Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.1 LAdmitted-Finance | ₹29.1 L | L1 | Admitted-Finance |
| 2 | L2₹29.6 LAdmitted-Finance | ₹29.6 L | L2 | Admitted-Finance |
| 3 | L3₹36.0 LAdmitted-Finance | ₹36.0 L | L3 | Admitted-Finance |
| 4 | L4₹40.3 LAdmitted-Finance | ₹40.3 L | L4 | Admitted-Finance |
| 5 | L5₹41.1 LAdmitted-Finance | ₹41.1 L | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SHRI GANESH ENTERPRISES L5 | SUN LIGHT HOUSE L4 | M/s K L M INFRATECH L2 | omsai thermax engineers L7 | S.S.ENGINEERING CORPORATION L6 | SHILPA CONSTRUCTION COMPANY L3 | MM PROJECTS L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and replace invertor motors suitable for ABB.
Make : DC Switch (MOET4-T5220 250 AC / DC | 10 | Each | 60,000 ₹6 L | 38,000 ₹3.8 L | 30,000 ₹3 L | 63,000 ₹6.3 L | 18,500 ₹1.9 L | 30,060 ₹3.0 L | 24,000 ₹2.4 L |
| 2.00 | Servicing of inverter filters | 10 | Each | 2,000 ₹20,000 | 1,800 ₹18,000 | 1,500 ₹15,000 | 18,000 ₹1.8 L | 25,000 ₹2.5 L | 1,608 ₹16,080 | 1,000 ₹10,000 |
| 3.00 | Supply and replace 12 volts UPS battery Bank.
Make : Exide/Amaron | 2 | Each | 14,000 ₹28,000 | 18,000 ₹36,000 | 15,000 ₹30,000 | 20,000 ₹40,000 | 10,500 ₹21,000 | 16,080 ₹32,160 | 15,000 ₹30,000 |
| 4.00 | Supply and replace 110 volts DC Battery Bank of 55 x 2 Volts battery.
Make : Exide/Amaron | 2 | Each | 2,45,000 ₹4.9 L | 2,10,000 ₹4.2 L | 1,50,000 ₹3 L | 2,05,000 ₹4.1 L | 1,60,000 ₹3.2 L | 1,60,080 ₹3.2 L | 1,30,000 ₹2.6 L |
| 5.00 | Supply and replace Heavy Duty Coolers at Solar Inverter room for maintaining ambient temperature.
Make : Symphony / Bajaj / Havells | 3 | Each | 25,000 ₹75,000 | 30,000 ₹90,000 | 20,000 ₹60,000 | 18,000 ₹54,000 | 60,000 ₹1.8 L | 23,000 ₹69,000 | 19,500 ₹58,500 |
| 6.00 | Overhauling of LT main incomer at Solar Panel room | 1 | Job | 10,000 ₹10,000 | 8,900 ₹8,900 | 7,000 ₹7,000 | 45,000 ₹45,000 | 1,50,000 ₹1.5 L | 7,800 ₹7,800 | 5,000 ₹5,000 |
| 7.00 | Supply and replace unserviceable 230 / 235 watts capacity PV Modules of dimension 1660 x 990 mm | 50 | Each | 24,000 ₹12 L | 32,000 ₹16 L | 20,000 ₹10 L | 27,000 ₹13.5 L | 37,500 ₹18.8 L | 26,070 ₹13.0 L | 15,000 ₹7.5 L |
| 8.00 | Supply and replace 24 volts DC under voltage coil | 10 | Each | 8,000 ₹80,000 | 14,000 ₹1.4 L | 10,000 ₹1 L | 10,800 ₹1.1 L | 9,000 ₹90,000 | 12,030 ₹1.2 L | 8,000 ₹80,000 |
| 9.00 | M&L, locating fault in 11 KV HT underground cable of any sizes with the help of fault locator vehicle organized from TSSPDCL/TSTRANSCO by injecting necessary high voltage to the faulty cable within 12 hours of time from time of reporting of fault all as directed by Engineer in Charge.
Note: Quoted rate shall deemed to be included the necessary charges towards liaisoning for arranging fault locating vehicle, transportation of trained technicians and charges payable to Electricity Department. | 5 | Each Job | 25,000 ₹1.3 L | 45,000 ₹2.3 L | 30,000 ₹1.5 L | 45,000 ₹2.3 L | 25,000 ₹1.3 L | 35,070 ₹1.8 L | 23,000 ₹1.1 L |
| 10.00 | M&L in repairs, Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of plate not less than 1.5m below normal ground level connected to copper strip 20x3mm as earth lead by means of bolts, nuts, washers and check nuts made out of galvanized iron or steel all as shown on Electrical Plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed. | 10 | Each | 17,500 ₹1.8 L | 22,000 ₹2.2 L | 10,000 ₹1 L | 27,000 ₹2.7 L | 27,500 ₹2.8 L | 14,280 ₹1.4 L | 17,000 ₹1.7 L |
Updated dates
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
12 Feb 2026, 6:00 pmClosed
GE(I) R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
REPAIR MAINT OF 1 MW SOLAR POWER PLANT INCLUDING REPLACEMENT OF PV MODULES MAIN SUB ARRAY JUNCTION BOX 100 KW FULL WAVE SINE INVERTER 110 KW BATTERY CHARGER ETC AT RCI HYDERABAD
2026_MES_747665_1
8357
Open Tender
Electrical and Maintenance Works
180 days
GE(I) R AND D RCI, HYDERABAD
MES enlisted Class D category b ii enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE(I) R AND D RCI, HYDERABAD
₹80,000
Yes
3 Mar 2026
8 Jan 2026
14 Feb 2026
8 Jan 2026
12 Feb 2026
22 Jan 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: GE(I) R&D RCI HYDERABAD
Name of Work: REPAIR / MAINT OF 1 MW SOLAR POWER PLANT INCLUDING REPLACEMENT OF PV MODULES, MAIN/SUB ARRAY JUNCTION BOX, 100 KW FULL WAVE SINE INVERTER, 110 KW BATTERY CHARGER ETC AT RCI, HYDERABAD
Contract No: GE(I) RCI/HYD/ OF 2025-2026
Sl No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic Rate In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount With Taxes Total Amount In Words
Supply and replace invertor motors suitable for ABB. Make : DC Switch (MOET4-T5220 250 AC / DC 10 Each Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Note 1: The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, 50mm thick RCC 1:2:4 type B-1 using 20mm graded stone aggregate cover slab reinforced with 6 Nos of 8mm dia TMT bars both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe medium grade 25mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub-heading earthing, specified on Sl Page No. 422 of SSR Part-II. 2. Copper earth strip beyond 7.5m will be measured and paid separately.
Supply, replace, install and commissioning of Bucholz Relay suitable for Power Transformer of 132 KVA any make and 8 MVA capacity 1 Each Excess(+) Full Conversion INR
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
BOQ_837276.xls
BOQ • 0.28 MB
8357PS.pdf
Tender Documents • 0.35 MB
Download all tender documents and submit your bid