Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 001 HPS MARKET KANPUR GANDHI CHAURAHA RAEBARELI UTTAR PRADESH 229206 | RAE BARELI | UTTAR PRADESH | 229206 | Accepted-Technical Documents are found in order |
Tender Value
₹1.4 L
EMD Value
₹2,704
Closing Date
1 Apr 2026, 12:00 pmClosed
Assistant Engineer (Elect)
3rd Floor, E Block, Pushpa Bhawan Madangir, New Delhi 110062
Providing and installation of energy efficient 5 Star ACs in Room No. 115 DIG (RR) office, Room No. 618 DIG (Welfare) office and Room No. 711 Comdt (Confd) office at Block No. 4 and 10 of CGO complex under FHQ BSF New Delhi.
2026_BSF_902139_2
24/NIT/ENGG/ELECT/2025-26
Open Tender
Electrical Works
Percentage
15 days
HQ DG BSF Block No 10
As per NIT
9 documents required · 9 mandatory
₹0
₹2,704
7 Apr 2026
24 Mar 2026
2 Apr 2026
24 Mar 2026
1 Apr 2026
24 Mar 2026
24 Mar 2026 - 1 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.0 | Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
(1.1) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | - | Mtr | - | - |
| 1.2 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | - | Mtr | - | - |
| 0.0 | HI - WALL SPLIT SYSTEMS
Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), surface/ concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz , 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll/ rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/ International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only Make : Daikin/ Voltas/ Blue star/ Hitachi
(2.1) 1.5 TR with 5 Star BEE Rating | - | Each | - | - |
| 0.0 | Providing and fixing 3 pin, 16 Amp, 240 volt plug top on existing power socket including connection etc. complete as required. Anchor make or it's equivalent to Havells/ Goldmedal/ Standard | - | Each | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.77 MB
NITACDIGRR.pdf
Tender Documents • 1.75 MB
BOQ_949625.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .