Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.2 CrAccepted-AOC 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹4.2 Cr | L-1 | Accepted-AOC Being L-1 Bidder |
| 2 | L-2₹4.2 Cr+₹1.9 L (0.47%)Rejected-Finance | ₹4.2 Cr+₹1.9 L (0.47%) | L-2 | Rejected-Finance Not being L1 Bidder |
Tender Value
₹4 Cr
EMD Value
₹4.8 L
Closing Date
22 Aug 2023, 6:00 pmClosed
CHIEF ENGINEER AF SHILLONG ZONE
HQ CHIEF ENGINEER AF SHILLONG ZONE MILITARY ENGINEER SERVICES ELEPHANT FALLS CAMP PO NONGLYER SHILLONG 793009
ADDN ALTN IMPROVEMENT TO SECURITY INFRASTRUCTURE ALONGWITH WATCH TOWER AND ASSOCIATED WORKS AT AF STN HASIMARA
2023_MES_605369_1
88458/HAS/E8
Open Tender
Civil Works
Lump-sum
545 days
GE (AF) HASIMARA
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE (AF) HASIMARA
₹4.8 L
Yes
27 Sept 2023
24 Jun 2023
24 Aug 2023
24 Jun 2023
22 Aug 2023
8 Aug 2023
Amount
SCHEDULE "A" Part - I (BUILDINGS/STRUCTURES WORK) Details of Buildings are given here-in-before:-
Construction of Watch Tower in Triple Storey configuration with permanent specification including RCC framed construction, sloped roof, mosquito proofing, ATT, seismic provision for zone V and APP roof treatment complete all as specified and as shown on drawings.
Construction of Admn Room in Single Storey configuration with permanent specification including RCC framed construction, sloped roof, mosquito proofing, ATT, seismic provision for zone V and APP roof treatment complete all as specified and as shown on drawings.
Construction of Dog Kennel in Single Storey configuration with permanent specification including RCC framed construction, sloped roof, mosquito proofing, ATT, seismic provision for zone V and APP roof treatment complete all as specified and as shown on drawings.
Construction of Ladies Toilet in Single Storey configuration with permanent specification including RCC framed construction, sloped roof, mosquito proofing, ATT, seismic provision for zone V and APP roof treatment complete all as specified and as shown on drawings.
Construction of Guard Rest Room in Single Storey configuration with permanent specification including RCC framed construction, sloped roof, mosquito proofing, ATT, seismic provision for zone V and APP roof treatment complete all as specified and as shown on drawings.
Construction of Sub Guard Room in Single Storey configuration with permanent specification including RCC framed construction, sloped roof, mosquito proofing, ATT, seismic provision for zone V and APP roof treatment complete all as specified and as shown on drawings.
Construction of Open Covered Shed at Katra Vihar and MES Gate with MS post, MS trusses including Galvalume sheet roof covering complete all as specified and as shown on drawings.
Construction of Open Covered Shed at QMQ Gate with MS post, MS trusses including Galvalume sheet roof covering complete all as specified and as shown on drawings.
SCHEDULE "A" PART- II ( SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- III ( INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV ( INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- V (ROAD/PATH) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VII (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- IX (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART- X (STANDBY SUPPLY) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XI (FENCING AND GATE) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART- XII (DEMOLITION /DISMANTLING) Details of prepriced Schedule is given in tender documents
SCHEDULE "A" PART -XIII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' F ' signifies this fact only.
INTERNAL ELECTRIFICATION S & F energy efficient 200 mm dia PVC air ventilating fan, complete with louvers by making hole to the existing wall, making good to the disturbed surface as per existing including connecting with suitable size of copper conducting wire up to nearest ceiling rose complete all as specified and directed.
S&F LED (4 x 1) mounting Flat panel luminaire suitable for hanging on any surface/ ceiling with necessary hook /chain for hanging the fitting from ceiling /Roof /Angle Iron Frame struture including connecting three core cable 1.5 sqmm up to nearest point complete with separate electronic driver & high brightness LEDs white colour complete all as specifed & directed.
S&F VTPN prewired distribution board TPN-DPX 63 MCCB with provision for one No MCCB 63 Amps as incomer and suitable MCB as outgoing double door type sheet metal enclosure 415V with 200 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable for 4 way complete all as specified and as directed by Engineer-in-Charge. Note : Cost of MCCB and MCB SPN/SP/TP shall be measured and paid seperately under respective items.
Material & Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3 mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion complete all as specified and directed.
Supply and fix of wall mounted industrial type high speed oscillating type air circulators iron body of size 450 mm (18") with regulator, single phase complete with suitable fixing arrangment on Angle iron complete all as specified and directed.
INTERNAL WATER SUPPLY S & F brass angle stop cock CP high pressure with capstan head long shank screwed down 15 mm dia bore omplete all as specified and directed.
ROAD/ PATH M & L for 200mm thick (compacted thickness) GSB (Granular Sub Base) in shingle or gravel in two layers of 100mm thick each over compacted grading as per Grade I as specified Table 400-1 of MoRTH specifications for Road and Bridge works, 2013, in a single layer over compacted subgrade with natural sand, crushed gravel, crushed stone, crushed slag or combination thereof as per the grading required The materials are mechanically mixed, spread and leveling on the subgrade by using motor grader of adequate capacity, and rolling with vibratory roller of capacity 80-1 00 KN static weight for achieving required compaction density of atleast 98% of the Maximum Dry Density. Consolidating to required gradient and camber complete all as specified and directed with finished surface tolerances as per Table 900-1 of MoRTH specifications for Road and Bridge works, 2013 complete all as specified and directed.
SEWAGE DISPOSAL Construction of LLDPE Septick tank 2000 ltr conventional type, designed to carry out sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent, shat connection etc all as per manufacturers' instruction and complete all as specified.
Construction of brick masonary Soakage Well for 10 users complete all as specified and as shown on drawings.
EXTERNAL WATER SUPPLY M & L for Construction of valve pit chamber 150 mm thick 1:4:8 PCC base having internal dimension 900x 900x900mm at grond surface and extended to 100 mm height from GL with 50 x50x 6 mm MS angle frame collar gruted in 100 mm thick 1:2:4 PCC layer on top surface of brick masonray CM (1:4) inside outside plastering with CM(1:4) complete. 50x50x5 MS angle framing top cover of 3.15 mm thick MS black sheet with 2 diagonals of 45x5 MS flat and fabricated with 2 nos heavy duty hinge and 2 nos D shape handle of suitable dimension including two coats of alluminium paint over a coat of red oxide zinc chrome primer on external & internal steel surfaces and two coats of black bituminous paint on hidden steel surfaces including necessary excavation and earth work in any type of soil as directed by Engr - in -charge.
EXTERNAL ELECTRIFICATION Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40 mm dia conforming to IS, approved colour with fittings for cable protection complete all as specified and directed.
Supply, Installation and Commissioning 16 Mtrs Motorised High Mast having provision for 210 Watt 08 Nos LED FLOOD LIGHT LUMINAIRES Thickness : Top -3 mm , bottom -4 mm , Diameter : 150 mm , bottom 410 mm , wide spread 180 Km/Hr , Intergral motor , 6 mm Hoisting SS ropes Drouble Drum Winch, Movable Landern Carriage , 5 core 4 sq mm Trailing Cable , Lightning Final , Anchor plate and Template . Hot dip Galvanised system Internally and Externally Including necessary foundation ,foundation Bolts and Nuts with including following with two luninaire mounting arm, pulley assembly, including LED aviation obstruction light, lightening arrestor spike, monkey menance spike with including suitable Tmer panel RCC Foundation as per manufacturer instruction complete, suitable for 08 Nos 210 Watt LED Flood lights all as specified and directed by Engineer-in-Charge . Note: Rate quoted shall be inclusive for necessary earth work for installation at any type of Soil and following and Luminaires installed in High Mast will be measured and paid seperately. Note :- 1. A Vandal and weather proof door with provision to padlock is to be provided to have clear access to the base compartment equipments like winch, motor, cable, termination etc;. The base flange welded to high mast shaft develops full strength of the section. 2. Winches are completely self sustaining with out the need of any break/spring/clutch, self lubricating by means of oil bath, worm gear driven of ratio 53:1, grooved drums for tidy and smooth rope lay. The winch is designed to install or remove through the mast door. Name plate is provided giving the details of type of winch, SWL, operating speed and year of manufacturing and instruction plate for the type of the lubricant.
Condt from Item No.23.00 here-in-before 3. Stainless steel wire ropes in grade 304 or 316 in flexible 7/19 construction (central core is also of same material) of various diameters to have factor of safety more than 5 specified in the TR No-7. Ropes for 2 wire rope, DD type winches have both ends with factory fitted talurit and thimble and copper crimping. 4. The standard luminary's carriage in two halves is of welded construction fabricated from durable round steel tube for aerodynamic effect and to act as conduit with holes in bottom side to take the wiring flexible cable. Arms with circular profile for mounting luminaries are welded to the ring. HDG clamps with S.S hardware are provided to mount the CG boxes and balance the weight oncarriage to avoid eccentric load. Legs are welded to anchor the wire rope for 2 or 3 ropes. 5. Provision of lightening arrestor spike along with earthing connection and canopy to fix the hot dip galvanized lightening finial fabricated out of ERW tube.
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 25X 4 mm dia by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge.
M&L for Earthing of Equipment complete with Copper earth plate electrode 60×60cm.× 3.15 mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15 cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe ( light grade) wire mesh, copper lugs, complete in all respect,including Copper earth strip 20 x 3.15 mm , 40 mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, including necessary earth work and incl disposal of soil to a distance not exc 50 mtr and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-charge. Note : Earth result after installation completely should be less than 2 Ohm.
Supply and fixing HT Bus Bar box outdoor type , factory made CPRI approved Powder coated inner and outer shell made out of 3.15mm thick MS sheet , IP 66 protection on angle iron framing 50x50x6 mm MS with cannopy on top spread out 15 cm from top, HT resin cast moulded bushing fitted on 12 mm glass fibre inside top plate suitable for 11KV with 3 Nos copper bus bar 400 amp current capacity separated with fire retardent separator mounted on HT Insulator 06, duly powder coated painted externaly and internaly and danger marking of 11000 volt complete of size 1.0X1.5X1.0 metre including all cable jointing nuts bolts made of brass/ HS steel of sutable size and PCC for grouting of Joint Box to be fixed 02 feet height from ground level including dismatling the existing junction box complete all as directed by the engineer –in- charge. Note: Necessary earth work , PCC foundation for installation of Junction box, Taking out the HT UG Cable loop for connection / Providing the HT Joint and Refix the Cable after installation of New Junction Box including dismatling the Existing junction box shall be deemed to be uncluded in unit Rate.
S&F LED flood light 50/60W including fixing on frame of roof trusses of Sun Shelters with all fixing accessories complete with connecting wire 1.5 sqmm, 3 core upto ceiling rose complete all as specifed & directed.
STANDBY SUPPLY Supply and laying double walled corrugated (DWC) HDPE duct pipe of 50 mm dia conforming to IS, approved colour with fittings for cable protection complete all as specified and directed.
Supply, installation, commissioning and testing of Silent diesel engine driven generating set 415 Volts, 3 Phase 4 wire, engine as per IS 10001/10002, ISO-3046, BS-5514, DIN-6271 of capacity 40 KVA, 4 stoke, desgined to run continuously at 1500 RPM complete with the following accessories :- (a) Diesel Engine :- (i) Radiator Cooling (ii) Radiator fan with guard (iii) Fly wheel with starter ring (iv) Dry tupe air cleaner (v) Vacuum indiactor (vi) Mechenical governor (vii) Exhaust silencer (viii) Fuel Filter (ix) Inline fuel pump (x) Water pump (xi) Lub oil Filter (xii) 24V electric start system complete with starter, battery charging alternator (xiii) Engine control panel consisting of starting key switch, lub oil pressure guage, ammeter safety shut down system for low lube oil pressure and coolant temperature engine maintenance manual with spare parts list. (xiv) Exhaust pipe / stack upto 6m from the top of shed with insulation structural steel required for support exhaust pipe / stack, fixed supports, sliding supports etc (xv) First fill of lube oil and coolant. (xvi) Residential silencer eith cladding & supports (xvii) Fitment of RECD (Retro Emission control device) as per CPCB norms of suitable capacity and as per manufacturer guidelines. (b) Alternator Alternator conforming to IS-13364 with standard design with IP 23 protection, suitably rated at 40 KVA at 0.8 PF, 415 Volts, 3 phase, 4 wires, 50 Hz, 1500 RPM, self excited brushless excavation and self regulated, band of voltage regulation +/- 1.5% of rated voltage (from no load to full load) and "H" class insulation, alternator should be mounted on common single base frame and coupled directly to the engine.
Condt from Item No.30.00 here-in-before (f) Spare parts & tools :- (i) Rotary pump diesel with 3 mtr hose - 01 Set (ii) Box spaner set complete with all sizes (iii) Oil filter set - 02 Nos (iv) Air filter complete with element - 02 Nos (v) AVR - 01 (vii) Insulated rubber matt of size 900 mm x 1500 mm x 3mm thick - 02 Nos (viii) Jerrican MS Sheet capacity 20 Ltr - 02 Nos (ix) First Aid Box, Tool Box with daily use spaner and tools etc Note :- (i) DG Set shall be tested at site as type test routine as per IS in presence of senior authorised service Enginner of OEM and rep of Accepting Officer. (ii) Contractor shall submit Two year warranty of Engine and Alternator , contol Panels including AMC during the DLP. (iii) The contractor shall get approval of GE for the make of DG Set as per CA specification, they plan to procure. (iv) Prior manufacturing the general arrangment drawing design details of the DG Set and AMF Panel shall be got approved by GE.
Supply, Installation, testing & Commissioning of Silent Diesel Engine Generating Set complete all as per item No 30.00 here-in-before but AMF pannel suitable for capacity 15 KVA and with an addl fuel tank of capacity 400 ltr.
S & F swiwel type search light of capacity 2000 watt HPMV AC 220 V duly mounted on MS fabricated stand suitable to swiwel at 360 degree and height adjustment mechanism with automatic controlled servo motor complete all as specified and directed by Engr-in-Charge.
M&L for Earthing of Equipment complete with Galvanised earth plate electrode 60×60cm× 6 mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to existing earth lead strip by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15 cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe ( light grade) wire mesh, copper lugs, complete in all respect,including GI earth strip 32x6mm , 40 mm bore (medium grade) galvanized iron pipe up to earthing test point as directed, including necessary earth work and incl disposal of soil to a distance not exc 50 mtr and necessary testing on completion complete all as specified and as directed by the Engineer-in-charge.
FENCING AND GATE S&F CONSEC-ZAL Super Razor punched barb tape (SRPBT) Aluminium base helix coil with and including necessary GI fixing clips for securing complete all as specified and directed with following specifications:- (i) Dia of coil (when unstretched) - 610mm (ii) No of circles-51 turns per coil (iii) Weight of each coil with hessian pack - 8.50 Kg( +0.5 ) (iv) Coverage per coil - 6 RM Note :- Running length of the wall shall be measured for payment purpose.
Note:- Schedule of credit (Sch 'A' Part- XIV) amount of Rs 37,700.00 shall be deducted from the total quoted amount of BOQ.
B D Raizada Projects Pvt Ltd
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .