Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC | L1 | Accepted-AOC Accepted due to lowest | |
| 2 | L2₹12.2 L+₹2.1 L (21.3%)Rejected-Finance | L2 | Rejected-Finance Rejected due to not lowest | |
| 3 | L3₹12.1 L+₹2.0 L (20.1%)Rejected-Finance 1946 KAMAL CINEMA STREET BATHINDA CITY BATHINDA PUNJAB | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Rejected due to not lowest |
Tender Value
₹1.0 L
EMD Value
₹20,800
Closing Date
10 Jun 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Nishant Shukla GE
GE I P No 1 Bathinda Mil Stn
PROVN OF ARBORICULTURE FOR KLP ACCN FOR 572 SUB GP ASCON AT BATHINDA MIL STN
2020_MES_345162_1
GE (I) (P) No 1 BTD-01/2020-21
Open Tender
Civil Works
Item Rate
180 days
Bathinda Mil Stn
As per NIT
7 documents required · 7 mandatory
₹500
GE (I) (P) No. 1 Bathinda Mil Stn
₹20,800
Yes
26 Jun 2020
15 May 2020
12 Jun 2020
15 May 2020
10 Jun 2020
27 May 2020
18 May 2020 - 22 May 2020
60 days
Amount
Surface dressing not exceeding 15cm deep in soft / loose soil complete all as specified and directed by Engineer-in-Charge.
Excavation over areas, not exceeding 1.5m deep and getting out of soft / loose soil complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick plain cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in flooring finished even and smooth using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic coloured tiles 300mm x 200mm x 7mm / 400mm x 200mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-charge.
M&L for non skid ceramic joint free coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) including necessary cutting as per site requirement complete all as specified and directed by Engineer-in-charge.
M&L for expanded metal weight n. exc 4 Kg per sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples to wood or steel members complete all as specified and directed by Engineer-in-charge.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
M&L for use and waste of form work to sides of pillars, columns and base for fountain flower (Ornamental) etc. for rough finished, circular surfaces of concrete complete all as specified and directed by Engineer-in-charge.
M&L for use and waste of form work to soffits of suspended slab such as roof slab, fountain flower (Ornamental) and similar work not exceeding 200mm thick (horizontal or sloping), rough finished, curved surface of concrete complete all as specified and directed by Engineer-in-charge.
M&L for reinforced cement concrete (1:2:4) type B-1, nominal mix using 20mm graded stone aggregate as in columns, pillars and base for fountain flower (Ornamental) complete all as specified and directed by Engineer-in-charge.
M&L for reinforced cement concrete (1:2:4) type B-1, nominal mix using 20mm graded stone aggregate as in slabs supported on walls, beams, roofs, canopies and fountain flower (Ornamental) and the like complete all as specified and directed by Engineer-in-charge.
S&F mild steel TMT bars 6 to 8 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:6) on fair face surface of brick masonary or concrete surface of walls, or on other than fair face, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surface of wall / concrete or ceiling of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over & including one coat of priming paints plaster coat complete all as specified and directed by Engineer-in-charge.
Supplying & planting of following trees in 0.25-0.30m girth in poly bags with height 0.90-1.20m stacking with bomboo sticks in pit of size1.20m dia & 1.20m deep in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio 2:1 (2 parts of stacked volume of earth reduced by 20% with a part of stacked volume of sludge or manure after reduction by 8%) flooding with water and removal of extra soil by spreading and neatly levelling complete all as specified and directed by Engineer-in-charge.
Ashoka Regional
Kinnow
Shisham
Amrapali Mango
Jammun
Guava
Fish Palm
Bottle Palm
Amaltas
Gulmohar
Kesia
Kaner
Chandhani
Latania
Golden Sapersh
Cycus Palm
Phostal Palm
Supplying & planting / laying of lawn with (Doob / mexican / english) grass in rows 5cm apart in either direction including preparation of lawn area by excavating upto 30cm depth, getting out, returning, filling in / spreading the same with the excavated earth (after breaking of clods & removal of rubbish / stone etc.) mixed with sludge or manure in the ratio 1:8 (8 parts of stacked volume of earth after reducing 20% with a part of stacked volume of sludge or manure after reduction by 8%) flooding with water and finally fine dressing, levelling etc. including disposal of extra earth or material declared unserviciable by spreading and levelling within a lead of 50m and lift upto 1m complete all as specified and directed by Engineer-in-charge. Note : Contractor shall maintain the grass till physical completion of contract. Unit rate quoted is inclusive of replacement of dead grass and manure required, nothing extra shall be paid on this account.
Supplying & planting of hedge shrubbery including creation of beds by excavating 60cm deep and 60cm wide trenching the excavated base to a further depth of 30cm wide, re-filling the excavation earth after breaking clods and mixing with manure or sludge in the ratio 1:8 (8 parts of stacked volume of earth after reducing 20% with one part of stacked volume of sludge or manure after reduction by 8%) flooding with water filling with earth if necessary, and finally fine dressing, levelling etc. including stacking and disposal of material declared unserviciable and surplus earth by spreading and levelling within a lead of 50m and lift upto 1.0m complete all as specified and directed by Engineer-in-charge. Note: Distance between two hedge plants shall not be more than 15cm.
S&F 20mm bore galvanized steel water tubing medium grade with & including all fittings such as tees, sockets, bends, elbows, union etc., laid in trenches complete all as specified and directed by Engineer-in-charge. Note : Excavation and earth work shall be measured and paid for separately under respective items of BOQ.
As per item No 21 above but 25mm dia bore.
As per item No 21 above but 40mm dia bore.
As per item No 21 above but 50mm dia bore.
S&F 20mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
As per item No 25 above but 40mm dia bore.
As per item No 25 above but 50mm dia bore.
M&L for construction of brick masonry valve pit of internal size 45cm x 45cm x 45cm including necessary excavation and earth work in soft / loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 25mm x 25mm x 5mm, MS sheet cover of 3mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50mm dia brass pad lock, complete all as specified and directed by Engineer-in-charge. Note : (i) Brick wall shall be 23cm thick built in cement mortar (1:4). (ii) Internal plaster shall be 15mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:4) as the work proceeds. (iii) PCC in foundation shall be 15cm thick in cement concrete (1:3:6) type C2 using 40mm graded stone aggregate extended 15cm all around from the external face of the walls. (iv) PCC coping shall be 15cm thick in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Three coats of white wash to internal surface of valve pit. (vi) Depth of valve pit shall be rackoned from the top of PCC in foundation.
M&L for cutting existing CI / DI pipe upto 150mm bore and reducing to required length before laying in position for insertion of new 20mm dia tee, collar, branches etc, complete all as specified and directed by Engineer-in-charge. Note : Cost of DI / GI fittings required is included in the unit rate of this item. Nothing extra shall be paid on this account.
Excavation in trenches, not exc 1.5m wide and n. exc 1.5m depth, or n. exc 10Sqm on plan and n. exc 1.5m in depth for foundations of poles, struts, stays, laying underground cable and laying water supply pipe line etc. in soft / loose soil & getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling watering and well ramming in layers n. exc 25cm in soft / loose soil complete all as specified and directed by Engineer-in-charge.
M&L for clean dry river sand for cushioning to underground cable, 8cm before laying and 15cm after laying and punned to 18cm after laying of cable in trenches complete all as specified and directed by Engineer-in-charge. Note : For payment purpose thickness after punning shall be measured.
M&L for brick protection with old size sub class 'B' bricks laid flat, abutting each other with gap between adjacent bricks not exc 10mm, length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-charge.
S&F Galvanized iron tubing, 40mm dia bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25 x 3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and directed by Engineer-in-charge. Note : Excavation & earthwork shall be measured & paid for separately under respective items of BOQ.
S&F 32mm bore galvanized steel water tubing medium grade bent in circular shape suaitable for fountain of 3metre dia having continuous adjustable brass ending nozzles at 20cm interval complete all as specified and directed by Engineer-in-charge.
S&F 9 Watt LED wall mounted round under water fountain light with IP-68 protection with aluminum alloy dia cast shell stainless steel front cover and 4mm tempered glass cover durable enough to withstand under water application having beam angle upto 120 degree including water tight connection with suitable twin core copper wire of size 1.00Sqmm complete all as specified and directed by Engineer-in-Charge.
S&F 1.5 HP, single phase 220 volt, power rating 1.1KW open well submersible pump set copper wound suitable for fountain with minimum 15metre head including all connections and fixing arrangement in air tight , water proof, dust proof with IP-65 protection complete all as specified and directed by Engineer-in-Charge.
S&F multistranded copper conductor cable 2.5Sqmm, 3 core , 1100 volts grade PVC insulated and PVC sheathed suitable for submersible pump compete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing, commissioning and testing, XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 10 sqmm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches along poles through pipes etc complete all as specified and directed by Engineer-in-Charge. Notes :- (i) Sand cushioning, cable protection, GI pipe and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting / cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Supply, install, test and commissioning LT panel duly powder coated of suitable size outdoor cubical type factory made, weather & vermin proof made out of CRCA sheet 3.15mm (outdoor type) thick machine pressed CPRI approved with bottom frame made out of angle iron 50mmx50mmx6mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cmx30cmx60cm and 100mm thick PCC (1:2:4) type B1 floor over 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body complete and suitable for 230 Volt AC single phase, 2 strip insulated with PVC sleeve aluminum bus bar 50 Amps SPN from pole with openable double shutter on both sides (rear and front side) with locking arrangement duly pre-wired with suitable size of copper conductor cable fitted with proper size copper lugs/thimbless and connecting the incoming and outgoing MCB with suitable size copper strip duly bended and drilled and fixed with nuts, bolts & washers from bus bar to MCB etc duly fitted with and including the following accessories complete all as specified and directed by Engineer-in-Charge. (a) DOL starter suitable for 1.5 HP Single Phase submersible motor pump. Make : Havell's / L&T / C&S / Legrend (b) MCB SPN 16 Amp, ‘C’ curve. (C) MCB SPN 6 Amp, ‘C’ curve.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanized iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanized iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete(1:2:4) type B-1 and 40m thick RCC cover, excavation & earth work complete all as shown in electrical plate No.3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engineer-in-Charge. Notes :- (i) GI wire upto DBs or upto earth test points is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away; from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for RCC cover shall be 1 KG.
PHASE-II (MAINTENANCE) Complete maintenance of 346 trees, 550Sqm grass and 660 RM hedge by weeding, watering, saucer making once in every week for paints/ hedge and healing, upkeep, watering, cutting grass & removing unwanted grass once in every 10 days, insect pest management (as and when required) pruning dried branches once in a week, depositing the materials at place as directed by Engineer-in-Charge, planting new plants in place of dead plants of same species and height, tuning with dods wherever required by replacing the dead patches of grass with same grass as required without any extra cost to the department and enrichment with manure @ 0.003 Cu.m per pit, 7mm thick average layer in grass & @0.004 cum per RM of hedge or as directed by Engineer-in-Charge. Note :- (i) Manure & pesticide required for maintenance of plants under this item shall be arranged by the contractor at his own cost and rates of the same shall be deemed to be included in the unit rate quoted. Nothing extra shall be paid on this account. (ii) Work against this item will be commenced only after completion of item No 18,19 & 20 here-in-before. (iii) Minimum one skilled gardener for full time shall be employed against this item.
RINKU BROTHERS
M/s Kataria Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .