Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.5 L+₹2.5 L (11.8%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹24.1 L+₹3.1 L (14.8%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not eligibel category |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
21 Dec 2020, 6:00 pmClosed
GE (I) Campbell Bay
Garrison Engineer (I), Military Engineer Services, Army Land, Great Nicobar Islands, Campbell Bay, Pin 744 302
REPAIRS REPACE OF INTER WIRING AND FIXTURES AND REPLACE OF NORMAL LIGHT FITTINGS TO LED LIGHT FITTINGS MAINT AND REPLACE OF STREET LIGHTS INCLUDING OTHER FITTINGS FIXTURES AC REFRIGERATORS WATER COOLERS BASED ON DAY TO DAY COMPLAINTS AT INS KA
2020_MES_380956_5
8701/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (I) Campbell Bay, Kamorta
As per tender documents
9 documents required · 9 mandatory
₹500
Yes
GE (I) Campbell Bay
₹45,000
Yes
26 Feb 2021
3 Dec 2020
23 Dec 2020
4 Dec 2020
21 Dec 2020
4 Dec 2020
Amount
Taking down old unserviceable point wiring, (light, fan, socket or power) complete including fittings & fixtures such as switch, ceiling rose, pendants, regulator, socket, etc., and making good the disturbed surface of wall, floors, ceiling etc to match with the existing including touch up of paint/white wash all as specified and directed by Engineer- in-charge.
M & L for Point wiring with 1.5 Sq mm single core copper conductor FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid FRLS PVC rigid conduit and its accessories of suitable size, heavy grade ISI marked concealed on walls /roof and MS pressed steel terminal boxes of 1.6 mm thick of suitable size duly painted with red oxide metal primer including fixing/grouting sunken/ surface and making the adjacent surfaces smooth through POP work & painting as per site requirement incl provision of modular cover plates for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm multistranded copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for : (a) One light point controlled by one, one way switch 5 Amps
(b) One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
(c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
(e) One bell point controlled by one, bell switch 5 Amps
(f) One light point controlled by one, two way switch 5 Amps
Description all as per item No 2 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 1.5 sq mm multistranded copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
M & L for Point wiring with 1.5 Sq mm copper conductor multistranded FRLS PVC insulated unsheathed 1100 Volts multistranded drawn through and including rigid PVC caping and casing surface type and accessories of suitable size ISI marked and terminal boxes of 1.6 mm thick of suitable size including fixing/grouting sunken/ surface as per site requirement incl provision of modular cover plates for mounting the switches / sockets/ regulators etc including running up of 1.5 Sq mm multistranded copper conductor flame retardant PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for : (a) One light point controlled by one, one way switch 5 Amps
(b) One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
(e) One bell point controlled by one, one way bell switch 5 Amps
(f) One light point controlled by one, two way switch 5 Amps
Description all as per item No 9 here in before but using 2.5 sq mm single core copper conductor cable of multistranded FRLS PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 1.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly all as specified and directed .
S&F in repairs Modular switch one way 6 A, 1 module
S&F in repairs Modular switch one way 16 A, 1 module, with neon indicator
S&F in repairs Modular socket, 6A - 2/3 pin combined 2 module
S&F in repairs Modular socket, 6A/16A - 2/3 pin combined 2 module
S&F in repairs Modular switch 2 way 6 Amp, 1 module
S&F in repairs Modular Bell push 6 Amp, 1 module
S & F ceiling fan regulator step type, modular type heavy duty suitable to work on 230 volts Ac supply complete all as specified.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified.
Supply & Fix Lamp holder PVC/ Polycarbonate type with back plate suitable for batten fittings all as specified and directed .
S&F in repairs Bell, Ding Dong AC 230 volts, single pole all as specified and directed .
Material and labour for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2 x 4.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 4.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire complete as directed by Engr in Charge
Material and labour for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 2 x 6.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire completeas directed by Engr in Charge .
Material and labour for submain wiring with single core PVC insulated FRLS multistranded copper conductor cable of size 3 x 6.0 Sqmm drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories and 6.0 Sqmm FRLS multistranded copper conductor cable as continuous earth wire incl taking out old wire completeas directed by Engr in Charge .
M&L for SPN enclosure with two pin and earth plug and socket with 240 volts 20 Amp SPN MCB including removal old unsv one complete all as specified .
S & F in replacement sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incomming & outgoing MCBs and making smooth the wall surfaces complete all as specified.
S & F in replacement sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including refixing / fixing of incomming & outgoing MCBs and making smooth the wall surfaces complete all as specified.
S & F in replacement sheet metal enclosure verticle MCB DB TPN 4 way with 200 amps rated bus bar 415 volts double door with magnetic locking system including refixing / fixing of incomming & outgoing MCBs and making smooth the wall surfaces complete all as specified Note:- (i) New MCBs if required for replacement shall be measured and paid seperately under appropriate item as ''Supply only'' (s) of this schedule. However labour element involved in replacement is included in unit rate quoted against this Item. (ii) Rates for refixing old serviceable MCBs are deemed to be inclusive in above quoted rates.
Supply only MCBs of following rating (a) MCB SP 6 to 32 Amps 240V 10 KA. "C" Series
(b) MCB DP 32 Amps 240V 10 KA. "C" Series
(c) MCB TP 32 Amps 415V 10 KA. "C" Series
(d) MCB TPN 63 Amps 415V 16 KA. "C" Series Note:- MCBs / MCCBs will have to suite upon with the base of the existing Panel / DB as per site requirement
S & F in repairs switch piano single pole flush type 5 amps, 230 volts including removal old existing unsv one complete all as specified and directed.
S & F in repairs socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1, 230 Volts all as specified including removal old existing unsv one complete all as specified and directed.
S & F in repairs switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1 230 Volts all as specified including removal old existing unsv one complete all as specified and directed.
S & F in repairs switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 amps flush type including removal old existing unsv one complete all as specified and directed.
S & F wall mounted LED 18/20 watts with out put of 1800 lumens , box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 18 watts including removal old existing unsv tube light fitting complete all as specified and as directed. Make :- Bajaj, Philips, Wipro, Havells, Syska, Jaguar
S & F Ultra bright LED Tubelight 18/20 with out put of 1800 lumens (single side connection) with very high efficacy suitable for installation in existing tubelight G13 lamp holders to give glare free light with necessary wiring and removal old existing unsv tube from fitting complete all as specified and as directed. Make :- Bajaj Philips, Wipro, Havells, Syska, Jaguar
S & F Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb and removal old existing unsv tube light fitting complete all as specified and as directed. Make :- Bajaj, Philips, Wipro, Havells, Syska, Jaguar
S & F Surface mounting 10 Watt LED Luminaries with epoxy white powder coated CRCA sheet steel housing with reeded translucent acrylic diffuser and 1 x 10 Watt LED fitting including taking down old unserviceable fittings any type complete all as specified and as directed . Make : Phillips , Bajaj, Wipro
Supply only LED bulbs for lamp holders 10W complete all as specified & directed. Make :- Bajaj, Philips, Wipro, Havells, Syska
Dismantling and Taking out old unserviceable post lamp fittings and S&F integral 40 Watt LED post top lanterns with black ABS plastic spigot spun aluminium canopy,with opal acrylic difuser and accessories integral,Fedora hat post top lantern with clear acrylic complete all as directed. Make :- Bajaj, Philips, Wipro, Havells, Syska
Taking out the existing any type fittings on ceilings and S & F 36 Watt LED Luminaire suitable for 600x600mm modular ceiling grid including frame of suitable size of above LED light with high efficiency PMMA diffuser gives soft glare free light with available lumen output from 3600 total lumen.The 36 W system shall be operating at 220-240v AC supply having internal driver .IP20,surge protection 2KV ,ambient temperature -20 to 45 degree C, frequency 50 to 60 Hz ,The system efficacy must be between80-100 lumen /watt ,with 70% lumen maintenance upto 50000 Br Hrs with uniform visually comfortable light output at 150 degree beam spread , CRI minimum 80. PF should be greater than 0.95 , THD < 10% . Indivisual LED's should not be visible for glare free output ,colour temperature 6500k all as directed. Make :- Bajaj, Philips, Wipro, Havells, Syska, Jaguar
Taking down the ceiling / Exhaust fans of any model, size & sweep carefully from its original position and dismantling motor and over hauling complete by cleaning all dust / grease with kerosene or petrol, & replacement of unserviceable bearings, bushes, split pins and nut and bolts and applying new grease for bearings, reassembling the motor and fixing the blades, preparation old surfaces of fan of any sweep & model and painting the with synthetic enamelled paint by spraying including filling cavities and testing and refixing the same complete as directed by Engr in Charge, Note for Item (i). Any Parts required for replacement shall be measured and paid seperately under appropriate item as ''Supply only'' (s) of this schedule. However labour element involved in replacement is included in unit rate quoted against this Item. (ii). Any unforeseen minor repair and minor parts like Rubber bush, MS Clamps, split pins, base frames, nuts, bolts etc that are not covered under Item No-2, (a) to (e) but required to complete the repair work / smooth functioning of Fan Motor shall be deemed to be included with the unit rate .Transportation of Stator / Rotor parts for machining & rewinding, shaft / bushing for machining , welding , turning at lathe shop at Port Blair are also deemed to be included with unit rate. iii). Rewinding of stator / rotor of motor, any machine work where involved shall be measured and paid separetely against relevant item of this schedule.
Supply only following spares of ceiling / exhaust fan of any model, size & sweep to incorporate against each Item of Schedule 'A' here-in-above complete all as specifed & directed (a) Supply only ball bearing suitable for ceiling fan upto 1400 mm sweep
(b) Supply only ball bearing suitable for Exhuast fan upto 450 mm sweep
(c) Supply only GM bush for C/fan and E/fan
(d) M&L for rewinding the motor of ceiling Fan 1200mm/1400mm Sweep by unscrewing without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size & Capacity including,varnishing,drying etc,and refixing the stator and rotor perfectly to rotate smoothly and connection alongwith fixing of 2.5 MFD fan capacitor complete including taking out burned unserviceable copper winding wire all as directed.
(e) M&L for rewinding the motor of Exhaust Fan 300 / 450 mm Sweep by unscrewing without damaging any parts, rewinding the same with fine quality of super enamelled copper winding wire of suitable size & Capacity including,varnishing,drying etc,and refixing the stator and rotor perfectly to rotate smoothly and connection alongwith fixing of suitable fan capacitor complete including taking out burned unserviceable copper winding wire all as directed. Note for item (d) & (e):- Rates for incorporation of new fan capacitor of suitable capacities for smooth runinng of fans are deemed to be inclusive in the quoted rates
Supply and Fix in repairs capacitor 2.5 MFD capacity including removal of unserviceable ones complete all as specified and directed
Supply and Fix in repairs capacitor 4 MFD capacity including removal of unserviceable ones complete all as specified and directed
Taking down electric water heater (geyser) of any capacity from existing system, disconnected inlet and outlet water connection for leakage complaint and repair to water inner tank by means of brazing/welding etc. to arrest the leak and refixing the inner tank in outer shell with proper filling of glass wool as heat resistance material, suitable quantity,and refixing the geyser at it's original location complete all as directed
Supply & fix in repairs indicators of Geysers upto 50 ltrs. Capacity of any make, model & type complete all as specified and directed
Supply & fix in repairs safety valve plug made out brass metal with fusible lead, inner thread type suitable for existing geyser of any type, capacity & model complete all as directed.
Supply & fix in repairs heating element for following rating as required at site including rubber washers (ISI marked), Trangular/round shape, with pocket for thermostat (a) 1.5 KW
Supply & fix in repairs thermostat ISI marked suitable for the Geysers 25 ltrs. to 50 ltrs capacity,20 Amps, 240 Volts AC, adjustable type,210 mm long or nearest size as per sample complete all as directed
M & L for Taking out & Servicing Split type air conditioner in citu (Split type air conditioner comprises wiith out door and indoor unit complete) of capacity 1.5/ 2.0 TR of any make and any type by replacing unserviceable parts from the machine including charging of Refrigerant gas after vacuuming and leak testing. Brazing the suction/ discharge tubes where required and cleaning of cooling coil and condenser coil, oiling, greasing of blower motor, checking of electrical circuit and replacement of defective electric blower fan motor,over load protector,relay, capacitor etc to achive proper cooling effect and also checking of electronic circuit of machine and repair where necessory by replacing electronic parts and changing of wirings with proper size PVC insulated wires as directed and testing commissioning & refixing in same or new location complete all as specified and directed. Note:- i) Compressor where ever is required shall be measured and paid separately under respective item. ii) During vacuming the machine existing Refrigerant shall be collected in cylinder and the same shall be reused while charging after carry out of repair and additional qty required for smooth functioning shall be measured and paid separately under respective item. iii) Spares parts where ever is required shall be measured and paid separately under respective item of schedule A. iv) Unit rate is deem to be included for minor parts such as capilary tube, machine screw, washer, rubber bush etc required for proper setting of machine. (v) Unit rate is deem to be included for necessary opening in window / wall of any type and thickness, cutting of grill any type / size fixing of AC & necessary plywood, commerical type, 6 mm thick of suitable size as packing material to cover the hole/ window (vi) Transportation for shifting of AC's will be provided by contractor and rate for same is deemed to be included in quoted rate.
Supply only electric blower fan motor of split AC 230 volt 1340 RPM single shaft with ball bearing for any make split AC 1.5 Ton capacity complete all as specified and directed.
Supply only overload protector for split type AC of capacity 1.5 ton carrier make complete all as specified and directed.
Supply only running capacitor 45 MFD and complete all as specified and directed.
Supply only starting capacitor 100/120 MFD complete and complete all as specified and directed.
Supply only outdoor unit fan motor 1/20 HP 230 Volt Split AC of capacity 1.5 ton complete all as specified and directed.
Supply only out door unit fan blade heavy duty of existing make Split AC of capacity 1.5 ton/ 2.0 ton as per existing complete all as specified and directed.
S & F for copper tubing of following sizes for suction / discharge line of any make split AC of capacity 1.5 ton with rubber insulation of pipe tube type insulation including removal of old existing unsv one complete all as specified and directed. (a) 3/8" size
(b) 5/8” size
(c) 1/4" size
(d) 1/2" size
Supply only for high wall blower fixed on indoor unit of make as per existing split AC 1.5 ton capacity including removal of old existing unsv one complete all as specified and directed.
S & F for indoor unit split type air conditioner 1.5 ton capacity wall mounted operation on 230 volts + 10% 50 HZ single phase performing on cooling, dehumidifying, cord less, remote and digital temp display system of make as per existing including removal of old existing unsv one complete all as specified and directed.
Taking down existing unserviceable outdoor unit and supply and fix new outdoor unit for 1.5 TR capacity Split AC working with non CFC refrgerent gas with blower motor fan, cooling coil all pre-wired but with compressor of make as per existing complete all as specified and directed.
S & F for flexible PVC/hose pipe 20 mm dia heavy duty from outdoor unit including removal of old existing unsv one complete all as specified and directed.
Material & labour for filling up & charging of R - 22 refrigerant or type of gas as per site requirement for window/spilt type air conditioner of capacity 1.5TR, refrigerator and water cooler of capacity 80/40 litres after leak testing of complete system and making good by bracing complete all as specified and directed.
S & F for PCB (Printed circuit board) of indoor unit suitable for existing 1.5 ton capacity split AC including removal of old existing unsv one complete all as specified and directed.
S & F for thermostat switch of any make of split AC 1.5 ton capacity including removal of old existing unsv one complete all as specified and directed.
Taking out of unserviceable swing motor and providing new swing motor of same quality and charecteristics suitable for any make of AC 1.5 / 2.0 Ton split / window type
Removing the old unserviceable sealed compressor unit from split AC of any make, capacity 1.5 TR and supply and fixing new hermetically sealed compressor of same make as that of the existing for split AC of capacity 1.5 TR with necessary mounting arrangements suitable for working with non CFC refrigerent including charging of non CFC refrigerent gas and oil at adequate level and jointing all pipe connection and checking gas pressure complete all as specified and directed.
Supply&Fixing LED street light Luminaries compressing pressure, die cast housing for better aesthetics and thermal management. with LED’s & drive, heat resistant flat glass suitable gasketed for IP65 protection, high grade power coating and fitted with toughened glass with high power LED’s of 60watt and pipe mounting arrangement for end mounting on bracket made out of 50mm dia GI pipe light grade, 1.2m long bent to shape with two sets of clamps made out of flat iron 50 x 6mm, bolts, nuts and washers and applying two coats of aluminium paint over on coat of red oxide zinc chrome primer connecting electrically with PVC mulitistranded copper cable of suitable size complete including taking down existing fittings all as specified and directed Make: Bajaj, Havells, Phillps, Wipro
Supply&Fixing light emitting diode flood light compressing pressure, die cast housing for better aesthetics and thermal management. Comprises of extruded aluminium housing with pre-wired gear tray with LED’s & drive, heat resistant flat glass suitable gasketed for IP65 protection, high grade power coating and fitted with toughened glass with high power LED’s of 150watt with PVC mulitistranded copper cable of suitable size complete including taking down existing fittings all as specified and directed Make: Bajaj, Havells, Phillps, Wipro
RSL Construction
MAHESWARI CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .