GE RANGIA
GE Rangia C/O 99 APO Rangia
REPAIR TO REFRIGERATOR, AC, WATER COOLER, DEEP FREEZER AT RANGIA, CHANGSARI, TAMULPUR, DARRANGA AND HATTIGOR MILITARY STATIONS UNDER GE RANGIA
2020_MES_311382_1
8314/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
RANGIA, TAMULPUR, CHANGSARI, DARRANGA AND HATTIGOR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE RANGIA
₹50,000
Yes
25 Mar 2020
3 Jan 2020
28 Jan 2020
3 Jan 2020
27 Jan 2020
18 Jan 2020
Amount
M&L for cleaning the system with CTC and charging the refrigerant including replacing strainer and rectification of leakages in the system for water cooler having storage capacity of 150 ltrs complete all as specified and as directed by Engineer-in-charge.
All as per serial Item No. 1 above but for 120 ltrs capacity water cooler.
All as per serial Item No. 1 above but for 40/80 ltrs capacity water cooler.
S&F new thermetically sealed compressor in existing water cooler of 150 ltrs capacity including initial filling of refrigerant gas to the required pressure, brazing, electric/piping connections, etc., complete all as specified and as directed by Engineer-in-charge.
All as per serial Item No. 4 above but for 120 ltrs capacity water cooler.
All as per serial Item No. 4 above but for 120 ltrs capacity water cooler.
M&L for replacement of thermostat switch suitable for water coolers of any capacity including knobs, plates and screws complete all as specified and as directed by Engineer-in-charge.
S&F in repair starting relay suitable for water coolers upto 150 ltrs capacity complete all as specified and as directed by Engineer-in-charge.
S&F in repair over load protector suitable for water coolers upto 150 ltrs capacity complete all as specified and as directed by Engineer-in-charge.
S&F in repair starting capacitor suitable for water coolers upto 150 ltrs capacity complete all as specified and as directed by Engineer-in-charge.
S&F in repair running capacitor suitable for water coolers upto 150 ltrs complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repair push/lift cock 15mm bore of brass, chromium plated, ISI marked for water cooler of any capacity complete all as specified and as directed by Engineer-in-charge.
S&F in repair ball valve brass with polyethylene ball of 15mm complete all as specified and as directed by Engineer-in-charge.
M&L for internal wiring of water coolers with 40/0.0076 size conforming to relevant IS PVC flexible copper conductor wire single core with terminal clips, etc including replacement of screws, washers, etc required for fastening with body etc complete all as specified and as directed by Engineer-in-charge.
Taking down burnt fan motor and rewinding of fan motor with suitable size of copper conductor including replacement of bushes, rubber mounting clips and refixing and testing of water cooler upto 150 ltrs capacity complete all as specified and as directed by Engineer-in-charge.
M&L for preparing external surfaces of water cooler 40/80 Ltrs capacity, removing existing paint and applying two coats synthetic enamel paint (as approved colour shade) with spray machine over a coat of red oxide zinc chrome primer and writing MES No., etc. complete all as specified and as directed by Engineer-in-charge.
All as per serial Item No. 16 here-in-before but for water cooler of 120/150 ltrs capacity.
S&F in repair water tray made out of 2mm thick GI sheet for water cooler of any capacity with outlet system connection provided with and including PVC nylon braided pipe of 20 mm dia upto 3 mtr length and also connecting to drain pipe etc complete all as specified and as directed by Engineer-in-charge.
Supply and fix PVC pipe 25mm bore with and including fittings and necessary saddles fixed on wall etc. for outlet drain etc. complete all as specified and as directed by Engineer-in-charge.
M&L for removing rusted/defective sheet metal from water cooler of 40/80 litre capacity of any make by proper cutting and replacement with same thickness of sheet as per existing shape and design by proper welding and applying two coats of painting with spray machine over a coat of red oxide zinc chrome primer, complete all as specified and as directed by Engineer-in-charge.
All as per serial Item No. 20 here-in-before but for Water Cooler of 120/150 ltrs Capacity.
Taking down defective deep freezer of 300/310/396/400 litre capacity, transportation from MES store yard/site to workshop and back including re-fixing /reinstallation after taking out defective/burnt compressor & providing new compressor of same capacity from authorised dealer including flushing of condenser and charging with required quantity of appropriate refrigerant including reconnection of all electrical connections and testing of deep freezer, complete all as specified and as directed by Engineer-in-charge.
M&L for removing rusted/defective sheet metal from deep freezer upto 400 ltrs capacity of any make and by proper cutting and replacement with same thickness of sheet as per existing shape and design by proper welding and applying two coats of painting with spray machine over a coat of red oxide zinc chrome primer, complete all as specified and as directed by Engineer-in-charge.
M&L for cleaning & overhauling of condenser coil of Deep Freezer 300/310/396/400 ltrs capacity, detecting the leakage in the coil and rectify it by using carbon-di-oxide gas welding, brazing, charging with appropriate refrigerant gas with required quantity to the system and testing, complete all as specified and as directed by Engineer-in-charge.
M&L preparing external surfaces of Deep Freezer upto 400 ltrs capacity, removing existing paint and applying two coats of synthetic enamel paint (of approved colour shade) with spray machine over a coat of red oxide zinc chrome primer and writing MES No., etc., complete all as specified and as directed by Engineer-in-charge.
Dismantling of existing defective unserviceable compressor of any capacity from window, split AC, refrigerators and water coolers, complete all as specified and as directed by Engineer-in-charge.
S&F new thermetically sealed compressor in existing Window type AC, 1.5 Ton capacity including initial filling of refrigerant gas to the required pressure, brazing, electric/piping connections etc, complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 27 here-in-before but for 2 TR capacity.
All as per serial item No. 27 here-in-before but for Split type AC 1.5 TR capacity.
All as per serial item No. 27 above but for Split type AC of 2 TR capacity. Note for Sch 'A' serial item No. 27 to 30 - The contractor shall submit original purchase vouchers alongwith manufacturer's test certificate and guarantee card etc. The quoted rates shall also be deemed to include undertake guarantee of one year from certified date of completion by the contractor for free replacement of compressor and/or rectification of the same (including charging of gas).
M&L for recharging of refrigerant R-410A to the compressor unit/in position (install location) complete including testing of leakage and testing the unit for satisfactory performance complete all as specified and as directed by Engineer-in-charge.
M&L for replacing unserviceable spare parts of window & split type AC of capacity 1.5/2.00 TR of approved make and required size to suit existing AC including taking out the unserviceable spare parts from AC, complete all as specified and as directed by Engineer-in-charge. Note - Spare parts shall be measured and paid separately.
Supply only the following spare parts suitable for window & split type AC of capacity 1.5/2 TR :-
Fan Motor of window AC
Blower fan motor of split AC.
Air Filter suitable of AC (Window Type) 1.5/2.0 TR Capacity
Air Filter suitable of AC (Spilt Type) 1.5/2.0 TR Capacity,
Capacitor Running 36 mfd – 45 mfd
Capacitor starting 100 mfd – 120 mfd
Fan Motor Blades
Fan Motor Capacitor 4 mfd
Fan Motor Capacitor 6 mfd
Runner for Air Blower Motor of AC (Split Type) Make : USHA/LG
Single Pole Contactor 25 Amp Capacity, MR 11 Watt Type suitable for split AC
S&F in repair Copper pipe 10mm bore suitable for window/split type AC including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F in repair Copper pipe 15mm bore suitable for window/split type AC including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F in repair Front Plastic Grill (as per Sample) of AC (Window Type) including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F in repair Front Plastic Grill for Inner Unit (as per Sample) of AC (Split Type) including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F in repair Remote Circuit Board with Remote of AC (Split Type) 1.5/2.0 TR Capacity including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F in repair Starting Relay of AC including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F in repair Strainer with Capillary Tube including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F in repair Thermostat Switch including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F in repair SPN DB two way without bus bar with MCB single pole and neutral 32 Amp including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
S&F in repair cooling and condensing coil including brazing complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of flexible PVC insulated copper conductor cable 3 core 70/0.0076 size conforming to relevant IS complete all as specified and as directed by Engineer-in-charge.
Material & Labour for cleaning and servicing of indoor and out door units of split type AC 1.5/2 TR capacity by pressure washing with water and testing after completion of servicing complete all as specified and as directed by Engineer-in-charge.
Material & Labour for cleaning and servicing of window type AC 1.5/2 TR capacity by pressure washing with water and testing after completion of servicing complete all as specified and as directed by Engineer-in-charge.
S&F in repair wall bracket suitable for mounting of 1.5/2 TR split AC outdoor unit on wall with nut and bolt including fixing of outdoor unit on bracket including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
Supply and charging with suitable refrigerant including detecting of leakage and its rectification and testing, complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of over load relay for refrigerator complete all as specified and as directed by Engineer-in-charge.
M&L for recharging of gas and testing the leakage system for refrigerator of 165 / 170 / 175 / 180 / 190 / 220 / 230 / 250 / 300 / 310 / 315 ltrs capacity complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of door liner (plastic) as per original for 286/300 ltrs capacity of refrigerator complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of cooling and condensing unit of refrigerator including welding complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of door magnetic gasket as per original make for any capacity of refrigerator complete all as specified and as directed by Engineer-in-charge.
S&F new thermetically sealed unit suitable for refrigerator of 165 liter capacity as per existing make including taking down old unserviceable one complete all as specified and as directed by Engineer-in-charge.
All as per serial item No. 56 above but for 220/230 ltrs capacity refrigerator.
All as per serial item No. 56 above but for 250 ltrs capacity refrigerator.
All as per serial item No. 56 above but for 300 ltrs capacity refrigerator.
All as per serial item No. 56 above but for 310/315 ltrs capacity refrigerator.
M&L for removing rusted/defective sheet metal from refrigerator of 165/170/175180/190/220 /230/250/300 /310 /315 ltrs capacity of any make and by proper cutting and replacement with same thickness of sheet as per existing shape and design by proper welding and applying two coats of painting with spray machine over a coat of red oxide zinc chrome primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing external surfaces of refrigerator of 165/170/175/210/315 Litre capacity including removing existing paint and applying two coats synthetic enamel paint (of approved colour shade) with spray machine over a coat of red oxide zinc chrome primer and writing MES No. etc., complete all as specified and as directed by Engineer-in-charge.
Taking down fully automatic servo motor operated voltage stabilizers 5 KVA capacity from the site and transporting to workshop for necessary repair/replacement of defective components such as over and under voltage coil, servo motor, volt meter, toggle switch, PCB Board, transformer, etc., servicing and reassembling the same and re-installing at the same position & connecting to split/window type AC and testing on completion complete all as specified and as directed by Engineer-in-charge. Note : Spares parts shall be measured and paid separately.
Supply only under/over voltage release coil suitable for 5 KVA stabilizer complete all as specified and as directed by Engineer-in-charge.
M&L for rewinding of transformer suitable for 5KVA servo operated, with correct gauge super enameled copper conductor cable with existing gauge and size and proper insulation, varnishes etc. as in repair complete all as specified and as directed by Engineer-in-charge.
Supply only voltmeter 0-300 Volt single phase AC 50 Hz complete all as specified and as directed by Engineer-in-charge.
Supply only toggle switch increase and decrease of voltage as required complete all as specified and as directed by Engineer-in-charge.
Supply only PCB board complete with proper soldering and connecting with the circuit connection complete all as specified and as directed by Engineer-in-charge.
Taking out of servo motor assembly from the stabilizer and cleaning it properly with blower and apply greasing to the rotating mechanism and reinstalling the same with stabilizers complete all as specified and as directed by Engineer-in-charge.
Supply only LED type lamp of existing shape and size complete all as specified and as directed by Engineer-in-charge.
S&F in repair copper lugs, pin type, suitable for 2.5 sqmm and 4 sqmm copper conductor cable with soldering etc complete all as specified and as directed by Engineer-in-charge.
S&F in repair 2 KVA Voltage Stablizer for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 130V to 300V with output voltage stabilized at 220V with accuracy of + 5%, complete all as specified and as directed by Engineer-in-charge.
S&F in repair 5 KVA Voltage Stablizer for automatic operation, single phase, naturally air cooled, indoor type and designed for input variation between 130V to 300V with output voltage stabilized at 220V with accuracy of + 5%, complete all as specified and as directed by Engineer-in-charge.
M&L for replacement of corroded / damaged bottom plate / sheet including welding of legs, denting and removal of existing paint including scraping the old faded paint and applying 2 coats of synthetic enamel paint over a coat of anti-corrosive primer using mechanical sprayer on replaced part of water cooler complete all as specified and as directed by Engineer-in-charge.
S&F in repair metal clad protected plug and socket complete 2 pin top and an earth plug, 230 V, 20 Amp complete all as specified and as directed by Engineer-in-charge.
S&F in repair MCB, single pole & neutral, 6 to 32 Amps, 240 volt, complete all as specified and as directed by Engineer-in-charge.
Disconnecting indoor and outdoor unit of split type AC of capacity 1.5TR/2TR and refixing the same with new mounting bracket made out of 50 x 50 x 6mm thick MS angle iron frame including necessary required PCC and masonary work complete including reconnecting the new copper pipe with new insulation to the indoor and outdoor unit complete gas charging i.e Mafron - 22 and testing, complete all as specified and as directed by Engineer-in-charge.
S&F 4 Sqmm two single core PVC insulated cables with standed FRLS copper conductor 1100 V for sub main wiring (Red and black colour) and drawing in to and including PVC casing and capping 20mm wide with all fitting including 4 Sqmm PVC insulated stranded FRLS copper conductor cable earth continuity conductor (green colour) complete including taking down unserviceable cable, complete all as specified and as directed by Engineer-in-charge. Note:-Two runs of 4 sqmm cable, one run of 4 sqmm cable alongwith casing capping shall be measured as one length for measurement & payment.
S&F 1100 volts grade heavy duty 16 sqmm cable PVC insulated stranded aluminum conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connection twin core cable flat or circular including taking down old unserciveable cable, complete all as specified and as directed by Engineer-in-charge.
S&F 1100 volts grade heavy duty 10 sqmm cable PVC insulated stranded aluminum conductor served with inner sheathing of PVC tape and overall PVC sheathed for service connection twin core cable flat or circular including taking down old unserciveable cable, complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S NARAYAN ENTERPRISE
M/S S.S. Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .