Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E)
BSNL ED Port Blair.
Electrical Repairing Works of 125 KVA EA set , AC Unit and other associated works in Telephone Bhawan , Port Blair in light of VVIP Visit
2023_BSNL_151373_1
08/ED/PB/2022-23
Open Tender
Electrical Works
Item Rate
30 days
Port Blair
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Accounts Officer (Cash)
₹2,670
21 Apr 2023
11 Apr 2023
21 Apr 2023
11 Apr 2023
20 Apr 2023
11 Apr 2023
Replacement of 3pole, 415V, 50 HZ, 200 A, MCCB in the existing control panel , i/c removing the faulty unit by disconnecting all lelectrical connections , connecting the existing cable / bus bar by proper lugging, termination,after fixing new MCCB complete as reqd ( Make L& T , Model DU 250 , Range -160-200 )
Replacement of 4pole, 415V, 50 HZ, 250 A, on load changeover switch with enclosure in the existing panel , i/c removing the faulty unit by disconnecting all lelectrical connections and connecting the existing cable / bus bar by proper lugging, termination,after fixing new changeover switch complete as reqd ( Make Havells , Model Euro Load Change over Switch ) i/c connecting the existing cable / bus bar by proper lugging, termination, complete as reqd.
Replacing of followingitems on EA Set control panel i/c removing the dammaded / faulty suitable for operating on single phase/three phase, 50 Hz a.c.supply, etc as reqd.
Replacement of Reset push button i/c removing the faulty one mad making connection to the new etc as required .
Replacement of Starting Key set ( ignition sysytem ) i/c removing the faulty one mad making connection to the new etc as required .
Repalcing of broken starting battery terminal of starting battery i/c soldering the cable to terminal etc as required
Supplying and fixing brass batten/ angle holder including connection etc. as required
Supplying and fixing LED lamp of 9 Watt, 230V, 50HZ, including including removinthe damaged/fused bulb from fitting etc. as required (Havells /Poly cab or SS make )
Servicing of 125 KVA DEA set ( Kirloskar make engine , 6R1080TA Type) thoroughly by replacing B-Check Kits such as oil filter, fuel filters, after flushing the sump after dismantling, checking of alignment and adjustment of different components like valve, tappet, replacing the head gasket, and assembling the engine parts i/c S/F of nuts & bolts, washers, spring washers, etc if required , testing, checking and commissioning, complete as reqd.
Supplying and pouring mobil oil of 20-W -40 grade in the E/A set complete as reqd. (Castrol/Indian Oil or SS)
Inspection of AC unit to diagonise the faults of the AC units by checking indoor & out door units i/c testing the gas pressure , Load current etc as required .
Dismantling and refixing of Out door fan Motor of 1.5 TR Split Air Conditioner Unit , from one out door unit by disconnecting all elelctrical and mechanical connections and fixing to by new out door unit i/c making all electrical, and mechanical connections to the installed fan , providing the missing fasteners, lugs, connectors, feruls, nuts and bolts, checking of connection,testing , complete as reqd.
General servicing & cleaning of 1.5 TR split Air Conditioner ( Both indoor and out door ) by removing all dirt and dust from the fins by heavy duty blower, and cleaning the fins/tubes with cleaning solution, combing the fins i/c painting the rusted parts of frame, cabinet, replacing the missing fasteners, lugs, connectors, feruls, nuts and bolts, checking of connection, complete as reqd.
Suupplying & Charging refrigerent R22/R134A/R407C in existing AC unit after leak testing with Nitrogen gas complete as required as per manufactures recommendations .
Supplying & fixing the following spares of good quality as per original sample as reqd.
a) 45/50 MFD starting capacitor
b) Starting Relay
c) Running capacitor
Supplying and fixing LED type tube light of 10/18 Watt type , 230V, 50HZ, including making all electrical connections with suitable size copper conductoor wire etc. as required ( Make Havells or SS make )
Supplying of ceiling fan 1200 mm sweep, suitable for 230V, 50 HZ, ac supply and installation, testing and commissioning of the same including wiring the down rods of standard length (upto 30 em) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required..etc. as required. ( Make Bajaj or SS)
Supplying and fixing of following size medium class PVC casing and caping along with accessories including cutting the wall and making good the same in caase of wal crossing asrequired .
(a) 20mm x 12 mm
Supplying and fixing of following size PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit /casing & caping etc as required
(a) 2x 1.5 Sqmm +1x 1.5 Sqmm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
10/6 A switch
3 pin 10/6 A socket outlet
Blanks
Television Socket outlet
Supplying and fixing suitable size plastic box with modular plate and cover in front on surface or in recess/on surface , etc. as required
Replacement of faulty semi sealed lead acid battery with new one 12 V 150 AH , initially charged including installing and testing as reqd. (Make:Exide/Standard Farukawa/ Presotlite/S)
SITC of 400 mm sweep oscilating type pedestal fan suitable for operation on 230V, 50Hz A/C supply i/c necessary power cord, etc. complete as reqd. (M/s Havells or SS make)
stage.html
html • 0.02 MB
finance_165667.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .