GE Utility Electric Supply
GE Utility Electric Supply DELHI CANTT-10
REPAIR AND MAINTENANCE LT PANEL ACBS MCCBS EARTHING AND CONNECTED ITEMS AT BI LINE ABDUL HAMID VIHAR ABDUL HAMID VIHAR FAMILY QTR ARJAN VIHAR PRATAP CHOWK AREA MANDIR MARG AHPU TAURAS ENCLAVE AEPTA STATION ROAD SHOPPING CENTRE MYNAMATI LINES BALWAN
2026_MES_794686_1
GE ELECT/TOKEN-57/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Utility Electric Supply
AS PER TENDRE DOCUMENTS
7 documents required · 7 mandatory
₹500
GE Utility Electric Supply
₹92,000
17 Oct 2026
17 Oct 2026
10 Nov 2026
17 Oct 2026
7 Nov 2026
31 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT Panel board ,cubical compartmentalized , out door type double door , plate form mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated aluminium bus bars four pole installed on porcelain/SMC insulator. The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement including internal wiring with PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade of appropriate size ( but not less than 2.5 Sqmm) and comprising of the following complete all as specified and directed by Engr-in-Charge :-
(a) Incoming :-
(i) MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA, with microprocessor release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter 0-250 Amp digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 800- set of four
(b) Outgoing
(i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos. (ii) MCCB 4 pole , 160 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 04 Nos.
(c) Platform of Panel. Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
Note :-
(i) All out going feeder shall be connected by cable through suitable size gland plate / glands.
(ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
(iii) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt.II/1993 (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer | 1 | Each Job | - | - |
| 2 | All as in item No 1 here-in-before but comprising of the following complete all as specified and directed by Engr-in-Charge :-
(a) Incoming :-
(i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 35 KA, with microprocessor release - 01 No
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter 0-250 Amp digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 250/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 500- set of four
(b) Outgoing :-
(i) MCCB 4 pole , 63 Amps, 50 Hz,415 Volts, 25 KA with thermal magnetic release - 06 Nos
(ii) MCCB 4 pole , 160 Amps, 50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos | 1 | Each Job | - | - |
| 3 | All as in item No 1 here-in-before but comprising of the following complete all as specified and directed by Engr-in-Charge :-
(a) Incoming :-
(i) MCCB 4 pole , 630 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter 0-250 Amp digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 800- set of four
(b) Outgoing;-
(i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 09 Nos. | 1 | Each Job | - | - |
| 4 | All as in item No 1 here-in-before but comprising of the following complete all as specified and directed by Engr-in-Charge:-
(a) Incoming :-
(i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter 0-250 Amp digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 500- set of four
(b) Outgoing :-
(i) MCCB 4 pole, 100 Amps, 50 Hz, 415 Volts, 10 KA with thermal magnetic release - 01 Nos .
(ii) MCCB 4 pole, 63 Amps, 50 Hz, 415 Volts, 16 KA with thermal magnetic release - 04 Nos
(iii) MCCB 4 Pole,125 Amps, 50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos. | 1 | Each Job | - | - |
| 5 | All as in item No 1 here-in-before but comprising of the following complete all as specified and directed by Engr-in-Charge :-
(a) Incoming :-
(i) MCCB 4 pole , 630 Amps,50 Hz,415 Volts, 36 KA, with microprocessor release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 600/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 1200 Amps- set of four
(b) Outgoing
(i) MCCB 4 pole , 100 Amps, 50 Hz, 415 Volts, 25 KA with thermal magnetic release - 09 Nos (ii) MCCB 4 pole , 63 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 02 Nos | 1 | Each Job | - | - |
| 6 | All as in item No 1 here-in-before but comprising of the following complete all as specified and directed by Engr-in-Charge :-
(a) Incoming :-
(i) MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA, with microprocessor release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter 0-200 Amp digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 800 Amps- set of four
(b) Outgoing;-
(i) MCCB 4 pole , 100 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 04 Nos
(ii) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos | 1 | Each Job | - | - |
| 7 | All as in item No 1 here-in-before but comprising of the following complete all as specified and directed by Engr-in-Charge :-
(a) Incoming :-
(i) MCCB 4 pole , 400 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos
(ii) Onload Changeover switch 400 Amp-01 Nos
(iii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iv) Ammeter digital type with 4 way rotary selector switch-01No
(v) CTs ratio 400/5 A ,class 1, ISI marked -01 sets of three
(vi) Indicating lamp- 01 set of three
(vii) Aluminium bus bar of rating 800 Amps- set of four
(b) Outgoing
(i) MCCB 4 pole , 160 Amps, 50 Hz,415 Volts, 27 KA with thermal magnetic release - 01 Nos
(ii) MCCB 4 pole , 125 Amps , 50 Hz,415 Volts, 27 KA with thermal magnetic release - 01 Nos
(iii) MCCB 4 pole , 100 Amps , 50 Hz,415 Volts, 27 KA with thermal magnetic release - 02 Nos
(iv) MCCB 4 pole ,63 Amps , 50 Hz,415 Volts, 27 KA with thermal magnetic release - 02 Nos | 1 | Each Job | - | - |
| 8 | All as in item No 1 here-in-before but comprising of the following complete all as specified and directed by Engr-in-Charge :-
(a) Incoming :-
(a) Incoming :-
(i) MCCB 4 pole , 250 Amps,50 Hz,415 Volts, 25 KA, with microprocessor release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 500- set of four
(b) Outgoing
(i) MCCB 3 pole , 63 Amps,50 Hz,415 Volts, 10 KA with thermal magnetic release - 09 Nos | 1 | Each Job | - | - |
| 9 | All as in item No 1 here-in-before but comprising of the following complete all as specified and directed by Engr-in-Charge :-
(a) Incoming :-
(i) MCCB 4 pole , 200 Amps,50 Hz,415 Volts, 36 KA, with thermal magnetic release - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 200/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 400 Amps- set of four
(b) Outgoing
(i) MCCB 3 pole , 63 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 01 Nos
(ii) MCCB 3 pole , 32 Amps,50 Hz,415 Volts, 25 KA with thermal magnetic release - 05 Nos | 1 | Each Job | - | - |
| 10 | All as in tem No 1 here-in-before but comprising of the following complete all as specified and directed by Engr-in-Charge :-
(a) Incoming :-
(i) ACB 4 pole, 800 Amp, 50 KA, 415 Volt AC Horizontal draw out type motorized, front operated with Microprocessor based LCD protection release for adjustable over current, short circuit and earth fault protection - 01 Nos
(ii) Voltmeter 0-500 volts digital type with 4 way rotary selector swicth -01No
(iii) Ammeter digital type with 4 way rotary selector switch-01No
(iv) CTs ratio 800/5 A ,class 1, ISI marked -01 sets of three
(v) Indicating lamp- 01 set of three
(vi) Aluminium bus bar of rating 1200- set of four
(b) Outgoing
(i) MCCB 3 pole , 250 Amps,50 Hz,415 Volts, 36 KA with microprocessor release - 03 Nos
(i) MCCB 3 pole , 200 Amps,50 Hz,415 Volts, 25 KA with microprocessor release - 03 Nos | 2 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
TD57.pdf
Tender Documents • 0.76 MB
BOQ_891275.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .