Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.3 L+₹2.6 L (10.6%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹28.4 L+₹3.8 L (15.4%)Rejected-Finance 2 RC ENTERPRISES NEAR AGRASEN BHAWAN BHATAPARA CHHATTISGARH LINK ROAD BALODA BAZAR RAIPUR CHHATTISGARH 493118 | BALODA BAZAR | CHHATTISGARH | 493118 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹32.7 L+₹8.1 L (32.8%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹35.2 L+₹10.6 L (42.9%)Rejected-Finance NO 1 KAMAM STREET SELAIYUR CHENNAI 600073 | CHENNAI | CHENNAI | TAMIL NADU | 600073 | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | rc enterprises L3 | Global Safety Engineering and Management Solutions L6 | Vishwa Enterprises L5 | M/s Bakiyalakshmi Enterprises L4 | SJM CONSTRUCTIONS L1 | Vinayaga steel industries L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete and making good of the disturbed surface of wall, floors etc complete all as specified and directed by Engineer-in-Charge. | 470 | Point | 5 ₹2,350 Lowest | 470 ₹2,20,900 | 10 ₹4,700 | 7 ₹3,290 | 5 ₹2,350 Lowest | 10 ₹4,700 |
| 2.00Material and Labour for Point wiring complete with 1.50 sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including non metallic rigid PVC conduit accessories concealed on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxes concelled/surface in wall with suitable modular white cover plate with frame for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated FRLS copper conductor for continuous earth wire and connected to common earth dolly for the following :- | |||||||||
| 2.01 | One light /fan point controlled by one 5/6 Amps switch. | 100 | Point | 275 ₹27,500 | 500 ₹50,000 | 400 ₹40,000 | 377 ₹37,700 | 400 ₹40,000 | 190 ₹19,000 Lowest |
| 2.02 | One 3 pin 5/6 Amps socket outlet on same board | 20 | Point | 275 ₹5,500 | 150 ₹3,000 | 400 ₹8,000 | 137 ₹2,740 | 100 ₹2,000 | 50 ₹1,000 Lowest |
| 2.03 | 3 pin 5/6 Amps socket outlet on independent board | 50 | Point | 275 ₹13,750 | 500 ₹25,000 | 400 ₹20,000 | 377 ₹18,850 | 450 ₹22,500 | 190 ₹9,500 Lowest |
| 2.04 | One call bell point controlled by one bell push | 10 | Point | 275 ₹2,750 | 500 ₹5,000 | 400 ₹4,000 | 397 ₹3,970 | 450 ₹4,500 | 190 ₹1,900 Lowest |
| 2.05 | One 3 pin socket outlet 15/16 Amps independent with cable 2.5Sqmm size. | 20 | Point | 300 ₹6,000 | 700 ₹14,000 | 500 ₹10,000 | 427 ₹8,540 | 450 ₹9,000 | 195 ₹3,900 Lowest |
| 2.06 | One 3 pin socket outlet 15/16 Amps independent with cable 4.0Sqmm size. | 20 | Point | 300 ₹6,000 | 800 ₹16,000 | 500 ₹10,000 | 447 ₹8,940 | 650 ₹13,000 | 199 ₹3,980 Lowest |
| 3.00Material and Labour for Point wiring complete with 1.50sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including PVC casing & caping/PVC conduit on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxes concealed in wall with 3 mm thick hylam sheet for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated FRLS copper conductor for continious earth wire and connected to common earth dolly for the following :- | |||||||||
| 3.01 | One light point/fan point controlled by one 5 Amps switch | 100 | Point | 350 ₹35,000 | 500 ₹50,000 | 400 ₹40,000 | 307 ₹30,700 | 400 ₹40,000 | 150 ₹15,000 Lowest |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
12 Aug 2025, 6:00 pmClosed
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
REPAIR MAINT TO INTERNAL ELECTRIFICATION INCLUDING FANS GEYSERS AND REPAIR MAINT OF LED STREET SOLAR LIGHTS SECURITY LIGHTS AT MADAMBAKKAM NARENDRA PLACE AND 9 P AND S AFS TAMBARAM
2025_MES_720611_1
GE(AF)/TBM/8825/E8
Open Tender
Civil Works
Item Rate
270 days
AIR FORCE STATION TAMBARAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹85,000
Yes
29 Aug 2025
15 Jul 2025
14 Aug 2025
15 Jul 2025
12 Aug 2025
29 Jul 2025
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete and making good of the disturbed surface of wall, floors etc complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Point wiring complete with 1.50 sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including non metallic rigid PVC conduit accessories concealed on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxes concelled/surface in wall with suitable modular white cover plate with frame for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated FRLS copper conductor for continuous earth wire and connected to common earth dolly for the following :-
One light /fan point controlled by one 5/6 Amps switch.
One 3 pin 5/6 Amps socket outlet on same board
3 pin 5/6 Amps socket outlet on independent board
One call bell point controlled by one bell push
One 3 pin socket outlet 15/16 Amps independent with cable 2.5Sqmm size.
One 3 pin socket outlet 15/16 Amps independent with cable 4.0Sqmm size.
Material and Labour for Point wiring complete with 1.50sqmm single core PVC FRLS insulated sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including PVC casing & caping/PVC conduit on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of 1.6 mm thick MS pressed steel terminal boxes concealed in wall with 3 mm thick hylam sheet for housing switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated FRLS copper conductor for continious earth wire and connected to common earth dolly for the following :-
One light point/fan point controlled by one 5 Amps switch
One 3 pin 5 Amps socket outlet on same board
One 3 pin 5 Amps socket outlet on independent board
One 3 pin 5 Amps socket outlet independent but below the switch board of light points in the same vertical plane, with cables, 1.5 sqmm size.
One call bell point controlled by one bell push.
One 3 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size.
One 3 pin socket outlet 15 Amps independent with cable 4 Sq mm size.
Material & Labour for attending No supply /short circuit /checking of ups supply other electrical complaints and make serviceable complete all as specified and directed by Engineer-in-Charge. Note :- (i) complaint received from complaint cell (ii) required tools provided by contractor (iii) The rate quoted is deemed to included for insulation tape, wires /cable as specified and as directed. Note: Complaint not completed with 24 hrs Recovery made as per PS.
Taking down and Supply and fix the Modular switch 1 way 6A,1 module including disconecting, removing, and connecting into electric circuit complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for Modular switch 1 way 16A, 1 module complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for Modular socket 6A 3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for Modular socket 6A/16A 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for Modular Fan regulator 120 W 2 Module suitable for 1200mm/1400mm sweep fan complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for Switch piano flush type 5 Amps ,Single pole one way complete complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for Switch socket flush type 2 in 1, 3 pin 5 Amps 240 V complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for Switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for Fan regulator stepped type electronic flush/switch type, suitable for 1200mm /1400 mm sweep fan complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for PVC ceiling rose two to three terminal plate and jumbo type complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for Bell push Flush type 5 Amps complete all as specified and directed by Engineer-in-Charge.
All as per Item No.5 above but for Call bell 230 volts single pole A/C multi music fancy type ding dong bell complete all as specified and directed by Engineer-in-Charge.
Taking down and Supply and fix in replacement of laminated hyleum sheet 3 mm thick as per site required sie of 4''x4'' including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
Taking down and Supply and fix in replacement of laminated hyleum sheet 3 mm thick as per site required sie of 6''x8'' including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
Taking down and Supply and fix in replacement of laminated hyleum sheet 3 mm thick as per site required sie of 12"x8'' including cutting holes for fixing the switches /sockets etc and transfering all the switches/sockets including disconnecting and reconnecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge.
Taking down and Supply and fix, in replacement, of MCB DB SPN double door, IP-42,4 way 240 V neutral link, earth link complete all as specified and directed by Engineer-in-Charge.
Taking down and Supply and fix, in replacement of MCB DB SPN,IP-42 double door, 8 way 240 V with 200 A rated bus bar neutral link, earth link complete all as specified and directed by Engineer-in-Charge.
Taking down and Supply and fix in replacement for MCB DB TPN 4 way, IP-42 vertical type double door complete including 200A rated copper bus bar, and neutral and earth link suitable with MCB TPN as incomer complete all as specified and directed by Engineer-in-Charge.
Taking down and Supply and fix in replacement for MCB DB TPN 8 way, IP-42 vertical type double door complete including 200A rated copper bus bar, and neutral and earth link suitable with MCB TPN as incomer complete all as specified and directed by Engineer-in-Charge.
Taking down and Supply & fixing of Vertical type sheet metal enclosure MCB DB, IP-42 TPN 4 ways double door type including 125 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge.
Taking down and supply and fixing in replacement for MCB SP 06 to 32 Amps, 10KA 240 volts,50Hz complete all as specified and directed by Engineer-in-Charge.
Taking down and supply and fixing in replacement of MCB SPN 05 to 40 Amps 10KA 240 volts complete all as specified and directed by Engineer-in-Charge.
Taking down and supply and fixing in replacement of MCB TP 63 Amps 10KA 415 volts complete all as specified and directed by Engineer-in-Charge.
Taking down and supply and fix in replacement of MCB TPN 63 Amps 10KA 415 volts complete all as specified and directed by Engineer-in-Charge.
Taking down and supply and fix in replacement of MCB TP 100 Amps 10KA 415 volts complete all as specified and directed by Engineer-in-Charge.
Taking down and supply and fix in replacement of Single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20amps 240 Volts complete all as specified and directed by Engineer-in-Charge.
Taking down and supply and fix in replacement of MCCB 25 to 100amps 3/4 pole 16 KA breaking capacity 415 Volts complete all as specified and directed by Engineer-in-Charge.
Taking down existing sub main wiring any description along with PVC conduit/ casing capping and made good the disturbed surface complete all as specified and directed by Engineer-in-Charge.
M & L for circuit/sub main wiring complete with 2 X 2.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through existing surface/recessed steel/PVC conduit and accessories with 1 X 2.5 Sqmm of PVC FRLS copper cable for earth continuity all as specified, dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as directed by engineer- in- charge. Note : 2 runs of 2.5sqmm cable and 1 run of 2.5sqmm earth wire and one run of PVC conduit shall be considered as one unit run.
M & L for circuit/sub main wiring complete with 2 X 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 4 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as directed by Engineer- in- charge. Note : 2 runs of 4.0sqmm cable and 1 run of 4.0sqmm earth wire and one run of PVC conduit shall be considered as one unit run.
M & L for circuit/sub main wiring complete with 2 X 6 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through PVC conduit and accessories on surface of wall roofs etc with 1 X 6 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as directed by Engineer- in- charge. Note : 2 runs of 6sqmm cable and 1 run of 6sqmm earth wire and one run of PVC conduit shall be considered as one unit run.
M & L for circuit/sub main wiring complete with 4 X 4 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through suitable size PVC conduit and accessories on surface of wall roofs etc with 1 X 4 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as directed by Engineer- in- charge. Note : 4 runs of 4sqmm cable and 1 run of 4sqmm earth wire and one run of PVC conduit shall be considered as one unit run.
M & L for circuit/sub main wiring complete with 4 X 6 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through suitable size PVC conduit and accessories on surface of wall roofs etc with 1 X 6 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as directed by Engineer- in- charge. Note : 4 runs of 6sqmm cable and 1 run of 6sqmm earth wire and one run of PVC conduit shall be considered as one unit run.
All as per item No.38 here in before but for 4 x 10 Sqmm conductor with 1 x 10 Sqmm as earth continuity copper conductor complete all as specified and directed by Engineer-in-Charge. Note : 4runs of 10sqmm cable and 1 run of 10sqmm earth wire and one run of PVC conduit shall be considered as one unit run.
Taking down old light fitting & Supply and fix in replacement of LED 36 Watt fitting aesthetically Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling designed 2'x2' flat pannel suitable to false ceiling including provision of suitable flexiable PVC wire from ceiling rose to fittings complete all as specified and directed by Engineer-in-Charge. Make :- Havells or Equivalent.
Taking down old light fitting & Supply and fix energy saving & environmental friendly , long life, presure die - cast aluminium housing Flood light of 100 W with PC diffused lens enclosure over LED for glare light with resistance of IK07 with 10KV built in surge protection device complete all as specified and directed by Engineer-in-Charge. Make :- Havells or Equivalent.
Taking down old light fitting and S & F in replacement of Wall mounted light fitting LED batten, extruded heat sink provided for effcient heat dissipation & integrated electronic driver with 20 W LED 6500K (4 ft) lamp including disconecting, removing, and connecting into electric circuit and testing all as per directed by Engineer- in- charge. Make: Havells /Philips/Crompton
Taking down old light fitting and Supply and fix in replacement surface and wall mounted 10 Watt LED batten, provided for efficient heat dissipation with polycarbonate diffuser & intergrated electronic driver including LED lamp complete all as per directed by Engineer- in- charge. Make: Havells /Philips/Crompton .
Taking down old light fitting and S&F in replacement of security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with 35 W LED 5000K lamp including disconecting, removing, and connecting into electric circuit including testing all as directed by Engineer- in- charge. Make: Havells /Philips/Crompton .
M&L GI Bracket bend to shape, 40mm bore medium grade ISI marked and 1.50metre long with suitable MS clamps and nuts bolts etc, to fixing security light fittings to Bldgs complete after taking down the unsv GI bracket complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement RUGBY GENX 10 watt (Bulk head fitting) designed with beautiful asesthetics using new generation techonology in LED to enliven your outdoor and indoor area in perfect synchronization with functionality and aesthetics.family of bulked lights designed to completement the geometry of the area with modern design all as directed by Engineer- in- charge. Make: Havells /Philips/Crompton .
S&F Decorative LED wall light fitting stainless steel,rust free fixture with white glass diffuser including 15 W LED lamp complete all as specified and directed by Engineer-in-Charge. Make: Havells /Philips/Crompton
S&F LED Lamp 9W complete all as specified and directed by Engineer-in-Charge. Make: Havells /Philips/Crompton
S&F in replacement of Post top 25 Watt light fittings LED luminaire CORAL LED post top new generation IP 65 led post of family,energy saving, environmental friendly,long life aesthetically designed with symertical light distrubution,spun aluminium landscap luminaire with high power LEDs as light source.Opal cover offers soothing uniform illumination for different applications.all as directed by Engineer- in- charge. Make: Havells /Philips/Crompton
M&L for earthing complete with galvanized steel earth plate electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to GI earth lead wire 4.0mmdia by means of nuts, bolts, check nuts and washer of GI steel and connecting to testing point including provision of test point and all as shown in electrical plate No. 3 of SSR Pt I. The work shall inclusive of necessary earth work and PCC chamber 1:3:6 in type CI with 8mm CTD bar reinforcement both ways at 140 mm bents to centre including taking down old unserviceable earthing complete all as specified and directed by Engineer-in-Charge.
Supply and laying XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric cable(heavy duty) with aluminium conductor 1100 volts grade cross sectional area 2 core 6 sq mm in trenches/on truss/wall/floor through pipe with MS clamps complete all as specified and directed by Engineer-in-Charge.
Material and labour for Weather proof flat twin core cable of size 4 sqmm including suitable PVC Conduit complete all as specified and directed by Engineer-in-Charge.
Taking down carefully Existing ceiling fan/exhaust fan/wall Mounted fan/pedestal/Air circulator fan of any size/ Make after disconnecting the electrical connection etc complete all as specified and directed by Engineer-in-Charge.
Refixing/Instal only ceiling fan any size/make replacing the spares such as carter pin Unserviceable/Rusted nut bolts,split pin rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor, etc.And connecting up with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as specified and directed by Engineer-in-Charge. Note:- Rewinding,spare parts such as ball bearing, capacitor,bush etc required to make the ceiling fan serviceable shall be measured paid seperately under relevent items. .The Refixing fan shall be tested after fixing the blades.
Refixing /Install only Exhaust/Pedestal/Wall Mounted/aircirculator fans along with louvers any description any approval make, replacing the spares such as carter pin Unserviceable /Rusted nut bolts,split pin rubber wheel bearing washers,bush,PVC clamps for holdings of capacitor etc.And connecting up with PVC insulated cable size 1.5 Sqmm three core copper conductor round cable complete all as specified and directed by Engineer-in-Charge. Note:- Rewinding,spare parts such as ball bearing, capacitor,bush etc required to make the ceiling fan serviceable shall be measured paid seperately under relevent items..The Refixing fan shall be tested after fixing the blades.
Material and labour for rewinding of fan motor of exhaust fan 225 to 300 mm Sweep with super enameled copper winding wire of same gauge and weight as per OEM recommendation, after cutting and removing the existing burnt/heated up windings,including cleaning of rotor and varnishing,heating and providing fresh insulating Materials
All as per item No.56 above but of exhaust Fan 350 to 450mm Sweep
All as per item No.56 above but of Ceiling fan of any sweep
Taking down unserviceable ceiling fan and handing over to MES store for BER Process and Supply and fixing new 1200mm sweep BLDC ceiling fans complete with blades, down rod and accessories 230Volts,complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable exhaust fan and handing over to MES store for BER Process and Supply and fixing new 300mm sweep exhaust fan complete steel body, AC Single phase, 230volts with blades, louvers along with frame complete all as specified and directed by Engineer-in-Charge.
Taking down unserviceable exhaust fan and handing over to MES store for BER Process and Supply and fixing new 300mm sweep 1200rpm, copper winding exhaust fan complete steel body, AC Single phase, 230volts 50Hz with blades, louvers along with frame complete all as specified and directed by Engineer-in-Charge.
Supply only ball bearing size (6201/6202/6203) suitable for ceiling fans size 1200/1400 mm Sweep complete all as specified and directed by Engineer-in-Charge.
Supply only ball bearing Size (2001/2002/2003) suitable for exhaust/wall fan of any size and make complete all as specified and directed by Engineer-in-Charge.
Supply only capacitor of capacity 2.5 mfd for the fans in position as directed by Engineer -in-Charge.
Supply only capacitor of capacity 4 mfd for the fans in position as directed by Engineer -in-Charge.
Supply only GM bush suitable for ceiling fan of size 1200/1400 mm Sweep complete all as specified and directed by Engineer-in-Charge.
Supply only GM bush suitable for exhaust fans any make/size complete all as specified and directed by Engineer-in-Charge.
Supply only BLDC ceiling fan PCB board convertible 240 Volt AC to 12 Volt DC suitable for any type/model ceiling fan 1200 mm sweep 230 Volt 50 Hz complete all as specified and directed by Engineer-in-Charge.
Material & labour for Cleaning and preparing the surface of ceiling fan of any sweep, removing the grease,carbon dust over the fans,filling cavities with filler and applying one coat synthetic enamel paint painting of ceiling fan with down rod upto 2.00 mtr long with two coats of synthetic enamel white paint of approved colour by spraying including preparation of old painted surface & writing of MES No on the fan complete all as specified and directed by Engineer-in-Charge.
Material & labour for Cleaning and preparing the surface of exhaust /wall mounted /pedestal/Air circulated any sweep, removing the grease,carbon dust over the fans,filling cavities with filler and applying exisiting colour by synthetic enamel paint of approved colour by spraying including writing of MES No on the fan complete all as specified and directed by Engineer-in-Charge.
Taking down carefully storage type water heater (Geyser)of any type and make up to 25 /50 Ltrs capacity after disconnecting all Electrical connecting,descaling the inner container heating element base assembly etc by using diluted hydrochloric acid and cleanning thoroughly,filling the inner container with water and checking leakage if any reasembling the geyser after of leakage by bracing and electric and water supply lines,refixing and testing on completion complete all as specified and directed by Engineer-in-Charge. Note:-Spares shall be measured and paid saperately under relevent items of this Schedule.
supply only Heating Elements with rubber gasket thread/push type 230V,2.0/1.5 KW complete all as specified and directed by Engineer-in-Charge. Make:-Bajaj/Usha/Racold
Supply only Thermostart suitable for Geysers 25 to 50litre capasity,and temp range 30 to 80 degree centigrade and cut off at 70 degree centigrade complete all as specified and directed by Engineer-in-Charge.
Supply only 4 sqmm flexible industrial wire for water heater complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement 3 pin plug top 16 Amp complete all as specified and directed by Engineer-in-Charge.
Supply and fix PVC Connecting pipe 15 mm dia 450 mm long heavy duty suitable for hot/cold water with two brass union and washers complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5metre deep and not exceeding 1.5 mtr wide and getting out in hard/dense soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in soil including providing cable cushioning with riddled earth obtained from excavation, leveling watering and well ramming in layers not exceeding 25cm thick over the cushion layer complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as specified and directed by Engineer-in-Charge.
Relaying of old serviceable bricks of any size removed from old cable trenches laid across trenches for cable protection complete all as specified and directed by Engineer-in-Charge.
M&L for Plain Cement Concrete 1:4:8, type D-2, (using 40 mm graded stone aggregate) for foundation, filling and mass concrete including formwork complete all as specified and directed by Engineer-in-Charge.
M&L for Plain Cement Concrete 1:3:6, type C-1, using 20 mm graded stone aggregate as in foundation/ coping of poles including necessary form work and finishing the exposed concrete surfaces even and fair for Pole cooping with white wash complete all as specified and directed by Engineer-in-Charge.
Taking down old cable and S & F three core PVC insulated copper conductor 1.5 sqmm for making connection from light fitting complete all as specified and directed by Engineer-in-Charge.
Taking down old cable and S & F three core PVC insulated copper conductor 4 sqmm for making connection from light fitting complete all as specified and directed by Engineer-in-Charge.
S & F in repair PVC Conduit of 25mm dia including clamps, screws etc complete all as specified and directed by Engineer-in-Charge.
Taking down old Junction box and S&F PVC junction box out door type of size 280 mm x 170 mm x 130 mm with front openable hinged cover complete with two number aluminium bus bars and one MCB 6amps mounted on porcelain insulator including clamps of MS flat iron with bolts and nuts to fixed on pole and taking down of old unserviceable one complete all as specified and directed by Engineer-in-Charge.
Taking down any unserviceable light fitting including removing electric connection any height complete all as specified and directed by Engineer-in-Charge.
S&F bollard light fitting LED luminaires IP66 for diffused lighting with high power LED as light source with 8-10W LED lamp complete all as specified and directed by Engineer-in-Charge. Make:- Havells cat part No-BAMBOOBLS8WLED857PSYMTOPC (0.6 M) or equivalent
S&F Floodlight fitting LED luminaires IP66 high performance floodlight 100watts capacity including LED lamp complete all as specified and directed by Engineer-in-Charge.
S&F Floodlight fitting LED luminaires IP-66 New generation energy saving & environmental friendly long life high performance LED floodlight LF 19 with 150watt capacity LED lamp complete all as specified and directed by Engineer-in-Charge.
S&F Post-top light fitting LED luminaires IP 65 road way luminarie with high power LED with 40W LED 5000K lamp complete all as specified and directed by Engineer-in-Charge.
S&F LED Street light 70W fitting complete with IP 65 and Surge Protection device including fixing arrangements in height of not less than 7m complete all as specified and directed by Engineer-in-Charge.
S&F LED Street light 90W fitting complete with IP 65 and Surge Protection device including fixing arrangements in height of not less than 7m complete all as specified and directed by Engineer-in-Charge.
Taking out old Garden light pole & M&L Fancy type GI Pole 3metre height suitable post top lantern including Base plate, bolt , nut etc complete all as specified and directed by Engineer-in-Charge. Note:- Necessary earth work and PCC shall be measured and paid separately.
Taking out street light pole & M&L Street light Hexagonal/Octogonal GI Pole 7m height suitable bracket 1metre inluding Base plate, bolt , nut etc confirming relevant IS codal provision complete all as specified and directed by Engineer-in-Charge. Note:- Necessary Earth work and PCC shall be measured and paid separately.
Taking out the existing any description of LT UG cable of 10 sqmm to 25 sqmm 2/4 core and finding out the fault and re-laying of the same LT UG cable 1100 Volts grade PVC insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferrules connection, testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe, LT UG Cable Joints etc shall be measured separately under relevant items of this schedule . [ii] If old LT UG cable will found unserviceable, if required LT U/G cable shall be mesaured and paid as Supply and Laying of LT UG cable under relevant items of this schedule.
All as per item No.97 above but of 16 sqmm 4 core capacity complete all as specified and directed by Engineer-in-Charge.
All as per item No.97 above but of 25 sqmm 3.50 core complete all as specified and directed by Engineer-in-Charge.
Taking down old GI pipe and M&L GI tubing 'Light' grade of size 40 mm bore, ISI marked with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area complete all as specified and directed by Engineer-in-Charge.
Taking out old unserviceable UG cable & Supply and Laying LT UG cable of 10 sqmm 2 core, 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete all as specified and directed by Engineer-in-Charge. Note: [i] Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule .
All as per item No.101 above but 16 sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
All as per item No.101 above but 25 sqmm 3.50 core complete all as specified and directed by Engineer-in-Charge.
M&L for cable joint kit for 1.1 KV (earthed) grade cable for straight through heat shrinkable type complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor of size 10sqmm to 50sqmm
Vinayaga steel industries (BID ID -3382304)
rc enterprises (BID ID -3380523)
M/s Bakiyalakshmi Enterprises (BID ID -3383104)
Vishwa Enterprises (BID ID -3383175)
Global Safety Engineering and Management Solutions (BID ID -3384072)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .