SE, EDC-II, Jaunpur
office of The SE, EDC-II, Jaunpur
Capacity enchancement of a 33 11 KV Power Substation in Pilkichha Shahganj Jaunpur by upgrading the Transformer from 05 MVA to 10 MVA
2026_PVVNV_1130289_1
52/EDC-II(J)/2025-26
Open Tender
Electrical Works
Lump-sum
90 days
SE, EDC-II
Please refer Tender Documents
2 documents required · 2 mandatory
₹1,180
SE, EDC-II, Jaunpur
₹3,000
29 May 2026
25 Mar 2026
30 Apr 2026
25 Mar 2026
29 Apr 2026
25 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Alluminium lug 300 sqmm | 6 | No | - | - |
| 2 | 11 kV 3*300 sqmm XLPE cable jointing kit outdoor type | 1 | No | - | - |
| 3 | 11 kV 3*300 sqmm XLPE cable jointing kit indoor type | 1 | No | - | - |
| 4 | Painting of all structures by red oxide & allumiunium paint (All required materials like red oxide, alluminium paints will be provided by contractor) | 1 | Job | - | - |
| 5 | Clamp & Connector for switchyard equipment | 1 | Job | - | - |
| 6 | Earthing of S/s for indoor equipments
Laying of Earth mate for earthing of indoor equipments by means of M.S strip 50x6mm connecting to Pipe type earthing as per RESPO norms. Joints will be welded with high quality are welding. (All required materials will be provided by contractor) | 0.5 | Job | - | - |
| 7 | INSTALLATION OF 11kV SWITCHGEARS & CONTROL PANEL IN CONTROLROOM
A) Shifting carefully & safely 11kV O/G switchgear from outside of the switchgear room as per direction of Engineer in charge, placing and fixing of switchgear on foundation providing G.I. Nuts & Bolts of proper size in proper position and alignment and checking, complete work. (All required materials will be provided by contractor)
B) Fixing and making bus bar connections in between all switchgears after cleaning and tapping with H.T. Tape, empire tape and PVC tape properly and plugging of all opening & holes with plastic compound complete work including cost of all material (All required materials will be provided by contractor)
(C) Shifting carefully & installation of 33 kV single circuit transformer control panel in control room | 1 | Job | - | - |
| 8 | FABRICATION OF TRANSFORMER SEPARATE EARTHING T/F NEUTRAL EARTHING
(A) Seprate earthing of power T/F by way of boring and lowering "B" class GI pipe 2'' dia, - 2no*30 mtr deep (01 no for T/F body earthing and 01 no for T/F neutral in delta connection earthing and making earthing pit for each) by providing all materials like "B" class GI pipe 2'' dia, 50*6mm GI strip, socket, sand, charcoal, bricks, cement etc.(All required materials will be provided by contractor)
(B) Fabrication and grouting of M.S Channel 100*50*6mm in L- shape & in proper size and alignment to provide support for the two separate earthing strips 50*6mm size for power transformer neutral including supply and fixing of two nos. Flexible copper bonds for neutral earthing.(All required materials will be provided by contractor) | 1 | Job | - | - |
| 9 | Dismentaling of 8MVA Power T/F by disconnection of radiator, conservetor & other equipment along with removal of T/F oil shifting of T/F from inside to outside of switchyard as per RESPO norms | 1 | Job | - | - |
| 10 | Renovation of existing plinth of power T/F as per RESPO | 1 | Job | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
T52TD.pdf
Tender Documents • 1.02 MB
BOQ_2108548.xls
BOQ • 0.26 MB
T52DE2.pdf
PDF • 0.47 MB
T52DE1.pdf
PDF • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .