| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.4 LAccepted-AOC B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | ₹22.4 L Quoted ₹22.9 L | L1 | Accepted-AOC Lowest and Reasonable |
| 2 | L2₹26.4 L+₹3.5 L (15.0%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹26.4 L+₹3.5 L (15.0%) | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹26.5 L+₹3.5 L (15.3%)Rejected-Finance | ₹26.5 L+₹3.5 L (15.3%) | L3 | Rejected-Finance Other than Lowest |
| 4 | L4₹27.4 L+₹4.4 L (19.2%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | ₹27.4 L+₹4.4 L (19.2%) | L4 | Rejected-Finance Other than Lowest |
| 5 | L5₹27.4 L+₹4.4 L (19.3%)Rejected-Finance | ₹27.4 L+₹4.4 L (19.3%) | L5 | Rejected-Finance Other than Lowest |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
12 Jun 2023, 6:00 pmClosed
CWE (AF) Jammu
Headquarters, CWE (AF) Jammu Near Gurdwara Sahib and Mandir Airforce Station Satwari, Jammu Pin 180 003
COMPERHENSIVE MAINTENANCE OF LT/HT CONTROL PANEL, BATTERY BANK, ELECTRONIC EQUIPMENT, RELAY SETTING OF VCB ETC. ALONG WITH CERTAIN MISC WORK AT AF STN UDHAMPUR
2023_MES_595601_1
CWEAFJ-05/2023-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Udhampur
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE (AF) Udhampur
₹66,000
Yes
3 Aug 2023
15 May 2023
14 Jun 2023
15 May 2023
12 Jun 2023
29 May 2023
Amount
Maintenance and complete servicing of 11 KV VCB Make: Crompton / Kirloskar / Alstom or as existing. including disassembling of operating mechanism parts, well greasing of springs / repair of mechanical parts, spring charge assembly and reassembling of parts including well cleaning the complete panel board, main bus bar, de-carbonizing all joints bus bar, CTs, PTs, spouts metal parts and making VCB perfect operating in manual and electric mode including all routine and preventive maintenance complete and replacing unserviceable parts, rewiring the Control Circuit / LT Circuit and components etc. complete all as specified and directed.
Notes :- 1. The above job to be carried out by engineer of Authorised Dealer / Service Centre of concerned OEM. 2. Replacement of defective items shall be measured and paid separately as supply only. The labour charges for fixing of the same shall be deemed to be included in this item. 3. Minor items such as nuts, bolts / pins and control internal wiring are included in the quoted rate of this item and nothing extra from the department will be admissible on this account. 4. The contractor shall arrange for the standby supply for testing of relays etc.
5. Taking out relay set (02 Nos over current & 01 No earth fault relay) of any make from HT11 KV VCB / (SF-6 type) panel and cleaning the contact (NO + NC) by CTC solution and adjusting the contact and calibrate the relay by Relay Testing Kit and proper plug setting as per required load & time delay and fixing the relay set in HT panels complete shall be done all as specified and directed.
(a) Supply only in repair Closing Coil Indoor type for 11 KV VCB as per existing Make / Model / Capacity complete all as specified and directed.
(b) Supply only in repair Tripping Coil Indoor type for 11 KV VCB as per existing Make / Model / Capacity complete all as specified and directed.
(c) Supply only in repair Spring Charging Motor suitable for fixing with 11 KV indoor type VCB panel as per existing Make / Model / Capacity complete all as specified and directed.
(d) Supply only in repair Insulator of VCB as per existing Make / Model / Capacity complete all as specified and directed.
(e) Supply only in repair Digital Volt Meter / Ammeter as per existing Make / Model / Capacity complete all as specified and directed.
(f) Supply only in repair Indicator Lamp as per existing Make / Model / Capacity complete all as specified and directed.
(g) Supply only in repair cast regin CT of ratio 400 / 200 / 5 / 5A as per existing Ratio / Make / Model / Capacity complete all as specified and directed.
(h) Supply only in repair cast regin wound PT as per existing Ratio / Make / Model / Capacity complete all as specified and directed.
(j) Supply only in repair Isolating Contact flat type as per existing Make / Model / Capacity and size complete all as specified and directed.
(k) Supply only TnC Switch (Tripping Neutral & Closing) as per existing Make / Model / Capacity and size complete all as specified and directed.
(l) Supply only in repair Power Pack units with maintenance free batteries in sheet metal enclosure as per existing Make / Model / Capacity and size complete all as specified and directed.
(m) Supply only in repair high voltage fuse as per existing Make / Model / Capacity and size complete all as specified and directed.
(n) Supply only in repair VCB panel spout as per existing Make / Model / Capacity and size complete all as specified and directed.
(o) Supply only in repair Trip Fork Linkage Assembly as per existing Make / Model / Capacity and size complete all as specified and directed.
(p) Supply only in repair Insulating Gear Charging Handle as per existing Make / Model / Capacity and size complete all as specified and directed.
(q) Supply only in repair Ratchet Wheel as per existing Make / Model / Capacity and size complete all as specified and directed.
(r) Supply only in repair Pin for Ratchet as per existing Make / Model / Capacity and size complete all as specified and directed.
(s) Supply only in repair Relay Assembly as per existing Make / Model / Capacity and size complete all as specified and directed.
(t) Supply only in repair Interlocking Mechanism as per existing Make / Model / Capacity and size complete all as specified and directed.
(u) Supply only in Repair of Relay of any type complete all as specified and directed.
Maintenance and servicing, tuning, calibration and testing of RMU / SF-6 Gas filled Circuit Breaker / Isolator / Remote Panel of make : Schneider Electric including checking of all electrical wiring, disassembling of operating mechanism parts, well cleaning, replacing unserviceable parts and accessories, oiling/greasing of moving parts including reassembling, proper setting of all mechanism, and making SF-6 Breaker in perfect operational in manual and electrical mode including well cleaning the complete Panel Board, main bus bar coupler, decarbonizing all joints, bus bars coupler, CTs, PTs, spouts metal parts and replacing unserviceable parts and components complete, all as specified and directed.
Notes : 1. The above job to be carried out by engineer of Authorised Dealer / Service Centre of concerned OEM. 2. Replacement of defective items shall be measured and paid separately as supply only. The labour charges for fixing of the same shall be deemed to be included in this item. 3. Contractor will submit the connected documents / Graph for Relay calibration duly authenticated by authorised dealer/service centre. 4. The contractor shall arrange for the standby supply for testing of relays etc. 5. Any set of LBS, Bus Coupler, SF-6 Breaker etc. in single RMU Unit shall be considered one item.
(a) Supply only repair RMU Protection Relay DPX-V5 as per existing Make / Model / Capacity and size complete all as specified and directed.
(b) Supply only in repair Spring Charging Motor (230 Volt AC) as per existing Make / Model / Capacity and size complete all as specified and directed.
(c) Supply only in repair Spout for Breaker as per existing Make / Model / Capacity and size complete all as specified and directed.
(d) Supply only in repair Digital Multifunction Meter as per existing Make / Model / Capacity and size complete all as specified and directed.
(e) Supply only in repair Interlocking Bush between A & K mechanism as per existing Make / Model / Capacity and size complete all as specified and directed.
(f) Supply only in repair Digital Indicator Lamp for breaker ON / OFF / Trip / Breaker Spring Charged / R-Y-B etc. in 11 KV HT Panel including associated wiring, if required complete all as per existing Make / Model / Capacity and size complete all as specified and directed.
(g) Supply only in repair cast regin wound CT as per existing Ratio / Make / Model / Capacity complete all as specified and directed.
(h) Supply only in repair only cast regin wound PT as per existing Ratio / Make / Model / Capacity complete all as specified and directed.
(j) Supply only in repair 2PA mechanism w/o Hex Rod as per existing Make / Model / Capacity complete all as specified and directed.
(k) Supply only in repair Linkage between K and A as per existing Make / Model / Capacity complete all as specified and directed.
(l) Supply only in repair 3 PKE Mechanism w/o Hex rod as per existing Make / Model / Capacity complete all as specified and directed.
(m) Supply only in repair Locking Arrangement Handle for RMU as per existing make/model
(n) Supply only in repair Terminal Protector Silcab for 11 KV as per existing Make / Model / Capacity complete all as specified and directed.
(o) Supply only in repair Voltage presence Indicator as per existing Make / Model / Capacity complete all as specified and directed.
(p) Supply only in repair Battery 12 VDC, 12 AH of relay as per existing Make / Model / Capacity complete all as specified and directed.
(q) Supply only O Ring 72 x 6 bushing 400 series bolted as per existing Make / Model / Capacity complete all as specified and directed.
Repair to HT VCB 33 KV Three Phase 800 Amps 250 MVA installed at Grid Main Power House after disconnecting the main supply incoming panel for repairs and replacement of unserviceable parts and refixing the same after repair and testing on full load (Cost of spare parts and other job works will be paid under respective items), complete all as specified and directed. Notes : 1. The Quoted Rates are deemed to include the cost of all tools, material and labour required for dismantling taking out and assembling of Breaker with replacement of worn out nuts and bolts, gaskets, A-grade greasing and oiling of moving parts and refixing the same.
2. Quoted Rates are deemed to include the cost of material and labour required to make alternative arrangement to by-pass the electric supply through the HT panel or other HT line to avoid long period of shut down of electric supply.
(a) Opening the SF-6 Breaker and replacing the single phase burnt motor from breaker with appropriate size of motor, complete all as specified and directed.
(b) Repair of Motor Charging Gear, complete all as specified and directed.
(c) Repair / Replacement of Lifting Lock in and out, complete all as specified and directed.
(d) Replacement of burnt Trip Coil Assembly 24 Volts DC, complete all as specified and directed.
(e) Replacement of burnt Closing Coil Assembly 24Volts DC, complete all as specified and directed.
Periodical / Routine Serving of Control Panel of 33/11 KV rating in such as checking of all wiring connection of differential relay and auxiliary relays and blowing out dust, calibration of relay & repair and replacement of defective components as per existing Make / Model / Capacity of 33/11 KV CR Panel including connecting the all electrical connection and testing complete all as specified and directed. Make : ABB CR Panel
Notes :- 1. The above job to be carried out by engineer of Authorised Dealer / Service Centre of concerned OEM. 2. Replacement of defective items shall be measured and paid separately as supply only. The labour charges for fixing of the same shall be deemed to be included in this item. 3. Contractor will submit the connected documents / Graph for Relay calibration duly authenticated by authorised dealer/service centre. 4. The contractor shall arrange for the standby supply for testing of relays etc.
(a) Fixing only in repairs Test terminal block as per existing Make / Model / Capacity all as specified and as directed.
(b) Fixing only in repairs DC Supervision Relay as per existing Make / Model / Capacity all as specified and as directed.
(c) Fixing only in repairs AC Supervision Relay as per existing Make / Model / Capacity all as specified and as directed.
(d) Fixing only in repairs Kit Kat Fuse as per existing Make / Model / Capacity all as specified and as directed.
(e) Fixing only in repairs Winding Temp Alarm Relay as per existing Make / Model / Capacity all as specified and as directed.
(f) Fixing only in repairs Supervision Relay for trip circuit as per existing Make / Model / Capacity all as specified and as directed.
(g) Fixing only in repairs Master trip relay as per existing Make / Model / Capacity all as specified and as directed.
(h) Fixing only in repairs Buch Trip / Buch Alarm Relay as per existing Make / Model / Capacity all as specified and as directed.
(j) Fixing only in repairs PRV Trip / PRV Alarm Relay as per existing Make / Model / Capacity all as specified and as directed.
Disconnecting and taking out the unserviceable battery from battery bank any capacity supply and fix new lead acid Maintenance Free Battery 2 Volts 10 AH including connecting of all batteries in Battery Bank and testing upto complete all as specified and as directed
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out in any type of soil for taking up or laying of cable complete all as specified and directed.
Excavating in trenches, not exceeding 1.5metre wide and exceeding 1.5metre depth but not exceeding 3.0metre depth for foundation, etc., and getting out in any type of soil, complete all as specified and directed.
Returning filling in soils including spreading, levelling, watering and well ramming in layers not exceeding 25csm thick complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed.
Supply and laying new dry sand or Dry coarse sand as cushioning to cable 8cm below the cable and 15cm above the cable and punned to 18cm as cable cushioning and covering complete all as specified and directed. Note : Punned quantity will be measured and paid at this item.
Un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40 mm including taking down old unserviceable cable cover complete all as specified and directed.
GI tubing light grade of size 80mm with all fittings laid in trenches or fixed to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads / PCC and making good after laying of cable complete all as specified and as directed.
Danger Notice Plate made of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters , figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT, 25mm x 20mm x 1.6 mm size complete all as specified and directed.
Supplying, laying, jointing, testing and commissioning in repair HT under ground electric power cable Crossed linked polyethylene (XLPE) insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts grade suitable for earth system of 3 Core 95 Sqmm cross sectional area size, ISI marked as per IS 7098 Part-2, laid in trenches / laid under floor / laid in ducts or fixed on poles etc. complete all as specified and directed.
PCC 1:3:6 type C-2 using 40mm graded aggregate as in foundation of broken VCB / RMU / Transformer Plinth with necessary formwork complete all as specified and directed.
PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping etc. for broken VCB / RMU / Transformer Plinth including necessary form work complete all as specified and directed.
Earthing complete as per electrical plate No 5 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0 mm, buried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to and including galvanised iron or steel earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing strip protected by galvanised iron or steel pipe 50 mm bore medium grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil, charcoal, salt, funnel , PCC pit and RCC cover complete all as specified and as directed.
M&L for tracing the HT/ UG cable fault with HT cable fault locator of 33 KV/11KV System in any situation / position complete as directed. Note :- One Single cable of any length from end to end termination with any number / type of faults will be considered to constitute only one quantity for tracing and payment purpose.
Cleaning the sub station in side & out side Building / Fencing of Transformer / Two / Four Structure and also including around 2m radius out side of fencing in every month duly taking down unwanted material / grass / vegetable roots / small tree / trimming of branches of tree inside and outside etc. complete all as specified and directed.
Rubber Matting chequered suitable upto 11 KV rating as per IS 15652-2006, (superseding IS 5424) of size 2mtrs x 1.0mtrs x 2.5mm thick all as specified.
Cable Jointing Kit for 11 KV (earthed) grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and as directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Outdoor Termination Heat Shrink type joint complete with jointing material and accessories suitable for 3 Core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and as directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Straight Through Heat Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and as directed.
Cable Jointing Kit for 11 KV (earthed) grade cable for Straight Through Heat Shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm complete all as specified and as directed.
Steel Tubular swaged poles type 410 SP-55 (11.0 mtr long) conforming to IS : 2713 Part-I to III 1980, complete with 6 mm thick mild steel base plate, finial taper plug, MS bolts, nuts, screws including painting upto 1.5metre above PCC coping in black and white strips 05 Nos of 30cms each starting from the bottom of the pole and two coats epoxy based paint aluminium grade finish to the remaining external surface over one coat of primer and writing Pole No complete including taking down old unserviceable Pole all as specified and as directed.
Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, drilling holes for bolts, in any shape or size as indicated or directed and also inclusive of two coats of aluminium paint over one coat of red oxide primer including dismantling / taking down old unserviceable structural steel all as specified and as directed.
Switch Air break, gang operated (GOD) with 15 Nos insulators in replacement, outdoor type, Tripple Pole mechanically operated, suitable for vertical installation, Single break, provided with locking arrangements consisting of MS channel, HT Post type insulator copper alloy, high Pressure, Assembly operating rod 25 mm dia GI pipe medium grade for operating from 1.2 metre above Ground Level with locking arrangement complete confirming to IS-1318 of 1972 rated voltage 11 KV and for current rating 200 Amps complete with dropout fuse assembly of rating 40 Amps, including taking down old unserviceable GOD all as specified and directed.
Lightening Arrestor expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps and high current withstand 100 KA outdoor type for 11000 volts, including clamps, nuts and bolts, washers and connecting earth wire 4 mm GI strip to Lightning arrester complete all as specified and directed.
11 KV HT Bus bar, Outdoor type, suitable for 11000 Volts, AC 3 Phase supply, 630 Amps, Unit fabricated out of 3.15 mm steel or MS steel enclosure suitable with MS Base Channel. The panel contains the equipments & components complete with copper bus bar interconnections, designation labels caution notices and pad locking facilities wherever required. The size of the bus bar not less than 1200mm x 1000mm x 800 mm to accommodate the incoming and outgoing cable connections with front and back hinged doors with proper locking arrangement, rubber gasket on front and back to make it dust and vermin proof, powder coated. The cubicle shall have frame work, bottom & 50 Cm long four legs of size 50 x 50 x 6 mm Angle iron. The panel shall be mounted on floor with PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate)
foundation block of suitable size upto 40cm above the ground and 60cm below the ground level. The panels shall be finished with powder coated paint - Siemens Grey Ral 7032. The Panels shall be fitted with the following accessories :- (a) Copper Bus Bar 50 x 12 mm, suitable rating, TP, Air insulated with colour coded RYB Heat shrinkable sleeves (b) Earth bus 40 x 6 mm copper bus bar. (c) Danger Notice Board Note : The Quoted Rate shall be deemed to include the cost of the PCC foundation.
Flood Light 250 watt LED, IP-66, 110 Lm/W energy saving, environmental friendly long life exclusive innovative die cast aluminium, flood light with high power LED as light source suitable for highlighting architectural feature or area lighting also suitable for installation in grid alongwith clamp etc. for fixing arrangement including taking down old unserviceable Street Light complete as specified and directed.
DAVINDER SINGH
shivom builders
slathia construction works
PROACH ASSOCIATES BUILDERS & ENGINEERS
Bidder Name
slathia construction works
ANIKET TRADERS
DAVINDER SINGH
shivom builders
PROACH ASSOCIATES BUILDERS & ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .