Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC 47 C MODEL TOWN EXTENSION LUDHIANA PB | LUDHIANA | PUNJAB | 141001 | ₹1.6 Cr Quoted ₹1.7 Cr | L1 | Accepted-AOC rate approvved |
| 2 | L2₹17.0 L−₹1.5 Cr (89.8%)Rejected-Finance | ₹17.0 L−₹1.5 Cr (89.8%) | L2 | Rejected-Finance HIGH |
| 3 | L3₹1.7 Cr+₹6.4 L (3.84%)Rejected-Finance ABOHAR | ₹1.7 Cr+₹6.4 L (3.84%) | L3 | Rejected-Finance HIGH |
Tender Value
₹76 L
EMD Value
₹1.5 L
Closing Date
15 Nov 2022, 12:00 pmClosed
EXECUTIVE ENGINEER
ROPAR HEAD WORKS Division, ROPAR
Rehablitation of Lift Irrigation Scheme Village Tarapur, nanowal etc. RD 22575/left of ASHC
2022_WR_91013_2
15/22A/2022-23-1
Open Tender
Civil Works
Item Wise
120 days
ROPAR
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
₹1.5 L
22 Feb 2024
27 Oct 2022
15 Nov 2022
27 Oct 2022
15 Nov 2022
27 Oct 2022
Amount
Jungle clearance
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation
Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. Earth work upto 1.5 m. Depth, For Ordinary soil having gravel upto 40%
Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects.Exceeding 1.5 m depth but not exceeding 2.25 m depth, For Ordinary soil having gravel upto 40%
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. Earth work upto 1.5 m. Depth for, For Ordinary soil having gravel upto 40%
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. Exceeding 1.5 m depth but not exceeding 2.25 m depth, For Ordinary soil having gravel upto 40%
Restoration of road cut per 10 feet width of village road
Reinforced cement concrete M-20 with cement @375/kg per cum hand mixed but excluding steel reinforcement centring and shuttering in superstructure. (1:1.5:3)
Cement Concrete 1:3:6 with stone ballast or shingle. (100 mm thick)
Reinforced cement concrete M-25 with cement@425/kg per cum hand mixed but excluding steel reinforcement centring and shuttering in superstructure. (Perforated slab M25 Precasted)
First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth.
12.5 mm thick cement plaster 1:4 {Plaster (1:4)}
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in postion complete.
Shuttering for precast and plain or Reinforced concrete blocks, wall plates, bedplates, shelves etc.
Supply and installation of alfa valve including fittings etc complete in all aspects. 160 mm
Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with two coats of bitumen 20/30 penetration @1.65 kg per sqm laid hot and sanded.
20 cm thick cement plaster in demp proof course 1:3 with two coats of bitumen @1.65 kg per sqm laid hot and sanded.
12.50 mm thick CP 1:3
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
Providing & Fixing M.S Angle iron 40x40x6mm chowkhat i/c iron hold fast butt hinges fixed in position complete in all respect.
Wire gauge fixed on steel windows of std. rolled section with 3 mm flat iron cover moulding of 12.5 mm width complete in all respect.
Providing & Fixing 14 gauge MS sheet garage door with 40x40x6mm angle iron framed i/c locking arrangmets with handles etc. complete in all respect.
Base course of floor consisting of 100 mm thick cc 1:8:16 100 mm sand filling
Conglomerate floor 50 mm thick concrete topping 1:2:4
Preparation of plastered surfaces for painting (including sand pepering the surface) using ready mix cement based wall putty by applying two coats to get required finish.
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade(two coats)
Finishing walls with acrylic smooth exterior paint of required shade with two coats applied @1.67 lt/10 sqm over and including base coat of water proofing cement applied @2.20 kg/10 sqm.
Applying Priming Coats with metal primer on new steel or iron work i/c prepration of surface
Supply & erection of PVC pipes & HDPE pipes (fire retardant) for wiring purposes including bends, inspection boxes etc., where necessary including other petty material as per PWD General Specifications 2010:- Heavy gauge PVC conduit pipe 25mm dia. (ISI marked 2mm thick) Flushed
Miniature circuit breaker double pole 40amp. (Breaking capacity 10kA, Curve-C) suitable for 240/ 415 volts 50cycles AC supply
Providing, laying, jointing, fixing and testing H.D.P.E. / PVC Pipe lines, with G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.(15 mm i/d)
Supply and installation of pump and electric motor including electrical and mechanical fittings, complete in all aspects having service head of 24.90 meter (15Hp)
Supply and installation of wagon pump(vaccume pump) including electrical and mechanical fittings, complete in all aspects. (5Hp)
supply of double acting air release valve fitted with vaccume control valve for main riser
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves (250 mm) ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves (225 mm) ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves (200 mm) ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves (160mm) ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves (125mm) ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves (90mm) ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves (75mm) ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge).
Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete. (225mm)
Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete. (65mm)
Providing and fixing of rubber gasket/ring as per IS:5382/1952 for DI/CI/Pipe for making tyton joiting complete including cartage
S/O Bolts and Nuts of all sizes and length required
Providing & Fixiing C.I indicating plates of size 100mm x 100 mm for SV/FH including synthetic enammel paint & letters in white enamel paint, fixing in the ground with angle iron of size 25x25x5mm, 230mm height from ground including conrete block complete in all respect as directed by Engineer-in-charge
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 250mm o/d pipe of 6 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 225mm o/d pipe of 6 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 200mm o/d pipe of 6 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 160mm o/d pipe of 6 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 110mm o/d pipe of 6 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 90mm o/d pipe of 6 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 75mm o/d pipe of 6 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 63mm o/d pipe of 6 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 250mm o/d pipe of 4 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 225mm o/d pipe of 4 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 200mm o/d pipe of 4 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 160mm o/d pipe of 4 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 110mm o/d pipe of 4 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 90mm o/d pipe of 4 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 75mm o/d pipe of 4 Kgf. / sqcm
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 63mm o/d pipe of 4 Kgf. / sqcm
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. 80mm internal diameter
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. 100mm internal diameter
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. 150mm internal diameter
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. 200mm internal diameter
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts. 225mm internal diameter
Providing and laying, jointing, fixing, testing ISI Marked G.I. pipe For air vent Pipe (as per IS 1239) B- Class,premium make 50 mm dia such as (Jindal Hisar) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.
Construction of concrete protection column for 50 mm air vent G.I. pipe having dia 1 ft height 12ft Reinforced cement concrete 1:2:4 hand mixed as per Analysis (M-20)
Providing shuttering for construction of concrete protection column for 50 mm air vent G.I. pipe having dia 1 ft height 12ft Reinforced cement concrete 1:2:4 hand mixed as per Analysis (M-15)
Providing and applying injection grouting using cement slurry admixed with Fosroc Chemical Conplast WL or any other equivalent compound @ 300 ml/ Bag of cement through the uPVC nozzles ( 12mm dia uPVC/ Plastic Nozzles - 4" to 9" long @ 5 No: / Sqm of area) , provided into the cracks/ honeycombed areas using 140 PSI hand operated Grouting Pump under pressure till the refusal,doing final Cement slurry Grouting (after 28 Days),, finally cutting & sealing of Nozzle. including all labour, supervision, tools and tackles and transportation etc. complete as per direction of Enginner -in- charge.
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. B. Ordinary Soil (a) Depth upto 3 m by Mechanical Means
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. C. Ordinary Rock (not requiring (a) Depth upto 3 m by Mechanical Means
Cement Concrete 1:4:8 with stone ballast of size. (b) 40 mm gauge.
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth
Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure (upto 4m)
M-25 R.C.C. work done in each subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey (4-8m)
M-25 RCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 8-9m
M-25 RCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 9-10m
M-25 RCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 10-11m
M-25 RCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 11-12m
M-25 RCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 12-13m
M-25 RCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 13-14m
M-25 RCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 14-15m
M-25 RCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 15-16m
Rate for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC)
Rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey
Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved.-- Rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey(4-8m)
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 8-9m
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 9-10m
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 10-11m
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 11-12m
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 12-13m
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 13-14m
Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 14-15m
Centring and shuttering for columns (circular or curved in plain) (upto 4m)
Centring and shuttering for columns (circular or curved in plain)--Rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey(4-8m)
Centring and shuttering for columns (circular or curved in plain)--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 8-9m
Centring and shuttering for columns (circular or curved in plain)--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 9-10m
Centring and shuttering for columns (circular or curved in plain)--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 10-11m
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels(upto 4m)
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels--Rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey (4-8m)
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 8-9m
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 10-11m
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 13-14m
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels--Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 14-15m
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. (upto 4m)
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. --Rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey(4-8m)
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. --Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 8-9m
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. --Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 10-11m
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. --Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 15-16m
Centring and shuttering for stair cases with sloping with soffits including risers and stringers (upto 4m)
Centring and shuttering for stair cases with sloping with soffits including risers and stringers-- Rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey (4-8m)
Centring and shuttering for stair cases with sloping with soffits including risers and stringers-- Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 8-9m
Centring and shuttering for stair cases with sloping with soffits including risers and stringers-- Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 9-10m
Centring and shuttering for stair cases with sloping with soffits including risers and stringers-- Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 10-11m
Centring and shuttering for R.C.C. Domes----Rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey (4-8m)
Centring and shuttering for R.C.C. Domes-- Rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof 14-15m
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. (h) 350mm internal diameter
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees,bends,sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. (i) 200mm internal diameter
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends,sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. (e) 65mm internal diameter
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1.6 as per ISI, 250mm i/d Sluice Valves flanged.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1.6 as per ISI, 225mm i/d Sluice Valves flanged.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1.6 as per ISI, 200mm i/d Sluice Valves flanged.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1.6 as per ISI, 150mm i/d Sluice Valves flanged.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1.6 as per ISI, 100mm i/d Sluice Valves flanged.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1.6 as per ISI, 80mm i/d Sluice Valves flanged.
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. Class PN-1.0 as per ISI with gun metal flap, 250mm i/d Non-return valve
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. Class PN-1.0 as per ISI with gun metal flap, 250mm i/d Non-return valve
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. Class PN-1.0 as per ISI with gun metal flap, 225mm i/d Non-return valve
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. Class PN-1.0 as per ISI with gun metal flap, 200mm i/d Non-return valve
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. Class PN-1.0 as per ISI with gun metal flap, 150mm i/d Non-return valve
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. Class PN-1.0 as per ISI with gun metal flap, 125mm i/d Non-return valve
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. Class PN-1.0 as per ISI with gun metal flap, 100mm i/d Non-return valve
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra. Class PN-1.0 as per ISI with gun metal flap, 80mm i/d Non-return valve
Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete. C.I Double air valve (Size 100mm)
Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete. C.I Double air valve (Size 80mm)
Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete. C.I Double air valve (Size 65mm)
Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete. C.I Double air valve (Size 50mm)
Providing & fixing double air valve ISI Marked as per IS-14845 including jointing all carriages complete. C.I Double air valve (Size 40mm)
Supplying,fixing and testing at site Automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible / monoblock to be fixed on existing panel for OHSRs complete in all respects.
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. (i) 250mm
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. (ii) 200mm
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. (iii)150mm
Supplying, lowering & fixing of M.S Special socket to connect S.S Strainer to M.S Pipe duly welded with suitable grade welding electrode complete in all respect. (iv) 65mm
Providing, laying, fixing & jointing of P.V.C. Pipes ISI Marked as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (xii) 63mm o/d pipe of 6kgf/sqcm
Applying priming coat with metal primer on new steel or iron work including preparation of surface.
Painting two or more coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work
Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars riveted or molded forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
Advance Direction sign board 1200x900mm rectangular per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. grade sheeting fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.60x0.60x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 . (b) Using high intensity Microprismatic grade retro reflective Sheeting Type XI as per ASTM D 4956 09 and as per IRC 67 2012
Providing 7 W L.E.D. Solar Light with 7 mtr. Pole, battery, and all accessories and fixing it with 1:2:4 cement concrete in all respects and to entire satisfaction of Engineer-in- charge.
Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings complete in all respects. (i) 15mm internal diametre pipe line
Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings complete in all respects. (ii) 25mm internal diametre pipe line
Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings complete in all respects. (iii) 40mm internal diametre pipe line.
Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings complete in all respects.(iv) 80mm internal diametre pipe line.
Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings complete in all respects. (v)100mm internal diametre pipe line.
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. :Size 0.6 m. x 0.6 m.
Erection/Repair/Rewinding of Motor 15HP at site complete in all respects.
Erection/Repair/Rewinding of Motor 5HP at site complete in all respects.
Erection/Repair of Motor Pump fan at site complete in all respects.
Erection/Repair of vacuum pump at site complete in all respects.
Jain dori (12mm)
Coupling Rubber (L-190)
20 Watt LED LIGHT STREET with wall small angle band complete in all respects. (ISI MARKETS, USHA, HAVELLS AND GREAT WHITE ETE.)
23 Watt LED LIGHT BULB (ISI MARKETS, USHA, HAVELLS AND GREAT WHITE ETE.)
Ceiling fan ( ISI MARKETS, GREAT WHITE )
MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
MINIATURE CIRCUIT BREAKERS:- Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-(i)MCB Single Pole 0.5-4amp. (10kA, CurveC)
MINIATURE CIRCUIT BREAKERS:- Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-(ii) MCB Four Pole 6-32amp. (10kA, Curve-C)
MINIATURE CIRCUIT BREAKERS:- Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-(iii) MCB Four Pole 50, 63amp. (10kA, Curve-C)
Providing, installation & fixing in position of MPCB 14-23 Amp at site complete in all respects and to entire satisfaction of engineer-in-charge
Providing, installation & fixing in position of LC1D Contactor 32 Amp at site complete in all respects and to entire satisfaction of engineer-in-charge
Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 3 Nos. shrouded neutral bars, 3 Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label, compartmentalizing each phase (separated incomer, sub incomer & outgoing) and of required no. of ways for mounting FP MCB's as incomer, DP/RCBO's/RCCB's as sub incomer and SP MCB's as outgoings in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- TP&N Double Door Phase Segregated Distribution Board 8 way each
Supply and erection of sheet metal Iron Clad Changeover Switch on existing surface with G.I. bolts & nuts/rag bolts and nuts etc., according to the size of holes in the body of the switch including connections with suitable size of thimbles and bonding to the existing earth as per PWD General Specifications:-:CDP Changeover Switch 100amp., 415volts
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- (i)Overall size 1.5sq.mm (Un-sheathed)
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-(ii) Overall size 4sq.mm (Un-sheathed)
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- (iii) Overall size 10 sq.mm (Un-sheathed)
PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 16sq.mm (Un-sheathed)
Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 6.0sq.mm (56/0.3mm), 3Core
XLPE INSULATED ARMOURED CABLES (UNDERGROUND): Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:- Overall size 25sq.mm (4Core) Armoured (Underground)
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring fan point (Without fan box)
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete :Wiring light point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete :Wiring 6Amp. wall socket point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete :Wiring 6Amp. Plug control comprising wall socket point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete :Wiring 16/20Amp. power plug control point
Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete :Wiring light point with double control switches.
Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
Grease (2 kg packing)
Mobile oil (5 ltr. packing)
Nuts & Bolts of all sizes and length required
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends , sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 40mm internal diameter
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends , sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. 80mm internal diameter
Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends , sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. :100mm internal diameter
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends , sockets elbow etc., cutting, threading and testing in trenches in the ground complete. 15mm i/d
Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends , sockets elbow etc., cutting, threading and testing in trenches in the ground complete.25mm i/d
Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect :15mm i/d G.I. Union
Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect:40mm i/d G.I. Union
Providing, fixing and jointing ISI Marked GunMetal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete:40mm i/d Gun Metal peet valve heavy pattern.
Providing, fixing and jointing ISI Marked GunMetal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete:80mm i/d Gun Metal peet valve heavy pattern.
Providing, fixing and jointing ISI Marked GunMetal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete:100mm i/d Gun Metal peet valve heavy pattern.
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.6 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Class PN-1.6 as per ISI with gun metal flap:80mm i/d Non-return valve
Proving & fixing ISI Marked Non-return valves flanged end class PN-1.6 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete. Class PN-1.6 as per ISI with gun metal flap:100mm i/d Non-return valve
Supplying, Installation, Testing and Commissioning of Single suction collecting head with cast iron body, nose coupling (draw out connection) with female outlet complete bolts, nuts and rubber insertions, but without 100mm dia. MS suction pipe (with puddle flange) with a foot valve, complete as required.
Providing and fixing Vane type Water flow switch in MS Pipe line for a service pressure up to 450PSI , Minimum flow rate for alarm 10GPM (38 LPM ), Minimum surge 18 FPS (5.5 m/s ) including connection with panel complete in all respect:For 50mm to 150 mm pipe line
Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-:Aluminium thimble cable Core size 4-6 sq.mm
Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects.: (c) Earth work upto 1.5 m. Depth
Dismantling Brick Masonary
Dismantling First Class mud roofing
Providing and laying four courses of water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown type bitumen grade 85/25 applied hot at 1.20 Kg. Per sqm of area for each course second course on roofing felt type 3grade-1 (Hession base self finished bitumen felt) and fourth and final course of stone grit 6mm and down size or peasizes grit spread at 0.006cum per Sqm including preparation of surface complete.
Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS clamps.
Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
Raking out joints in lime or cement mortarand preparing the surface for repointing or replastering including disposal of rubish to the dumping ground within 50 m lead (excluding the cost of scraping of plaster and replastering).
12.5mm thick Cement Plaster 1:3
Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
Any Other Items
VARSHA CONSTRUCTION CO
Deepak Kumar Beetan
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .