| 1 | 1₹5.1 CrAccepted-AOC D 11 47 SURAJPUR INDUSTRIAL AREA SITE 5 GREATER NOIDA GAUTAM BUDH NAGAR UTTAR PRADESH GAUTAM BUDDHA NAGAR UTTAR PRADESH 201306 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201306 | ₹5.1 Cr Quoted ₹5.2 Cr | 1 | Accepted-AOC L1 |
| 2 | 2₹5.9 Cr+₹71.2 L (13.8%)Rejected-Finance NEAR GAURAV ICE FACTORY LOHARU ROAD CHARKHI DADRI 127306 | CHARKI DADRI | HARYANA | 127306 | ₹5.9 Cr+₹71.2 L (13.8%) | 2 | Rejected-Finance L2 |
| 3 | Not Admitted-Fee/PreQual/Technical DHANI CHANDPUR BAWAL ROAD REWARI DHANI CHANDPUR BAWAL ROAD REWARI 123401 | REWARI | REWARI | HARYANA | 123401 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | HITECH ENVIRO ENGINEERS AND CONSULTANTS PVT LTD L1 | VIKASH BADESRA CONT L2 |
|---|---|---|---|---|---|
| 1.00 | Providing, Installation, Testing and Commissioning of Twin Lobe Air blowers with Induction Motors (1500 Rpm) of Capacity 1105 m3/ H @ 0.6 Kgf/cm2 for Aeration in SBR reactors (2W plus 2S) | 4 | Nos. | 4,00,000 ₹16,00,000 Lowest | 7,00,000 ₹28,00,000 |
| 2.00 | Providing, Installation, Testing and Commisiioning of Decanter type Centrifuge Machines with Solids handling Capacity Upto120 Kgs/Hr, able to achieve 20% Consistency in Dried Sludge with 90-95 % Separation Efficiency with Operating Speed of 3000-3200 rpm and 30-35 KW Motor 2 (1W plus 1S). The Centrifuge machines shall be Supplied and Installed with all Accessories from Poly dosing Pumps of appropriate capacity, Outlet solids funnel, with necessary spares such as Intermediate kit Conveyor bearings, main bearings, lubricants , Cables, Panels and all associated works hereto to the Satisfaction of Engineer in Charge: | 2 | Nos. | 18,00,000 ₹36,00,000 | 14,00,000 ₹28,00,000 Lowest |
| 3.00 | Supply ,Installation , Testing and Commissioning of EOT Crane for Chlorine Toners with Gantry Rail arrangement of 2 Tonne Capacity , 12m Span, SS-304 Lifting Chain, Length of Chain not less than 12 m, Speed of Hoisting, 3m /Min, Cross Travel 12m wih all Electrical Cables, Panels and Related Works Complete in all respect as Per Specifications of DNIT and Satisfaction of the Engineer in Charge. | 1 | Nos. | 3,00,000 ₹3,00,000 Lowest | 6,00,000 ₹6,00,000 |
| 4.00 | HT panel-Design, Providing, Installation, Testing and Commissioning of Indoor type floor Mounted Extendable type, Metal Clad, totally enclosed, 1 Breaker Panel 11 KV, 3 Phase, effectively earthed, short circuit withstand capacity of26.3 KA for three Seconds. Vaccum Circuit breakers , Earthing trolley as per IS: 13118, Panel Board single break, trip free, motorised spring charged with electrical closing arrangement with horizontal draw out and horizontal isolation type VCB with mechanical ON/OFF indicatorand trip device , 4 NO plus 4 NC auxillary contact complete with self contained, fully interlocked, rackrack in and rack out mechanism as per IS 13118, as ammendedupto date specifications, with 800 A Capacity aluminium bus bars and bottom entry gland plate suitable for 3 x 150 sqmm, 11 KV XLPE cable . Cable of Required Size and Length from VCB Panel to Panels of STP is included in Scope of works | 1 | Nos. | 10,50,000 ₹10,50,000 | 5,50,000 ₹5,50,000 Lowest |
| 5.00 | Supply, Testing, Jointing, Commissioning of Cables of Required Sizes as per the Estimate attached with in Annexure B | 1 | Nos. | 5,00,000 ₹5,00,000 Lowest | 15,00,000 ₹15,00,000 |
| 6.00 | Supply of Safety Equipments- 3 Oxygen Cylinders-3 Kg Portable Type, 8 Safety Belts, 8 Helmets, 8 Set of Safety Shoes, 5 Fire Extinguishers-2Kg Each, Oxidised Saftey Chain-50m, Rope 25 mm 100m, 8 Set of Satey goggles and gloves, Safety Jackets-15, PPE Kit-3 | 1 | Nos. | 1,00,000 ₹1,00,000 Lowest | 2,50,000 ₹2,50,000 |
| 7.00 | Supply, Fixing, Erection and Testing of FRP Cable Trays for Cables of various sizes at different locations of STP, Thickness minimum 5mm | 1 | Job | 2,50,000 ₹2,50,000 Lowest | 3,50,000 ₹3,50,000 |
| 8.00 | Supply , Installation, Testing , commissioning of Ultrasonic Level Sensors/ Flow Meters having measuring range of .1m to 3m with Electrical Panel, MS mounting of 8mm thickness sheet, Epoxy Painted and Calibration with Internet Optical Fibre Connection, Transfer to required websites (HPCB, CPCB, PHED and other mandatory web portals) and all associated works , complete in all respect upto the satisfaction of Engineer in Charge: Ultrasonic Flow meters at Outlet Channel of STP, with Data logger (5 Years O n M data transfer Charges to be Included.) | 1 | Job | 4,15,000 ₹4,15,000 Lowest | 4,25,000 ₹4,25,000 |
| 9.00 | Supply, Fixing , Testing and Commissioning of CCTV cameras with 2 TB hard Disk, 32 Inches LED Screen, with cables, Electrical works. 1 No CCTV camera of 360 degrees 8 Mega Pixel night vision Installed at Main Gate . 6 No CCTV cameras at SPT, 1 No at MPS, 2 No at SBR Basins, 1 No at Fine Screens and Grit Channels, 1 No at Outlet and CCT, 1 No at Centrifuge with Data transfer to required web Portals with high Speed Internet Optical fibre connection | 1 | Nos. | 2,20,000 ₹2,20,000 | 2,00,000 ₹2,00,000 Lowest |
| 10.00 | Supply, Installation, Testing and Commissioning of Electromagnetic Double layered Flow meter suitable for 300mm id, Sewage carrying DI pipe for Rising mains to Inlet Box and transfer of Flow meter data to Required web portals for a Period of 5 Years with dedicated Internet Connection through Optical Fibre Cable and Modem with all electrical cables, panel , with LED display. Data logger , Flanges, Specials, Hodi/ Casing of Flowmeter shall be in scope of Works: | 1 | Job | 6,50,000 ₹6,50,000 | 4,55,000 ₹4,55,000 Lowest |
Tender Value
₹6.5 Cr
EMD Value
₹13.0 L
Closing Date
27 Mar 2026, 1:00 pmClosed
JITENDER SINGH
Narnaul PHED No. 2
Rough Cost Estimate for Renovation and Revamping of 6.0 MLD SBR based STP at Narnaul (Formerly Under MC Narnaul)
2026_HRY_506680_1
20260B09EFB6 7938 4DC4 BC2E 8B6DD586A43D599PUH
Open Tender
Civil Works
Works
365 days
Narnaul
2 documents required · 2 mandatory
₹20,000
₹13.0 L
Yes
PHED No.2, Narnaul
18 Aug 2026
6 Mar 2026
27 Mar 2026
6 Mar 2026
27 Mar 2026
6 Mar 2026
6 Mar 2026 - 8 Mar 2026
9 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing, Installation, Testing and Commissioning of Twin Lobe Air blowers with Induction Motors (1500 Rpm) of Capacity 1105 m3/ H @ 0.6 Kgf/cm2 for Aeration in SBR reactors (2W plus 2S) | 4 | Nos. | - | - |
| 2 | Providing, Installation, Testing and Commisiioning of Decanter type Centrifuge Machines with Solids handling Capacity Upto120 Kgs/Hr, able to achieve 20% Consistency in Dried Sludge with 90-95 % Separation Efficiency with Operating Speed of 3000-3200 rpm and 30-35 KW Motor 2 (1W plus 1S). The Centrifuge machines shall be Supplied and Installed with all Accessories from Poly dosing Pumps of appropriate capacity, Outlet solids funnel, with necessary spares such as Intermediate kit Conveyor bearings, main bearings, lubricants , Cables, Panels and all associated works hereto to the Satisfaction of Engineer in Charge: | 2 | Nos. | - | - |
| 3 | Supply ,Installation , Testing and Commissioning of EOT Crane for Chlorine Toners with Gantry Rail arrangement of 2 Tonne Capacity , 12m Span, SS-304 Lifting Chain, Length of Chain not less than 12 m, Speed of Hoisting, 3m /Min, Cross Travel 12m wih all Electrical Cables, Panels and Related Works Complete in all respect as Per Specifications of DNIT and Satisfaction of the Engineer in Charge. | 1 | Nos. | - | - |
| 4 | HT panel-Design, Providing, Installation, Testing and Commissioning of Indoor type floor Mounted Extendable type, Metal Clad, totally enclosed, 1 Breaker Panel 11 KV, 3 Phase, effectively earthed, short circuit withstand capacity of26.3 KA for three Seconds. Vaccum Circuit breakers , Earthing trolley as per IS: 13118, Panel Board single break, trip free, motorised spring charged with electrical closing arrangement with horizontal draw out and horizontal isolation type VCB with mechanical ON/OFF indicatorand trip device , 4 NO plus 4 NC auxillary contact complete with self contained, fully interlocked, rackrack in and rack out mechanism as per IS 13118, as ammendedupto date specifications, with 800 A Capacity aluminium bus bars and bottom entry gland plate suitable for 3 x 150 sqmm, 11 KV XLPE cable . Cable of Required Size and Length from VCB Panel to Panels of STP is included in Scope of works | 1 | Nos. | - | - |
| 5 | Supply, Testing, Jointing, Commissioning of Cables of Required Sizes as per the Estimate attached with in Annexure B | 1 | Nos. | - | - |
| 6 | Supply of Safety Equipments- 3 Oxygen Cylinders-3 Kg Portable Type, 8 Safety Belts, 8 Helmets, 8 Set of Safety Shoes, 5 Fire Extinguishers-2Kg Each, Oxidised Saftey Chain-50m, Rope 25 mm 100m, 8 Set of Satey goggles and gloves, Safety Jackets-15, PPE Kit-3 | 1 | Nos. | - | - |
| 7 | Supply, Fixing, Erection and Testing of FRP Cable Trays for Cables of various sizes at different locations of STP, Thickness minimum 5mm | 1 | Job | - | - |
| 8 | Supply , Installation, Testing , commissioning of Ultrasonic Level Sensors/ Flow Meters having measuring range of .1m to 3m with Electrical Panel, MS mounting of 8mm thickness sheet, Epoxy Painted and Calibration with Internet Optical Fibre Connection, Transfer to required websites (HPCB, CPCB, PHED and other mandatory web portals) and all associated works , complete in all respect upto the satisfaction of Engineer in Charge: Ultrasonic Flow meters at Outlet Channel of STP, with Data logger (5 Years O n M data transfer Charges to be Included.) | 1 | Job | - | - |
| 9 | Supply, Fixing , Testing and Commissioning of CCTV cameras with 2 TB hard Disk, 32 Inches LED Screen, with cables, Electrical works. 1 No CCTV camera of 360 degrees 8 Mega Pixel night vision Installed at Main Gate . 6 No CCTV cameras at SPT, 1 No at MPS, 2 No at SBR Basins, 1 No at Fine Screens and Grit Channels, 1 No at Outlet and CCT, 1 No at Centrifuge with Data transfer to required web Portals with high Speed Internet Optical fibre connection | 1 | Nos. | - | - |
| 10 | Supply, Installation, Testing and Commissioning of Electromagnetic Double layered Flow meter suitable for 300mm id, Sewage carrying DI pipe for Rising mains to Inlet Box and transfer of Flow meter data to Required web portals for a Period of 5 Years with dedicated Internet Connection through Optical Fibre Cable and Modem with all electrical cables, panel , with LED display. Data logger , Flanges, Specials, Hodi/ Casing of Flowmeter shall be in scope of Works: | 1 | Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
BOQ_585427.xls
BOQ • 0.33 MB
AD0150969.pdf
Additional Documents • 12.29 MB
OT0150969.pdf
Other Document • 0.20 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .