| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC C O GANESH PRASAD RIVER VIEW COLONY GURUDWARA ROAD HATIA NAMKUM RANCHI JHARKHAND 834003 | RANCHI | RANCHI | JHARKHAND | 834003 | L1 | Accepted-AOC L1 BASIS | |
| 2 | L2₹6.5 L+₹27,510.78 (4.42%)Rejected-AOC AT C O S M JABIR NEAR HOT LIPS RESTAURANT KANKE ALIAS PAHAR GONDA RO RANCHI UN MISIR GONDA RANCHI JHARKHAND 834008 | RANCHI | JHARKHAND | 834008 | L2 | Rejected-AOC L1 BASIS | |
| 3 | L3₹7.2 L+₹95,900.37 (15.4%)Rejected-AOC | L3 | Rejected-AOC L1 BASIS | |
| 4 | L4₹7.4 L+₹1.2 L (19.3%)Rejected-AOC | L4 | Rejected-AOC L1 BASIS | |
| 5 | L5₹7.4 L+₹1.2 L (19.4%)Rejected-AOC PUNCHSHEEL NAGAR PANDRA RANCHI | RANCHI | CHATRA | JHARKHAND | 834005 | L5 | Rejected-AOC L1 BASIS |
Tender Value
₹10.3 L
EMD Value
₹13,000
Closing Date
7 Mar 2025, 10:00 amClosed
SO EnM GNH
Office of SO EnM GNH
Wiring of 5 Nos General Wards Nurses duty room and washrooms along with installation of Nurses calling modules and rearrangement of air conditioners of Jubilee I Block of GNH
2025_CCL_330443_1
CMS(I/C)/GNH/EnM/24 25/12
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
GNH
Please refer Tender documents.
2 documents required · 2 mandatory
₹13,000
4 Jun 2025
26 Feb 2025
10 Mar 2025
26 Feb 2025
7 Mar 2025
26 Feb 2025
26 Feb 2025 - 1 Mar 2025
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modularbase & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MOB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240V, onsurface/recess, complete with tinned copper bus bar,neutral busbar, earthbar, dinbar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MOB DB complete with connections, testing and commissioning etc. as required. Triple pole and neutral
Supplying and fixing extra conduit down rod of 20cm length G.I.pipe 15mm dia, heavy gauge including painting etc. as required. (Note:More than 5cm length shall be rounded to the nearest 10cm and 5cm or less shall be ignored)
Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipeof 2.7metre long etc.with charcoal/coke and salt as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface/recessed steel conduit of following pairs, cores and size including connections and inter connections etc. as required. Speaker cable Single pair, 2-core, 1.5 sqmmMetre
Supply & fixing of 18 Watt LEDs
Supply & Fixing of LED Tube Light 20 Watt
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLSP VC insulated copper conductor,single core cable in surface/ recessed medium class PVC conduit as required. 4X 16 sq. mm + 2 X 6 sq. mm earth wire
Providing and fixing following ratingand breaking capacity and pole MCCB withther momagnetic releaseand terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel,making connections, etc. as required 100 A, 16 KA,TPMCCB
Supply & Installation of Wireless Bed Call Units -Stdbed unit,"Nurse call button" -Bed unit"Reset Button" -Handset Call Unit with two meter cable with AC adapter/battery
Supply & Installation of Wireless Display & Control systems for nurse call systems for 24 beds -Display -Total 24 Beds to display at a time -Pre-recorded audio announcement
Dismantling & reinstallation split Acs with gas charging & extra copper pipe with insulation as required
Providing and fixing 4.00mm dia copper wire on surface or in recess for loop earthing as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plates witch box including connections but excluding modular plate etc. as required.
Total impact of GST for the purpose of CTC
RACE ELECTRICAL (BID ID -1136423)
AA ENTERPRISES (BID ID -1134004)
M/S SHREE BALAJEE ENG.CO. (BID ID -1136487)
RAVI RANJAN SINGH (BID ID -1135232)
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .