| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.1 LAccepted-AOC NO 422 CHURCH STREET NEW THIPPASANDRA BANGALORE 560075 | BANGALORE | BANGALORE | KARNATAKA | 560075 | ₹46.1 L Quoted ₹46.3 L | L1 | Accepted-AOC being L1 |
| 2 | L2₹52.1 L+₹5.7 L (12.3%)Rejected-Finance | ₹52.1 L+₹5.7 L (12.3%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹52.6 L+₹6.2 L (13.4%)Rejected-Finance 8 6TH CROSS MATHRU SHREE NILAYA OPP MAHARISHI RESIDENCE KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | ₹52.6 L+₹6.2 L (13.4%) | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹54.1 L+₹7.7 L (16.7%)Rejected-Finance BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | ₹54.1 L+₹7.7 L (16.7%) | L4 | Rejected-Finance Rejected being L4 |
| 5 | L5₹54.8 L+₹8.4 L (18.2%)Rejected-Finance NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | ₹54.8 L+₹8.4 L (18.2%) | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
16 Jan 2023, 6:00 pmClosed
GE I RD East Bangalore
GE I RD East Bangalore 93
CLEANING OF SEWAGE LINE MANHOLE SEPTIC TANK REPAIRREPLACEMENT OF SEWER LINE MANHOLES SOAKAGE MISC ITEMS AT ADE DEBEL LAB UNDER GEIRDEASTBANGALORE
2022_MES_571378_1
8328
Open Tender
Civil Works
Item Rate
270 days
GE I RD East Bangalore
D a (i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D East Bangalore
₹97,000
Yes
30 Mar 2023
26 Dec 2022
18 Jan 2023
27 Dec 2022
16 Jan 2023
7 Jan 2023
27 Dec 2022 - 5 Jan 2023
Amount
Excavation in trenches not exc 1.5m wide and not exc 1.5 m deep for foundation etc for manholes etc not exc 10 sqm on plan and not exc 1.5m depth and getting out in hard/dense soil.
Add to item No1 here-in-before, but for each additional 1.5m or part thereof in depth beyond first 1.5m in depth and getting out in any type of soil etc complete all as specified and directed.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil etc complete.
Removing excavated material exceeding 250m but not exc 500m and depositing where directed.
Demolition and breaking up salt glazed ware, AC or Reinforced concrete drain pipe including bedding layer set in cement mortar for 100mm dia pipe etc complete all as specified and directed.
Demolition and breaking up salt glazed ware, AC or Reinforced concrete drain pipe including bedding layer set in cement mortar for 150mm dia pipe etc complete all as specified and directed.
Demolition and breaking up salt glazed ware, AC or Reinforced concrete drain pipe including bedding layer set in cement mortar for 200mm dia pipe etc complete all as specified and directed.
Supply and lay Reinforced concrete pipes 100mm dia, class NP3, laid and jointed complete with collars as specified and directed by EIC.
Supply and lay Reinforced concrete pipes 150mm dia, class NP2, laid and jointed complete with collars as specified and directed by EIC.
Supply and lay Reinforced concrete pipes 200mm dia, class NP2, laid and jointed complete with collars as specified and directed by EIC.
M&L for Cement concrete bed to drain 1:3:6 type C-2 using 40mm graded stone aggregate to SWG drain pipe 100mm bore including packing under and haunching against the sides of pipes after they are laid and tested including removal of debries outside MD land all as specified and directed.
M&L for Cement concrete bed to drain 1:3:6 type C-2 (using 40mm graded stone aggregate) to SWG drain pipe 150mm bore including packing under and haunching against the sides of pipes after they are laid and tested including removal of debries outside MD land all as specified and directed.
M&L for Cement concrete bed to drain 1:3:6 type C-2 (using 40mm graded stone aggregate) to SWG drain pipe200mm bore including packing under and haunching against the sides of pipes after they are laid and tested including removal of debries outside MD land all as specified and directed.
Opening access door or cleaning eye of bends or junction of PVC/AC/CI pipe soil/waste) at any height from outside of building and cleaning by any means and flushing with clean water and refixing access door, all as specified and directed.
Desludging and cleaning completely manholes or inspection chamber of any size upto 1.5m depth including opening and placing of manhole cover, removal of sludge outside MD land, all as specified and directed.
Desludging and cleaning completely manholes or inspection chamber of any size exceeding 1.5m depth but not exc 3.0m depth including opening and placing of manhole cover, removal of sludge outside MD land, all as specified and directed.
Cleaning by any means SWG/CI sewage pipe lines from gully trap /inspection chamber to man holes or from manholes to manholes 150mm dia of pipe all including removal of sludge outside MD land as specified and directed.
Cleaning by any means SWG/CI sewage pipe lines from gully trap/ inspection chamber to man holes or from manholes to manholes 100mm dia of pipe all including removal of sludge outside MD land as specified and directed.
Cleaning by any means SWG/CI sewage pipe lines from gully trap /inspection chamber to man holes or from manholes to manholes 200mm dia of pipe all including removal of sludge outside MD land as specified and directed.
Cleaning of gully traps/inspection chamber of any size by any means including flushing by water complete all as specified and directed.
Cleaning and dewatering septic tanks with sludge, filter beds and clearing of manhole blockage by using sewage tankers mounted with pressure water jet and heavy duty sewage suction pump of capacity 3000 ltrs per hour and disposal ot the same to a distance exceeding 5 KM but not exceeding 10 KM from the suction point including cleaning manholes and septic tanks, manually as required to remove any unwanted materials of any kind etc all as directed and specified.
Cleaning and dewatering septic tanks with sludge, filter beds and cleaning of manhole blockage by using heavy duty sewage dewatering pump twice in a week and disposal in defence land to a distance exceeding 500 mtr from suction point including cleaning man holes and septic tanks, manually as required to remove any unwanted materials of any kind etc all as directed and specified. Note : Rate quoted by contractor includes bring sewage dewatering pump with FOL, cutting and cleaning of bushes, shrubs, jungle trees etc along the approach road, around septic tanks, filter beds.
Cleaning the blockages (from inside) in IPWCs/EPWCs/WHBs/ Urinals/kitchen traps etc, to the vertical stack pipe line by giving pressure including opening the / grating cover removal the blockage and foreign material; cleaning ways of the pipe including rodding, butch etc as required; all as specified and as directed by Engineer -in -charge.
Demolition of brick work/PCC block masonary built in cement mortar including quoins, arches, pillars etc and precast concrete articles and deposing off the rubbing materials outside MD land as specified and directed.
Material and labour for brick work for sub class 'B' bricks straight or curved on plan exc 6m means radius, built in cement mortar 1:4 complete all as specified and directed.
M & L for type B1, 1:2:4 (using 20mm graded stone gradedstone aggregate) as in pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete all as specified
Taking down cement or cement lime mortar plaster, any description on brick or stone walls etc, including rackingout joints, hacking for key, scrubbing down with water etc.
Material and labour rendering 15mm thick in cement plaster 1:4 on fair faces of brick work or concrete surfaces finishes the surfaces even and smooth without extra cement etc complete all as specified & directed.
Material and labour rendering 15mm thick in cement plaster 1:6 on fair faces of brick work or concrete surfaces finishes the surfaces even and smooth without extra cement etc complete all as specified & directed.
Demolition of cement concrete (reinforced) of any description and in position not otherwise specifically provided for complete all as specified and directed.
Supply and fixed TMT bars 10mm dia and over, cut to length, bent to shape required including cranking bending mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed confirmed to FE 410-0.
Material and labour for pre cast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in manholes cover slab etc, set in cement mortar 1:4 including necessary use and waste of form work complete all as specified and directed.
Material and labour for providing cement concrete 1:2:4 type BI (using 20mm graded stone aggregate) as in coping complete all as specified and directed.
Material and Labour for cement concrete type B2 1:2:4 (using 20 mm graded stone aggregate) as in surface channels and drains etc complete all as specified and directed.
S&F in repairs cast iron manholes cover .brackets, gully traps, grating etc articles exc 5 kg each etc
Cutting into existing manholes for connection new drains making good to pipes and rendering, cutting out existing benching for and forming branch channel in cement mortar 1:2:4 type B-1, smooth finished and reforming benching as required 150 mm dia pipe complete all as specified and directed.
All as per ser item No 36 above, but 200 mm dia pipe complete all as specified and directed.
All as per ser item No 36 above, but 100 mm dia pipe complete all as specified and directed.
Cleaning top surface of the RCC roof by brushing with wire brushes for removing caked mud etc sweeping with brooming and finally fanning the cleaned surface with funny bags to remove all loose dirt etc and removing from the site 5 to 10 km from the starting point as where directed by the Engr - in - Charge.
All as per item No 39 here-in-before, but AC sheet roofing /Steel sheet roofing complete all as specified and directed.
All as per item No 39 here-in-before, but valley gutters and down rainwater pipes complete all as specified and directed.
Cutting and removing grass, bushes, vegetable and unwanted plant growing near rainwater pipes and Y junction of sewar pipe near sanitary lines and parapet of roof, chajjas & shaft portion of building etc and surfaces finishes properly with plaster in cement mortar 1:1 and applying two coats of snowcem of complete panels.
Repairing, easing & refixing of doors, windows, ventilators, cupboard, for day to day urgent required works. carpenter with helper to be provided to concern JE, for works like taking down of doors/windows/ventilators/cupboard/window glass, Easing & refixing in same opening etc, material like hinges, screws of any type, rubber beads, door stoper are included in the job all as specified and as directed by EIC. carpenter shall be provided every working day except sundays and holidays, for attending and completing the complaint on same day before working hours with tools to carry out necessary cleanig Note :- the quoted rate shall be included providing safety gadgets to the deployed worker as per govt norms and holidays as per labour laws in vouge. minimum fair wages shall be maintained any dispute in this regard.
Dismantling Barbed Wire (including concertian coils) of any description including Serviceable Barbed Wire in Safe custody for reuse at Site, complete all as specified and as directed.
Dismantling mild steel work of any description like MS grills, MS angles in fencing over wall of height upto 4mtr and similar items.
S&F Mild steel work for posts and struts in fencing, Rungs/handles for manhole cover etc including cutting tops to shaps as directed, drilling holes, notching for wire etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
M&L cement concrete type B1 1:2:4 (using 20mm graded stone aggregate) as fixing of MS angles over wall of height upto 4mtr and as directed by EIC.
Restraining and resecuring including making good staples etc. for galvanised 2 Strand, Steel Bar-bed Wire (Serviceable Barbed Wire obtained from Item No. 44 here-in-before) including straining and fixing to any type of Standard Rails straining Bolts, securing or tying at cross -ings with and provision of Galvanised Mild Steel Wire, Staples or Steel Pins, etc, complete all as specified and as directed. NOTE: Cost of Mild Steel Binding Wire deem to be included in the quoted Unit Rate.
M&L for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (NOTE: Cost of Mild Steel Binding Wire deem to be included in the quoted Unit Rate. )
Supply and fix 350mm to 450mm dia punched type concertina coil having 51 spiral turns dia 1.75mm with 9 rows of clip and strutched upto 4 to 5 mtr to get a spiral difference of 150mm dia with 8.75 to 9 kg per coil complete all as specified and directed.
M&L 2 coats of synthetic enamel painting over a coat of red oxide primer on steel surfaces exc 10Cm width or grith including preperation of news urfaces complete all as specified and directed.
M&L one coat of synthetic enamel paint on over old steel surfaces exc 10cm width or grith including preperation of old surfaces complete all as specified and directed.
R R Constructions
ARCHANA CONSTRUCTION CO
RAHUL ENTERPRISES
PRAGATHI BUILDERS
SAI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .