Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
3 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE (AF) BKT
GE (AF) BKT Lucknow
REPAIR / MAINT OF SUMMER APPLIANCES, FAN AND OTHER CONNECTED WORKS AND ESSENTIAL REPAIR TO EARTHING INFRASTRUCTURE AND LIGHTING PROTECTION AT AF STN BKT
2026_MES_793676_1
8927/BKT/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) BKT
₹50,000
13 Oct 2026
13 Oct 2026
6 Nov 2026
13 Oct 2026
3 Nov 2026
27 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Servicing, and cleaning of tower air conditioner of capacity 1.5/ 2.0 Ton capacity at site, cleaning of equipment by applying blower, water pressure Jet machine to remove the complete dust, cleaning of drain line to resolve the issue of leakage all the components with suitable cleaning agent, combing the condenser coil for better efficiancy complete all as specified and directed. | 2 | Each Job | - | - |
| 2 | Servicing, and cleaning of flame proof air conditioner of capaciting 1.5/2.0 Ton capacity at site, cleaning of equipment by applying blower, water pressure Jet machine to remove the complete dust, cleaning of drain line to resolve the issue of leakage all the components with suitable cleaning agent, combing the condenser coil for better efficiancy complete all as specified and directed. | 6 | Each Job | - | - |
| 3 | Servicing, and cleaning of Fan coil type air conditioner of capacity 1.5/2.0 Ton capacity at site, cleaning of equipment by applying blower, water pressure Jet machine to remove the complete dust, cleaning of drain line to resolve the issue of leakage all the components with suitable cleaning agent, combing the condenser coil for better efficiancy complete all as specified and directed. | 3 | Each Job | - | - |
| 4 | Servicing, cleaning and of window /split air conditioner (indoor and outdoor unit complete of capacity 1.5/2.0/3.0 Ton capacity at site, cleaning of equipment by applying blower, water pressure Jet machine, Water jacket for indoor to remove the complete dust, cleaning of drain line to resolve the issue of water leakage all the components with suitable cleaning agent, combing the condenser coil for better efficiancy complete all as specified and directed.
Note :- Sevicing and cleaning may required more than once in same appliences in period of contract.Payment will be made accordingly. | 150 | Each Job | - | - |
| 5 | Repair/ maintenance of window /split type air conditioner of capacity 1.5/2.0/3.0 Ton capacity at site,checking the wiring, starting/running capacitor, staring relay, overload relay, thermostat switches condensor motor,blower motor,swing motor ,blower/condensor fan/ removal of defactive parts and rectification of fault,Top Up/charging of gas at required pressure for proper cooling, connecting and testing on load. complete all as specified and directed.
NOTE;- (i) Defective parts/Gas (refrigerant) shall be measured and paid seperately as 'Supply Only' under respective item of Sch "A"
(ii) Complaints have to attend on day to day basis and regular visit of adequate mechanic during contract period to maintain above Nos appliances at the Stn in tech and as well as Adam area.
(iii) Payment for each job shall be made once only during currency of contract irrespective of attending / replacing defective parts at any time that will be paid supply only under respective item if not paid earlier.
(iv) complaint for non function of ACs have to attend on same day and normal defects have to rectify within 24 hours ,major defects have to rectified within 4 days otherwise recovery shall be made @ 500/ day of delay.
(v) If required and repair is beyond at site taking out & refixing of AC unit any repair shall be deemed to be include in quoted rate. | 25 | Each Job | - | - |
| 6 | M&L for detecting leakage of refrigerant gas from Split/ Window AC by leakage test with provision of all T&P items as required at site and charging the refrigerant gas (R-22/ 32/ 134(a)/ 410C) as required,making good leakage portion by brazing complete all as specified and directed.
Note : The cost of Refrigerant is deemed to be included in quated unit rate of this item. | 15 | Each Job | - | - |
| 7 | Supply only R-22/R-32/R- 410 or required refrigerant in the Air conditioner to be repaired in Sch-A item No.2 of testing to the cooling appliances complete all as specified and directed. | 18 | Kg | - | - |
| 8 | Supply only condenser/Cooling fan motor along with fan blade suitable for window type AC of existing make complete all as specified and directed. | 3 | Each | - | - |
| 9 | supply only New Remote and PCB sensor unit assembly suitable for existing make of window type air conditioners non inverter model of capacity upto 2.0 TR complete all as specified and directed. | 3 | Each | - | - |
| 10 | supply only New Remote and PCB sensor unit assembly suitable for existing make of window type air conditioners inverter model of capacity upto 2.0 TR complete all as specified and directed. | 3 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
8927Tenderdoc.pdf
Tender Documents • 1.24 MB
8927Scredit.pdf
Additional Documents • 0.19 MB
BOQ_890090.xls
BOQ • 0.74 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .