Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹45.2 L
EMD Value
₹90,500
Closing Date
1 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE 861 EWS
GE 861 EWS
SPECIAL REPAIR OF DAMAGED LT UG CABLE FROM POWER HOUSE No 03 (ALONGWITH GD POST NO 14 TO GD POST NO 18) AT DEPOT AREA UNDER GE 861 EWS
2026_MES_784514_2
GE 861 EWS-38(T)/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 861 EWS
As per NIT
8 documents required · 8 mandatory
₹500
GE 861 EWS
₹90,500
GE 861 EWS
9 Nov 2026
9 Nov 2026
4 Dec 2026
9 Nov 2026
1 Dec 2026
24 Nov 2026
14 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old unserviceable service cable/underground (UG) cable of size 95 Sqmm x 3.50 Core, including removal of unserviceable bricks/PCC cable covers, with and including Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 500 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge.
Notes:
(a) Earth work such as excavation, returning filling and removal shall be measured and paid for separately under relevant items of Schedule 'A' BoQ..
(b) Where new/old cable is laid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible in this regard. | 255 | RM | - | - |
| 2 | Taking down old unserviceable service cable/underground (UG) cable of any size, including removal of unserviceable bricks/PCC cable covers, with and including Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 400 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge.
Notes:
(a) Earth work such as excavation, returning filling and removal shall be measured and paid for separately under relevant items of Schedule 'A' BoQ..
(b) Where new/old cable is laid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible in this regard. | 1,310 | RM | - | - |
| 3 | Supply , Fixing , Testing and commissioning out door type sub panel of size 1.0 Mtr x 0.9Mtr x 0.45Mtr with canopy at top , 3 phase 4 wire made out of 3.15mm thick CRCA sheet mounted on with and including PCC platform of PCC 1:2:4 Type-B 1 , using 20mm graded stone aggregates , with minimum 60cm ground clearance with and including aluminium bushbar of capacity 150 Amps comprising with following accessories including copper wiring of required size complete as per manufacturer's instructions :-
(a) MCCB 4 pole 415 volts 200 Amps 36kA - 01 No. (incoming)
(b) MCCB 4 pole 415 volts 200 Amps 36kA - 02 Nos. (01 No. x outgoing & 01 No. x spare)
(c) MCCB 160 Amps 4 pole 36kA - 01 No. (Outgoing)
(d) Voltmeter digital type - 01 No.
(e) Ammeter 0-100 Amp - 01 No.
(f) Indicator (RYB) - 01 set of three | 1 | Each | - | - |
| 4 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI strip 32mm x 6mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washersand including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI mediumt grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge.
Note:- (i) Earth continuity of GI strip 32mm x 6mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed.
(ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account.
(iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
(iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. | 2 | Each Set | - | - |
| 5 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, , cable , Pipes , etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in Hard /dense soil complete all as specified and as directed by Engineer-in- charge. | 530 | Cum | - | - |
| 6 | Returning filling , including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in any type of soil complete all as specified and as directed by Engineer-in- charge. | 338 | Cum | - | - |
| 7 | Removing excavated material of any type of soil not exceeding 50m and depositing where directedc at a level n exc 1.5 mtr above the starting point . complete all as specified and directed by Engr- in- charge. | 192 | Cum | - | - |
| 8 | Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed by Engr- in- charge.
(Note:- Punned thickness shall be considered for payment purpose) | 137 | Cum | - | - |
| 9 | Supplying and laying unreinforced precast concrete cable cover, class LV, type 2, flat size 300mm x 180mm x 40mm complete all as specified and directed by Engr- in- charge. | 8,450 | Each | - | - |
| 10 | Supply and Laying GI tubing 100mm bore Light grade with all fittings such as clamps laid in trenchs or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip complete all as specified and as directed by Engineer - in charge. | 36 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
Tender38T.pdf
Tender Documents • 1.07 MB
Credit38T.pdf
Additional Documents • 0.01 MB
BOQ_894134.xls
BOQ • 4.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .