including taking out of existing paver block complete all as specified and directed. (NOTE: Cost of sand cushioning is deemed to be included in the quoted rates)
S&F in position, at or near ground level, factory made precast cement concrete kerb stone blocks, in M-25 grade cement concrete, fixed to the required line, level and curvature, jointed in cement mortar 1:3, including making joints with or without grooves (thickness of joints, except at sharp curves shall not be more than 5 mm) including making drainage opening wherever required complete all as specified and directed.
M&L for Cement Concrete type B-1, (1:2:4) using 20mm graded crushed stone aggregate in copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including use and waste formwork (straight or curved) complete all as specified and as directed.
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc completed all as specified and directed.
Add or deduct from serial item No 49 here-in-before for each 25 mm girth or part thereof over or under 30 cm for forming fair finished drain or channel in cement concrete, using extra cement including forms, moulds, mitered /stopped ends etc complete all as specified and directed.
Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including racking out joints, hacking for key, scrubbing down with Water, remove dust, debris/ rubbish, etc., complete all as specified and as directed.
M&L 15 mm thick rendering in cement mortar (1:6) to brick or concrete wall surfaces, finished even and smooth without using extra cement complete all as specified and as directed.
M & L for 20 mm thick plastering in two layers, 10 mm + 10 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only".
M & L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only".
M&L for rendering 5mm thick on ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement, with and including necessary scaffolding, complete all as specified and directed.
Supply only liquid water proofing compound all as specified and as directed.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ fly-ash Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
ditto item No. 57.00 above but except bricks complete all as specified and directed . (Note: Serviceable bricks obtained from demoition shall be reused)
M&L Brick Work with Sub-Class ‘B’ fly-ash Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed.
S & F in repair Cast iron work grade FG -150 unmachined in brackets, gratings, railing, frames, manhole covers and similar articles, weight n exc 5 Kg each complete all as specified and as directed.
Supply and fix MS angle, or tee section etc., fixed independently without connnecting plates etc., but ordinary lengths, confirming to FE-410- W(Gde-E-250) quality-A, as in fencing posts including holes for nuts and bolts and similar works, complete all as specified and as directed.
M&L in repair mild steel in framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 all as specified and directed by Engineer-in-Charge.
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe-410-W (Gde-E 250) quality-B complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
S&F Non Skid joint free coloured tiles 7-8mm thick area of each tiles exc 0.11Sqm but n. exc 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and incl 15mm thick screed bedding in cement mortar 1:6 complete all as a specified and as directed
S&F coloured glazed ceramic tiles in vertical surfaces 450 X 300 X 7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match, fixed over and incl 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Cleaning of existing covered / uncovered (partly / semi or fully filled up) drain, of any opening width and depth by removing and re-fixing of cover-slab (wherever applicable) taking out accumulated silt, mud, earth, rubbish, vegetation etc from the drain, washing of the drain with water and removing the same to a distance outside MOD complete all as directed by the Engineer-in-Charge.
Taking up or down existing 15mm dia steel tubing and connection and keeping saide for re-fixing or removal to store complete all as specified and directed
Taking up or down existing 20mm dia steel tubing and connection and keeping saide for re-fixing or removal to store complete all as specified and directed
Supplying, fixing, jointing and testing 20mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings laid in trenches/floors or fixed on walls/ceiling complete all as specified and directed.
Supplying, fixing, jointing and testing 25mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings laid in trenches/floors or fixed on walls/ceiling complete all as specified and directed.
S&F in repair Gun metal gate or globe valve, with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm bore pipe complete all as specified and directed.
Dismantling of AC corrugated/semi corrugated sheets including ridge as in roof covering and removing off the site complete all as specified and directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
All as per Item No. 74.00 above but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
Cleaning of blocked nahni/floor trap (of any size/type), sink/urinal/wash basin including connected pipelines, any type or bore upto gully trap/1st manhole and well flushing with water complete all as specified and as directed by the Engineer-in-Charge.
Cleaning of Manhole chamber of any size, upto depth 1.0 metre each, mechanically, removing muck/sludge/silt/mud, liquid etc under any position including foul condition and cleaning the inlet and outlet with water, placing back the manhole cover in position and disposing off the sludge/debris out of MOD land complete all as specified and directed.
All as per Item No. 77 above, but for mechanical cleaning of manhole of depth exc 1.0 m but not exc 2.0 m
Taking up/down plants or vegetation growth wall upto roof level by means of cutting hole into brickwall and making good the surface of dismatled portion (not exc 150 sqm cm superficial area and not exc one brick depth) using brick bats/aggregate and plastering in cement mortar (1:4) to distributed portion and applying two coat of cement base paint to match existing surface up to fourth floor complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description in any position not otherwise specially provided for complete all as specified and as directed..
M & L for Providing precast reinforced cement concrete Type B1 1:2:4 (20mm graded aggregate) Set in cement mortar 1:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including necessary forms, moulds, etc complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) (nominal mix) type B1 using 20 mm graded aggregates in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) for fair finished surfaces complete all as specified and directed.
M&L Mild steel TMT bars 10 mm dia & over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and directed.
S&F Mild steel TMT bars 6-8 mm dia , cut to length and bent to shape as reqd, including cranking , bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia complete all as specified and directed .
S&F in repairs Vitreous china, white, half stall urinal flat back with grating and union for discharge pipe (excl flush pipe and flushing cistern) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing flush pipe, grating and Union for discharge pipe incl providing 32mm bore PVC discharge pipe complete all as specified and directed. (Make of Urinal : CERA, Model: CARYS / HINDWARE, Cat No: CORTO / PARRYWARE, Model: Aquaseal N )
S&F in repair vitreous China Squatting pan ‘Orissa’ pattern, size 580 X 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, etc and including making good to floor, complete all as specified and directed. (MAKE : PARRYWARE, Cat No. C0117 / HINDWARE, Cat No. 20004 / JAQUAR, Cat No. CNS-WHT-OP01 / CERA, Model: COVY)
S&F in repair White PVC Flushing Cistern 10 Litre capacity, Low Level Valve Less, Syphonic Action type with Inlet, Ball Valve, Float, flush pipe and Handle including Cutting and pinning in Ends, making good disturbed Surfaces in Cement Mortar 1:3 and fixed including taking down/out unserviceable Flushing Cistern and connected items complete all as specified and directed. (MAKE : PARRYWARE, Model : Slim line Economy / HINDWARE, Model : Sleek Plus / CERA, Model : Corona / PRAYAG, Model: SMART or equivalent model in COMMANDER )
S&F in repairs vitreous china (white) wash down water closet pan (pedestal pattern) with 'P' or 'S' trap front or back inlet, fixing bolts (except flushing cistern and flush pipe) incl plastic water closet seat cover (white) and mild steel chromium plated or aluminium hinging device complete all as specified and directed. (Make : Parryware, Model : Elite / JAQUAR, Model: Continental / CERA, Model: Conventional / HINDWARE, Model: SLICK)
Chipping of unsound /weak concrete materials including cover plaster from RCC structural member i.e. slabs, beams, columns, lintel, chajja, fins, facia etc. of 25 mm average thickness (Any storey/ height of building/ structure) including tapering all edges, making square shoulders of cavities by air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting including removal of foreign materials, loose concrete/aggregate etc and disposal of all debris out side of MOD land and complete all as specified and as directed by Engr-in-Charge.
Deduct / Add for below / over 5mm or part thereof thickness for item No 101 above (Any storey/ height of building/ structure)
Material , labour and applying of high efficiency polymeric resin base film forming curing agent/compound over concrete surface and maximum coverage area 5.00 Sqm per litre as per manufacturers instruction (for any storey/ height of building/ structure) complete all as specified and as directed. (Make: Concure LP90 of FOSROC or equivalent product in other makes specified in tender)
M&L for applying two component structural grade polymer modified reinstatement mortar of compressive strength, flexural strength shall not be less than 45 MPa at 28 days, 7 MPa at 28 days respectively (maximum coverage area 1.30 sqm per 25 kg pack @ 10mm thickness) over a coat of epoxy bonding agent on existing surface for strengthening of beams, columns and other structural element of average thickness 25 mm and mortar shall be applied in layer not exc 6 mm thick in layers and including surface preparation as per manufacturer's instructions complete all as specified and directed (any storey / height of building / structure). (Make: Rendroc S2 of FOSROC or equivalent product in other makes specified in tender)
S&F steel window with side hung shutters including necessary hinges with steel handles and steel peg stay complete with glazing bars devotailed or welded, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, steel window or stone concrete or brick surrounds glazed with putty or fixed with beads complete all as specified and directed.
S&F 4.0 mm sheet glass ordinary quality in wooden frame with putty/beads in square n. exc 0.5 Sqm in each pane complete all as specifed and directed
S&F in repair 15mm bore heavy duty PVC connector pipe of length 600mm with PTMT coupling at both ends, screwed down for pipe as directed. (MAKE : PRAYAG, Cat No. 324 / POLYTUF, Cat No. 4004-D / SHAKTI, Cat No: SB 1324-D)
S&F for 2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, moulded or chamfered, put together with glue, pinned at joints complete all as directed.
S&F Factory made 35mm thick with 2nd class hard wood, rail and style factory made plain framed panelled shutter(two panel) with lock, rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35mm thick factory made 2nd class hard wood glazed & skleton shutters, open rebated and prepared to received glass, gauge etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as directed.
S&F stainless steel wire cloth of 0.65mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F stainless steel wire cloth of 0.65mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, as in repairs, complete all as specified and directed.
S&F 100mm butt hinges stainless steel medium weight complete all as specified and directed
S&F 75mm butt hinges stainless steel medium weight complete all as specified and directed
S&F aluminium handle, cast type anodised 125 mm size complete all as spcified and as directed.
S&F aluminium handle, cast type anodised 150 mm size complete all as spcified and as directed.
S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 200mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, all as directed complete all as specified and directed.
S&F 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, as in repairs, all as directed complete all as specified and directed.
Preparing new surface of wood or wood based material of any description and in any position not otherwise described n.exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wood primer complete all as directed.
M&L for applying two coats of synthetic enamel paint over a coat of Red oxide, zinc chrome primer to new steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L for applying one coat of synthetic enamel paint on old treated wooden surfaces of any description over 10cm width or girth including cleaning and preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for applying one coat of synthetic enamel paint on old treated steel surfaces of any description over 10cm width or girth including cleaning and preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered of wall surfaces and applying two coats of acrylic distemper over a coat of alkali resistant primer applied over 3 mm thick wall care putty complete all as specified and directed.
M&L for preparation of new plastered of wall surfaces and applying two coats of acrylic distemper over a coat of alkali resistant primer, complete all as specified and directed.
M&L Preparing new Surfaces of wall and applying Three coats of white wash complete all as specified and as directed.
M&L Preparing new Surfaces of ceilings and applying Three coats of white wash complete all as specified and as directed.
M&L Preparing old decorated surfaces of Walls and applying one coat of white wash, complete all as specified and as directed.
M&L for complete removal of existing treatment of wall surfaces and applying two coats of acrylic distemper over a coat of alkali resistant primer applied over 1.5 mm thick wall care putty, complete all as specified and directed.
M&L for preparation of old decorated wall surfaces and applying one coat of cement base paint complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
S&F 20 mm bore Ball brass valves, high pressure, with HDPE float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. (MAKE : PRAYAG, Cat No. B-152 or equivalent model in JEXON / POLYTUF / SHAKTI)
M&L for uprooting of tree from walls of bldgs up to extended root and spraying of muratic acid of required quantity complete from any location of bldg, up to four storey height and making good disturbed surface with cement mortar (1:4) or cement concrete type C1 (1:3:6) using 20 mm graded stone aggregate etc complete all as specified and directed.
S&F in repair Chromium plated brass Bib cock with wall flange (premium quality), fancy type, long body, fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: FUS-29037 / CERA, Cat No: F1015151/ ASIAN PAINTS, Cat No: ALBC101 / PRAYAG, Cat No: 9306-N/HINDWARE, CAT No: F360004 or equivalent model in PARRYWARE)
S&F 15 mm bore stop cock (surface type), cast copper alloy, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, as in repairs, complete all as specified and directed. (MAKE : ESSCO, Cat No : DLX-513A/513B / PRAYAG, Cat No : 7226/7228 or equivalent model SOMANY/ JAINKO)
S&F in repair Chromium plated brass two way Angular stop cock, fancy type, concealed type with wall flange fixed to 15 mm bore of Iron pipe, complete all as specified and directed. (Make : PARRYWARE, Cat No: T4643A1 / CERA, Model : OCEAN / PRAYAG, Cat No: 9011 / ESS ESS, Cat No: PT-04B)
S&F in repairs vitreous china (coloured) wash down water closet pan, Semi-pedestal pattern (Anglo-Indian type) with 'P' or 'S' trap front or back inlet, fixing bolts (except flushing cistern and flush pipe) incl plastic water closet seat cover (white) and mild steel chromium plated or aluminium hinging device complete all as specified and directed. (Make : Parryware, Model : Elite / JAQUAR, Model: Continental / CERA, Model: Conventional / HINDWARE, Model: SLICK)
Fixing only vitreous china (coloured) wash down water closet pan, Semi-pedestal pattern (Anglo-Indian type) with 'P' or 'S' trap front or back inlet, fixing bolts (except flushing cistern and flush pipe) incl plastic water closet seat cover (white) and mild steel chromium plated or aluminium hinging device complete all as specified and directed. (Make : Parryware, Model : Elite / JAQUAR, Model: Continental / CERA, Model: Conventional / HINDWARE, Model: SLICK)
S&F in repairs tubes 15mm bore "medium grade" galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
All as per item No. 130 here-in-before, but 20 mm bore
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris complete all as specified and as directed.
M&L for Providing Cement Concrete, Type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding, of thickness as required on site, finished even and fair complete all as directed by Engineer - in - charge .
M&L 10 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.10 litre per sqm over APP membrane.
Chipping of existing plaster manually from masonary or concrete surface using chisel and hammer and disposal of debris out of MOD land and depositing where directed at a level n'exc 1.5m above the starting point complete all as specified and as directed by Engr-in-Charge
Chipping of unsound /weak concrete materials from slabs , beams, columns ,lintel,chajja, fin , facia etc., by any means as upto 30mm average thickness for slabs/Chajjas including tapering all edges, making square shoulders of cavities air or sand blasting and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign matrials , loose concrete/aggregate etc., and disposal of all debries out of MOD land and complete all as specified and as directed by Engr-in-Charge.
All as per Item No 137 above, but 50 mm average thickness for beams/Lintel
All as per Item No 137 above, but 60 mm average thickness for Column
Add or deduct for every 10 mm thickness extra
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm clear air gap) by manual methods (using wire brushing ,chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area throughly by water and allow it to dry all as per manufacturer,s instruction to give it a totally rust free finished steel surface upto 12 mm dia, complete all as specified and directed by Engr-in-charge (Make : SIKA/ FOSROC)
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm clear air gap)by manual methods (using wire brushing ,chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area throughly by water and allow it to dry all as per manufacturer,s instruction to give it a totally rust free finished steel surface over and above 12 mm dia bars, complete all as specified and directed by Engr-in-charge (Make : SIKA/FOSROC)
M & L for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufactures instruction/ specification. The bonding agent shall have minimum compressive strength of 40 N/Sqmm and complete all as specified and directed by Engr-in-charge
Supply and application of Epoxy Zinc rich primer on the prepared steel surface by brush the primer shall have a minimium specific gravity 1.75 minimum weight film thickness / coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified and directed by Engr-in-charge. Make ; SIKA/FOSROC
M & L for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc., above 12 mm dia bars, all as specified and directed by Engr-in-charge.
M & L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc .of 50 mm average thickness on Beam and Slabs. The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days for and complete all as spd and dir by Engr-in-charge. (Make: SIKA / FOSROC / ELANTAS BECK / KUNAL CONCHEM)
All as per item No.146 above, but on Add or deduct for every 10 mm thickness
M&L for applying curing compound over concrete surfaces as per manufactures instruction complete all as specified and directed by Engr-in-charge
SCHEDULE 'A' PART-II (ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for reuse or removing from site and making good disturbed surface of walls, floors etc. complete all as specified and directed.
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for surface type point wiring with 1.50 Sqmm (nominal area) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and caping complete with all fittings and accessories (including sunken type pressed steel terminal box and laminate cover), fixed to walls/ceiling, for mounting switches/ regulator /bell push etc and including 1.50 Sqmm (nominal area) FRLSH PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly,. Complete all as specified and directed. for one light point / bell point/ceiling fan/exhaust fan point controlled by one way switch. (NOTE :- (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Point wiring shall be measured from switch board/DB to outlets only. Main circuit wire of the switch board/DB shall be measured and paid separately as sub main wiring of required size depending upon the load of that switch board. (iii) Quoted rate shall be exclusive of the cost of terminal box and laminate cover.
All as per item No 152 here-in-before, but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (including terminal box and laminate cover), fixed to walls/ceiling, for mounting switches.
All as per item No 152 here-in-before, but for one 5 pin 5/6 amps multi socket outlet point in independent board (including terminal box and laminate cover), fixed to walls/ceiling, for mounting switches.
All as per item No 152 here in before, but using 2.5 sqmm PVC insulated unsheathed multi strand copper cable (1100 V) FRLSH for line conductor and 1.5 Sqmm PVC insulated unsheathed multi strand FRLSH copper cable (1100 Volts) for earth continuity wire for one 15/16 amp multi socket out let independent (including terminal box and laminate cover), fixed to walls/ceiling, for mounting switches.
S&F switch piano flush button AC 230 V Single pole 5/6 Amp one way complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination, 5 pin, 6 Amp AC 230 Volts flush type complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 6 and 16 Amps flush type universal complete all as specified and directed.
S&F electronic type stepped speed regulator, 100 watts, AC 230 Volts for ceiling fan, complete all as specified and directed.
S&F ceiling rose surface, polycarbonate/Bakelite, three terminals complete all as specified and directed.
S&F in repairs surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size incl taking down existing fitting complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
All as per Item No.162 above, but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt
Supply and fixing TPN DB, IP 43 protection, double door (premium quality), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC/ C&S / HAGER)
Supply and Fix, Double Door, Sheet Metal Enclosure for DBs (Premium Quality), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : L&T / LEGRAND /ABB / SCHNEIDER / C&S/ HAGER)
S&F SPN DB, IP 43 protection, double door (Premium Quality), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T / LEGRAND/ ABB / SCHNEIDER/ C&S/ HAGER)
S&F MCB (premium quality), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / C&S/ HAGER)
S&F MCB (premium quality), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / C&S / HAGER)
S&F MCB (Premium Quality), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / C&S/ PANASONIC / HAGER)
Taking down Ceiling fan 1200 mm to 1400 mm sweep of any make sealing cable ends, dismantling blades, applying one coat of synthetic enamel paint by spraying after cleaning thoroughly with kerosene oil including filling cavities with filler etc, refixing the same in original position including provision of cable from ceiling rose or connector to fan, complete all as specified and as directed by Engr In Charge. (Note:-Cost of repairs / rewinding of motor will be measured and paid separately)
Supply and fixed in repair Capacitor 2.5 mfd, 230 Volts, AC, 50 Hz, complete all as specified and as directed.
Supply & fixed in repair MS down rod of size 15/20 mm dia and length 2' for ceiling fan including electric connection, nut, bolt and clamp as in repair complete all as specfied and directed.
Supply & fixed in repair MS down rod of size 15/20 mm dia and length 3' for ceiling fan including electric connection, nut, bolt and clamp as in repair complete all as specfied and directed.
Supply and fixed D clamp of strip size 25x6 mm with suitable washer, nuts, bolts in any shape or size as indicated or directed and inclusive of one primer coat ,one under coat, one finish coat of paint complete for hanging of ceiling fan all as specified and as directed.
Supply and fixing of rubber reel 1.7/2.5 insulator for Ceiling fan suitable for 1200/1400mm sweep complete all as specified and directed.
M&L for sub main wiring with two run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 Sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 Sqmm as earth continuity conductor drawn through and including PVC casing caping of suitable size, surface type, complete all as specified and directed. (NOTE : Three runs of single core 2.0 Sqmm cable & one run of PVC casing caping shall be measured as one unit)
M&L for sub main wiring with two run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 Sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 Sqmm as earth continuity conductor drawn through and including PVC casing caping of suitable size, surface type, complete all as specified and directed. (NOTE : Three runs of single core 4.0 Sqmm cable & one run of PVC casing caping shall be measured as one unit)
Supply, Laying, jointing and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable of sixe 10 Sqmm 4 Core, 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole incl necessary thimbles, as in repairs, complete all as specified and directed.
S&F exhaust fan 250 mm sweep, 1200 RPM, heavy duty, AC Single Phase 230/240 Volts, made with sturdy Engineering plastic body, louvers complete with all accessories and connecting up with and including twin core twisted flexible copper conductor cable of size 1.5 Sqmm (nominal area) from ceiling rose to fan complete all as specified and directed. (MAKE : HAVELLS/CROMPTON/ USHA/BAJAJ / ORIENT)
S&F in repairs LED Street Light fitting, of 35/36 W capacity, 230Volys AC Out door type, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver, top opening driver cover, IP 65/66 ingress protection, impact resistance of IK07 complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power Factor not less than 0.90 (e) having in built short circuit and surge protection upto 4 kV (f) having 10 KV external surge protection (for 45 watt & above) (g) colour temperature not less than 5700 degree K (h) life not less than 50000 hours of operation
S&F in repair Bracket/Arm suitable for street light fittings, made out of 32 mm bore (light grade) GI pipe length not exceeding 1.5 metre long, fixed with 02 sets of flat iron clamp of size 25mm x 5 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed by the Engr-in-Charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized iron strip 25 X 4 mm (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
M A ENTERPRISES
Shanti Construction Company
MODERN AGENCY
KT CONSTRUCTIONS
M/S SRINIVASA CONSTRUCTION
DECORATIVE CONSTRUCTION
SRI BHOOMIJ INFRAPROJECTS & SERVICES LLP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .